IAIrene Avato

Irene Avato

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Irene Avato has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Genetics of Inner Ear Malformations: A Review

    by Davide Brotto, Flavia Sorrentino, Roberta Cenedese, Irene Avato, Roberto Bovo, Patrizia Trevisi, Renzo Manara

    Inner ear malformations are present in 20% of patients with sensorineural hearing loss. Although the first descriptions date to the 18th century, in recent years the knowledge about these conditions has experienced terrific improvement. Currently, most of these conditions have a rehabilitative option. Much less is known about the etiology of these anomalies. In particular, the evolution of genetics has provided new data about the possible relationship between inner ear malformations and genetic anomalies. In addition, in syndromic condition, the well-known presence of sensorineural hearing loss can now be attributed to the presence of an inner ear anomaly. In some cases, the presence of these abnormalities should be considered as a characteristic feature of the syndrome. The present paper aims to summarize the available knowledge about the possible relationships between inner ear malformations and genetic mutations.


  • Open Access

    The role of cochlear implant positioning on MR imaging quality: a preclinical in vivo study with a novel implant magnet system

    by Pietro Canzi, Marianna Magnetto, Anna Simoncelli, Marco Manfrin, Federico Aprile, Elvis Lafe, Elena Carlotto, Irene Avato, Andrea Scribante, Lorenzo Preda, et al.

    Purposes: To investigate the effects for Ultra 3D cochlear implant (CI) positioning on MR imaging quality, looking at a comprehensive description of intracranial structures in cases of unilateral and bilateral CI placement. Methods: Four CI angular positions (90°, 120°, 135° and 160°) at 9 cm distance from the outer-ear canal were explored. The 1.5 T MRI assessment included our institutional protocol for the investigation of brain pathologies without gadolinium application. Three investigators (two experienced neuroradiologists and one experienced otoneurosurgeon) independently evaluated the MR findings. A 4-point scale was adopted to describe 14 intracranial structures and to determine which CI positioning allowed the best image quality score and how bilateral CI placement modified MRI scan visibility. Results: A high positive correlation was found between the three blinded observers. Structures situated contralateral from the CI showed high-quality values in all four placements. Structures situated ipsilaterally provided results suitable for diagnostic purposes for at least one position. At 90°, artifacts mainly involved brain structures located cranially and anteriorly (e.g., temporal lobe); on the contrary, at 160°, artifacts mostly influenced the posterior fossa structures (e.g., occipital lobe). For the bilateral CI condition, MR imaging examination revealed additional artifacts involving all structures located close to either CI, where there was a signal void/distortion area. Conclusions: Suitable unilateral CI positioning can allow the visualization of intracranial structures with sufficient visibility for diagnostic purposes. Bilateral CI positioning significantly deteriorates the anatomical visibility. CI positioning might play a crucial role for patients who need post-operative MRI surveillance.


  • Open Access

    MRI-induced artifact by a cochlear implant with a novel magnet system: an experimental cadaver study

    by Pietro Canzi, Federico Aprile, Anna Simoncelli, Marco Manfrin, Marianna Magnetto, Elvis Lafe, Domenico Minervini, Irene Avato, Simone Terrani, Andrea Scribante, et al.

    Purposes: To primarily evaluate MRI-induced effects for Ultra 3D cochlear implantation in human cadavers in terms of artifact generation and MR image quality. Methods: Three human cadaveric heads were submitted to imaging after unilateral and bilateral cochlear implantation. The 1.5 T MR examination protocol was chosen in accordance with our institutional protocol for the assessment of brain pathology. The maximal signal void size was measured according to each sequence and plane. Two experienced neuro-radiologists and one experienced otoneurosurgeon independently evaluated the MR image quality findings. A 4-point scale was used to describe the diagnostic usefulness of 14 brain structures. Results: Shape and size of the artifacts were found to be highly related to MRI sequences and acquisition planes. MRI sequences and processing algorithms affected the ability to assess anatomical visibility. Image quality appeared either high or assessable for diagnostic purposes in 9 out of 14 of the ipsilateral structures, in at least one plane. Anatomical structures contralateral to the cochlear implant were highly visible in all conditions. Artifact intrusion clearly improved after application of metal artifact-reduction techniques. In the case of bilateral cochlear implant, a mutual interaction between the two implant magnets produced an additional artifact. Conclusions: We performed the first cadaver study aimed at systematically evaluating the MRI-induced artifacts produced by a cochlear implant with a novel four bar magnet system. Specific brain structures can be assessable for diagnostic purposes under 1.5 T MRI, with the cochlear implant magnet in place.


  • Open Access

    Isolated Eustachian Tube Osteoma: Common Lesion in Uncommon Site

    by Pietro Canzi, Elena Carlotto, Marco Manfrin, Irene Avato, Matteo Nardo, Anna Maria Simoncelli, Fabio Pagella, Marco Benazzo

    Isolated Eustachian tube osteomata are a very rare entity indeed, with the last case being reported in 1979. We describe a case of the otoscopic finding of a blue-yellowish eardrum and successive identification by computed tomography scan of an osteoma localized in the Eustachian tube. Clinical presentation and diagnostic and therapeutic phases in comparison with the literature will be discussed. Cite this article as: Canzi P, Carlotto E, Manfrin M, Avato I, Nardo M, Simoncelli AM, et al. Isolated Eustachian Tube Osteoma: Common Lesion in Uncommon Site. J Int Adv Otol 2020; 16(3): 481-3.


  • Open Access

    “Emergency” Cochlear Implantation in Labyrinthitis Ossificans Secondary to Polyarteritis Nodosa: How to Face a Rare Entity

    by Lorenzo Cavagna, Marco Benazzo, Pietro Canzi, Federico Aprile, Marco Manfrin, Irene Avato, Marianna Magnetto, Domenico Minervini

    Polyarteritis nodosa (PAN) is a systemic vasculitis affecting the small- and medium-sized arteries that may present with hearing impairment. In rare cases, PAN may be associated with progressive labyrinthitis ossificans (LO), an otologic emergency requiring early cochlear implantation (CI) to restore hearing before the complete, irreversible cochlear ossification. We report the first case in the literature of a patient affected by PAN with bilateral sudden sensorineural hearing loss and rapid LO who underwent “emergency” bilateral simultaneous CI. This case report emphasizes the importance of an early audiological evaluation in patients with PAN when LO is suspected. Multidisciplinary approach is mandatory when facing organ-specific manifestations in patients with PAN. Detailed discussion is provided with particular regard to clinical and radiological presentation as well as CI outcomes in such a rare and challenging case. Cite this article as: Canzi P, Aprile F, Manfrin M, Avato I, Magnetto M, Minervini D, et al. “Emergency” Cochlear Implantation in Labyrinthitis Ossificans Secondary to Polyarteritis Nodosa: How to Face a Rare Entity. J Int Adv Otol 2019; 15(1): 156-9.


  • Epidemiologic, Imaging, Audiologic, Clinical, Surgical, and Prognostic Issues in Common Cavity Deformity

    by Davide Brotto, Irene Avato, Elisa Lovo, Eva Muraro, Roberto Bovo, Patrizia Trevisi, Alessandro Martini, Renzo Manara

    Importance Common cavity deformity is a rare congenital inner ear malformation associated with profound hearing loss and attributed to an early developmental arrest of the cochlear-vestibular structures. This narrative review highlights the need to identify reliable indicators of hearing rehabilitation outcome. Observations Despite its relatively simple definition, common cavity deformity varies widely in morphologic features, presence of cochlear nerve fibers and remnants of Corti organ, and outcome after cochlear or brainstem implant. Conclusions and Relevance Cochlear implant has been shown to be a valid option for common cavity deformity, but its outcome remains variable and poor. Identification of specific neuroradiologic, audiologic, and neurophysiologic prognostic features; tailoring of the surgical approach; and standardization of outcome measures are needed to optimize the management of common cavity deformity and hearing rehabilitation after implant.