Marianna Magnetto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marianna Magnetto has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Federico Aprile
Department of Otorhinolaryngology, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Pavia, Italy
3 shared publications - Irene Avato
Department of Experimental Medicine, University of Pavia, IRCCS Policlinico "S. Matteo" Foundation, Pavia, Italy
3 shared publications - Marco Manfrin
Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, Pavia, Italy
3 shared publications - Pietro Canzi
Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy
3 shared publications - Andrea Scribante
Unit of Orthodontics and Pediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy
2 shared publications - Anna Simoncelli
Department of Diagnostic Radiology and Interventional Radiology and Neuroradiology, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Pavia, Italy
2 shared publications
Latest Publications
- Open Access
- 9 August 2021
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 279 (6) , 2889-2898
The role of cochlear implant positioning on MR imaging quality: a preclinical in vivo study with a novel implant magnet system
Purposes: To investigate the effects for Ultra 3D cochlear implant (CI) positioning on MR imaging quality, looking at a comprehensive description of intracranial structures in cases of unilateral and bilateral CI placement. Methods: Four CI angular positions (90°, 120°, 135° and 160°) at 9 cm distance from the outer-ear canal were explored. The 1.5 T MRI assessment included our institutional protocol for the investigation of brain pathologies without gadolinium application. Three investigators (two experienced neuroradiologists and one experienced otoneurosurgeon) independently evaluated the MR findings. A 4-point scale was adopted to describe 14 intracranial structures and to determine which CI positioning allowed the best image quality score and how bilateral CI placement modified MRI scan visibility. Results: A high positive correlation was found between the three blinded observers. Structures situated contralateral from the CI showed high-quality values in all four placements. Structures situated ipsilaterally provided results suitable for diagnostic purposes for at least one position. At 90°, artifacts mainly involved brain structures located cranially and anteriorly (e.g., temporal lobe); on the contrary, at 160°, artifacts mostly influenced the posterior fossa structures (e.g., occipital lobe). For the bilateral CI condition, MR imaging examination revealed additional artifacts involving all structures located close to either CI, where there was a signal void/distortion area. Conclusions: Suitable unilateral CI positioning can allow the visualization of intracranial structures with sufficient visibility for diagnostic purposes. Bilateral CI positioning significantly deteriorates the anatomical visibility. CI positioning might play a crucial role for patients who need post-operative MRI surveillance.
- 9 August 2021
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 279 (6) , 2889-2898
Open AccessThe role of cochlear implant positioning on MR imaging quality: a preclinical in vivo study with a novel implant magnet system
Purposes: To investigate the effects for Ultra 3D cochlear implant (CI) positioning on MR imaging quality, looking at a comprehensive description of intracranial structures in cases of unilateral and bilateral CI placement. Methods: Four CI angular positions (90°, 120°, 135° and 160°) at 9 cm distance from the outer-ear canal were explored. The 1.5 T MRI assessment included our institutional protocol for the investigation of brain pathologies without gadolinium application. Three investigators (two experienced neuroradiologists and one experienced otoneurosurgeon) independently evaluated the MR findings. A 4-point scale was adopted to describe 14 intracranial structures and to determine which CI positioning allowed the best image quality score and how bilateral CI placement modified MRI scan visibility. Results: A high positive correlation was found between the three blinded observers. Structures situated contralateral from the CI showed high-quality values in all four placements. Structures situated ipsilaterally provided results suitable for diagnostic purposes for at least one position. At 90°, artifacts mainly involved brain structures located cranially and anteriorly (e.g., temporal lobe); on the contrary, at 160°, artifacts mostly influenced the posterior fossa structures (e.g., occipital lobe). For the bilateral CI condition, MR imaging examination revealed additional artifacts involving all structures located close to either CI, where there was a signal void/distortion area. Conclusions: Suitable unilateral CI positioning can allow the visualization of intracranial structures with sufficient visibility for diagnostic purposes. Bilateral CI positioning significantly deteriorates the anatomical visibility. CI positioning might play a crucial role for patients who need post-operative MRI surveillance.
- Open Access
- 18 November 2020
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 278 (10) , 3753-3762
MRI-induced artifact by a cochlear implant with a novel magnet system: an experimental cadaver study
Purposes: To primarily evaluate MRI-induced effects for Ultra 3D cochlear implantation in human cadavers in terms of artifact generation and MR image quality. Methods: Three human cadaveric heads were submitted to imaging after unilateral and bilateral cochlear implantation. The 1.5 T MR examination protocol was chosen in accordance with our institutional protocol for the assessment of brain pathology. The maximal signal void size was measured according to each sequence and plane. Two experienced neuro-radiologists and one experienced otoneurosurgeon independently evaluated the MR image quality findings. A 4-point scale was used to describe the diagnostic usefulness of 14 brain structures. Results: Shape and size of the artifacts were found to be highly related to MRI sequences and acquisition planes. MRI sequences and processing algorithms affected the ability to assess anatomical visibility. Image quality appeared either high or assessable for diagnostic purposes in 9 out of 14 of the ipsilateral structures, in at least one plane. Anatomical structures contralateral to the cochlear implant were highly visible in all conditions. Artifact intrusion clearly improved after application of metal artifact-reduction techniques. In the case of bilateral cochlear implant, a mutual interaction between the two implant magnets produced an additional artifact. Conclusions: We performed the first cadaver study aimed at systematically evaluating the MRI-induced artifacts produced by a cochlear implant with a novel four bar magnet system. Specific brain structures can be assessable for diagnostic purposes under 1.5 T MRI, with the cochlear implant magnet in place.
- 18 November 2020
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 278 (10) , 3753-3762
Open AccessMRI-induced artifact by a cochlear implant with a novel magnet system: an experimental cadaver study
Purposes: To primarily evaluate MRI-induced effects for Ultra 3D cochlear implantation in human cadavers in terms of artifact generation and MR image quality. Methods: Three human cadaveric heads were submitted to imaging after unilateral and bilateral cochlear implantation. The 1.5 T MR examination protocol was chosen in accordance with our institutional protocol for the assessment of brain pathology. The maximal signal void size was measured according to each sequence and plane. Two experienced neuro-radiologists and one experienced otoneurosurgeon independently evaluated the MR image quality findings. A 4-point scale was used to describe the diagnostic usefulness of 14 brain structures. Results: Shape and size of the artifacts were found to be highly related to MRI sequences and acquisition planes. MRI sequences and processing algorithms affected the ability to assess anatomical visibility. Image quality appeared either high or assessable for diagnostic purposes in 9 out of 14 of the ipsilateral structures, in at least one plane. Anatomical structures contralateral to the cochlear implant were highly visible in all conditions. Artifact intrusion clearly improved after application of metal artifact-reduction techniques. In the case of bilateral cochlear implant, a mutual interaction between the two implant magnets produced an additional artifact. Conclusions: We performed the first cadaver study aimed at systematically evaluating the MRI-induced artifacts produced by a cochlear implant with a novel four bar magnet system. Specific brain structures can be assessable for diagnostic purposes under 1.5 T MRI, with the cochlear implant magnet in place.
- Open Access
- 3 September 2019
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 15 (1) , 156-159
“Emergency” Cochlear Implantation in Labyrinthitis Ossificans Secondary to Polyarteritis Nodosa: How to Face a Rare Entity
Polyarteritis nodosa (PAN) is a systemic vasculitis affecting the small- and medium-sized arteries that may present with hearing impairment. In rare cases, PAN may be associated with progressive labyrinthitis ossificans (LO), an otologic emergency requiring early cochlear implantation (CI) to restore hearing before the complete, irreversible cochlear ossification. We report the first case in the literature of a patient affected by PAN with bilateral sudden sensorineural hearing loss and rapid LO who underwent “emergency” bilateral simultaneous CI. This case report emphasizes the importance of an early audiological evaluation in patients with PAN when LO is suspected. Multidisciplinary approach is mandatory when facing organ-specific manifestations in patients with PAN. Detailed discussion is provided with particular regard to clinical and radiological presentation as well as CI outcomes in such a rare and challenging case. Cite this article as: Canzi P, Aprile F, Manfrin M, Avato I, Magnetto M, Minervini D, et al. “Emergency” Cochlear Implantation in Labyrinthitis Ossificans Secondary to Polyarteritis Nodosa: How to Face a Rare Entity. J Int Adv Otol 2019; 15(1): 156-9.
- 3 September 2019
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 15 (1) , 156-159
Open Access“Emergency” Cochlear Implantation in Labyrinthitis Ossificans Secondary to Polyarteritis Nodosa: How to Face a Rare Entity
Polyarteritis nodosa (PAN) is a systemic vasculitis affecting the small- and medium-sized arteries that may present with hearing impairment. In rare cases, PAN may be associated with progressive labyrinthitis ossificans (LO), an otologic emergency requiring early cochlear implantation (CI) to restore hearing before the complete, irreversible cochlear ossification. We report the first case in the literature of a patient affected by PAN with bilateral sudden sensorineural hearing loss and rapid LO who underwent “emergency” bilateral simultaneous CI. This case report emphasizes the importance of an early audiological evaluation in patients with PAN when LO is suspected. Multidisciplinary approach is mandatory when facing organ-specific manifestations in patients with PAN. Detailed discussion is provided with particular regard to clinical and radiological presentation as well as CI outcomes in such a rare and challenging case. Cite this article as: Canzi P, Aprile F, Manfrin M, Avato I, Magnetto M, Minervini D, et al. “Emergency” Cochlear Implantation in Labyrinthitis Ossificans Secondary to Polyarteritis Nodosa: How to Face a Rare Entity. J Int Adv Otol 2019; 15(1): 156-9.