BLBenoit Lacroix

Benoit Lacroix

*This is an algorithmically generated author record based on publicly available information.

Benoit Lacroix has a total of 95 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Magnet Design Activities at CEA for EU-DEMO LAR Baseline 2024

    by M. F. Sutcliffe, A. Torre, B. Boudes, B. Lacroix, Q. Le Coz, C. Nguyen Thanh Dao, S. Nicollet, V. Corato

    In 2024, a new EU-DEMO baseline (called LAR for Low Aspect Ratio) was released which substantially changed the constraints on the magnets systems, with a key driver for changes the magnet systems being mechanical considerations. This paper will briefly list changes in the new baseline, and give an overview of updates to the CEA design toolbox MADMACS, particularly the implementation of fatigue analysis for the pulsed central solenoid (CS), and consideration of hybrid low/high-temperature superconducting CS coils. The new fatigue tool is later used to perform sensitivity analysis on the assumed parameters for Walker exponent and residual stress, with results showing that further study of these parameters should be of high priority. Summaries of new preliminary toroidal field (TF) coil and CS designs, based on ITER-like approaches, are also given. The final TF design required modifications to the winding pack dimensions, and the CS could only meet all the requirements using HTS inner turns, new jacket materials, and relaxations in fatigue assumptions. Therefore, it is clear that the LAR baseline has not yet resolved the static and fatigue concerns for the magnet systems, when considering ITER-like TF and CS solutions, but that this may be possible with further development.


  • JT-60SA Central Solenoid Conductor Hotspot Risk Analysis for High Voltage Protection

    by L. Zani, T. Françonnet, B. Lacroix, Q. Le Coz, S. Sonoda, H. Murakami, L. Novello, M. Parody-Guzman, K. Hamada

    The upgrade to JT-60SA tokamak was conducted within a Europe-Japan collaboration agreement including superconducting magnets implementation. In 2021, an arcing issue on a coil led to an overall magnet insulation reinforcement against high voltage. The Central Solenoid (CS), less accessible for repair, deserving specific attention versus voltage exposure, a risk mitigation was considered to address fast discharge event, which results in the highest voltage application. Maximum voltage during discharge being proportional to the external dump resistance (RDUMP), it is aimed at decreasing this resistance by 30%, inducing a slower current decrease after a quench, therefore a higher Joule energy absorbed by conductor. This induces a higher temperature rise in the conductor, increasing the risk of thermo-mechanical degradation due to hotspot occurrence. A risk analysis is performed to better understand the impact on the conductor. A methodology is followed to define streamlined hotspot risk criteria, backed by rationale and references to support the establishment of those methodological elements. Thermo-hydraulic simulations on the CS magnet, that were extensively produced, are analyzed to ensure that even after dump resistance modification, the hotspot safety limits are still respected. For this, a reference case and associated parametric studies were explored using THEA code. Finally, a positive recommendation is issued to validate and implement the JT-60SA project team decision to decrease the CS magnet RDUMP. Further perspectives are also evaluated.

  • Optimizing Cooling Strategies for CORC Conductors in High-Field Fusion Applications

    by Jonathan Pavan, B. Lacroix, A. Torre, F. Topin, A. Badel, Q. Le Coz, S. Nicollet, G. Jiolat

    This work presents a comparative thermal–hydraulic analysis of a CORC (Conductor On Round Core) cable under two classes of external perturbation, fast (20 ms) and slow (1 s), with the goal of evaluating its stability against quench. Four configurations are modeled, each differing in helium flow topology: adiabatic, 1-channel, 2-channel, and 3-channel. The simulations include the effect of thermal contact resistance and friction factor uncertainty in the tape bundle. Results show that under fast perturbations, helium's contribution to stability is limited unless it is in direct contact with the superconducting tapes, while for slow perturbations, helium cooling plays a dominant stabilizing role. Since stability must be achieved across the temperature range from ∼ 4.5 K to 20 K, helium emerges as a key actor in any cooling strategy designed for these conditions. The addition of a relief channel in the 3-channel configuration effectively reduces pressure buildup during fast transients with minimal stability penalty and further enhances performance under slow perturbations.


  • Study of CORC Conductors With Respect to Individual Tape Properties

    by A. Torre, J. Pavan, B. Lacroix, C. Nguyen Thanh Dao, V. Corato, D.C. van der Laan

    CEA has been studying the advantages of a conductor based on an assembly of CORC cables in the high field zone of a hybrid Central Solenoid (CS) magnet for EU-DEMO. To this end, the detailed study of geometrical and electrical parameters of a CORC structure are studied in order to evaluate the cable’s electrical performance as well as to determine a number of important parameters (crossing points, contact surface etc…) as function of the cable structure. The paper first presents these geometrical and performance analyses. It will then try to introduce smeared models in order to reduce the cable’s performance to 1D tape scaling law using effective parameters. That reduction is of importance for use in thermohydraulic models. Finally, the paper will present the case study of a particular CORC conductor that is being procured and is foreseen to be tested in SULTAN in 2025. The paper will try to give some predictive estimate of the cable performance and identify some of the unknowns related to current redistribution and joint resistance.


  • Effective thermal conductivity numerical estimations of CICC porous media using X-ray tomography images

    by Q. Gorit, R. Babouche, D. Dumitru, B. Lacroix, A. Louzguiti, M. Lungu, S. Nicollet, I. Tiseanu, A. Torre, F. Topin, et al.


  • Exploring Operation Limits of JT-60SA Cryomagnet Operation: Integrated Commissioning Database Use for Modeling Analysis

    by L. Zani, Q. Le Coz, K. Hamada, M. Parody-Guzman, B. Lacroix, L. Novello

    In the framework of international development on fusion devices, the tokamak JT-60SA was equipped with superconducting magnets within a Europe-Japan collaboration. After a first integrated commissioning (IC) in 2021, another IC was conducted in 2023 reaching magnet energization levels compliant with 1 MA-class plasmas. The Toroidal Field (TF) coil system was loaded at nominal current and the Poloidal Field (PF) at 50% of nominal current. In the 2023 IC various energization pulse patterns were applied on PF coils to gain experience on the magnets control and protection system in operation conditions. Some tailored current pulses were applied to learn about PF coils coupling parameters and protection system, which sensitivity was found to be improved. In this environment, we developed tools and methods to model and predict the magnets behaviour to possibly identify coils limits in operation conditions. First step is with thermo-hydraulic evaluation of PF coil temperature safety margin evaluation along their pulsed current patterns. Second step is a first order analysis of the TF quench detection system sensitivity, found higher than expected to PF transients, and the contribution to possible mitigation measures to avoid spurious false positive detections. Both steps were benchmarked against experimental data collected during 2023 IC to consolidate models prediction capacities. Foreseen applications aim at checking plasma scenarios repetability rate or avoiding pulsed coil current to generate apparent fault signal in absence of real risk (mostly quench). The tools and methods are described and their rationales explained, together with their intrinsic limits and room for improvement.


  • Thermohydraulical Analysis and Fast Assessment of Operating Windows for JT-60SA TFC Commissioning

    by S. Nicollet, F. Bonne, Q. Gorit, B. Lacroix, Q. Le Coz, F. Michel, A. Torre, L. Zani

    JT-60SA Toroidal Field Coils (TFC) comprise each a Winding Pack (WP), with 6 Cable-In-Conduit Conductor (CICC) lengths wound in 6 double-pancakes operating at 25.7 kA nominal current and 4.7 K temperature as well as stainless steel casing cooled by forced flow channels. Second phase of Integrated Commissioning (IC) have been performed during 2023 with current discharge and induced AC losses in the CICC and eddy currents in the structures. A Fast Assessment of Operating Window (FAOW) model was developed for this purpose and permits to assess heat loads inputs, the heat transfer from casing to WP with inertia effect and time delay, and the cooling capacities (through heat exchanger). This FAOW model is coupled to Superconductors Thermohydraulical and Resistive Electrical Analytical Model (STREAM) and permits to evaluate helium pressure and temperature increase in cooling loop. The IC 18 kA current discharge measurements are compared to calculated results thus validating models and analyses. Predictive calculated results for other current discharge values (15, 18, 20, 23.7 and 25.7 kA) are presented and discussed with the maximal helium pressure limits, and safety aspects (induced relief valves opening or not). These analyses of current values operating windows have been confirmed by further plasma operation at 23.7 kA. Even if the limits of the model are discussed, the main interest consists of rapid execution time duration (only few minutes) compared to numerical codes (several hours). This work and fast analysis tool and model (FAOW-STREAM) can be also useful for further performances analyses in view to recommend their use in similar ITER or EU-DEMO magnets, with possibility of real-time feed-forward calculations/control.


  • 35 Years of TF Magnet System Operation in Tore Supra-WEST: Status and Lessons Learnt

    by S. Girard, A. Torre, J.-L. Duchateau, P. Martino, Y. Moudden, N. Dumas, P. Coquillat, F. Deguara, S. Nicollet, B. Lacroix, et al.

    The 500 MJ superconducting toroidal field magnet of TORE SUPRA - WEST has been providing a 4 T magnetic field on the tokamak plasma axis since 1988. The magnet is bath-cooled with superfluid helium at 1.8 K, and operates in steady state each experimental day. During those years, the magnet internal structure has not been modified, but several interfaces and auxiliary systems required for its operation have been upgraded. This paper aims at giving an overview of the Tore Supra-WEST toroidal field magnet system. Main issues and upgrades are described while providing the community a valuable long-life operation feedback and return on experience. We will go through the normal operation sequences and the incidental events, trying to point out key components failures and recovery actions undertaken. We will also develop the main subsystems evolutions such as the quench protection system, the data acquisition and the control systems. We will outline the major risks and mitigation schemes followed as well as the strategies adopted to ensure adequate maintenance, to preserve skills and knowledge continuity over such a long and eventful operating time-frame.


  • Dynamic Optimization of the Thermal Hydraulic Parameters for the DEMO's CS Magnet

    by N. Richermoz, F. Bonne, B. Lacroix, Q. Le Coz, F. Michel, F. Millet, S. Nicollet, A. Torre

    The DEMO project is a magnetic-confinement fusion reactor conceived as a technology demonstrator for a fusion power plant. In order to search for a cryogenic and magnetic optimal design such a large and complex project requires dynamic mutli-parameters studies. Thus, regarding a magnet design [1], using Simcryogenics, 0D cryogenic components in the forced-flow cooling loop and 1D Cable-In-Conduct-Conductors (CICC) and pipes are modeled. This code is particularly efficient in performing thermal-hydraulic parametric calculations with pulsed heat loads. This paper presents the exploration study of the Central Solenoid (CS), using the CEA 2022 magnet design [1]. Thermal-hydraulic calculations are performed under pulsed magnetic field operation and variable cryogenic operating conditions keeping constant temperature margin. The 1.5 K temperature margin requirement is obtained by adjusting the inlet temperature for a given pressure head at constant inlet pressure. The resulting data are analyzed through the lens of the global cryogenic cost, considering the expected operating cost of exergy at 4.5 K and the expected cryogenic capital cost. It then allows to estimate the optimal region in term of cryogenic operating parameters.

  • Latest Developments of OLYMPE Platform for Optimizing Design of Fusion Cryomagnetic Systems

    by B. Lacroix, Q. Le Coz, A. Louzguiti, S. Nicollet, A. Torre, L. Zani, P. Barjhoux, F. Bonne, F. Nunio

    In the framework of design studies for large fusion magnets, the development of the OLYMPE multi-physic platform is ongoing at CEA. This platform gathers different solvers and codes for addressing the interdependent analyses required for tokamak superconducting magnet design. The present article focuses on the coupling between conductor design, thermohydraulics, and electromagnetism. The corresponding OLYMPE module aims at producing factors of merit such as the amount of superconducting material, together with major parameters impacting the cryogenic system (operating conditions, thermal loads on the magnet). The Thermo-Hydraulic Design (THD) loop was first developed for TF magnet, considering the most critical conductor and a single burn cycle. The loop is improved by extending the model to coil scale, thus including the whole winding pack, and by considering four burn-dwell cycles so as to reach a periodic behaviour. The case of an EU-DEMO TF magnet design is applied, and the comparison of results before and after THD loop upgrade confirms the validity of first loop version for exploratory studies. The second part of the study focuses on the development of CS magnet design module. The dimensioning process specific to CS results in significant differences with the TF design loop. In particular, the CS design loop requires updating the magnetic field distribution at each design iteration, while the assessment of AC losses thermal load requires defining a scenario for the current in each CS module. Consequently, the CS design process merges electromagnetic and thermohydraulic loops. The workflow is applied to an EU-DEMO CS magnet design.