Thermohydraulical Analysis and Fast Assessment of Operating Windows for JT-60SA TFC Commissioning
- 30 April 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-6
Abstract
JT-60SA Toroidal Field Coils (TFC) comprise each a Winding Pack (WP), with 6 Cable-In-Conduit Conductor (CICC) lengths wound in 6 double-pancakes operating at 25.7 kA nominal current and 4.7 K temperature as well as stainless steel casing cooled by forced flow channels. Second phase of Integrated Commissioning (IC) have been performed during 2023 with current discharge and induced AC losses in the CICC and eddy currents in the structures. A Fast Assessment of Operating Window (FAOW) model was developed for this purpose and permits to assess heat loads inputs, the heat transfer from casing to WP with inertia effect and time delay, and the cooling capacities (through heat exchanger). This FAOW model is coupled to Superconductors Thermohydraulical and Resistive Electrical Analytical Model (STREAM) and permits to evaluate helium pressure and temperature increase in cooling loop. The IC 18 kA current discharge measurements are compared to calculated results thus validating models and analyses. Predictive calculated results for other current discharge values (15, 18, 20, 23.7 and 25.7 kA) are presented and discussed with the maximal helium pressure limits, and safety aspects (induced relief valves opening or not). These analyses of current values operating windows have been confirmed by further plasma operation at 23.7 kA. Even if the limits of the model are discussed, the main interest consists of rapid execution time duration (only few minutes) compared to numerical codes (several hours). This work and fast analysis tool and model (FAOW-STREAM) can be also useful for further performances analyses in view to recommend their use in similar ITER or EU-DEMO magnets, with possibility of real-time feed-forward calculations/control.Keywords
Funding Information
- European Commission (101052200)
This publication has 9 references indexed in Scilit:
- Superconductor thermohydraulical and resistive electrical analytical model (STREAM) applied to WEST TF coil quench analysisCryogenics, 2022
- AC Losses in JT-60SA TF Magnet During Commissioning: Experimental Analysis and ModelingIEEE Transactions on Applied Superconductivity, 2022
- Completion of JT-60SA construction and contribution to ITERNuclear Fusion, 2022
- JT-60SA TF coils procured by ENEA: An intermediate assessmentFusion Engineering and Design, 2017
- Results of the first JT-60 SA toroidal field coils tests in the cold test facilityFusion Engineering and Design, 2017
- Manufacturing and acceptance by CEA of the first JT-60SA TF coilsFusion Engineering and Design, 2017
- Recent progress of the JT-60SA projectNuclear Fusion, 2017
- Flower, a model for the analysis of hydraulic networks and processesCryogenics, 2003
- A general model for thermal, hydraulic and electric analysis of superconducting cablesCryogenics, 2000