Gemma Taverni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gemma Taverni has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Anh Tuan Do
Institute of Microelectronics, Agency for Science, Technology and Research, Singapore, Singapore, Singapore
1 shared publication Annarita Cutrone
Biorobotics Institute, Scuola Superiore Sant'Anna, 56025 Pontedera, Italy, and also with SMANIA S.r.l., 56124 Pisa, Italy
1 shared publication- Astrid Rusly
Department of Electrical and Computer Engineering, National University of Singapore, Singapore 117583, Singapore
1 shared publication - Bin Zhao
Department of IC Design, Institute of Microelectronics, A\ast STAR, Singapore 138643
1 shared publication - Celso Cavaco
IMEC, Leuven, Belgium
1 shared publication - Chao Yuan
Synaptics, TianFu Software Park, Chengdu 610041, China
1 shared publication
Latest Publications
- 7 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 54 (8) , 2266-2280
A Wireless Multi-Channel Peripheral Nerve Signal Acquisition System-on-Chip
The adoption of chronic implantable peripheral nerve-based prosthetic devices is currently hampered by the lack of a highly integrated neural signal acquisition system-on-chip (SoC). We report a ten-channel peripheral nervous system (PNS) electroneurogram (ENG) signal acquisition SoC within an implantable package. Requiring only four off-chip capacitors, this SoC can be co-encapsulated with flexible nerve electrodes and a resonant coil antenna to form a 3.4 cm³ and 3.9 g implantable device for chronic ENG acquisition. This SoC is inductively powered and controlled through a resonant coil at 22 MHz and transmits the digitized neural signal through a near-infrared LED (NIR-LED). Fabricated in 0.18-μm CMOS, each amplifier channel exhibits an input referred noise of 1.9 μVrms and a noise efficiency factor (NEF) of 4.0 within the signal bandwidth of 5.5 kHz. Each amplifier channel within the SoC is digitized with 10-bit resolution at 17.5 ksps, and the total power consumption (SoC and NIR-LED) is 4.4 mW when the NIR-LED is driven at 3 Mb/s. An electrode impedance measurement circuit with <10% magnitude and <8° angle error for measuring impedances up to 1 MΩ is also incorporated in this SoC. This wireless, low noise ENG acquisition SoC package has been validated in vivo while implanted on a rodent to acquire ENG from its sciatic nerve.
- 7 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 54 (8) , 2266-2280
A Wireless Multi-Channel Peripheral Nerve Signal Acquisition System-on-Chip
The adoption of chronic implantable peripheral nerve-based prosthetic devices is currently hampered by the lack of a highly integrated neural signal acquisition system-on-chip (SoC). We report a ten-channel peripheral nervous system (PNS) electroneurogram (ENG) signal acquisition SoC within an implantable package. Requiring only four off-chip capacitors, this SoC can be co-encapsulated with flexible nerve electrodes and a resonant coil antenna to form a 3.4 cm³ and 3.9 g implantable device for chronic ENG acquisition. This SoC is inductively powered and controlled through a resonant coil at 22 MHz and transmits the digitized neural signal through a near-infrared LED (NIR-LED). Fabricated in 0.18-μm CMOS, each amplifier channel exhibits an input referred noise of 1.9 μVrms and a noise efficiency factor (NEF) of 4.0 within the signal bandwidth of 5.5 kHz. Each amplifier channel within the SoC is digitized with 10-bit resolution at 17.5 ksps, and the total power consumption (SoC and NIR-LED) is 4.4 mW when the NIR-LED is driven at 3 Mb/s. An electrode impedance measurement circuit with <10% magnitude and <8° angle error for measuring impedances up to 1 MΩ is also incorporated in this SoC. This wireless, low noise ENG acquisition SoC package has been validated in vivo while implanted on a rodent to acquire ENG from its sciatic nerve.
- Top Cited Papers
- 9 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 65 (5) , 677-681
Front and Back Illuminated Dynamic and Active Pixel Vision Sensors Comparison
Back side illumination has become standard image sensor technology owing to its superior quantum efficiency and fill factor. A direct comparison of front and back side illumination (FSI and BSI) used in event-based dynamic and active pixel vision sensors (DAVIS) is interesting because of the potential of BSI to greatly increase the small 20% fill factor of these complex pixels. This brief compares identically designed front and back illuminated DAVIS silicon retina vision sensors. They are compared in term of quantum efficiency (QE), leak activity and modulation transfer function (MTF). The BSI DAVIS achieves a peak QE of 93% compared with the FSI DAVIS, peak QE of 24%, but reduced MTF, due to pixel crosstalk and parasitic photocurrent. Significant “leak events” in the BSI DAVIS limit its use to controlled illumination scenarios without very bright light sources. Effects of parasitic photocurrent and modulation transfer functions with and without IR cut filters are also reported.
- 9 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 65 (5) , 677-681
Top Cited PapersFront and Back Illuminated Dynamic and Active Pixel Vision Sensors Comparison
Back side illumination has become standard image sensor technology owing to its superior quantum efficiency and fill factor. A direct comparison of front and back side illumination (FSI and BSI) used in event-based dynamic and active pixel vision sensors (DAVIS) is interesting because of the potential of BSI to greatly increase the small 20% fill factor of these complex pixels. This brief compares identically designed front and back illuminated DAVIS silicon retina vision sensors. They are compared in term of quantum efficiency (QE), leak activity and modulation transfer function (MTF). The BSI DAVIS achieves a peak QE of 93% compared with the FSI DAVIS, peak QE of 24%, but reduced MTF, due to pixel crosstalk and parasitic photocurrent. Significant “leak events” in the BSI DAVIS limit its use to controlled illumination scenarios without very bright light sources. Effects of parasitic photocurrent and modulation transfer functions with and without IR cut filters are also reported.