Ulf Lützen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ulf Lützen has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Maaz Zuhayra
Department of Nuclear Medicine, Molecular Diagnostic Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Campus Kiel, Karl Lennert Cancer Center North, Kiel, Germany
4 shared publications Michael Jüptner
UKSH, Campus Kiel Clinic of Nuclear Medicine, Molecular Imaging and Therapy Kiel Germany
4 shared publications- Yi Zhao
Department of Nuclear Medicine, Molecular Diagnostic, Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Camous Kiel, Karl Lennert Cancer Center North, Kiel, Germany
4 shared publications - Alexander Helm
Department of Nuclear Medicine, Molecular Diagnostic, Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Camous Kiel, Karl Lennert Cancer Center North, Kiel, Germany
3 shared publications - Ammar Alfteimi
Department of Nuclear Medicine, Molecular Diagnostic, Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Camous Kiel, Karl Lennert Cancer Center North, Kiel, Germany
3 shared publications Maaz Zuhayra
UKSH, Campus Kiel Clinic of Nuclear Medicine, Molecular Imaging and Therapy Kiel Germany
3 shared publications
Latest Publications
- Open Access
- 17 February 2026
- Published by Springer Nature in EJNMMI Radiopharmacy and Chemistry
- Vol. 11 (1)
Increasing the activity output and optimization of automated radiosynthesis [68Ga]Ga-DOTATATE, [68Ga]Ga-Pentixafor, and [68Ga]Ga-FAPI-64 using two [68Ge]Ge/[68Ga]Ga iThemba generators in series
Background: The rapidly increasing clinical demand for 68 Ga-labelled radiopharmaceuticals continues to challenge current production capacities, particularly in high-throughput nuclear medicine departments. Although dual-generator concepts have previously been explored, all reported approaches to date have required either pre-purification, fractionated elution, or additional cartridge-based concentration steps, which add complexity and limit routine clinical implementation. In the present study, we report for the first time a fully automated, GMP-compliant synthesis protocol using two iThemba 68 Ge/ 68 Ga generators connected in series on a standard EasyOne module applicable to three clinically relevant tracers. We successfully established robust GMP production of [ 68 Ga]Ga-DOTATATE, [ 68 Ga]Ga-FAPI-46, and [ 68 Ga]Ga-PentixaFor without any pre-purification or fractional elution. A key mechanistic finding of this work is the critical role of direct ascorbic acid addition to the reaction medium, which effectively suppresses radiolysis and metal-ion interference under high-activity conditions. Results: We established a Good Manufacturing Practice (GMP)-compliant, fully automated synthesis of [ 68 Ga]Ga-DOTATATE, [ 68 Ga]Ga-Pentixafor, and [ 68 Ga]Ga-FAPI-46 using two 68 Ge/ 68 Ga iThemba generators connected in series, of which the older generator is replaced with a new one every 6 months. This configuration enabled elution of maximum activity of 3750 MBq and minimum activity of 2345 MBq, exceeding the elution activity achieved with a single generator by 2300 and 901 MBq respectively. The corrected yield of the labelled products was 91 ± 5% (72 ± 5% non-decay corrected). The additional activity of the labeled products obtained through the two generator configuration enables the examination of 2–4 additional patients per batch and thus resulting in significant cost savings. The direct addition of ascorbic acid to the reaction medium was essential, as it suppressed radiolysis and minimized the impact of metallic impurities. This innovation enabled reproducible labeling without pre-purification, which has not previously been demonstrated with SnO 2 -based generators. Conclusions: Dual-generator elution on the EasyOne module without modification of Trasis single-use cassettes provides a robust and scalable approach for high-yield production of 68 Ga radiopharmaceuticals. The integration of series-connected iThemba generators with in-situ radiolysis control by ascorbic acid ensures consistent GMP-compliant synthesis of [ 68 Ga]Ga-DOTATATE, [ 68 Ga]Ga-Pentixafor, and [ 68 Ga]Ga-FAPI-46. This method improves production efficiency, reduces costs, and expands clinical accessibility.
- 17 February 2026
- Published by Springer Nature in EJNMMI Radiopharmacy and Chemistry
- Vol. 11 (1)
Open AccessIncreasing the activity output and optimization of automated radiosynthesis [68Ga]Ga-DOTATATE, [68Ga]Ga-Pentixafor, and [68Ga]Ga-FAPI-64 using two [68Ge]Ge/[68Ga]Ga iThemba generators in series
Background: The rapidly increasing clinical demand for 68 Ga-labelled radiopharmaceuticals continues to challenge current production capacities, particularly in high-throughput nuclear medicine departments. Although dual-generator concepts have previously been explored, all reported approaches to date have required either pre-purification, fractionated elution, or additional cartridge-based concentration steps, which add complexity and limit routine clinical implementation. In the present study, we report for the first time a fully automated, GMP-compliant synthesis protocol using two iThemba 68 Ge/ 68 Ga generators connected in series on a standard EasyOne module applicable to three clinically relevant tracers. We successfully established robust GMP production of [ 68 Ga]Ga-DOTATATE, [ 68 Ga]Ga-FAPI-46, and [ 68 Ga]Ga-PentixaFor without any pre-purification or fractional elution. A key mechanistic finding of this work is the critical role of direct ascorbic acid addition to the reaction medium, which effectively suppresses radiolysis and metal-ion interference under high-activity conditions. Results: We established a Good Manufacturing Practice (GMP)-compliant, fully automated synthesis of [ 68 Ga]Ga-DOTATATE, [ 68 Ga]Ga-Pentixafor, and [ 68 Ga]Ga-FAPI-46 using two 68 Ge/ 68 Ga iThemba generators connected in series, of which the older generator is replaced with a new one every 6 months. This configuration enabled elution of maximum activity of 3750 MBq and minimum activity of 2345 MBq, exceeding the elution activity achieved with a single generator by 2300 and 901 MBq respectively. The corrected yield of the labelled products was 91 ± 5% (72 ± 5% non-decay corrected). The additional activity of the labeled products obtained through the two generator configuration enables the examination of 2–4 additional patients per batch and thus resulting in significant cost savings. The direct addition of ascorbic acid to the reaction medium was essential, as it suppressed radiolysis and minimized the impact of metallic impurities. This innovation enabled reproducible labeling without pre-purification, which has not previously been demonstrated with SnO 2 -based generators. Conclusions: Dual-generator elution on the EasyOne module without modification of Trasis single-use cassettes provides a robust and scalable approach for high-yield production of 68 Ga radiopharmaceuticals. The integration of series-connected iThemba generators with in-situ radiolysis control by ascorbic acid ensures consistent GMP-compliant synthesis of [ 68 Ga]Ga-DOTATATE, [ 68 Ga]Ga-Pentixafor, and [ 68 Ga]Ga-FAPI-46. This method improves production efficiency, reduces costs, and expands clinical accessibility.
- Open Access
- 26 June 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (8) , e14077
Evaluation of sentinel lymph node localization in malignant melanoma by preoperative semiconductor gamma camera and planar lymphoscintigraphy
Introduction: Performing lymphoscintigraphy in a separate room, frees up the conventional gamma camera, coupled with the desire to directly localize sentinel lymph nodes (SLN) in the operating theatre has led to the development of high‐resolution semiconductor‐detector based handheld gamma‐cameras, CrystalCam.Methods: This work consists of phantom and clinical studies. For the first part, a Jaszczak phantom with hollow spheres of various volumes were filled with the 99mTc and the camera's sensitivity was measured at various distances to assess the possibilities and limitations of the device. The clinical study evaluates the effectiveness of CrystalCam in localizing SLN in 40 consecutive malignant melanoma patients compared to both conventional planar lymphoscintigraphy and hybrid SPECT/CT. SLNs detected by planar lymphoscintigraphy were marked on the patients’ skin using a UV‐marker. CrystalCam images were acquired in another room by another examiner and the SLNs were marked with a felt pen. The detected nodes by both camera systems were evaluated using UV‐lamp and normal light to visualize the UV‐ and felt pen marks respectively. The concordance rate of the SLNs and higher‐echelon nodes localized by both planar scintigraphy and CrystalCam imaging with respect to the total SLNs and higher‐echelon nodes detected by SPECT/CT imaging are compared and statistically analyzed.Results: The results of the phantom study show a good correlation between activity and count‐rates for all distancesSPECT/CT, CrystalCamm, and planar lymphoscintigraphy detected 69, 58, and 61 SLNs respectively. The concordance rate of 95.65% by the CrystalCam and planar scintigraphy implies both cameras are statistically coequal in preoperative SLN detection of malignant melanoma. For the higher‐echelon nodes, SPECT/CT, planar and CrystalCam imaging systems identified 82, 48, and 13 respectively; thus, CrystalCam was statistically inferior to planar imaging.Conclusion: The handheld CrystalCam is a reliable instrument for localizing SLNs in surgical centers without an on‐site nuclear medicine department.
- 26 June 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (8) , e14077
Open AccessEvaluation of sentinel lymph node localization in malignant melanoma by preoperative semiconductor gamma camera and planar lymphoscintigraphy
Introduction: Performing lymphoscintigraphy in a separate room, frees up the conventional gamma camera, coupled with the desire to directly localize sentinel lymph nodes (SLN) in the operating theatre has led to the development of high‐resolution semiconductor‐detector based handheld gamma‐cameras, CrystalCam.Methods: This work consists of phantom and clinical studies. For the first part, a Jaszczak phantom with hollow spheres of various volumes were filled with the 99mTc and the camera's sensitivity was measured at various distances to assess the possibilities and limitations of the device. The clinical study evaluates the effectiveness of CrystalCam in localizing SLN in 40 consecutive malignant melanoma patients compared to both conventional planar lymphoscintigraphy and hybrid SPECT/CT. SLNs detected by planar lymphoscintigraphy were marked on the patients’ skin using a UV‐marker. CrystalCam images were acquired in another room by another examiner and the SLNs were marked with a felt pen. The detected nodes by both camera systems were evaluated using UV‐lamp and normal light to visualize the UV‐ and felt pen marks respectively. The concordance rate of the SLNs and higher‐echelon nodes localized by both planar scintigraphy and CrystalCam imaging with respect to the total SLNs and higher‐echelon nodes detected by SPECT/CT imaging are compared and statistically analyzed.Results: The results of the phantom study show a good correlation between activity and count‐rates for all distancesSPECT/CT, CrystalCamm, and planar lymphoscintigraphy detected 69, 58, and 61 SLNs respectively. The concordance rate of 95.65% by the CrystalCam and planar scintigraphy implies both cameras are statistically coequal in preoperative SLN detection of malignant melanoma. For the higher‐echelon nodes, SPECT/CT, planar and CrystalCam imaging systems identified 82, 48, and 13 respectively; thus, CrystalCam was statistically inferior to planar imaging.Conclusion: The handheld CrystalCam is a reliable instrument for localizing SLNs in surgical centers without an on‐site nuclear medicine department.
- 9 August 2022
- Published by Georg Thieme Verlag KG in Nuklearmedizin-Nuclear Medicine
- Vol. 61 (05) , 410-413
Unusual accumulation of 177Lu-DOTATATE at the injection site of a COVID-19 vaccination
Received: 10 January 2022 Accepted after revision: 12 May 2022 Article published online: 09 August 2022 © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 9 August 2022
- Published by Georg Thieme Verlag KG in Nuklearmedizin-Nuclear Medicine
- Vol. 61 (05) , 410-413
Unusual accumulation of 177Lu-DOTATATE at the injection site of a COVID-19 vaccination
Received: 10 January 2022 Accepted after revision: 12 May 2022 Article published online: 09 August 2022 © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- Open Access
- 29 July 2022
- Published by Springer Nature in EJNMMI Radiopharmacy and Chemistry
- Vol. 7 (1) , 1-16
Automated synthesis of [68Ga]Ga-FAPI-46 without pre-purification of the generator eluate on three common synthesis modules and two generator types
Background: The recent development of quinoline-based radiotracers, which act as fibroblast activation protein inhibitors (FAPIs), has shown promising preclinical and clinical advantages. [68Ga]Ga-FAPI-46 is a new radiotracer for in vivo detection of the fibroblast activation protein by positron emission tomography (PET). Recently, the automated synthesis of [68Ga]Ga-FAPI-46 was reported based on pre-concentration and purification of the generator eluate by using a cation exchange-cartridge. Our aim was to simplify the synthesis and shorten the automated synthesis of [68Ga]Ga-FAPI-46 to make it accessible and thus even more attractive to a broader clinical and scientific community. Results: We developed and evaluated the GMP compliant automatic synthesis of [68Ga]Ga-FAPI-46 using two different 68Ge/68Ga generators (an Eckert & Ziegler, GalliaPharm generator, 1.85 GBq/50 mCi and an iThemba generator, 1.85 GBq/50 mCi) Somerset West, South Africa) and three different commercial and customized systems: the EasyOne module from Trasis; the GaSy module from Synthra with a customized synthesis template and a customized single use cassette. Additionally, the automatic synthesis of [68Ga]Ga-FAPI-46 was established on a GallElut synthesis module from Scintomics with fixed tubing. Conclusions: Independent of the synthesis modules or the generators employed we were able to complete the synthesis of [68Ga]Ga-FAPI-46 in 12 min including the process of purification and formulation. In all cases, the final products showed more than 99.5% chemical purity and the radiochemical yield reached around 92.5% (decay corrected). All quality control parameters (e.g. sterility, stability and radiochemical purity) were conform to the European Pharmacopoeia.
- 29 July 2022
- Published by Springer Nature in EJNMMI Radiopharmacy and Chemistry
- Vol. 7 (1) , 1-16
Open AccessAutomated synthesis of [68Ga]Ga-FAPI-46 without pre-purification of the generator eluate on three common synthesis modules and two generator types
Background: The recent development of quinoline-based radiotracers, which act as fibroblast activation protein inhibitors (FAPIs), has shown promising preclinical and clinical advantages. [68Ga]Ga-FAPI-46 is a new radiotracer for in vivo detection of the fibroblast activation protein by positron emission tomography (PET). Recently, the automated synthesis of [68Ga]Ga-FAPI-46 was reported based on pre-concentration and purification of the generator eluate by using a cation exchange-cartridge. Our aim was to simplify the synthesis and shorten the automated synthesis of [68Ga]Ga-FAPI-46 to make it accessible and thus even more attractive to a broader clinical and scientific community. Results: We developed and evaluated the GMP compliant automatic synthesis of [68Ga]Ga-FAPI-46 using two different 68Ge/68Ga generators (an Eckert & Ziegler, GalliaPharm generator, 1.85 GBq/50 mCi and an iThemba generator, 1.85 GBq/50 mCi) Somerset West, South Africa) and three different commercial and customized systems: the EasyOne module from Trasis; the GaSy module from Synthra with a customized synthesis template and a customized single use cassette. Additionally, the automatic synthesis of [68Ga]Ga-FAPI-46 was established on a GallElut synthesis module from Scintomics with fixed tubing. Conclusions: Independent of the synthesis modules or the generators employed we were able to complete the synthesis of [68Ga]Ga-FAPI-46 in 12 min including the process of purification and formulation. In all cases, the final products showed more than 99.5% chemical purity and the radiochemical yield reached around 92.5% (decay corrected). All quality control parameters (e.g. sterility, stability and radiochemical purity) were conform to the European Pharmacopoeia.
- Open Access
- 4 July 2022
- Published by Springer Nature in BMC Urology
- Vol. 22 (1) , 1-8
Pre- and intratherapeutic predictors of overall survival in patients with advanced metastasized castration-resistant prostate cancer receiving Lu-177-PSMA-617 radioligand therapy
Background: Systemic Lutetium-177 prostate-specific membrane antigen-617 radioligand therapy (Lu-177-PSMA-617-RLT) is a novel treatment approach in patients suffering from metastasized castration-resistant prostate cancer. Nonetheless, a therapeutic response may fail to appear in a proportion of patients. This study aims to identify routinely obtainable pre- and intratherapeutic parameters to allow a prediction of overall survival in patients receiving Lu-177-PSMA-617 radioligand therapy. Methods: Between January 2015 and December 2020 52 patients treated with a total of 146 cycles Lu-177-PSMA-617-RLT were retrospectively analysed in a single-center trial. The median overall survival time (OS) was compared to pre-therapeutic serological parameters, the extend of metastatic spread and previously performed therapies using Kaplan–Meier estimators and multivariate Cox-regression. Bonferroni-Holm correction was performed on all statistical tests. Results: The median OS of all patients was 55.6 weeks. Multivariate Cox-regression revealed significant lower survival for decreased pretherapeutic hemoglobin levels (HR 0.698 per g/dl; 95%-CI 0.560–0.872; p = 0.001), increased lactate dehydrogenase (LDH) levels (HR 1.073 per 25 U/l; 95%-CI 1.024–1.125; p = 0.003) and the presence of hepatic metastasis (HR 6.981; 95%-CI 2.583–18.863; p < 0.001). Increased pretherapeutic c-reactive protein (CRP), alkaline phosphatase (ALP) and gamma-glutamyltransferase (GGT) levels were also associated with a shorter survival. A prostate-specific antigen decline after one therapy cycle did not significantly correlate with an increased survival. No significant relations were observed between overall survival time and other serological parameters or previously performed therapies. Conclusion: Pre-therapeutic hemoglobin and LDH levels, as well as the presence of hepatic metastasis are independent predictors of overall survival in patients receiving Lu-177-PSMA-617-RLT. CRP, ALP and GGT levels cloud be utilized as additional decision aids when a Lu-177-PSMA-617-RLT is intended. Trial Registration Not applicable (retrospective observational study).
- 4 July 2022
- Published by Springer Nature in BMC Urology
- Vol. 22 (1) , 1-8
Open AccessPre- and intratherapeutic predictors of overall survival in patients with advanced metastasized castration-resistant prostate cancer receiving Lu-177-PSMA-617 radioligand therapy
Background: Systemic Lutetium-177 prostate-specific membrane antigen-617 radioligand therapy (Lu-177-PSMA-617-RLT) is a novel treatment approach in patients suffering from metastasized castration-resistant prostate cancer. Nonetheless, a therapeutic response may fail to appear in a proportion of patients. This study aims to identify routinely obtainable pre- and intratherapeutic parameters to allow a prediction of overall survival in patients receiving Lu-177-PSMA-617 radioligand therapy. Methods: Between January 2015 and December 2020 52 patients treated with a total of 146 cycles Lu-177-PSMA-617-RLT were retrospectively analysed in a single-center trial. The median overall survival time (OS) was compared to pre-therapeutic serological parameters, the extend of metastatic spread and previously performed therapies using Kaplan–Meier estimators and multivariate Cox-regression. Bonferroni-Holm correction was performed on all statistical tests. Results: The median OS of all patients was 55.6 weeks. Multivariate Cox-regression revealed significant lower survival for decreased pretherapeutic hemoglobin levels (HR 0.698 per g/dl; 95%-CI 0.560–0.872; p = 0.001), increased lactate dehydrogenase (LDH) levels (HR 1.073 per 25 U/l; 95%-CI 1.024–1.125; p = 0.003) and the presence of hepatic metastasis (HR 6.981; 95%-CI 2.583–18.863; p < 0.001). Increased pretherapeutic c-reactive protein (CRP), alkaline phosphatase (ALP) and gamma-glutamyltransferase (GGT) levels were also associated with a shorter survival. A prostate-specific antigen decline after one therapy cycle did not significantly correlate with an increased survival. No significant relations were observed between overall survival time and other serological parameters or previously performed therapies. Conclusion: Pre-therapeutic hemoglobin and LDH levels, as well as the presence of hepatic metastasis are independent predictors of overall survival in patients receiving Lu-177-PSMA-617-RLT. CRP, ALP and GGT levels cloud be utilized as additional decision aids when a Lu-177-PSMA-617-RLT is intended. Trial Registration Not applicable (retrospective observational study).
- Open Access
- 17 March 2022
- Published by Elsevier in Physica Medica
- Vol. 96, 157-165
A simple, reliable and accurate approach for assessing [131I]-capsule activity leading to significant reduction of radiation exposure of medical staff during radioiodine therapy
- 17 March 2022
- Published by Elsevier in Physica Medica
- Vol. 96, 157-165
Open AccessA simple, reliable and accurate approach for assessing [131I]-capsule activity leading to significant reduction of radiation exposure of medical staff during radioiodine therapy
- Open Access
- 20 August 2021
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 22 (16) , 9010
Photopharmacological Applications for Cherenkov Radiation Generated by Clinically Used Radionuclides
Translational photopharmacological applications are limited through irradiation by light showing wavelengths within the bio-optical window. To achieve sufficient tissue penetration, using wavelengths >500 nm is mandatory. Nevertheless, the majority of photopharmacological compounds respond to irradiation with more energetic UV light, which shows only a minor depth of tissue penetration in the µm range. Thus, we became interested in UV light containing Cherenkov radiation (CR) induced as a by-product by clinically employed radionuclides labeling specific tissues. Therefore, CR may be applicable in novel photopharmacological approaches. To provide evidence for the hypothesis, we verified the clinically established radionuclides 68Ga and 90Y but not 18F in clinically used activities to be capable of generating CR in aqueous solutions. We then investigated whether the generated CR was able to photoactivate the caged kinase inhibitor cagedAZD5438 as a photoresponsive model system. Herein, 21% uncaging of the model system cagedAZD5438 occurred by incubation with 90Y, along with a non-specific compound decomposition for 68Ga and partly for 90Y. The findings suggest that the combination of a clinically employed radionuclide with an optimized photoresponsive agent could be beneficial for highly focused photopharmacological therapies.
- 20 August 2021
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 22 (16) , 9010
Open AccessPhotopharmacological Applications for Cherenkov Radiation Generated by Clinically Used Radionuclides
Translational photopharmacological applications are limited through irradiation by light showing wavelengths within the bio-optical window. To achieve sufficient tissue penetration, using wavelengths >500 nm is mandatory. Nevertheless, the majority of photopharmacological compounds respond to irradiation with more energetic UV light, which shows only a minor depth of tissue penetration in the µm range. Thus, we became interested in UV light containing Cherenkov radiation (CR) induced as a by-product by clinically employed radionuclides labeling specific tissues. Therefore, CR may be applicable in novel photopharmacological approaches. To provide evidence for the hypothesis, we verified the clinically established radionuclides 68Ga and 90Y but not 18F in clinically used activities to be capable of generating CR in aqueous solutions. We then investigated whether the generated CR was able to photoactivate the caged kinase inhibitor cagedAZD5438 as a photoresponsive model system. Herein, 21% uncaging of the model system cagedAZD5438 occurred by incubation with 90Y, along with a non-specific compound decomposition for 68Ga and partly for 90Y. The findings suggest that the combination of a clinically employed radionuclide with an optimized photoresponsive agent could be beneficial for highly focused photopharmacological therapies.
- 28 May 2019
- Published by Georg Thieme Verlag KG in Nuklearmedizin-Nuclear Medicine
- Vol. 58 (04) , 328-330
Experimental 177Lu-PSMA-617 radioligand therapy in a patient with extended metastasized leiomyosarcoma
Systemic radionuclide therapy with 177Lu-PSMA-617 is a novel treatment option in patients with metastasized and castration-resistant prostate cancer [4]. The molecular target of the 177Lu-PSMA-617 radioligand therapy is the prostate-specific membrane antigen (PSMA) highly expressed on prostate cancer cells. Beyond the enhanced accumulation of PSMA on prostate cancer cells, PSMA expression is also found on the molecular surface or in the tumor-associated neovasculature of various tumor tissues including sarcomas of the soft tissue [2]. Thus, PSMA has theoretically been discussed as a possible future target for systemic radioligand therapy with 177Lu-PSMA-617 even in non-prostate malignancies [1]. Here we report on a female patient with extended metastasized leiomyosarcoma experimentally treated with one application of 177Lu-PSMA-617 radioligand therapy.
- 28 May 2019
- Published by Georg Thieme Verlag KG in Nuklearmedizin-Nuclear Medicine
- Vol. 58 (04) , 328-330
Experimental 177Lu-PSMA-617 radioligand therapy in a patient with extended metastasized leiomyosarcoma
Systemic radionuclide therapy with 177Lu-PSMA-617 is a novel treatment option in patients with metastasized and castration-resistant prostate cancer [4]. The molecular target of the 177Lu-PSMA-617 radioligand therapy is the prostate-specific membrane antigen (PSMA) highly expressed on prostate cancer cells. Beyond the enhanced accumulation of PSMA on prostate cancer cells, PSMA expression is also found on the molecular surface or in the tumor-associated neovasculature of various tumor tissues including sarcomas of the soft tissue [2]. Thus, PSMA has theoretically been discussed as a possible future target for systemic radioligand therapy with 177Lu-PSMA-617 even in non-prostate malignancies [1]. Here we report on a female patient with extended metastasized leiomyosarcoma experimentally treated with one application of 177Lu-PSMA-617 radioligand therapy.