YZYi Zhao

Yi Zhao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yi Zhao has a total of 33 co-authors. Here are the top co-authors by number of shared publications:

  • Maaz Zuhayra

    Department of Nuclear Medicine, Molecular Diagnostic Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Campus Kiel, Karl Lennert Cancer Center North, Kiel, Germany

    7 shared publications
  • Michael Jüptner

    Department of Nuclear Medicine, Molecular Diagnostic, Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Camous Kiel, Karl Lennert Cancer Center North, Kiel, Germany

    5 shared publications
  • Ulf Lützen

    Department of Nuclear Medicine, Molecular Diagnostic, Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Camous Kiel, Karl Lennert Cancer Center North, Kiel, Germany

    4 shared publications
  • Alexander Helm

    Department of Nuclear Medicine, Molecular Diagnostic, Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Camous Kiel, Karl Lennert Cancer Center North, Kiel, Germany

    3 shared publications
  • Ammar Alfteimi

    Department of Nuclear Medicine, Molecular Diagnostic, Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Camous Kiel, Karl Lennert Cancer Center North, Kiel, Germany

    3 shared publications
  • Ulf Lützen

    Department of Nuclear Medicine, Molecular Imaging Diagnostics and Therapy, University Hospital Schleswig Holstein, Kiel, Germany

    3 shared publications

Latest Publications

  • Open Access

    Increasing the activity output and optimization of automated radiosynthesis [68Ga]Ga-DOTATATE, [68Ga]Ga-Pentixafor, and [68Ga]Ga-FAPI-64 using two [68Ge]Ge/[68Ga]Ga iThemba generators in series

    by Ammar Alfteimi, Ulf Lützen, Alexander Helm, Michael Jüptner, Yi Zhao, Maaz Zuhayra

    Background: The rapidly increasing clinical demand for 68 Ga-labelled radiopharmaceuticals continues to challenge current production capacities, particularly in high-throughput nuclear medicine departments. Although dual-generator concepts have previously been explored, all reported approaches to date have required either pre-purification, fractionated elution, or additional cartridge-based concentration steps, which add complexity and limit routine clinical implementation. In the present study, we report for the first time a fully automated, GMP-compliant synthesis protocol using two iThemba 68 Ge/ 68 Ga generators connected in series on a standard EasyOne module applicable to three clinically relevant tracers. We successfully established robust GMP production of [ 68 Ga]Ga-DOTATATE, [ 68 Ga]Ga-FAPI-46, and [ 68 Ga]Ga-PentixaFor without any pre-purification or fractional elution. A key mechanistic finding of this work is the critical role of direct ascorbic acid addition to the reaction medium, which effectively suppresses radiolysis and metal-ion interference under high-activity conditions. Results: We established a Good Manufacturing Practice (GMP)-compliant, fully automated synthesis of [ 68 Ga]Ga-DOTATATE, [ 68 Ga]Ga-Pentixafor, and [ 68 Ga]Ga-FAPI-46 using two 68 Ge/ 68 Ga iThemba generators connected in series, of which the older generator is replaced with a new one every 6 months. This configuration enabled elution of maximum activity of 3750 MBq and minimum activity of 2345 MBq, exceeding the elution activity achieved with a single generator by 2300 and 901 MBq respectively. The corrected yield of the labelled products was 91 ± 5% (72 ± 5% non-decay corrected). The additional activity of the labeled products obtained through the two generator configuration enables the examination of 2–4 additional patients per batch and thus resulting in significant cost savings. The direct addition of ascorbic acid to the reaction medium was essential, as it suppressed radiolysis and minimized the impact of metallic impurities. This innovation enabled reproducible labeling without pre-purification, which has not previously been demonstrated with SnO 2 -based generators. Conclusions: Dual-generator elution on the EasyOne module without modification of Trasis single-use cassettes provides a robust and scalable approach for high-yield production of 68 Ga radiopharmaceuticals. The integration of series-connected iThemba generators with in-situ radiolysis control by ascorbic acid ensures consistent GMP-compliant synthesis of [ 68 Ga]Ga-DOTATATE, [ 68 Ga]Ga-Pentixafor, and [ 68 Ga]Ga-FAPI-46. This method improves production efficiency, reduces costs, and expands clinical accessibility.


  • Open Access

    PSMA-617 inhibits proliferation and potentiates the 177Lu-PSMA-617-induced death of human prostate cancer cells

    by Yi Zhao, Juraj Culman, Ingolf Cascorbi, Niklas Nithack, Marlies Marx, Maaz Zuhayra, Ulf Lützen

    The human prostate–specific membrane antigen (PSMA) is substantially up-regulated in metastatic prostate cancer (PCa) cells. PSMA can be targeted by 177Lu conjugated to PSMA-617, a high-affinity ligand for the PSMA. The binding of the radioligand, 177Lu-PSMA-617, results in its internalisation and delivery of β-radiation into the cancer cells. However, PSMA-617, a component of the final product in the synthesis of the radioligand, may also play a role in the pathophysiology of PCa cells. The present study aimed to clarify the effects of PSMA-617 (10, 50 and 100 nM) on the expression of PSMA in PSMA-positive LNCaP cells, their proliferation, 177Lu-PSMA-617-induced cell death by WST-1 and lactate dehydrogenase assays, immunohistochemistry, western blotting, immunofluorescence staining and uptake of 177Lu-PSMA-617. PSMA-617 at 100 nM concentration induced cell-growth arrest, down-regulated cyclin D1 and cyclin E1 (by 43 and 36%, respectively) and up-regulated the cyclin-dependent kinase inhibitor p21Waf1/Cip1 (by 48%). Immunofluorescence staining demonstrated reduced content of DNA, pointing to a lower rate of cell division. PSMA-617 (up to 100 nM) did not alter the uptake of 177Lu-PSMA-617 into the LNCaP cells. Interestingly, simultaneous treatment with 177Lu-PSMA-617 and PSMA-617 for 24 and 48 h substantially potentiated the cell-death promoting effects of the radioligand. In conclusion, the combination of impeding tumour cell proliferation by PSMA-617 and its potentiation of the radiation-induced cell death brought about by 177Lu-PSMA-617 in PCa cells may considerably improve the outcome of the radiation therapy with 177Lu-PSMA-617, especially in patients with decreased radiosensitivity of PCa cells to the radioligand.


  • Open Access

    Automated synthesis of [68Ga]Ga-FAPI-46 without pre-purification of the generator eluate on three common synthesis modules and two generator types

    by Ammar Alfteimi, Ulf Lützen, Alexander Helm, Michael Jüptner, Marlies Marx, Yi Zhao, Maaz Zuhayra

    Background: The recent development of quinoline-based radiotracers, which act as fibroblast activation protein inhibitors (FAPIs), has shown promising preclinical and clinical advantages. [68Ga]Ga-FAPI-46 is a new radiotracer for in vivo detection of the fibroblast activation protein by positron emission tomography (PET). Recently, the automated synthesis of [68Ga]Ga-FAPI-46 was reported based on pre-concentration and purification of the generator eluate by using a cation exchange-cartridge. Our aim was to simplify the synthesis and shorten the automated synthesis of [68Ga]Ga-FAPI-46 to make it accessible and thus even more attractive to a broader clinical and scientific community. Results: We developed and evaluated the GMP compliant automatic synthesis of [68Ga]Ga-FAPI-46 using two different 68Ge/68Ga generators (an Eckert & Ziegler, GalliaPharm generator, 1.85 GBq/50 mCi and an iThemba generator, 1.85 GBq/50 mCi) Somerset West, South Africa) and three different commercial and customized systems: the EasyOne module from Trasis; the GaSy module from Synthra with a customized synthesis template and a customized single use cassette. Additionally, the automatic synthesis of [68Ga]Ga-FAPI-46 was established on a GallElut synthesis module from Scintomics with fixed tubing. Conclusions: Independent of the synthesis modules or the generators employed we were able to complete the synthesis of [68Ga]Ga-FAPI-46 in 12 min including the process of purification and formulation. In all cases, the final products showed more than 99.5% chemical purity and the radiochemical yield reached around 92.5% (decay corrected). All quality control parameters (e.g. sterility, stability and radiochemical purity) were conform to the European Pharmacopoeia.


  • Open Access

    PSMA-617 inhibits proliferation of human prostate cancer cells and enhances their radiosensitivity to 177Lu-PSMA-617

    by Yi Zhao, Juraj Culman, Niklas Nithack, Marlies Marx, Ingolf Cascorbi, Maaz Zuhayra, Ulf Lützen

    The human prostate – specific membrane antigen (PSMA) is substantially up-regulated in metastatic prostate cancer (PCa) cells. PSMA can be targeted by 177Lu conjugated to PSMA-617, a high-affinity ligand for the PSMA. The binding of the radioligand, 177Lu-PSMA-617, results in its internalization and delivery of β-radiation into the cancer cells. However, PSMA-617, a component of the final product in the synthesis of the radioligand, may also play a role in the pathophysiology of PCa cells. The present study clarifies the effects of PSMA-617 (10, 50 and 100 nM) on the expression of PSMA in PSMA-positive LNCaP cells, their proliferation and damage, and on the 177Lu-PSMA-617-induced cell death by WST-1 and lactate dehydrogenase assays, immunohistochemistry, Western blotting, immunofluorescence staining and uptake of 177Lu-PSMA-617. PSMA-617 at 100 nM concentration induced cell-growth arrest, down-regulated cyclin D1 and cyclin E1 (by 43 and 36 %, respectively) and up-regulated the cyclin-dependent kinase inhibitor p21Waf1/Cip1 (by 48 %). Immunofluorescence staining demonstrated reduced content of DNA, pointing to a lower rate of cell division. PSMA-617 (up to 100 nM) did not alter the uptake of 177Lu-PSMA-617 into the LNCaP cells. Interestingly, simultaneous treatment with 177Lu-PSMA-617 and PSMA-617 for 24 and 48 h substantially potentiated the cell-death promoting effects of the radioligand. In conclusion, the impeding tumour cell proliferation by PSMA-617 and its potentiation of the radiation-induced cell death brought about by 177Lu-PSMA-617 in PCa cells may considerably improve the outcome of the radiation therapy with 177Lu-PSMA-617, especially in patients with decreased radiosensitivity of PCa cells to the radioligand.

  • Open Access

    A simple, reliable and accurate approach for assessing [131I]-capsule activity leading to significant reduction of radiation exposure of medical staff during radioiodine therapy

    by Maaz Zuhayra, Alexander Helm, Joshua Ranjan, Michael Jüptner, Yi Zhao, Marlies Marx, Isong Assam, Ammar Alfteimi, Ulf Lützen

  • Open Access

    Photopharmacological Applications for Cherenkov Radiation Generated by Clinically Used Radionuclides

    by Melanie Krebs, Alexander Döbber, Theo Rodat, Ulf Lützen, Yi Zhao, Maaz Zuhayra, Christian Peifer

    Translational photopharmacological applications are limited through irradiation by light showing wavelengths within the bio-optical window. To achieve sufficient tissue penetration, using wavelengths >500 nm is mandatory. Nevertheless, the majority of photopharmacological compounds respond to irradiation with more energetic UV light, which shows only a minor depth of tissue penetration in the µm range. Thus, we became interested in UV light containing Cherenkov radiation (CR) induced as a by-product by clinically employed radionuclides labeling specific tissues. Therefore, CR may be applicable in novel photopharmacological approaches. To provide evidence for the hypothesis, we verified the clinically established radionuclides 68Ga and 90Y but not 18F in clinically used activities to be capable of generating CR in aqueous solutions. We then investigated whether the generated CR was able to photoactivate the caged kinase inhibitor cagedAZD5438 as a photoresponsive model system. Herein, 21% uncaging of the model system cagedAZD5438 occurred by incubation with 90Y, along with a non-specific compound decomposition for 68Ga and partly for 90Y. The findings suggest that the combination of a clinically employed radionuclide with an optimized photoresponsive agent could be beneficial for highly focused photopharmacological therapies.


  • Open Access

    A study on the value of computer-assisted assessment for SPECT/CT-scans in sentinel lymph node diagnostics of penile cancer as well as clinical reliability and morbidity of this procedure

    by Ulf Lützen, Carsten Maik Naumann, Marlies Marx, Yi Zhao, Michael Jüptner, René Baumann, László Papp, Norbert Zsótér, Alexey Aksenov, Klaus-Peter Jünemann, et al.

    Because of the increasing importance of computer-assisted post processing of image data in modern medical diagnostic we studied the value of an algorithm for assessment of single photon emission computed tomography/computed tomography (SPECT/CT)-data, which has been used for the first time for lymph node staging in penile cancer with non-palpable inguinal lymph nodes. In the guidelines of the relevant international expert societies, sentinel lymph node-biopsy (SLNB) is recommended as a diagnostic method of choice. The aim of this study is to evaluate the value of the afore-mentioned algorithm and in the clinical context the reliability and the associated morbidity of this procedure. Between 2008 and 2015, 25 patients with invasive penile cancer and inconspicuous inguinal lymph node status underwent SLNB after application of the radiotracer Tc-99m labelled nanocolloid. We recorded in a prospective approach the reliability and the complication rate of the procedure. In addition, we evaluated the results of an algorithm for SPECT/CT-data assessment of these patients. SLNB was carried out in 44 groins of 25 patients. In three patients, inguinal lymph node metastases were detected via SLNB. In one patient, bilateral lymph node recurrence of the groins occurred after negative SLNB. There was a false-negative rate of 4 % in relation to the number of patients (1/25), resp. 4.5 % in relation to the number of groins (2/44). Morbidity was 4 % in relation to the number of patients (1/25), resp. 2.3 % in relation to the number of groins (1/44). The results of computer-assisted assessment of SPECT/CT data for sentinel lymph node (SLN)-diagnostics demonstrated high sensitivity of 88.8 % and specificity of 86.7 %. SLNB is a very reliable method, associated with low morbidity. Computer-assisted assessment of SPECT/CT data of the SLN-diagnostics shows high sensitivity and specificity. While it cannot replace the assessment by medical experts, it can still provide substantial supplement and assistance.


  • Open Access

    10-Year experience regarding the reliability and morbidity of radio guided lymph node biopsy in penile cancer patients and the associated radiation exposure of medical staff in this procedure

    by Ulf Lützen, Carsten Maik Naumann, Jens Dischinger, Marlies Marx, René Baumann, Yi Zhao, Michael Jüptner, Daniar Osmonov, Katrin Bothe, Klaus-Peter Jünemann, et al.

    The guidelines of the European Association of Urologists (EAU), of the German Society of Nuclear Medicine (DGN), and the European Society for Medical Oncology (ESMO) recommend sentinel lymph node biopsy (SLNB) for lymph node staging in penile cancer with non-palpable inguinal lymph nodes as one diagnostic method. Despite this, the method is neither widely nor regularly applied in Germany – the same applies to many other countries, which may be due to insecurity in dealing with open radioactive tracers. This study aims to assess the reliability and morbidity of this method, as well as the associated radioactive burden for clinical staff. Between 2006 and 2016, 34 patients with an invasive penile carcinoma and inconspicuous inguinal lymph node status underwent SLNB in 57 groins after application of a radiotracer (Tc-99 m nanocolloid). We collected the results prospectively. The reliability of the method was assessed by determining the false-negative rate. In addition, we evaluated complication rates and determined the radioactive burden for the clinical staff both pre- and intraoperatively. SLNB was performed in 34 patients with penile cancer with non-palpable inguinal lymph nodes in 57 groins. In two patients inguinal lymph node metastases were detected by means of SLNB. In one patient recurrent inguinal lymph node disease was found after negative SLNB in both groins. Thus, the false negative rate was 3.13 % per patient (1/32 patients) and 3.51 % per groin (2/57 groins). The morbidity rate was 2.94 % per patient (1/34 patients) and 1.75 % per groin (1/57 groins). Radiation exposure for the clinical staff during this procedure was low at a maximum of ca. four μSV per intervention. SLNB is a reliable method with low morbidity that is associated with a low radiation burden for clinical staff. Due to the enhanced methodological and logistic demands, this intervention should be performed in specialized centres and in an interdisciplinary approach.