Ammar Alfteimi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ammar Alfteimi has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Helm
Department of Nuclear Medicine, Molecular Diagnostic, Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Camous Kiel, Karl Lennert Cancer Center North, Kiel, Germany
3 shared publications - Maaz Zuhayra
Department of Nuclear Medicine, Molecular Diagnostic Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Campus Kiel, Karl Lennert Cancer Center North, Kiel, Germany
3 shared publications - Michael Jüptner
Department of Nuclear Medicine, Molecular Diagnostic, Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Camous Kiel, Karl Lennert Cancer Center North, Kiel, Germany
3 shared publications - Ulf Lützen
Department of Nuclear Medicine, Molecular Diagnostic, Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Camous Kiel, Karl Lennert Cancer Center North, Kiel, Germany
3 shared publications - Yi Zhao
Department of Nuclear Medicine, Molecular Diagnostic, Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Camous Kiel, Karl Lennert Cancer Center North, Kiel, Germany
3 shared publications - Marlies Marx
Department of Nuclear Medicine, Molecular Diagnostic Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Campus Kiel, Karl Lennert Cancer Center North, Kiel, Germany
2 shared publications
Latest Publications
- Open Access
- 17 February 2026
- Published by Springer Nature in EJNMMI Radiopharmacy and Chemistry
- Vol. 11 (1)
Increasing the activity output and optimization of automated radiosynthesis [68Ga]Ga-DOTATATE, [68Ga]Ga-Pentixafor, and [68Ga]Ga-FAPI-64 using two [68Ge]Ge/[68Ga]Ga iThemba generators in series
Background: The rapidly increasing clinical demand for 68 Ga-labelled radiopharmaceuticals continues to challenge current production capacities, particularly in high-throughput nuclear medicine departments. Although dual-generator concepts have previously been explored, all reported approaches to date have required either pre-purification, fractionated elution, or additional cartridge-based concentration steps, which add complexity and limit routine clinical implementation. In the present study, we report for the first time a fully automated, GMP-compliant synthesis protocol using two iThemba 68 Ge/ 68 Ga generators connected in series on a standard EasyOne module applicable to three clinically relevant tracers. We successfully established robust GMP production of [ 68 Ga]Ga-DOTATATE, [ 68 Ga]Ga-FAPI-46, and [ 68 Ga]Ga-PentixaFor without any pre-purification or fractional elution. A key mechanistic finding of this work is the critical role of direct ascorbic acid addition to the reaction medium, which effectively suppresses radiolysis and metal-ion interference under high-activity conditions. Results: We established a Good Manufacturing Practice (GMP)-compliant, fully automated synthesis of [ 68 Ga]Ga-DOTATATE, [ 68 Ga]Ga-Pentixafor, and [ 68 Ga]Ga-FAPI-46 using two 68 Ge/ 68 Ga iThemba generators connected in series, of which the older generator is replaced with a new one every 6 months. This configuration enabled elution of maximum activity of 3750 MBq and minimum activity of 2345 MBq, exceeding the elution activity achieved with a single generator by 2300 and 901 MBq respectively. The corrected yield of the labelled products was 91 ± 5% (72 ± 5% non-decay corrected). The additional activity of the labeled products obtained through the two generator configuration enables the examination of 2–4 additional patients per batch and thus resulting in significant cost savings. The direct addition of ascorbic acid to the reaction medium was essential, as it suppressed radiolysis and minimized the impact of metallic impurities. This innovation enabled reproducible labeling without pre-purification, which has not previously been demonstrated with SnO 2 -based generators. Conclusions: Dual-generator elution on the EasyOne module without modification of Trasis single-use cassettes provides a robust and scalable approach for high-yield production of 68 Ga radiopharmaceuticals. The integration of series-connected iThemba generators with in-situ radiolysis control by ascorbic acid ensures consistent GMP-compliant synthesis of [ 68 Ga]Ga-DOTATATE, [ 68 Ga]Ga-Pentixafor, and [ 68 Ga]Ga-FAPI-46. This method improves production efficiency, reduces costs, and expands clinical accessibility.
- 17 February 2026
- Published by Springer Nature in EJNMMI Radiopharmacy and Chemistry
- Vol. 11 (1)
Open AccessIncreasing the activity output and optimization of automated radiosynthesis [68Ga]Ga-DOTATATE, [68Ga]Ga-Pentixafor, and [68Ga]Ga-FAPI-64 using two [68Ge]Ge/[68Ga]Ga iThemba generators in series
Background: The rapidly increasing clinical demand for 68 Ga-labelled radiopharmaceuticals continues to challenge current production capacities, particularly in high-throughput nuclear medicine departments. Although dual-generator concepts have previously been explored, all reported approaches to date have required either pre-purification, fractionated elution, or additional cartridge-based concentration steps, which add complexity and limit routine clinical implementation. In the present study, we report for the first time a fully automated, GMP-compliant synthesis protocol using two iThemba 68 Ge/ 68 Ga generators connected in series on a standard EasyOne module applicable to three clinically relevant tracers. We successfully established robust GMP production of [ 68 Ga]Ga-DOTATATE, [ 68 Ga]Ga-FAPI-46, and [ 68 Ga]Ga-PentixaFor without any pre-purification or fractional elution. A key mechanistic finding of this work is the critical role of direct ascorbic acid addition to the reaction medium, which effectively suppresses radiolysis and metal-ion interference under high-activity conditions. Results: We established a Good Manufacturing Practice (GMP)-compliant, fully automated synthesis of [ 68 Ga]Ga-DOTATATE, [ 68 Ga]Ga-Pentixafor, and [ 68 Ga]Ga-FAPI-46 using two 68 Ge/ 68 Ga iThemba generators connected in series, of which the older generator is replaced with a new one every 6 months. This configuration enabled elution of maximum activity of 3750 MBq and minimum activity of 2345 MBq, exceeding the elution activity achieved with a single generator by 2300 and 901 MBq respectively. The corrected yield of the labelled products was 91 ± 5% (72 ± 5% non-decay corrected). The additional activity of the labeled products obtained through the two generator configuration enables the examination of 2–4 additional patients per batch and thus resulting in significant cost savings. The direct addition of ascorbic acid to the reaction medium was essential, as it suppressed radiolysis and minimized the impact of metallic impurities. This innovation enabled reproducible labeling without pre-purification, which has not previously been demonstrated with SnO 2 -based generators. Conclusions: Dual-generator elution on the EasyOne module without modification of Trasis single-use cassettes provides a robust and scalable approach for high-yield production of 68 Ga radiopharmaceuticals. The integration of series-connected iThemba generators with in-situ radiolysis control by ascorbic acid ensures consistent GMP-compliant synthesis of [ 68 Ga]Ga-DOTATATE, [ 68 Ga]Ga-Pentixafor, and [ 68 Ga]Ga-FAPI-46. This method improves production efficiency, reduces costs, and expands clinical accessibility.
- Open Access
- 29 July 2022
- Published by Springer Nature in EJNMMI Radiopharmacy and Chemistry
- Vol. 7 (1) , 1-16
Automated synthesis of [68Ga]Ga-FAPI-46 without pre-purification of the generator eluate on three common synthesis modules and two generator types
Background: The recent development of quinoline-based radiotracers, which act as fibroblast activation protein inhibitors (FAPIs), has shown promising preclinical and clinical advantages. [68Ga]Ga-FAPI-46 is a new radiotracer for in vivo detection of the fibroblast activation protein by positron emission tomography (PET). Recently, the automated synthesis of [68Ga]Ga-FAPI-46 was reported based on pre-concentration and purification of the generator eluate by using a cation exchange-cartridge. Our aim was to simplify the synthesis and shorten the automated synthesis of [68Ga]Ga-FAPI-46 to make it accessible and thus even more attractive to a broader clinical and scientific community. Results: We developed and evaluated the GMP compliant automatic synthesis of [68Ga]Ga-FAPI-46 using two different 68Ge/68Ga generators (an Eckert & Ziegler, GalliaPharm generator, 1.85 GBq/50 mCi and an iThemba generator, 1.85 GBq/50 mCi) Somerset West, South Africa) and three different commercial and customized systems: the EasyOne module from Trasis; the GaSy module from Synthra with a customized synthesis template and a customized single use cassette. Additionally, the automatic synthesis of [68Ga]Ga-FAPI-46 was established on a GallElut synthesis module from Scintomics with fixed tubing. Conclusions: Independent of the synthesis modules or the generators employed we were able to complete the synthesis of [68Ga]Ga-FAPI-46 in 12 min including the process of purification and formulation. In all cases, the final products showed more than 99.5% chemical purity and the radiochemical yield reached around 92.5% (decay corrected). All quality control parameters (e.g. sterility, stability and radiochemical purity) were conform to the European Pharmacopoeia.
- 29 July 2022
- Published by Springer Nature in EJNMMI Radiopharmacy and Chemistry
- Vol. 7 (1) , 1-16
Open AccessAutomated synthesis of [68Ga]Ga-FAPI-46 without pre-purification of the generator eluate on three common synthesis modules and two generator types
Background: The recent development of quinoline-based radiotracers, which act as fibroblast activation protein inhibitors (FAPIs), has shown promising preclinical and clinical advantages. [68Ga]Ga-FAPI-46 is a new radiotracer for in vivo detection of the fibroblast activation protein by positron emission tomography (PET). Recently, the automated synthesis of [68Ga]Ga-FAPI-46 was reported based on pre-concentration and purification of the generator eluate by using a cation exchange-cartridge. Our aim was to simplify the synthesis and shorten the automated synthesis of [68Ga]Ga-FAPI-46 to make it accessible and thus even more attractive to a broader clinical and scientific community. Results: We developed and evaluated the GMP compliant automatic synthesis of [68Ga]Ga-FAPI-46 using two different 68Ge/68Ga generators (an Eckert & Ziegler, GalliaPharm generator, 1.85 GBq/50 mCi and an iThemba generator, 1.85 GBq/50 mCi) Somerset West, South Africa) and three different commercial and customized systems: the EasyOne module from Trasis; the GaSy module from Synthra with a customized synthesis template and a customized single use cassette. Additionally, the automatic synthesis of [68Ga]Ga-FAPI-46 was established on a GallElut synthesis module from Scintomics with fixed tubing. Conclusions: Independent of the synthesis modules or the generators employed we were able to complete the synthesis of [68Ga]Ga-FAPI-46 in 12 min including the process of purification and formulation. In all cases, the final products showed more than 99.5% chemical purity and the radiochemical yield reached around 92.5% (decay corrected). All quality control parameters (e.g. sterility, stability and radiochemical purity) were conform to the European Pharmacopoeia.
- Open Access
- 17 March 2022
- Published by Elsevier in Physica Medica
- Vol. 96, 157-165
A simple, reliable and accurate approach for assessing [131I]-capsule activity leading to significant reduction of radiation exposure of medical staff during radioiodine therapy
- 17 March 2022
- Published by Elsevier in Physica Medica
- Vol. 96, 157-165
Open AccessA simple, reliable and accurate approach for assessing [131I]-capsule activity leading to significant reduction of radiation exposure of medical staff during radioiodine therapy