Rasmus Nielsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rasmus Nielsen has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Kristian Næser
Randers Regional Hospital, Randers, Denmark
2 shared publications - Anders Fasth
Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg 9 Department of Pediatrics Gothenburg
1 shared publication Anders Ivarsen
Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark
1 shared publicationChristian Hedegaard
Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark
1 shared publicationChristina Møller
Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark
1 shared publicationEllen D. Arnstad
Department of Pediatrics, Levanger Hospital, Nord-Trøndelag Hospital Trust, Levanger, Norway; Department of Clinical and Molecular Medicine, NTNU - Norwegian University of Science and Technology, Trondheim, Norway
1 shared publication
Latest Publications
- 1 November 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (11) , 1039-1040
Reply: Accuracy of thick and thin intraocular lens power formulas using paraxial vergence calculation
- 1 November 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (11) , 1039-1040
Reply: Accuracy of thick and thin intraocular lens power formulas using paraxial vergence calculation
- 1 March 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (3) , 182-187
Accuracy of thick and thin intraocular lens power formulas using paraxial vergence calculation
Purpose: To compare the prediction errors (PEs) of several thick intraocular lens (IOL) formulas with a thin lens approach using variations of the same paraxial vergence calculation formula. Setting: Department of Ophthalmology, Randers Regional Hospital, Denmark. Design: Prospective, noninterventional study. Methods: Optical low coherence reflectometry biometry was prospectively and consecutively performed in 132 eyes with subsequent phacoemulsification and insertion of the same aspheric IOL model. Clinical refraction was performed 2 months postoperatively. Retrospectively, the same paraxial vergence formula was used and only the methods were varied for calculating the postoperative IOL position, thickness, and curvatures to construct 4 formulas: Næser I formula based on thick lens calculation using the manufacturer's cutting card information, Næser II formula based on thick lens calculation using calculated IOL data from open sources, Næser III formula based on thick lens calculation and a fixed IOL thickness of 0.62 mm, and Næser IV formula based on thin lens calculation with fixed IOL position 0.31 mm anterior to the postoperative capsule. Each formula was optimized separately, hereby assuring a mean error of zero. The PE was defined as the difference between the measured and predicted spherical equivalent refraction. Results: Mean absolute error amounted to 0.30 ± 0.26 diopters for all 4 formulas with no statistically significant difference. PE averaged zero for short, normal, and long eyes. Conclusions: The additional optical information provided by thick IOL calculations seems insignificant compared with other sources of error, related to the accuracy of IOL manufacturing, crystalline lens refractive index, and postoperative refraction.
- 1 March 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (3) , 182-187
Accuracy of thick and thin intraocular lens power formulas using paraxial vergence calculation
Purpose: To compare the prediction errors (PEs) of several thick intraocular lens (IOL) formulas with a thin lens approach using variations of the same paraxial vergence calculation formula. Setting: Department of Ophthalmology, Randers Regional Hospital, Denmark. Design: Prospective, noninterventional study. Methods: Optical low coherence reflectometry biometry was prospectively and consecutively performed in 132 eyes with subsequent phacoemulsification and insertion of the same aspheric IOL model. Clinical refraction was performed 2 months postoperatively. Retrospectively, the same paraxial vergence formula was used and only the methods were varied for calculating the postoperative IOL position, thickness, and curvatures to construct 4 formulas: Næser I formula based on thick lens calculation using the manufacturer's cutting card information, Næser II formula based on thick lens calculation using calculated IOL data from open sources, Næser III formula based on thick lens calculation and a fixed IOL thickness of 0.62 mm, and Næser IV formula based on thin lens calculation with fixed IOL position 0.31 mm anterior to the postoperative capsule. Each formula was optimized separately, hereby assuring a mean error of zero. The PE was defined as the difference between the measured and predicted spherical equivalent refraction. Results: Mean absolute error amounted to 0.30 ± 0.26 diopters for all 4 formulas with no statistically significant difference. PE averaged zero for short, normal, and long eyes. Conclusions: The additional optical information provided by thick IOL calculations seems insignificant compared with other sources of error, related to the accuracy of IOL manufacturing, crystalline lens refractive index, and postoperative refraction.
- Open Access
- 1 April 2021
- Published by Elsevier in Ophthalmology
- Vol. 128 (4) , 598-608
Uveitis in Juvenile Idiopathic Arthritis
- 1 April 2021
- Published by Elsevier in Ophthalmology
- Vol. 128 (4) , 598-608
Open AccessUveitis in Juvenile Idiopathic Arthritis
- 11 June 2019
- Published by Wiley in Acta Ophthalmologica
- Vol. 98 (1) , E130-E131
Reproducibility of subjective refraction before and after small incision lenticule extraction (SMILE) for myopia
- 11 June 2019
- Published by Wiley in Acta Ophthalmologica
- Vol. 98 (1) , E130-E131
Reproducibility of subjective refraction before and after small incision lenticule extraction (SMILE) for myopia