Danny Bottenus
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Danny Bottenus has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Johnny Saavedra Lopez
Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)
3 shared publications Marsobyn Salalila
3 shared publicationsTyler Schlieder
3 shared publications- Amanda M. Lines
Pacific Northwest National Laboratory
2 shared publications James Ely
Nuclear, Chemistry & Biology division, National Security directorate, Pacific Northwest National Laboratory Richland Washington USA
2 shared publicationsJason Serkowski
2 shared publications
Latest Publications
- Open Access
- 21 October 2026
- Published by Elsevier in SSRN Electronic Journal
High-Efficiency Chlorine Isotope Separation using Microchannel Distillation
Molten chloride fast reactors require chlorine enriched in ³⁷Cl to reduce neutron capture losses and avoid the formation of corrosive and long-lived radioactive byproducts associated with ³⁵Cl. However, the small mass difference between chlorine isotopes makes industrial-scale enrichment challenging with current separation technologies. Here, we investigate distillation of hydrogen chloride as a near-term separation method, drawing on microchannel distillation concepts to achieve a large vapor-liquid interfacial area and low mass-transfer resistance in a compact column. We designed and tested a 2 m tall batch distillation column and characterized its height equivalent to a theoretical plate (HETP) for two packing media. An alumina foam packing achieved up to 264 separation stages and an HETP of 0.76 cm, while a nickel superalloy honeycomb packing achieved 240 stages and an HETP of 0.84 cm. Extrapolating from the alumina column, we project that reaching enrichment levels suitable for reactor applications would require a 64 m column for 90% ³⁷Cl and 108 m for 99%, at an energy cost of 5 kWh per gram of ³⁷Cl product. Our results demonstrate that microchannel distillation offers a viable route to enriching chlorine isotopes for near-term reactor deployment.
- 21 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessHigh-Efficiency Chlorine Isotope Separation using Microchannel Distillation
Molten chloride fast reactors require chlorine enriched in ³⁷Cl to reduce neutron capture losses and avoid the formation of corrosive and long-lived radioactive byproducts associated with ³⁵Cl. However, the small mass difference between chlorine isotopes makes industrial-scale enrichment challenging with current separation technologies. Here, we investigate distillation of hydrogen chloride as a near-term separation method, drawing on microchannel distillation concepts to achieve a large vapor-liquid interfacial area and low mass-transfer resistance in a compact column. We designed and tested a 2 m tall batch distillation column and characterized its height equivalent to a theoretical plate (HETP) for two packing media. An alumina foam packing achieved up to 264 separation stages and an HETP of 0.76 cm, while a nickel superalloy honeycomb packing achieved 240 stages and an HETP of 0.84 cm. Extrapolating from the alumina column, we project that reaching enrichment levels suitable for reactor applications would require a 64 m column for 90% ³⁷Cl and 108 m for 99%, at an energy cost of 5 kWh per gram of ³⁷Cl product. Our results demonstrate that microchannel distillation offers a viable route to enriching chlorine isotopes for near-term reactor deployment.
- Open Access
- 13 August 2026
- Published by Office of Scientific and Technical Information (OSTI)
Novel Method for Domestic Stable Isotope Production (CRADA #667) Final Report
This report presents the progress achieved on our chlorine isotope separation efforts in the CRADA #667 agreement. We used a microchannel distillation (MCD) packing structure to enrich HCl isotopes (H35Cl, H37Cl) and an isotachophoresis (ITP) separation to enrich ionic chloride species (35Cl- and 37Cl-). A 2 m tall MCD column was constructed and achieved 264 separation stages over several days, which is well above the goal of 50 stages outlined in the CRADA. The resulting height equivalent to a theoretical plate (HETP) was 0.76 cm. ITP tests were run ~ 24 hours and achieved a single-stage separation factor of 1.559.
- 13 August 2026
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessNovel Method for Domestic Stable Isotope Production (CRADA #667) Final Report
This report presents the progress achieved on our chlorine isotope separation efforts in the CRADA #667 agreement. We used a microchannel distillation (MCD) packing structure to enrich HCl isotopes (H35Cl, H37Cl) and an isotachophoresis (ITP) separation to enrich ionic chloride species (35Cl- and 37Cl-). A 2 m tall MCD column was constructed and achieved 264 separation stages over several days, which is well above the goal of 50 stages outlined in the CRADA. The resulting height equivalent to a theoretical plate (HETP) was 0.76 cm. ITP tests were run ~ 24 hours and achieved a single-stage separation factor of 1.559.
- Open Access
- 16 January 2026
- Published by Office of Scientific and Technical Information (OSTI)
Novel Method for Domestic Stable Isotope Production
This report presents the progress achieved on our chlorine isotope separation efforts in the CRADA #667 agreement. We used a microchannel distillation (MCD) packing structure to enrich HCl isotopes (H35Cl, H37Cl) and an isotachophoresis (ITP) separation to enrich ionic chloride species (35Cl- and 37Cl-). A 2 m tall MCD column was constructed and achieved 264 separation stages over several days, which is well above the goal of 50 stages outlined in the CRADA. The resulting height equivalent to a theoretical plate (HETP) was 0.76 cm. ITP tests were run ~ 24 hours and achieved a single-stage separation factor of 1.559.
- 16 January 2026
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessNovel Method for Domestic Stable Isotope Production
This report presents the progress achieved on our chlorine isotope separation efforts in the CRADA #667 agreement. We used a microchannel distillation (MCD) packing structure to enrich HCl isotopes (H35Cl, H37Cl) and an isotachophoresis (ITP) separation to enrich ionic chloride species (35Cl- and 37Cl-). A 2 m tall MCD column was constructed and achieved 264 separation stages over several days, which is well above the goal of 50 stages outlined in the CRADA. The resulting height equivalent to a theoretical plate (HETP) was 0.76 cm. ITP tests were run ~ 24 hours and achieved a single-stage separation factor of 1.559.
- Open Access
- 26 July 2022
- Published by Wiley in Journal of Advanced Manufacturing and Processing
- Vol. 5 (1) , 42-46
Additively manufactured cryogenic microchannel distillation device for air separation
The efficiency of air separation is tested using three different small‐scale cryogenic distillation columns. The performance of a random packed column is compared to the performance of two microchannel distillation (MCD) columns that use thin wicking structures and gas flow channels to achieve process intensification. The MCD columns tested include a plate‐type layered column and an additively manufactured porous honeycomb (AMPH) column. For columns with 25.4 cm of active height and run under similar conditions, the packed, plate‐type layering, and AMPH columns achieved approximate height equivalent of a theoretical plate (HETP) values of 5.5, 3.7, and 3.2 cm for nitrogen, and 5.9, 4.9, and 3.3 cm for argon. The AMPH column can produce up to 0.4 SLM of more than 90% purity oxygen with 12 W of cooling lift. These results demonstrate the feasibility of using additive manufacturing to construct MCD devices and pave a way for constructing novel MCD designs.
- 26 July 2022
- Published by Wiley in Journal of Advanced Manufacturing and Processing
- Vol. 5 (1) , 42-46
Open AccessAdditively manufactured cryogenic microchannel distillation device for air separation
The efficiency of air separation is tested using three different small‐scale cryogenic distillation columns. The performance of a random packed column is compared to the performance of two microchannel distillation (MCD) columns that use thin wicking structures and gas flow channels to achieve process intensification. The MCD columns tested include a plate‐type layered column and an additively manufactured porous honeycomb (AMPH) column. For columns with 25.4 cm of active height and run under similar conditions, the packed, plate‐type layering, and AMPH columns achieved approximate height equivalent of a theoretical plate (HETP) values of 5.5, 3.7, and 3.2 cm for nitrogen, and 5.9, 4.9, and 3.3 cm for argon. The AMPH column can produce up to 0.4 SLM of more than 90% purity oxygen with 12 W of cooling lift. These results demonstrate the feasibility of using additive manufacturing to construct MCD devices and pave a way for constructing novel MCD designs.
- Open Access
- 31 March 2022
- Published by Wiley
Additively Manufactured Cryogenic Microchannel Distillation Device for Air Separation
The efficiency of air separation is tested using three different small scale cryogenic distillation columns. The performance of a random packed column is compared to the performance of two microchannel distillation (MCD) columns that use thin wicking structures and gas flow channels to achieve process intensification. The MCD columns tested include a plate-type layered (PTL) column and an additively manufactured porous honeycomb (AMPH) column. For columns with 25.4 cm of active height and run under similar conditions, the packed, PTL, and AMPH columns achieved approximate height equivalent of a theoretical plate (HETP) values of 5.5, 3.7, and 3.2 cm for nitrogen, and 5.9, 4.9, and 3.3 cm for argon. The AMPH column can produce up to 0.4 SLM of 90+% purity oxygen with 12 W of cooling lift. These results demonstrate the feasibility of using additive manufacturing to construct MCD devices and pave a way for constructing novel MCD designs.
- 31 March 2022
- Published by Wiley
Open AccessAdditively Manufactured Cryogenic Microchannel Distillation Device for Air Separation
The efficiency of air separation is tested using three different small scale cryogenic distillation columns. The performance of a random packed column is compared to the performance of two microchannel distillation (MCD) columns that use thin wicking structures and gas flow channels to achieve process intensification. The MCD columns tested include a plate-type layered (PTL) column and an additively manufactured porous honeycomb (AMPH) column. For columns with 25.4 cm of active height and run under similar conditions, the packed, PTL, and AMPH columns achieved approximate height equivalent of a theoretical plate (HETP) values of 5.5, 3.7, and 3.2 cm for nitrogen, and 5.9, 4.9, and 3.3 cm for argon. The AMPH column can produce up to 0.4 SLM of 90+% purity oxygen with 12 W of cooling lift. These results demonstrate the feasibility of using additive manufacturing to construct MCD devices and pave a way for constructing novel MCD designs.
- 1 November 2020
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1137, 11-18
A versatile and low-cost chip-to-world interface: Enabling ICP-MS characterization of isotachophoretically separated lanthanides on a microfluidic device
- 1 November 2020
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1137, 11-18
A versatile and low-cost chip-to-world interface: Enabling ICP-MS characterization of isotachophoretically separated lanthanides on a microfluidic device
- 17 June 2019
- Published by Wiley in Electrophoresis
- Vol. 40 (18-19) , 2531-2540
Design and optimization of a fused‐silica microfluidic device for separation of trivalent lanthanides by isotachophoresis
Elemental analysis of rare earth elements is essential in a variety of fields including environmental monitoring and nuclear safeguards; however, current techniques are often labor intensive, time consuming, and/or costly to perform. The difficulty arises in preparing samples, which requires separating the chemically and physically similar lanthanides. However, by transitioning these separations to the microscale, the speed, cost, and simplicity of sample preparation can be drastically improved. Here, all fourteen non‐radioactive lanthanides (lanthanum through lutetium minus promethium) are separated by ITP for the first time in a serpentine fused‐silica microchannel (70 µm wide × 70 µm tall × 33 cm long) in 4D) to calculate ITP zone lengths in combination with ITP theory. Optimization of experimental procedures and reproducibility based on statistical analysis of subsequent experimental results are addressed. Percent error values in band length and conductivity are ≤8.1 and 0.37%, respectively.
- 17 June 2019
- Published by Wiley in Electrophoresis
- Vol. 40 (18-19) , 2531-2540
Design and optimization of a fused‐silica microfluidic device for separation of trivalent lanthanides by isotachophoresis
Elemental analysis of rare earth elements is essential in a variety of fields including environmental monitoring and nuclear safeguards; however, current techniques are often labor intensive, time consuming, and/or costly to perform. The difficulty arises in preparing samples, which requires separating the chemically and physically similar lanthanides. However, by transitioning these separations to the microscale, the speed, cost, and simplicity of sample preparation can be drastically improved. Here, all fourteen non‐radioactive lanthanides (lanthanum through lutetium minus promethium) are separated by ITP for the first time in a serpentine fused‐silica microchannel (70 µm wide × 70 µm tall × 33 cm long) in 4D) to calculate ITP zone lengths in combination with ITP theory. Optimization of experimental procedures and reproducibility based on statistical analysis of subsequent experimental results are addressed. Percent error values in band length and conductivity are ≤8.1 and 0.37%, respectively.