Jeoh Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jeoh Han has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Do Haeng Hur
Materials Safety Technology Development Division, Korea Atomic Energy Research Institute, Daejeon 34057, Republic of Korea
9 shared publications - Soon-Hyeok Jeon
Materials Safety Technology Development Division, Korea Atomic Energy Research Institute, Daejeon 34057, Republic of Korea
4 shared publications - Geun Dong Song
Korea Atomic Energy Research Institute, 989-111 Deadeok-daero, Yuseong-gu, Daejeon 34057, Korea
3 shared publications - Young-Kook Lee
Department of Materials Science and Engineering, Yonsei University, Seoul, Republic of Korea
2 shared publications - Byung-Joon Bae
Materials Safety Technology Development Division, Korea Atomic Energy Research Institute, Daejeon 34057, Korea
1 shared publication - Hee-Sang Shim
Materials Safety Technology Development Division, Korea Atomic Energy Research Institute, Daejeon 34057, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 28 July 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (12)
Characteristics of eddy current signals with magnetite-induced flow path blockage in trefoil-type tube support plates of steam generators
- 28 July 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (12)
Open AccessCharacteristics of eddy current signals with magnetite-induced flow path blockage in trefoil-type tube support plates of steam generators
- Open Access
Atomic-Scale Insights into Flow-Accelerated Corrosion of Carbon Steel
The role of flow velocity on the formation and dissolution of oxides on SA106Gr.B carbon steel was investigated at both microscopic and atomic scales. In static water, a compact oxide layer with highly faceted magnetite particles was formed. Atomic-scale transmission electron microscopy images of such a layer revealed highly ordered and parallel lattice fringes, indicating that the oxide had very high crystallinity and minimal lattice defects. In contrast, turbulent water prompted the creation of a porous oxide layer consisting of amorphous magnetite particles. Here, numerous mismatched lattice fringes were observed, indicating a prevalence of point defects within the oxide structure. These differences in oxide properties are attributed to hydrodynamic shear stress induced by turbulent flow. These findings provide atomic-level insights into how carbon steel corrosion accelerates in fast-flowing water.
Open AccessAtomic-Scale Insights into Flow-Accelerated Corrosion of Carbon Steel
The role of flow velocity on the formation and dissolution of oxides on SA106Gr.B carbon steel was investigated at both microscopic and atomic scales. In static water, a compact oxide layer with highly faceted magnetite particles was formed. Atomic-scale transmission electron microscopy images of such a layer revealed highly ordered and parallel lattice fringes, indicating that the oxide had very high crystallinity and minimal lattice defects. In contrast, turbulent water prompted the creation of a porous oxide layer consisting of amorphous magnetite particles. Here, numerous mismatched lattice fringes were observed, indicating a prevalence of point defects within the oxide structure. These differences in oxide properties are attributed to hydrodynamic shear stress induced by turbulent flow. These findings provide atomic-level insights into how carbon steel corrosion accelerates in fast-flowing water.
- Open Access
On the Use of NaOH Solution to Simulate the Crevice Conditions of a Nuclear Steam Generator
The corrosion behavior and integrity of steam generator (SG) tube materials have frequently been tested in solutions containing sodium hydroxide (NaOH), assuming that NaOH is a typical contaminant concentrated in the crevices of SGs in a pressurized water reactor. The purpose of this study was to investigate the adequacy of using concentrated NaOH solutions to simulate the crevice environments of SGs. The dissolution behavior of magnetite deposit flakes formed in an operating SG was tested in a 0.4 wt.% NaOH solution at 300 °C, and the thermodynamic stability of magnetite was investigated using the potential-pH diagram for an iron–water system. The magnetite deposits were rapidly dissolved in the test solution, which was supported by the fact that magnetite is thermodynamically unstable under the test condition to dissolve to dihypoferrite ions (HFeO2−). These results indicate that research data obtained from concentrated NaOH solutions are not appropriate to apply to the crevice environments of SGs.
Open AccessOn the Use of NaOH Solution to Simulate the Crevice Conditions of a Nuclear Steam Generator
The corrosion behavior and integrity of steam generator (SG) tube materials have frequently been tested in solutions containing sodium hydroxide (NaOH), assuming that NaOH is a typical contaminant concentrated in the crevices of SGs in a pressurized water reactor. The purpose of this study was to investigate the adequacy of using concentrated NaOH solutions to simulate the crevice environments of SGs. The dissolution behavior of magnetite deposit flakes formed in an operating SG was tested in a 0.4 wt.% NaOH solution at 300 °C, and the thermodynamic stability of magnetite was investigated using the potential-pH diagram for an iron–water system. The magnetite deposits were rapidly dissolved in the test solution, which was supported by the fact that magnetite is thermodynamically unstable under the test condition to dissolve to dihypoferrite ions (HFeO2−). These results indicate that research data obtained from concentrated NaOH solutions are not appropriate to apply to the crevice environments of SGs.
- Open Access
- 1 November 2022
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 21, 3051-3061
Effect of gadolinium addition on the corrosion behavior and oxide properties of titanium in boric acid solution at 50 °C
- 1 November 2022
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 21, 3051-3061
Open AccessEffect of gadolinium addition on the corrosion behavior and oxide properties of titanium in boric acid solution at 50 °C
- Open Access
Chemical Cleaning of Magnetite Deposits on the Flow Mini-Channels of a Printed Circuit Heat Exchanger in an EDTA-Based Solution
The dissolution behavior of magnetite deposited on flow mini-channel surfaces within a printed circuit heat exchanger (PCHE) and the corrosion behavior of a STS 316L PCHE material were investigated in an ethylendiaminetetraacetic acid (EDTA)-based chemical cleaning solution at 93 °C. The fouling in the PCHE was simulated using a water-steam circulation loop system. Most of the magnetite deposits were rapidly dissolved in the early stage of the circulation chemical cleaning. An empirical equation for estimating the dissolution percentage was derived as a function of cleaning time. The PCHE material showed excellent corrosion resistance during the chemical cleaning tests. These results indicate the fouling layers in the PCHEs can be removed efficiently by the chemical cleaning process without concern about base metal corrosion.
Open AccessChemical Cleaning of Magnetite Deposits on the Flow Mini-Channels of a Printed Circuit Heat Exchanger in an EDTA-Based Solution
The dissolution behavior of magnetite deposited on flow mini-channel surfaces within a printed circuit heat exchanger (PCHE) and the corrosion behavior of a STS 316L PCHE material were investigated in an ethylendiaminetetraacetic acid (EDTA)-based chemical cleaning solution at 93 °C. The fouling in the PCHE was simulated using a water-steam circulation loop system. Most of the magnetite deposits were rapidly dissolved in the early stage of the circulation chemical cleaning. An empirical equation for estimating the dissolution percentage was derived as a function of cleaning time. The PCHE material showed excellent corrosion resistance during the chemical cleaning tests. These results indicate the fouling layers in the PCHEs can be removed efficiently by the chemical cleaning process without concern about base metal corrosion.
- Open Access
Effect of Tensile Stress on the Oxide Properties of a Nickel-Based Alloy 600 in Simulated PWR Secondary Water
The purpose of this work was to examine the effect of tensile stress on the oxide properties of a nickel-based Alloy 600 that was exposed to simulated nuclear steam generator water at 340 °C for 1000 h. The size of the outer oxide particles increased, and the chromium content of the inner oxides decreased under tensile stress. Electrochemical measurements revealed that the charge carrier density increased, and the charge transfer resistance and film resistance were reduced under the tensile stress condition. These changes in the oxide properties are attributed to the formation of short diffusion paths such as line and surface defects due to tensile deformation.
Open AccessEffect of Tensile Stress on the Oxide Properties of a Nickel-Based Alloy 600 in Simulated PWR Secondary Water
The purpose of this work was to examine the effect of tensile stress on the oxide properties of a nickel-based Alloy 600 that was exposed to simulated nuclear steam generator water at 340 °C for 1000 h. The size of the outer oxide particles increased, and the chromium content of the inner oxides decreased under tensile stress. Electrochemical measurements revealed that the charge carrier density increased, and the charge transfer resistance and film resistance were reduced under the tensile stress condition. These changes in the oxide properties are attributed to the formation of short diffusion paths such as line and surface defects due to tensile deformation.
- Open Access
Simulation of Porous Magnetite Deposits on Steam Generator Tubes in Circulating Water at 270 °C
In the secondary side of pressurized water reactors (PWRs), the main corrosion product accumulated on the steam generator (SG) tubes is magnetite, which has a porous structure. The purpose of this work is to simulate the porous magnetite deposited to the SG tubes using a loop system. We newly developed a circulating loop system for a porous magnetite deposition test. A test section was designed as a single hydraulic flow channel, and a cartridge heater was fabricated and mounted into a commercial SG tube to provide an equal heating source for the primary water. After the deposition test, the simulated magnetite deposits were characterized for comparison to real SG tube deposits collected from an operating PWR plant. The magnetite deposits produced using the loop system were appropriate for simulating the real SG tube deposits because the particle characteristics, phase, and porous morphology are closely similar to those of real deposit samples. Using the loop system, the chemical impurities such as Na and Cl can be easily concentrated within the pores of the simulated magnetite deposits. These simulated magnetite samples are expected to be widely utilized in various research fields such as the heat transfer degradation and magnetite accelerated corrosion of SG tubes.
Open AccessSimulation of Porous Magnetite Deposits on Steam Generator Tubes in Circulating Water at 270 °C
In the secondary side of pressurized water reactors (PWRs), the main corrosion product accumulated on the steam generator (SG) tubes is magnetite, which has a porous structure. The purpose of this work is to simulate the porous magnetite deposited to the SG tubes using a loop system. We newly developed a circulating loop system for a porous magnetite deposition test. A test section was designed as a single hydraulic flow channel, and a cartridge heater was fabricated and mounted into a commercial SG tube to provide an equal heating source for the primary water. After the deposition test, the simulated magnetite deposits were characterized for comparison to real SG tube deposits collected from an operating PWR plant. The magnetite deposits produced using the loop system were appropriate for simulating the real SG tube deposits because the particle characteristics, phase, and porous morphology are closely similar to those of real deposit samples. Using the loop system, the chemical impurities such as Na and Cl can be easily concentrated within the pores of the simulated magnetite deposits. These simulated magnetite samples are expected to be widely utilized in various research fields such as the heat transfer degradation and magnetite accelerated corrosion of SG tubes.
- Open Access
Molar Ratio Effect of Sodium to Chloride Ions on the Electrochemical Corrosion of Alloy 600 and SA508 in HCl + NaOH Mixtures
This study aims to investigate the molar ratio effect of sodium to chloride ions on the corrosion of an Alloy 600 steam generator tube and an SA508 tubesheet material. The corrosion behavior was evaluated in solutions with three different molar ratios of sodium to chloride ions using a potentiodynamic polarization method. The corrosion potentials and corrosion rates of both the two materials were significantly decreased as the molar ratio increased from 0.1 to 10. Therefore, it is recommended that the molar ratio control to a value of 1 is beneficial only when the crevice chemistry has a low molar ratio with an acidic pH. The corrosion potentials and corrosion rates were little affected by the total sodium and chloride ion concentrations. SA508 acted as an anode and its corrosion rate was accelerated by galvanic coupling with Alloy 600.
Open AccessMolar Ratio Effect of Sodium to Chloride Ions on the Electrochemical Corrosion of Alloy 600 and SA508 in HCl + NaOH Mixtures
This study aims to investigate the molar ratio effect of sodium to chloride ions on the corrosion of an Alloy 600 steam generator tube and an SA508 tubesheet material. The corrosion behavior was evaluated in solutions with three different molar ratios of sodium to chloride ions using a potentiodynamic polarization method. The corrosion potentials and corrosion rates of both the two materials were significantly decreased as the molar ratio increased from 0.1 to 10. Therefore, it is recommended that the molar ratio control to a value of 1 is beneficial only when the crevice chemistry has a low molar ratio with an acidic pH. The corrosion potentials and corrosion rates were little affected by the total sodium and chloride ion concentrations. SA508 acted as an anode and its corrosion rate was accelerated by galvanic coupling with Alloy 600.
- Open Access
Magnetite-Accelerated Corrosion of SA508 Tubesheet Material and Its Effect on Steam Generator Tube Denting
The objective of this work is to investigate the magnetite-accelerated corrosion phenomenon of SA508 used as tubesheet material in simulated secondary side environments of pressurized water reactors through immersion and electrochemical tests. The presence of sulfate ions induced the fast growth of a corrosion product layer on SA508, and this phenomenon was accelerated when the SA508 was coupled to magnetite. From the perspective of electrochemical behavior, it was found that SA508 behaves as an anodic member in the coupling system with magnetite, resulting in an increased corrosion rate.
Open AccessMagnetite-Accelerated Corrosion of SA508 Tubesheet Material and Its Effect on Steam Generator Tube Denting
The objective of this work is to investigate the magnetite-accelerated corrosion phenomenon of SA508 used as tubesheet material in simulated secondary side environments of pressurized water reactors through immersion and electrochemical tests. The presence of sulfate ions induced the fast growth of a corrosion product layer on SA508, and this phenomenon was accelerated when the SA508 was coupled to magnetite. From the perspective of electrochemical behavior, it was found that SA508 behaves as an anodic member in the coupling system with magnetite, resulting in an increased corrosion rate.
- Open Access
Stress Corrosion Cracking Behavior of Alloy 600 Coupled to Magnetite under High-Temperature Caustic Conditions
This study aims to investigate and explain the magnetite-accelerated stress corrosion cracking phenomenon of Alloy 600 under caustic conditions, based on the electrochemical behavior. After the SCC test that lasted for 300 h, no cracks were observed in any of the magnetite-free specimens, whereas cracks with a depth of 150 to 280 μm were generated in all the magnetite-deposited specimens. Furthermore, the electrochemical behavior of magnetite and Alloy 600 demonstrated that Alloy 600 behaved as an anode in the coupling system with magnetite. In this coupling system, the electrochemical potential of Alloy 600 can be shifted into the range potentially susceptible to stress corrosion cracking.
Open AccessStress Corrosion Cracking Behavior of Alloy 600 Coupled to Magnetite under High-Temperature Caustic Conditions
This study aims to investigate and explain the magnetite-accelerated stress corrosion cracking phenomenon of Alloy 600 under caustic conditions, based on the electrochemical behavior. After the SCC test that lasted for 300 h, no cracks were observed in any of the magnetite-free specimens, whereas cracks with a depth of 150 to 280 μm were generated in all the magnetite-deposited specimens. Furthermore, the electrochemical behavior of magnetite and Alloy 600 demonstrated that Alloy 600 behaved as an anode in the coupling system with magnetite. In this coupling system, the electrochemical potential of Alloy 600 can be shifted into the range potentially susceptible to stress corrosion cracking.