Loraine Torres-Castro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Loraine Torres-Castro has a total of 122 co-authors. Here are the top co-authors by number of shared publications:
- Alex Martin Bates
Sandia National Laboratories
15 shared publications - John Christopher Hewson
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
8 shared publications Nathan Brenner Johnson
Sandia National Laboratories
8 shared publications- Nathan Brenner Johnson
Sandia National Laboratories
8 shared publications Joshua Lamb
7 shared publicationsAlbuquerque Sandia National Laboratories (Snl-Nm)
6 shared publications
Latest Publications
- 1 October 2026
- Published by Office of Scientific and Technical Information (OSTI)
Room-Scale Lithium-Ion Battery Fires: Suppression Performance, Fire Modeling, and Turnout-Gear Decontamination
Rapid growth of lithium-ion battery (LIB) applications has introduced complex fire dynamics, potential toxic exposures, and decontamination challenges for first responders. This study integrates room-scale fire experiments, contamination analysis, and multi-scale modeling to inform tactics and Personal Protective Equipment (PPE) care. Five 1 kWh pouch-cell battery packs underwent thermal runaway under different experimental conditions including no suppressant, fire blanket, water, and water-addi
- 1 October 2026
- Published by Office of Scientific and Technical Information (OSTI)
Room-Scale Lithium-Ion Battery Fires: Suppression Performance, Fire Modeling, and Turnout-Gear Decontamination
Rapid growth of lithium-ion battery (LIB) applications has introduced complex fire dynamics, potential toxic exposures, and decontamination challenges for first responders. This study integrates room-scale fire experiments, contamination analysis, and multi-scale modeling to inform tactics and Personal Protective Equipment (PPE) care. Five 1 kWh pouch-cell battery packs underwent thermal runaway under different experimental conditions including no suppressant, fire blanket, water, and water-addi
- Open Access
- 17 September 2026
- Published by Elsevier in Journal of Power Sources
- Vol. 696
Microcell-based safety analysis of Si/graphite anodes paired with high-Ni cathodes
- 17 September 2026
- Published by Elsevier in Journal of Power Sources
- Vol. 696
Open AccessMicrocell-based safety analysis of Si/graphite anodes paired with high-Ni cathodes
- 7 July 2026
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2026-01 (1) , 123
(Invited) Exposing the Flammability of Solid-State Batteries: Thermite Reactions in Action
Lithium-metal all-solid-state batteries (LiSSBs) have emerged as a promising solution for meeting the energy-density and safety requirements of advanced technologies, particularly electric vehicles (EVs). Because they contain no liquid electrolytes, these batteries were long believed to be inherently safer and non-flammable. However, recent findings challenge this assumption, showing that even solid electrolytes can ignite in the presence of lithium metal. Surprisingly, one critical aspect has been largely overlooked: the potential for a thermite-type reaction between the Li-metal anode and the cathode.
- 7 July 2026
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2026-01 (1) , 123
(Invited) Exposing the Flammability of Solid-State Batteries: Thermite Reactions in Action
Lithium-metal all-solid-state batteries (LiSSBs) have emerged as a promising solution for meeting the energy-density and safety requirements of advanced technologies, particularly electric vehicles (EVs). Because they contain no liquid electrolytes, these batteries were long believed to be inherently safer and non-flammable. However, recent findings challenge this assumption, showing that even solid electrolytes can ignite in the presence of lithium metal. Surprisingly, one critical aspect has been largely overlooked: the potential for a thermite-type reaction between the Li-metal anode and the cathode.
- 7 July 2026
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2026-01 (1) , 122
Electric Vehicle Battery Vent Gas Analysis and Plume Study
As the adoption of lithium-ion (Li-ion) batteries in electric vehicles (EVs) continues to rise, understanding the potential hazards associated with catastrophic events such as battery fires initiated by thermal runaway (TR) that could occur in enclosed environments is crucial for enhancing safety protocols, particularly for first responders.
- 7 July 2026
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2026-01 (1) , 122
Electric Vehicle Battery Vent Gas Analysis and Plume Study
As the adoption of lithium-ion (Li-ion) batteries in electric vehicles (EVs) continues to rise, understanding the potential hazards associated with catastrophic events such as battery fires initiated by thermal runaway (TR) that could occur in enclosed environments is crucial for enhancing safety protocols, particularly for first responders.
- 7 July 2026
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2026-01 (1) , 118
Evaluation of Advanced Sensors for Early Thermal Runaway Detection in Scaled Electric Vehicle Packs
Early detection of thermal runaway (TR) in electric vehicle (EV) battery packs is challenging due to system scale. Sparse temperature sensing and voltage-signal averaging across parallel-connected cells make conventional methods slow and unreliable for detecting single-cell failures. In recent years, more advanced sensors have been proposed for early TR detection. These include a variety of gas sensors to detect off-gassing and vent gas emissions preceding TR and rapid electrochemical impedance spectroscopy (EIS) to detect early electrochemical changes within cells [1, 2]. However, experimental validation has largely been focused on cell and small module configurations.
- 7 July 2026
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2026-01 (1) , 118
Evaluation of Advanced Sensors for Early Thermal Runaway Detection in Scaled Electric Vehicle Packs
Early detection of thermal runaway (TR) in electric vehicle (EV) battery packs is challenging due to system scale. Sparse temperature sensing and voltage-signal averaging across parallel-connected cells make conventional methods slow and unreliable for detecting single-cell failures. In recent years, more advanced sensors have been proposed for early TR detection. These include a variety of gas sensors to detect off-gassing and vent gas emissions preceding TR and rapid electrochemical impedance spectroscopy (EIS) to detect early electrochemical changes within cells [1, 2]. However, experimental validation has largely been focused on cell and small module configurations.
- 24 November 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-02 (3) , 365
Early-Stage Thermal Safety Evaluation of NMC811/LLZO/Li Batteries with and without Liquid Electrolyte Using Differential Scanning Calorimetry
The thermal safety of lithium-ion batteries is a major challenge for large-scale applications. Although usually assumed safe, lithium solid-state batteries can still undergo thermal runaway as a result of highly exothermic redox reactions between the lithium metal anode and the oxygen from decomposed cathode oxide active material 1 . The current strategy for battery safety evaluation often applies to the large-format (i.e., at least several Ah) cells 2,3 , which can be costly and less informative to the material-scale research. Therefore, an early-scale material-level thermal safety evaluation is beneficial for the development of new battery chemistry sets. We have developed a methodology of using differential scanning calorimetry (DSC) to evaluate the thermal behaviors of a combined anode-cathode-electrolyte (ACE) sample 4 . The thermal metrics of the ACE sample in the temperature range of 40-500°C can be quantified, including the onset temperatures of exothermic reactions, the heat release rate, and the cumulative heat. A hypothetical reaction pathway is constructed by following mass-energy balances of the ACE samples and the above-mentioned metrics to help understand the complex reactions in the cell at elevated temperatures. In this work, we developed a milligram-scale ACE sample of lithium metal anode, NMC811 cathode, and LLZO solid electrolyte to provide insight on the NMC811 solid state battery. We studied samples both with and without liquid electrolyte. The thermal behavior of the ACE sample was examined with DSC to construct a hypothetical reaction pathway. We found that the total heat reaches 2500-3500 J/g NMC811 in a NMC811/LLZO/Li ACE sample with the onset temperature of the first exothermic peak at ~220°C. We also found that adding liquid electrolytes can cause a higher total heat release (3500-4500 J/g NMC811 ), an earlier onset temperature of 180°C, and more stochastic reaction pathways. Finally, we provide comparisons of the thermal behaviors of the NMC811/LLZO/Li chemistry with and without liquid electrolyte to other chemistries of interest (e.g., related Li-ion chemistries). References: (1) Bates, A.; Preger, Y.; Torres-Castro, L.; Harrison, K.; Harris, S.; Hewson, J. Are Solid-State Batteries Safer than Lithium-Ion Batteries? JOULE 2022 , 6 (4), 742–755. (2) Bates, A.; Torres-Castro, L.; Albertus, P.; Mukherjee, P. P.; Jeevarajan, J.; Johnson, N.; Bhargava, B.; Wang, Z.; Ogundipe, T.; Vishnugopi, B. S.; Karmakar, A.; Tang, W. S. A Multi-Scale Framework for Advancing Battery Safety Through Early Calorimetric Analysis of Materials and Components. The Electrochemical Society Interface 2024 , 33 (3), 69. (3) Yang, S.-J.; Hu, J.-K.; Jiang, F.-N.; Cheng, X.-B.; Sun, S.; Hsu, H.-J.; Ren, D.; Zhao, C.-Z.; Yuan, H.; Ouyang, M.; Fan, L.-Z.; Huang, J.-Q.; Zhang, Q. Oxygen-Induced Thermal Runaway Mechanisms of Ah-Level Solid-State Lithium Metal Pouch Cells. eTransportation 2023 , 18 , 100279. (4) Bhargava, B.; Johnson, N. B.; Bates, A. M.; Torres-Castro, L.; Albertus, P. Methods for Quantitative Thermal Analysis of Lithium Solid-State and Beyond Battery Safety. Journal of The Electrochemical Society 2024 , 171 (11), 110525.
- 24 November 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-02 (3) , 365
Early-Stage Thermal Safety Evaluation of NMC811/LLZO/Li Batteries with and without Liquid Electrolyte Using Differential Scanning Calorimetry
The thermal safety of lithium-ion batteries is a major challenge for large-scale applications. Although usually assumed safe, lithium solid-state batteries can still undergo thermal runaway as a result of highly exothermic redox reactions between the lithium metal anode and the oxygen from decomposed cathode oxide active material 1 . The current strategy for battery safety evaluation often applies to the large-format (i.e., at least several Ah) cells 2,3 , which can be costly and less informative to the material-scale research. Therefore, an early-scale material-level thermal safety evaluation is beneficial for the development of new battery chemistry sets. We have developed a methodology of using differential scanning calorimetry (DSC) to evaluate the thermal behaviors of a combined anode-cathode-electrolyte (ACE) sample 4 . The thermal metrics of the ACE sample in the temperature range of 40-500°C can be quantified, including the onset temperatures of exothermic reactions, the heat release rate, and the cumulative heat. A hypothetical reaction pathway is constructed by following mass-energy balances of the ACE samples and the above-mentioned metrics to help understand the complex reactions in the cell at elevated temperatures. In this work, we developed a milligram-scale ACE sample of lithium metal anode, NMC811 cathode, and LLZO solid electrolyte to provide insight on the NMC811 solid state battery. We studied samples both with and without liquid electrolyte. The thermal behavior of the ACE sample was examined with DSC to construct a hypothetical reaction pathway. We found that the total heat reaches 2500-3500 J/g NMC811 in a NMC811/LLZO/Li ACE sample with the onset temperature of the first exothermic peak at ~220°C. We also found that adding liquid electrolytes can cause a higher total heat release (3500-4500 J/g NMC811 ), an earlier onset temperature of 180°C, and more stochastic reaction pathways. Finally, we provide comparisons of the thermal behaviors of the NMC811/LLZO/Li chemistry with and without liquid electrolyte to other chemistries of interest (e.g., related Li-ion chemistries). References: (1) Bates, A.; Preger, Y.; Torres-Castro, L.; Harrison, K.; Harris, S.; Hewson, J. Are Solid-State Batteries Safer than Lithium-Ion Batteries? JOULE 2022 , 6 (4), 742–755. (2) Bates, A.; Torres-Castro, L.; Albertus, P.; Mukherjee, P. P.; Jeevarajan, J.; Johnson, N.; Bhargava, B.; Wang, Z.; Ogundipe, T.; Vishnugopi, B. S.; Karmakar, A.; Tang, W. S. A Multi-Scale Framework for Advancing Battery Safety Through Early Calorimetric Analysis of Materials and Components. The Electrochemical Society Interface 2024 , 33 (3), 69. (3) Yang, S.-J.; Hu, J.-K.; Jiang, F.-N.; Cheng, X.-B.; Sun, S.; Hsu, H.-J.; Ren, D.; Zhao, C.-Z.; Yuan, H.; Ouyang, M.; Fan, L.-Z.; Huang, J.-Q.; Zhang, Q. Oxygen-Induced Thermal Runaway Mechanisms of Ah-Level Solid-State Lithium Metal Pouch Cells. eTransportation 2023 , 18 , 100279. (4) Bhargava, B.; Johnson, N. B.; Bates, A. M.; Torres-Castro, L.; Albertus, P. Methods for Quantitative Thermal Analysis of Lithium Solid-State and Beyond Battery Safety. Journal of The Electrochemical Society 2024 , 171 (11), 110525.
- Open Access
- 1 August 2025
- Published by Office of Scientific and Technical Information (OSTI)
How Safe Are Solid-State Batteries? Identifying Hazards with a Bottom-Up Approach
- 1 August 2025
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessHow Safe Are Solid-State Batteries? Identifying Hazards with a Bottom-Up Approach
- 11 July 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-01 (5) , 638
Are Solid State Batteries Non-Flammable?
Lithium metal all-Solid-State Batteries (LiSSB) are the focus of extensive research activity in energy storage given their potential to meet the energy and safety requirements of advanced applications such as electric vehicles (EVs). With no liquid electrolyte present, these batteries were considered safer and non-flammable. However, recent studies have demonstrated that even solid electrolytes can ignite in the presence of lithium metal. Until now, very little research has addressed the stability between lithium and active materials. We have identified a concerning area that has been largely overlooked regarding the Li-metal anode: the thermite reaction. Through thermodynamic modelling and experimental validation our study reveals that a thermite reaction occurs between the Li-metal anode and the LFP cathode, generating temperatures up to 2,500°C, high enough to vaporize pure lithium in an inert environment. We anticipate this reaction will also occur with NMC and LNMO cathodes, potentially leading to even higher temperature increases. The thermite reaction triggers spontaneously at 500°C with poor surface contact, while increasing surface contact through mixing initiates the reaction at room temperature in an inert environment. Despite its fast kinetics, this reaction is transport-limited due to lithium passivation, leading to long burn times and reignition risks. Given the risk of lithium metal contacting the cathode during failure, understanding these reactions is crucial for ensuring the safe deployment of LiSSBs.
- 11 July 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-01 (5) , 638
Are Solid State Batteries Non-Flammable?
Lithium metal all-Solid-State Batteries (LiSSB) are the focus of extensive research activity in energy storage given their potential to meet the energy and safety requirements of advanced applications such as electric vehicles (EVs). With no liquid electrolyte present, these batteries were considered safer and non-flammable. However, recent studies have demonstrated that even solid electrolytes can ignite in the presence of lithium metal. Until now, very little research has addressed the stability between lithium and active materials. We have identified a concerning area that has been largely overlooked regarding the Li-metal anode: the thermite reaction. Through thermodynamic modelling and experimental validation our study reveals that a thermite reaction occurs between the Li-metal anode and the LFP cathode, generating temperatures up to 2,500°C, high enough to vaporize pure lithium in an inert environment. We anticipate this reaction will also occur with NMC and LNMO cathodes, potentially leading to even higher temperature increases. The thermite reaction triggers spontaneously at 500°C with poor surface contact, while increasing surface contact through mixing initiates the reaction at room temperature in an inert environment. Despite its fast kinetics, this reaction is transport-limited due to lithium passivation, leading to long burn times and reignition risks. Given the risk of lithium metal contacting the cathode during failure, understanding these reactions is crucial for ensuring the safe deployment of LiSSBs.
- 11 July 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-01 (5) , 567
(Invited) Diagnostics for Early Detection of Thermal Runaway in Electric Vehicle Batteries
Lithium-ion battery (LIB) failures can occur abruptly under a variety of conditions, including during charging, active operation, or even while at rest. Current battery management systems (BMS) are often inadequate in detecting the onset of thermal runaway until failure is imminent, which can leave electric vehicle occupants with insufficient warning times and limited intervention options. This highlights the urgent need for advanced diagnostic methods that can provide early warnings of LIB failures. The abuse of battery cells—stemming from factors such as rapid charging, manufacturing defects, or environmental stresses—can significantly impact the state of stability (SoS) of the cells. SoS is a comprehensive assessment of a cell's health and safety, encompassing potential failure modes and structural integrity throughout the battery's lifecycle. Traditional BMS technology primarily relies on monitoring temperature and voltage as a function of state of charge to establish cell SoS. However, this approach proves inadequate under abusive conditions, as it often fails to detect early degradation markers until catastrophic failure is imminent. The voltage profile of LIBs typically remains uniform until just before failure, making it challenging to identify critical changes in cell condition. Once significant deviations in voltage or temperature are observed, thermal runaway is often unavoidable, with few effective means of suppression or mitigation available. Electrochemical Impedance Spectroscopy (EIS) presents a promising avenue for assessing the SoS of electrochemical cells and battery packs. However, its application has been historically limited by the requirement for a pseudo-linear steady-state system, as dynamic changes in temperature or voltage can introduce noise and distort data. This limitation has constrained EIS to time-consuming full spectral measurements conducted on stationary batteries or single-frequency assessments that yield limited diagnostic insights. To address these challenges, researchers have developed a specialized impedance measurement tool capable of capturing impedance spectra at multiple discrete frequencies within ten to fifteen-second intervals. This rapid collection of EIS data is crucial for accurately establishing failure markers and enabling EIS to function as an onboard diagnostic tool. However, the effectiveness may diminish when transitioning from single cells to multi-cell packs, necessitating the integration of non-electrochemical diagnostics to enhance SoS assessments. Non-electrochemical diagnostics, particularly gas sensing, can provide valuable early warning signals, especially in large battery packs containing hundreds or thousands of cells. During thermal runaway, detectable gases typically include volatile organic compounds from electrolyte solvents, carbon dioxide, and hydrogen. The combination of gas sensing and rapid EIS has the potential to offer early warnings through effective SoS monitoring, thereby preventing catastrophic failures. In this study, we evaluate commercial gas sensors alongside rapid EIS to identify warning times for battery cells subjected to thermal and electrical abuse. The signals obtained from rapid EIS and gas sensing are correlated with live sampling conducted using Fourier Transform Infrared Spectrometry and Mass Spectrometry. This comprehensive gas analysis provides deeper insights into the failure mechanisms of abused cells and establishes a technical foundation for diagnostics that could be employed to monitor the SoS of both individual cells and entire battery packs. Throughout our experiments, we identify specific markers in the EIS and gas sensor data that correspond to the onset of unstable conditions. These markers could be integrated into a BMS or utilized to assess the SoS of batteries with unknown conditions. Identifying diagnostic tools that can pinpoint failure markers with sufficient lead time for intervention is critical for minimizing the consequences of LIB failures and enhancing the overall safety of electric vehicles. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology and Engineering Solutions of Sandia LLC, a wholly owned subsidiary of Honeywell International Inc. for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2024-16692A
- 11 July 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-01 (5) , 567
(Invited) Diagnostics for Early Detection of Thermal Runaway in Electric Vehicle Batteries
Lithium-ion battery (LIB) failures can occur abruptly under a variety of conditions, including during charging, active operation, or even while at rest. Current battery management systems (BMS) are often inadequate in detecting the onset of thermal runaway until failure is imminent, which can leave electric vehicle occupants with insufficient warning times and limited intervention options. This highlights the urgent need for advanced diagnostic methods that can provide early warnings of LIB failures. The abuse of battery cells—stemming from factors such as rapid charging, manufacturing defects, or environmental stresses—can significantly impact the state of stability (SoS) of the cells. SoS is a comprehensive assessment of a cell's health and safety, encompassing potential failure modes and structural integrity throughout the battery's lifecycle. Traditional BMS technology primarily relies on monitoring temperature and voltage as a function of state of charge to establish cell SoS. However, this approach proves inadequate under abusive conditions, as it often fails to detect early degradation markers until catastrophic failure is imminent. The voltage profile of LIBs typically remains uniform until just before failure, making it challenging to identify critical changes in cell condition. Once significant deviations in voltage or temperature are observed, thermal runaway is often unavoidable, with few effective means of suppression or mitigation available. Electrochemical Impedance Spectroscopy (EIS) presents a promising avenue for assessing the SoS of electrochemical cells and battery packs. However, its application has been historically limited by the requirement for a pseudo-linear steady-state system, as dynamic changes in temperature or voltage can introduce noise and distort data. This limitation has constrained EIS to time-consuming full spectral measurements conducted on stationary batteries or single-frequency assessments that yield limited diagnostic insights. To address these challenges, researchers have developed a specialized impedance measurement tool capable of capturing impedance spectra at multiple discrete frequencies within ten to fifteen-second intervals. This rapid collection of EIS data is crucial for accurately establishing failure markers and enabling EIS to function as an onboard diagnostic tool. However, the effectiveness may diminish when transitioning from single cells to multi-cell packs, necessitating the integration of non-electrochemical diagnostics to enhance SoS assessments. Non-electrochemical diagnostics, particularly gas sensing, can provide valuable early warning signals, especially in large battery packs containing hundreds or thousands of cells. During thermal runaway, detectable gases typically include volatile organic compounds from electrolyte solvents, carbon dioxide, and hydrogen. The combination of gas sensing and rapid EIS has the potential to offer early warnings through effective SoS monitoring, thereby preventing catastrophic failures. In this study, we evaluate commercial gas sensors alongside rapid EIS to identify warning times for battery cells subjected to thermal and electrical abuse. The signals obtained from rapid EIS and gas sensing are correlated with live sampling conducted using Fourier Transform Infrared Spectrometry and Mass Spectrometry. This comprehensive gas analysis provides deeper insights into the failure mechanisms of abused cells and establishes a technical foundation for diagnostics that could be employed to monitor the SoS of both individual cells and entire battery packs. Throughout our experiments, we identify specific markers in the EIS and gas sensor data that correspond to the onset of unstable conditions. These markers could be integrated into a BMS or utilized to assess the SoS of batteries with unknown conditions. Identifying diagnostic tools that can pinpoint failure markers with sufficient lead time for intervention is critical for minimizing the consequences of LIB failures and enhancing the overall safety of electric vehicles. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology and Engineering Solutions of Sandia LLC, a wholly owned subsidiary of Honeywell International Inc. for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2024-16692A
- 11 July 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-01 (8) , 826
(Invited) Multiscale Safety Evaluation of Beyond Li-Ion Systems
The transition to commercialization of room-temperature, rechargeable batteries is accelerating, with new solutions such as solid-state and sodium-ion batteries always on the horizon. However, the safety characteristics of many emerging battery technologies remain insufficiently understood. This talk will address the gap by presenting findings from safety testing conducted on commercially available 18650 cells, alongside materials-scale analysis using samples ≤4 mm in diameter. Safety testing encompassed a range of temperature, mechanical, and electrical abuse conditions, including nail penetration, crush tests, external short circuits, overcharging, and overtemperature scenarios. Materials-scale degradation was characterized using techniques such as differential scanning calorimetry and thermogravimetric analysis, providing critical insights into reaction pathways and safety implications for next-generation energy storage systems.
- 11 July 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-01 (8) , 826
(Invited) Multiscale Safety Evaluation of Beyond Li-Ion Systems
The transition to commercialization of room-temperature, rechargeable batteries is accelerating, with new solutions such as solid-state and sodium-ion batteries always on the horizon. However, the safety characteristics of many emerging battery technologies remain insufficiently understood. This talk will address the gap by presenting findings from safety testing conducted on commercially available 18650 cells, alongside materials-scale analysis using samples ≤4 mm in diameter. Safety testing encompassed a range of temperature, mechanical, and electrical abuse conditions, including nail penetration, crush tests, external short circuits, overcharging, and overtemperature scenarios. Materials-scale degradation was characterized using techniques such as differential scanning calorimetry and thermogravimetric analysis, providing critical insights into reaction pathways and safety implications for next-generation energy storage systems.