Marine Ruffenach
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marine Ruffenach has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
- Julien Mekki
Centre National dEtudes Spatiales (CNES), Toulouse, France
11 shared publications - Francoise Bezerra
CNES, Toulouse, France
5 shared publications - Sebastien Bourdarie
ONERA/DPHY, Universit de Toulouse, Toulouse, France
5 shared publications - Hugo Cintas
Institute of Experimental and Applied Physics, Czech Technical University in Prague, 110 00 Prague, Czech Republic
4 shared publications J. Carron
Centre National dEtudes Spatiales (CNES), Toulouse, France
4 shared publications- Athina Varotsou
TRAD Tests and Radiations, Labge, France
3 shared publications
Latest Publications
- 4 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Optimisation de têtes de détection pour mesurer les protons et électrons des ceintures de radiations terrestres dans une gamme en énergie étendue
Les ceintures de radiation terrestres constituent un environnement radiatif naturel très dynamique, hostile aux satellites artificiels. Elles sont essentiellement composées d'électrons et de protons énergétiques (respectivement 10 keV-7 MeV et 10 keV-700 MeV). L'étude de cet environnement se prolonge depuis le début de l'ère spatiale afin de définir des spécifications de niveau de radiation reçu par les engins spatiaux au plus juste. Les mesures in-situ constituent donc un élément clé pour améliorer notre connaissance de ce milieu hostile. Le département DESP de l'ONERA, a participé à l'élaboration d'un moniteur de radiation avec le CNES, ICARE (Influence sur les Composants Avancés des Radiations dans l'Espace). Ce moniteur est toutefois trop lourd, trop encombrant et affiche une consommation trop élevée pour pouvoir être embarqué sur un Cubesat. De son côté le département IES de l'université de Montpellier a une forte expérience pour la définition et l'intégration de Cubesat à travers son CSU. Le but de cette thèse est donc de développer un moniteur de radiation léger, de faible encombrement, et de consommation compatible avec une plateforme Cubesat. Le challenge sera de mesurer un champ mixte d'électron et proton avec un capteur miniature. Le choix se portera sur un capteur Medipix, un détecteur composé de pixels hybrides silicium développé par le CERN. La thèse comportera plusieurs étapes clés. Une première consistera à simuler la réponse du capteur Medipix dans un champ mixte à partir d'un code de transport de particules chargées, GEANT-4. A partir de ces résultats théoriques il faudra proposer une stratégie d'utilisation du capteur. Celui-ci comporte une électronique particulièrement versatile qui autorise un grand nombre de méthodes d’acquisitions par pixels ou par groupes. Diverses techniques sont aussi jumelables (blindage discriminateur, association avec un système de coïncidence / anti coïncidence…) pour optimiser les capacités ou la sélectivité du capteur. Cette stratégie devra prendre en compte l’analyse de besoins des utilisateurs et de l’instrument (particules, gammes énergies, seuils de détection, facteurs géométriques…) ainsi que les contraintes liées à son intégration (nombre de gammes, traitement local pour limiter le volume de télémétrie…). Un deuxième volet consistera à proposer une architecture du moniteur conforme à une plateforme de type Cubesat (interfaces électroniques, blindages discriminateurs, traitement des informations collectées…). Finalement des expériences de calibration au sol du moniteur pourront être menées par exemple dans la chambre d'irradiation CHARM du CERN pour valider le concept. Cette thèse se déroulera à l'ONERA-DESP (centre de Toulouse) et à l'IES de l'université de Montpellier. Une codirection entre ONERA-DESP et Université de Montpellier/IES sera mise en place. La thèse sera menée dans le cadre d'une collaboration entre l'ONERA, l'Université de Montpellier, Le CSU de Montpellier-Nîmes, le CERN, et l'université technique de Prague.
- 4 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Optimisation de têtes de détection pour mesurer les protons et électrons des ceintures de radiations terrestres dans une gamme en énergie étendue
Les ceintures de radiation terrestres constituent un environnement radiatif naturel très dynamique, hostile aux satellites artificiels. Elles sont essentiellement composées d'électrons et de protons énergétiques (respectivement 10 keV-7 MeV et 10 keV-700 MeV). L'étude de cet environnement se prolonge depuis le début de l'ère spatiale afin de définir des spécifications de niveau de radiation reçu par les engins spatiaux au plus juste. Les mesures in-situ constituent donc un élément clé pour améliorer notre connaissance de ce milieu hostile. Le département DESP de l'ONERA, a participé à l'élaboration d'un moniteur de radiation avec le CNES, ICARE (Influence sur les Composants Avancés des Radiations dans l'Espace). Ce moniteur est toutefois trop lourd, trop encombrant et affiche une consommation trop élevée pour pouvoir être embarqué sur un Cubesat. De son côté le département IES de l'université de Montpellier a une forte expérience pour la définition et l'intégration de Cubesat à travers son CSU. Le but de cette thèse est donc de développer un moniteur de radiation léger, de faible encombrement, et de consommation compatible avec une plateforme Cubesat. Le challenge sera de mesurer un champ mixte d'électron et proton avec un capteur miniature. Le choix se portera sur un capteur Medipix, un détecteur composé de pixels hybrides silicium développé par le CERN. La thèse comportera plusieurs étapes clés. Une première consistera à simuler la réponse du capteur Medipix dans un champ mixte à partir d'un code de transport de particules chargées, GEANT-4. A partir de ces résultats théoriques il faudra proposer une stratégie d'utilisation du capteur. Celui-ci comporte une électronique particulièrement versatile qui autorise un grand nombre de méthodes d’acquisitions par pixels ou par groupes. Diverses techniques sont aussi jumelables (blindage discriminateur, association avec un système de coïncidence / anti coïncidence…) pour optimiser les capacités ou la sélectivité du capteur. Cette stratégie devra prendre en compte l’analyse de besoins des utilisateurs et de l’instrument (particules, gammes énergies, seuils de détection, facteurs géométriques…) ainsi que les contraintes liées à son intégration (nombre de gammes, traitement local pour limiter le volume de télémétrie…). Un deuxième volet consistera à proposer une architecture du moniteur conforme à une plateforme de type Cubesat (interfaces électroniques, blindages discriminateurs, traitement des informations collectées…). Finalement des expériences de calibration au sol du moniteur pourront être menées par exemple dans la chambre d'irradiation CHARM du CERN pour valider le concept. Cette thèse se déroulera à l'ONERA-DESP (centre de Toulouse) et à l'IES de l'université de Montpellier. Une codirection entre ONERA-DESP et Université de Montpellier/IES sera mise en place. La thèse sera menée dans le cadre d'une collaboration entre l'ONERA, l'Université de Montpellier, Le CSU de Montpellier-Nîmes, le CERN, et l'université technique de Prague.
- 14 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (8) , 2506-2512
Difference Between SET and SEU Thresholds Measured by SPA Laser Testing in a 16-nm FinFET Programmable SoC
We investigate the occurrence of SET in the programmable logic of a 16-nm FinFET SoC using SPA laser testing. Results indicate sensitive locations decorrelated from CRAM errors and a significant difference between SET and SEU thresholds. Correlation of these observations with available heavy ion results on the same technology is discussed. TCAD simulation results of SET in a single inverter are presented. Implications for SET rate prediction are discussed.
- 14 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (8) , 2506-2512
Difference Between SET and SEU Thresholds Measured by SPA Laser Testing in a 16-nm FinFET Programmable SoC
We investigate the occurrence of SET in the programmable logic of a 16-nm FinFET SoC using SPA laser testing. Results indicate sensitive locations decorrelated from CRAM errors and a significant difference between SET and SEU thresholds. Correlation of these observations with available heavy ion results on the same technology is discussed. TCAD simulation results of SET in a single inverter are presented. Implications for SET rate prediction are discussed.
- 10 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (8) , 2480-2489
Investigation of the Limits of the Ray-Tracing Method Applied on Dose Analysis for Radiation Hardness Assurance
Radiation hardness assurance (RHA) is critical for a space project as it ensures that electronics will perform to their design specifications during exposure to the mission’s radiation environment. The ray-tracing method (or sector analysis) is commonly used by radiation engineers to estimate the dose at electronic component level, however it relies on specific hypotheses. In this paper, the limits of the ray-tracing method are investigated to understand how the method can be improved and to propose recommendations for the dose calculation. As a first step, the impact of the shielding sectoring resolution is explored and the results are compared to the recommendations of the ECSS-E-ST-10-12C. The second part of the paper investigates the influence of the shielding material on the dose curve computation, the main input of the ray-tracing calculation. Finally, the role of the spacing between different materials as well as the distribution of materials along the particle path is explored.
- 10 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (8) , 2480-2489
Investigation of the Limits of the Ray-Tracing Method Applied on Dose Analysis for Radiation Hardness Assurance
Radiation hardness assurance (RHA) is critical for a space project as it ensures that electronics will perform to their design specifications during exposure to the mission’s radiation environment. The ray-tracing method (or sector analysis) is commonly used by radiation engineers to estimate the dose at electronic component level, however it relies on specific hypotheses. In this paper, the limits of the ray-tracing method are investigated to understand how the method can be improved and to propose recommendations for the dose calculation. As a first step, the impact of the shielding sectoring resolution is explored and the results are compared to the recommendations of the ECSS-E-ST-10-12C. The second part of the paper investigates the influence of the shielding material on the dose curve computation, the main input of the ray-tracing calculation. Finally, the role of the spacing between different materials as well as the distribution of materials along the particle path is explored.
- Open Access
- 13 November 2024
- Published by EDP Sciences in Journal of Space Weather and Space Climate
- Vol. 14, 35
ARAMIS: a Martian radiative environment model built from GEANT4 simulations
A new model of the Martian surface radiative environment has been built: Atmospheric RAdiation Model for Ionizing spectra on martian Surface (ARAMIS). Based on Monte Carlo calculations, it offers high computational flexibility for surface flux spectra with several GEANT4 physics lists tested for different exposures and mission scenarios. ARAMIS performs Monte Carlo simulations independently of any exposure scenario to determine a surface response function that can then be convolved to any input spectrum, avoiding simulation repetition while maintaining results accuracy, using a parametric atmosphere geometry. In particular, the adopted approach enables secondary spectra to be discriminated by type and origin, in order to observe the impact of different primary flux components on the surface dose calculation. The ARAMIS model has been validated with experimental measurements from the RAD (Radiation Assessment Detector) instrument on board the Mars Science Laboratory (MSL) Curiosity rover, and benchmarked against other models in the literature. Built using version 11.1.0 of the GEometry ANd Tracking (GEANT4) toolbox and established models of Galactic Cosmic Ray (GCR) or Solar Particle Event (SEP) spectra, the surface neutron and photon spectra provided by ARAMIS show a better agreement than other models with high-energy experimental data, reducing model uncertainty for radiation protection calculations.
- 13 November 2024
- Published by EDP Sciences in Journal of Space Weather and Space Climate
- Vol. 14, 35
Open AccessARAMIS: a Martian radiative environment model built from GEANT4 simulations
A new model of the Martian surface radiative environment has been built: Atmospheric RAdiation Model for Ionizing spectra on martian Surface (ARAMIS). Based on Monte Carlo calculations, it offers high computational flexibility for surface flux spectra with several GEANT4 physics lists tested for different exposures and mission scenarios. ARAMIS performs Monte Carlo simulations independently of any exposure scenario to determine a surface response function that can then be convolved to any input spectrum, avoiding simulation repetition while maintaining results accuracy, using a parametric atmosphere geometry. In particular, the adopted approach enables secondary spectra to be discriminated by type and origin, in order to observe the impact of different primary flux components on the surface dose calculation. The ARAMIS model has been validated with experimental measurements from the RAD (Radiation Assessment Detector) instrument on board the Mars Science Laboratory (MSL) Curiosity rover, and benchmarked against other models in the literature. Built using version 11.1.0 of the GEometry ANd Tracking (GEANT4) toolbox and established models of Galactic Cosmic Ray (GCR) or Solar Particle Event (SEP) spectra, the surface neutron and photon spectra provided by ARAMIS show a better agreement than other models with high-energy experimental data, reducing model uncertainty for radiation protection calculations.
- 19 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (8) , 1638-1644
Proton, Electron, and Photon Flux Measurement and Simulation During Stratospheric Balloon Flights
This paper compares three models of the atmospheric radiative environment: MAIRE (Model of Atmospheric Ionizing Radiative Effects), EXPACS (Excel-based Program for calculating Atmospheric Cosmic-ray Spectrum) and RAMSEES (Radiation Atmospheric Model for Single Event Effect Simulation) to experimental fluxes measured at different altitudes. The PIX CNES (Centre National d’Etudes Spatiales) instrument recorded the fluxes during five stratospheric flights. There is no standard way to model the atmospheric radiative environment today. Each model uses its own Monte Carlo toolkit, modeling the atmosphere and primary particles. The Radiations Atmospheric Model for SEE Simulation (RAMSEES) was created by Geant4 simulation of the Extensive Air Shower (EAS) phenomenon generated by highly energetic Galactic Cosmic Rays (GCR) in 100 km of atmosphere. By using PIX fluxes, this paper aims to benchmark the models with experimental data at multiple altitudes. Three integral fluxes were used in this paper at a comparison point: photons >0.823 MeV, electrons >10.27 MeV, and protons >80 MeV. MAIRE shows good agreement with all the experimental fluxes from 5 to 40 km. MAIRE predictions show remarkable agreement with the PIX photon fluxes. EXPACS predictions are in a magnitude order of PIX measurements but tend to underestimate the fluxes. Finally, RAMSEES predictions agree with PIX fluxes for protons, electrons, and photons at altitudes of 5 to 32.5 km. Moreover, RAMSEES shows a significant agreement with PIX proton fluxes.
- 19 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (8) , 1638-1644
Proton, Electron, and Photon Flux Measurement and Simulation During Stratospheric Balloon Flights
This paper compares three models of the atmospheric radiative environment: MAIRE (Model of Atmospheric Ionizing Radiative Effects), EXPACS (Excel-based Program for calculating Atmospheric Cosmic-ray Spectrum) and RAMSEES (Radiation Atmospheric Model for Single Event Effect Simulation) to experimental fluxes measured at different altitudes. The PIX CNES (Centre National d’Etudes Spatiales) instrument recorded the fluxes during five stratospheric flights. There is no standard way to model the atmospheric radiative environment today. Each model uses its own Monte Carlo toolkit, modeling the atmosphere and primary particles. The Radiations Atmospheric Model for SEE Simulation (RAMSEES) was created by Geant4 simulation of the Extensive Air Shower (EAS) phenomenon generated by highly energetic Galactic Cosmic Rays (GCR) in 100 km of atmosphere. By using PIX fluxes, this paper aims to benchmark the models with experimental data at multiple altitudes. Three integral fluxes were used in this paper at a comparison point: photons >0.823 MeV, electrons >10.27 MeV, and protons >80 MeV. MAIRE shows good agreement with all the experimental fluxes from 5 to 40 km. MAIRE predictions show remarkable agreement with the PIX photon fluxes. EXPACS predictions are in a magnitude order of PIX measurements but tend to underestimate the fluxes. Finally, RAMSEES predictions agree with PIX fluxes for protons, electrons, and photons at altitudes of 5 to 32.5 km. Moreover, RAMSEES shows a significant agreement with PIX proton fluxes.
- 10 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (8) , 1631-1637
Benchmarking Trapped Proton Specification Models Along an EOR Orbit
Eutelsat 7C (E7C), a telecommunication spacecraft, was launched on 21 st of June 2019 and reached geostationary (GEO) orbit four months later after a quasi-equatorial electric orbit raising (EOR) phase. An ICARE-NG (Influence sur les Composant Avancés des Radiations de l’Espace, Nouvelle Génération) radiation monitor was implemented on the spacecraft allowing measurements of electron and proton flux as well as Single Event Upset (SEU) effect affecting various static random access memories (SRAMs) and dynamic random access memories (DRAMs). According to the cruise to GEO profile, two phases could be deduced, a first one where SEU events are dominated by trapped protons and a second one where they are attributed to cosmic rays and solar proton events. In this paper, SEU events attributed to trapped particles as well as proton flux recorded by ICARE-NG are used to benchmark proton specification models, Aerospace Proton version 8 (AP8), Aerospace Proton version 9 (AP9) and Global Radiation Earth ENvironment-proton (GREEN-p). Although, the 3D shielding of the spacecraft and payload is considered to transport accurately the proton environment down to the chip, ground tests to define cross section were not reliable enough to draw clear conclusion on specification model performances along EOR orbits.
- 10 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (8) , 1631-1637
Benchmarking Trapped Proton Specification Models Along an EOR Orbit
Eutelsat 7C (E7C), a telecommunication spacecraft, was launched on 21 st of June 2019 and reached geostationary (GEO) orbit four months later after a quasi-equatorial electric orbit raising (EOR) phase. An ICARE-NG (Influence sur les Composant Avancés des Radiations de l’Espace, Nouvelle Génération) radiation monitor was implemented on the spacecraft allowing measurements of electron and proton flux as well as Single Event Upset (SEU) effect affecting various static random access memories (SRAMs) and dynamic random access memories (DRAMs). According to the cruise to GEO profile, two phases could be deduced, a first one where SEU events are dominated by trapped protons and a second one where they are attributed to cosmic rays and solar proton events. In this paper, SEU events attributed to trapped particles as well as proton flux recorded by ICARE-NG are used to benchmark proton specification models, Aerospace Proton version 8 (AP8), Aerospace Proton version 9 (AP9) and Global Radiation Earth ENvironment-proton (GREEN-p). Although, the 3D shielding of the spacecraft and payload is considered to transport accurately the proton environment down to the chip, ground tests to define cross section were not reliable enough to draw clear conclusion on specification model performances along EOR orbits.
- 22 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (8) , 1645-1653
Analysis of the Single-Event Latch-Up Cross section of a 16 nm FinFET System-on-Chip Using Backside Single-Photon Absorption Laser Testing and Correlation With Heavy Ion Data
The single-event latch-up (SEL) cross section of a 16nm bulk finFET programmable system-on-chip (SoC) is investigated by combining single photon absorption (SPA) laser testing, emission microscopy and embedded instrumentation. The contributions of different SEL-sensitive areas identified by their current increase, light emission and functional signatures are measured. The effect of temperature and IO bias is evaluated. The laser results show an excellent correlation with heavy ion data, and delimit the origin of SEL in this device by excluding the occurrence of SEL in the core-logic for this technology.
- 22 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (8) , 1645-1653
Analysis of the Single-Event Latch-Up Cross section of a 16 nm FinFET System-on-Chip Using Backside Single-Photon Absorption Laser Testing and Correlation With Heavy Ion Data
The single-event latch-up (SEL) cross section of a 16nm bulk finFET programmable system-on-chip (SoC) is investigated by combining single photon absorption (SPA) laser testing, emission microscopy and embedded instrumentation. The contributions of different SEL-sensitive areas identified by their current increase, light emission and functional signatures are measured. The effect of temperature and IO bias is evaluated. The laser results show an excellent correlation with heavy ion data, and delimit the origin of SEL in this device by excluding the occurrence of SEL in the core-logic for this technology.
- 22 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (8) , 1527-1534
PIX: An Instrument to Measure Atmospheric Ionizing Particles Based on a Single MiniPIX Sensor
This paper presents the PIX instrument based on a raspberry Pi and a MiniPIX device dedicated to make measurements of ionizing particles onboard stratospheric balloons. The hardware part and the software part of the PIX instrument are described. All the characteristics of the instrument are given in this paper. The three flight opportunities are also presented, with the associated measurements. The methodology to calculate fluxes based on measurements is explained. In particular, the calculation of response functions of protons, electrons, and photons by using Monte-Carlo simulations, the identification algorithm based on a neural network trained with simulated data, and the calculation of fluxes from count rates are described. Some measurements performed in different facilities are presented. A part of these experimental tracks have been used to challenge the neural network previously trained with simulated date, to check the robustness of the algorithm. Proton, electron, and photon fluxes are presented and compared to the MAIRE model.
- 22 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (8) , 1527-1534
PIX: An Instrument to Measure Atmospheric Ionizing Particles Based on a Single MiniPIX Sensor
This paper presents the PIX instrument based on a raspberry Pi and a MiniPIX device dedicated to make measurements of ionizing particles onboard stratospheric balloons. The hardware part and the software part of the PIX instrument are described. All the characteristics of the instrument are given in this paper. The three flight opportunities are also presented, with the associated measurements. The methodology to calculate fluxes based on measurements is explained. In particular, the calculation of response functions of protons, electrons, and photons by using Monte-Carlo simulations, the identification algorithm based on a neural network trained with simulated data, and the calculation of fluxes from count rates are described. Some measurements performed in different facilities are presented. A part of these experimental tracks have been used to challenge the neural network previously trained with simulated date, to check the robustness of the algorithm. Proton, electron, and photon fluxes are presented and compared to the MAIRE model.
- 20 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (8) , 1535-1541
In-Flight Measurements of Radiation Environment Observed by Hotbird 13F and Hotbird 13G (Electric Orbit Raising Satellites)
Measurements of particle fluxes obtained with the latest version of Influence sur les Composants Avancés des Radiations de l’Espace (ICARE), called ICARE_NG², onboard Hotbird 13F and Hotbird 13G satellites, are presented. Compared to previous versions of ICARE, a wider range of particle energies is measured. Indeed, low-energy protons are now available, down to ~ 5 MeV. The missions consist of Electric Orbit Raising (EOR) phases (launched at the end of 2023), followed by an operational orbit in Geostationary Orbit (GEO). The EOR periods are analyzed through a series of comparisons. Very good agreements are observed with other instruments while significant discrepancies are found with engineering models as AE/P8, AE/P9 and Global Radiation Earth Environnement (GREEN). The average fluxes recorded during the EOR phases are presented and compared with the engineering models. None of the models used can accurately reproduce the observed fluxes. Such results will help to optimize specifications for future space missions.
- 20 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (8) , 1535-1541
In-Flight Measurements of Radiation Environment Observed by Hotbird 13F and Hotbird 13G (Electric Orbit Raising Satellites)
Measurements of particle fluxes obtained with the latest version of Influence sur les Composants Avancés des Radiations de l’Espace (ICARE), called ICARE_NG², onboard Hotbird 13F and Hotbird 13G satellites, are presented. Compared to previous versions of ICARE, a wider range of particle energies is measured. Indeed, low-energy protons are now available, down to ~ 5 MeV. The missions consist of Electric Orbit Raising (EOR) phases (launched at the end of 2023), followed by an operational orbit in Geostationary Orbit (GEO). The EOR periods are analyzed through a series of comparisons. Very good agreements are observed with other instruments while significant discrepancies are found with engineering models as AE/P8, AE/P9 and Global Radiation Earth Environnement (GREEN). The average fluxes recorded during the EOR phases are presented and compared with the engineering models. None of the models used can accurately reproduce the observed fluxes. Such results will help to optimize specifications for future space missions.
- 5 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (8) , 1541-1547
DREAM: A Miniaturized Spectrometer for Measurement of Protons and Electrons on Orbit
CNES (Centre National d’Etudes Spatiales) is currently developing a new instrument called DREAM (Détecteur Radiation Energétique Adaptable et Miniaturisé) in order to measure electrons and protons in the Earth magnetosphere. Compared to the instrument ICARE-NG (Influence sur les Composants Avancés des Radiations de l’Espace - Nouvelle Génération), DREAM is compatible with nanosatellite cubesats. In this article, we present the instrument architecture, new sensors design, hardware improvements and first results. Response functions for protons and electrons sensors are calculated using GEANT4 (Geometry And Tracking) simulations. The calculation of predicted count rates of particles is performed.
- 5 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (8) , 1541-1547
DREAM: A Miniaturized Spectrometer for Measurement of Protons and Electrons on Orbit
CNES (Centre National d’Etudes Spatiales) is currently developing a new instrument called DREAM (Détecteur Radiation Energétique Adaptable et Miniaturisé) in order to measure electrons and protons in the Earth magnetosphere. Compared to the instrument ICARE-NG (Influence sur les Composants Avancés des Radiations de l’Espace - Nouvelle Génération), DREAM is compatible with nanosatellite cubesats. In this article, we present the instrument architecture, new sensors design, hardware improvements and first results. Response functions for protons and electrons sensors are calculated using GEANT4 (Geometry And Tracking) simulations. The calculation of predicted count rates of particles is performed.