Rahim Jafari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rahim Jafari has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Mital Kanabar
Power Engineering, PowerProfs Inc., Markham, ON, Canada
2 shared publications - Tarlochan Sing Sidhu
Applied Science, University of Ontario Institute of Technology Faculty of Engineering and Applied Science, 177389 Oshawa, Ontario Canada
2 shared publications - Ilia Voloh
Technology, GE Digital Energy, Markham, Ontario Canada L6C 0M1
1 shared publication
Latest Publications
- 18 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (6) , 6197-6205
Neutral Grounding Resistor Monitoring State-of-the-Art
Neutral grounding resistors are used to overcome safety concerns and equipment stress by controlling transient overvoltages and limiting ground overcurrents. Failure of these apparatuses is an undetected event in unfaulted condition which causes many challenges in case of ground faults. Recently, various monitoring methods have emerged to solve this issue. The literature and current state of this art are the main targets of this research work which classifies all existing methods into three categories based on the used measurement instruments and operation characteristics. In this paper, each of these methods are explained briefly including the used measurement instruments, monitoring scheme and few performance results. Further, the evolution trend of these methods is demonstrated as well as a thorough comparison based on their performance under various conditions.
- 18 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (6) , 6197-6205
Neutral Grounding Resistor Monitoring State-of-the-Art
Neutral grounding resistors are used to overcome safety concerns and equipment stress by controlling transient overvoltages and limiting ground overcurrents. Failure of these apparatuses is an undetected event in unfaulted condition which causes many challenges in case of ground faults. Recently, various monitoring methods have emerged to solve this issue. The literature and current state of this art are the main targets of this research work which classifies all existing methods into three categories based on the used measurement instruments and operation characteristics. In this paper, each of these methods are explained briefly including the used measurement instruments, monitoring scheme and few performance results. Further, the evolution trend of these methods is demonstrated as well as a thorough comparison based on their performance under various conditions.
- 23 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (4) , 1341-1349
A Continuous Monitoring for Neutral Grounding Resistors and Reactors With Hardware Validation
Neutral grounding devices are used to limit ground overcurrents, control transient overvoltages, and overcome the consequent issues. Intactness of these apparatuses is vital to prevent the risk of ungrounded or solidly grounded neutral. As such, they should be continuously monitored as targeted here. This paper proposes a continuous monitoring technique which supervises the NGD impedance obtained via full-range voltage and current measurement. It benefits from a new and cost-effective voltage metering mechanism specifically designed for the studied problem. Its performance has been validated using a fabricated prototype. In contrast to existing methods, the application of the proposed technique is not limited to a specific configuration, system operation mode, or neutral grounding device. Furthermore, monitoring is performed without signal injection. This monitoring technique shows reliable operation under various conditions of the system and grounding apparatuses based on the analysis performed using PSCAD in conjunction with MATLAB.
- 23 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (4) , 1341-1349
A Continuous Monitoring for Neutral Grounding Resistors and Reactors With Hardware Validation
Neutral grounding devices are used to limit ground overcurrents, control transient overvoltages, and overcome the consequent issues. Intactness of these apparatuses is vital to prevent the risk of ungrounded or solidly grounded neutral. As such, they should be continuously monitored as targeted here. This paper proposes a continuous monitoring technique which supervises the NGD impedance obtained via full-range voltage and current measurement. It benefits from a new and cost-effective voltage metering mechanism specifically designed for the studied problem. Its performance has been validated using a fabricated prototype. In contrast to existing methods, the application of the proposed technique is not limited to a specific configuration, system operation mode, or neutral grounding device. Furthermore, monitoring is performed without signal injection. This monitoring technique shows reliable operation under various conditions of the system and grounding apparatuses based on the analysis performed using PSCAD in conjunction with MATLAB.