Mital Kanabar
Research Subjects
Research Interests
Mital Kanabar has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Manoj Tripathy
Department of Electrical Engineering, Indian Institute of Technology Roorkee, Roorkee, India
2 shared publications - Rahim Jafari
Electrical and Computer Engineering Department, University of Western Ontario, London, Ontario Canada
2 shared publications - Suresh Mogilicharla
Electrical Engineering, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand, INDIA
2 shared publications - Tarlochan Sing Sidhu
Applied Science, University of Ontario Institute of Technology Faculty of Engineering and Applied Science, 177389 Oshawa, Ontario Canada
2 shared publications - Ali Azizi
Department of Electrical and Computer Engineering, University of Toronto, Toronto, ON, Canada
1 shared publication - Ali Hooshyar
Department of Electrical and Computer Engineering, University of Toronto, Toronto, ON, Canada
1 shared publication
Latest Publications
- 27 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (2) , 3673-3683
Edge-Deployable ML Agent for Real-Time Tactic and Technique Attribution in Microgrid Security
The proliferation of microgrids increases exposure to advanced persistent threats (APTs) that evolve through structured adversarial stages defined by tactics and techniques. While the MITRE ATT&CK for ICS framework offers a comprehensive threat taxonomy, its integration into edge-level Intrusion Detection Systems (IDSs) remains limited. Existing IDSs mainly perform binary classification (benign vs. malicious) and depend heavily on centralized Security Operations Centers (SOCs) for contextual analysis and response. This work proposes a machine learning-based agent for real-time attribution of adversarial tactics and techniques, leveraging the MITRE ATT&CK framework. Designed as an add-on to existing IDSs, the agent ingests alerts in the standardized Intrusion Detection Message Exchange Format (IDMEF). Its effectiveness is validated through integration with a realistic microgrid environment, supported by real-time experimental data and edge deployment on a Raspberry Pi. A comparative study of classifiers, SVM, Random Forest, Decision Tree, Naïve Bayes, and XGBoost has been conducted, with feature selection optimized using Binary Particle Swarm Optimization (BPSO). XGBoost achieved the highest classification accuracy of 98% with an inference latency of 15 ms, and minimal CPU (16.2%) and memory (1.7%) utilization, demonstrating its suitability for resource-constrained edge devices. The results are visualized in Grafana, enabling proactive, tactic-aware defense and improving local situational awareness while reducing dependency on cloud-based SOCs.
- 27 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (2) , 3673-3683
Edge-Deployable ML Agent for Real-Time Tactic and Technique Attribution in Microgrid Security
The proliferation of microgrids increases exposure to advanced persistent threats (APTs) that evolve through structured adversarial stages defined by tactics and techniques. While the MITRE ATT&CK for ICS framework offers a comprehensive threat taxonomy, its integration into edge-level Intrusion Detection Systems (IDSs) remains limited. Existing IDSs mainly perform binary classification (benign vs. malicious) and depend heavily on centralized Security Operations Centers (SOCs) for contextual analysis and response. This work proposes a machine learning-based agent for real-time attribution of adversarial tactics and techniques, leveraging the MITRE ATT&CK framework. Designed as an add-on to existing IDSs, the agent ingests alerts in the standardized Intrusion Detection Message Exchange Format (IDMEF). Its effectiveness is validated through integration with a realistic microgrid environment, supported by real-time experimental data and edge deployment on a Raspberry Pi. A comparative study of classifiers, SVM, Random Forest, Decision Tree, Naïve Bayes, and XGBoost has been conducted, with feature selection optimized using Binary Particle Swarm Optimization (BPSO). XGBoost achieved the highest classification accuracy of 98% with an inference latency of 15 ms, and minimal CPU (16.2%) and memory (1.7%) utilization, demonstrating its suitability for resource-constrained edge devices. The results are visualized in Grafana, enabling proactive, tactic-aware defense and improving local situational awareness while reducing dependency on cloud-based SOCs.
- 28 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (4) , 5430-5444
Integrating Cyber and Physical Analysis for Intrusion Detection in Plant-Level DER Microgrids
The growing use of distributed energy resources (DERs) is reshaping the energy industry by enabling a more decentralized and sustainable energy ecosystem. However, integrating these technologies with the electric grid heavily relies on communication systems, thereby exposing them to heightened cybersecurity threats, and so does the necessity for robust cybersecurity measures. This paper presents a hybrid Intrusion Detection System (IDS) that utilizes data from three critical sources: host devices, network traffic, and physical power system measurements, to provide accurate detection of cyber threats. The IDS is specifically designed to detect anomalies in inverterbased DER systems that utilize the Modbus protocol. Each of the three analysis engines has a set of rules that serve as signatures to identify abnormalities. The implementation leverages opensource tools, ensuring flexibility and ease of integration into existing systems. A laboratory-scale microgrid test bed that resembles a hospital microgrid environment is used to validate the proposed IDS. A comprehensive set of test scenarios that encompass realistic and practical circumstances is used to evaluate the efficacy of the IDS. The findings show that the proposed IDS achieved 100% detection accuracy with an average response time of ≤ 1.5 seconds, demonstrating high performance and costeffective deployment on resource-constrained hardware.
- 28 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (4) , 5430-5444
Integrating Cyber and Physical Analysis for Intrusion Detection in Plant-Level DER Microgrids
The growing use of distributed energy resources (DERs) is reshaping the energy industry by enabling a more decentralized and sustainable energy ecosystem. However, integrating these technologies with the electric grid heavily relies on communication systems, thereby exposing them to heightened cybersecurity threats, and so does the necessity for robust cybersecurity measures. This paper presents a hybrid Intrusion Detection System (IDS) that utilizes data from three critical sources: host devices, network traffic, and physical power system measurements, to provide accurate detection of cyber threats. The IDS is specifically designed to detect anomalies in inverterbased DER systems that utilize the Modbus protocol. Each of the three analysis engines has a set of rules that serve as signatures to identify abnormalities. The implementation leverages opensource tools, ensuring flexibility and ease of integration into existing systems. A laboratory-scale microgrid test bed that resembles a hospital microgrid environment is used to validate the proposed IDS. A comprehensive set of test scenarios that encompass realistic and practical circumstances is used to evaluate the efficacy of the IDS. The findings show that the proposed IDS achieved 100% detection accuracy with an average response time of ≤ 1.5 seconds, demonstrating high performance and costeffective deployment on resource-constrained hardware.
- 23 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power and Energy Magazine
- Vol. 22 (2) , 90-99
Building the Grid of the Future to Accelerate Energy Transition: Innovations and Digital Transformation for Global Utilities
The energy industry is undergoing a significant transition from fossil fuel to sustainable energy sources, driven by decarbonization, as well as the United Nation’s Sustainable Development Goals, such as climate action and affordable and clean energy initiatives. Energy transition needs to balance an energy trilemma problem among energy security (including reliability and resilience), affordability or equity, and environmental sustainability. The energy transition is at hand, but its success relies on our ability to adapt our aging power grid infrastructure to support the entire ecosystem around it. Innovation and the digital transformation of the grid substation are crucial to evolving our technology rapidly enough to meet the world’s rising demands of green energy.
- 23 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power and Energy Magazine
- Vol. 22 (2) , 90-99
Building the Grid of the Future to Accelerate Energy Transition: Innovations and Digital Transformation for Global Utilities
The energy industry is undergoing a significant transition from fossil fuel to sustainable energy sources, driven by decarbonization, as well as the United Nation’s Sustainable Development Goals, such as climate action and affordable and clean energy initiatives. Energy transition needs to balance an energy trilemma problem among energy security (including reliability and resilience), affordability or equity, and environmental sustainability. The energy transition is at hand, but its success relies on our ability to adapt our aging power grid infrastructure to support the entire ecosystem around it. Innovation and the digital transformation of the grid substation are crucial to evolving our technology rapidly enough to meet the world’s rising demands of green energy.
- 3 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (6) , 4090-4102
Impact of Inverter-Based Resources on Different Implementation Methods for Distance Relays—Part I: Phase Comparators
Unconventional fault currents of inverter-based resources (IBRs) can adversely impact distance relays. Despite extensive investigation in the literature, the available studies on this topic mostly suffer from three main shortcomings: (i) they consider only the apparent-impedance-based implementation method of distance protection and do not cover the methods used by relay manufacturers to realize the distance element, (ii) they focus on only the relays that protect the direct tie-lines of IBRs, severely limiting the benefits of these studies for future IBR-centric grids, and (iii) they do not consider the requirements of recent grid codes and standards for the low-voltage ride-through current of IBRs. This article addresses these three shortcomings. Part I of this article is on distance relays that use phase comparators.
- 3 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (6) , 4090-4102
Impact of Inverter-Based Resources on Different Implementation Methods for Distance Relays—Part I: Phase Comparators
Unconventional fault currents of inverter-based resources (IBRs) can adversely impact distance relays. Despite extensive investigation in the literature, the available studies on this topic mostly suffer from three main shortcomings: (i) they consider only the apparent-impedance-based implementation method of distance protection and do not cover the methods used by relay manufacturers to realize the distance element, (ii) they focus on only the relays that protect the direct tie-lines of IBRs, severely limiting the benefits of these studies for future IBR-centric grids, and (iii) they do not consider the requirements of recent grid codes and standards for the low-voltage ride-through current of IBRs. This article addresses these three shortcomings. Part I of this article is on distance relays that use phase comparators.
- 18 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (6) , 6197-6205
Neutral Grounding Resistor Monitoring State-of-the-Art
Neutral grounding resistors are used to overcome safety concerns and equipment stress by controlling transient overvoltages and limiting ground overcurrents. Failure of these apparatuses is an undetected event in unfaulted condition which causes many challenges in case of ground faults. Recently, various monitoring methods have emerged to solve this issue. The literature and current state of this art are the main targets of this research work which classifies all existing methods into three categories based on the used measurement instruments and operation characteristics. In this paper, each of these methods are explained briefly including the used measurement instruments, monitoring scheme and few performance results. Further, the evolution trend of these methods is demonstrated as well as a thorough comparison based on their performance under various conditions.
- 18 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (6) , 6197-6205
Neutral Grounding Resistor Monitoring State-of-the-Art
Neutral grounding resistors are used to overcome safety concerns and equipment stress by controlling transient overvoltages and limiting ground overcurrents. Failure of these apparatuses is an undetected event in unfaulted condition which causes many challenges in case of ground faults. Recently, various monitoring methods have emerged to solve this issue. The literature and current state of this art are the main targets of this research work which classifies all existing methods into three categories based on the used measurement instruments and operation characteristics. In this paper, each of these methods are explained briefly including the used measurement instruments, monitoring scheme and few performance results. Further, the evolution trend of these methods is demonstrated as well as a thorough comparison based on their performance under various conditions.
- 23 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (4) , 1341-1349
A Continuous Monitoring for Neutral Grounding Resistors and Reactors With Hardware Validation
Neutral grounding devices are used to limit ground overcurrents, control transient overvoltages, and overcome the consequent issues. Intactness of these apparatuses is vital to prevent the risk of ungrounded or solidly grounded neutral. As such, they should be continuously monitored as targeted here. This paper proposes a continuous monitoring technique which supervises the NGD impedance obtained via full-range voltage and current measurement. It benefits from a new and cost-effective voltage metering mechanism specifically designed for the studied problem. Its performance has been validated using a fabricated prototype. In contrast to existing methods, the application of the proposed technique is not limited to a specific configuration, system operation mode, or neutral grounding device. Furthermore, monitoring is performed without signal injection. This monitoring technique shows reliable operation under various conditions of the system and grounding apparatuses based on the analysis performed using PSCAD in conjunction with MATLAB.
- 23 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (4) , 1341-1349
A Continuous Monitoring for Neutral Grounding Resistors and Reactors With Hardware Validation
Neutral grounding devices are used to limit ground overcurrents, control transient overvoltages, and overcome the consequent issues. Intactness of these apparatuses is vital to prevent the risk of ungrounded or solidly grounded neutral. As such, they should be continuously monitored as targeted here. This paper proposes a continuous monitoring technique which supervises the NGD impedance obtained via full-range voltage and current measurement. It benefits from a new and cost-effective voltage metering mechanism specifically designed for the studied problem. Its performance has been validated using a fabricated prototype. In contrast to existing methods, the application of the proposed technique is not limited to a specific configuration, system operation mode, or neutral grounding device. Furthermore, monitoring is performed without signal injection. This monitoring technique shows reliable operation under various conditions of the system and grounding apparatuses based on the analysis performed using PSCAD in conjunction with MATLAB.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 345-352
Lessons learned while applying electric protection on an offshore platform
Offshore platforms have critical and isolated electrical power supply system including large direct-online motors connected to the generation bus. This paper discusses complications involved in applying protection systems including generator and generator-transformer differentials in coordination with motor starting and motor protection for such applications. Recommendations are provided for applying effective protection system, simplification of configurations to reduce errors, access of events and records to perform diagnosis etc. using digital protection relay on an offshore platform. This paper also highlights Monitoring and Diagnosis (M&D) for the electrical assets on offshore platforms.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 345-352
Lessons learned while applying electric protection on an offshore platform
Offshore platforms have critical and isolated electrical power supply system including large direct-online motors connected to the generation bus. This paper discusses complications involved in applying protection systems including generator and generator-transformer differentials in coordination with motor starting and motor protection for such applications. Recommendations are provided for applying effective protection system, simplification of configurations to reduce errors, access of events and records to perform diagnosis etc. using digital protection relay on an offshore platform. This paper also highlights Monitoring and Diagnosis (M&D) for the electrical assets on offshore platforms.