YXYue Xu

Yue Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yue Xu has a total of 70 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Oil-impregnated densified wood veneer with high electrical insulation enabled by nanosized oil channels

    by Meiling Wu, Yue Xu, Qian Zhang, Alexandra Brozena, Yimin Mao, Yu Liu, Lin Xu, Soori Tejaswi, Yugang Zhang, Xinpeng Zhao, et al.

    Growing energy demands and renewable integration are stressing the aging power grid infrastructure. Lignocellulosic oil-impregnated paper is widely used in power transformers but suffers from critical limitations, such as low dielectric strength, mechanical strength, and thermal conductivity, causing premature transformer failures. Here, we demonstrate a superior electrically insulating oil-impregnated paper design using the naturally anisotropic structure of densified wood veneer to achieve nanosized channels of oil that efficiently disrupt electrical breakdown pathways. The developed oil-impregnated densified wood (ODW) creates aligned cellulose fibers with 166 ± 87–nanometer oil nanochannels, achieving record dielectric strength of 105 kilovolts per millimeter. The structure also delivers a mechanical strength of up to 384 megapascals and a thermal conductivity of 0.33 watts per meter per kelvin, enabling enhanced longevity upon thermal aging tests. The ODW could replace conventional transformer insulation to enhance power transformer performance and improve lifetime. Moreover, its anisotropic oil-filled nanochannel design offers a general strategy for hybrid dielectrics in medium- and high-voltage applications.


  • Open Access

    Electrical Breakdown Analysis of Emerging Oil–Paper Insulation Systems

    by Yue Xu, Soori Tejaswi, Kent Davey, Qian Zhang, Vaibhav Bahadur, Junyong Zhu, Robert Hebner, Zhedong Han, Felix Lin, Liangbing Hu

    This investigation addresses the effect of particulate additives on the electrical breakdown strength of the oil impregnated insulation paper system. The morphological complexity is addressed by converting data from scanning electron microscope images to a data set suitable for numerical simulation analysis. Then, by using the conventional oil‐triggered breakdown assumption, the breakdown strength of the proposed hybrid insulation system was calculated. As a result, it demonstrates that the introduction of particles can redefine the electric field distribution in the hybrid insulation system under study. Consequently, a higher applied voltage is needed for the electrical breakdown to occur in the hybrid system with proper selection and addition of particles. This analysis method builds on the existing understanding of the electrical breakdown phenomena for oil impregnated insulation paper system, explains recent experimental data and supports improvements of material design in the future.

  • Open Access

    Critical properties enhancement of oil-paper transformer insulation with turbostratic boron nitride

    by Yue Xu, Qian Zhang, Tejaswi Soori, J.Y. Zhu, J. Keith Nelson, Liangbing Hu, Vaibhav Bahadur, Robert Hebner


  • Open Access

    Boron nitride enhanced electric insulation paper for extending transformer thermal life

    by Yue Xu, Tejaswi Soori, Qian Zhang, J.Y. Zhu, J. Keith Nelson, Liangbing Hu, Vaibhav Bahadur, Robert Hebner


  • Open Access

    Electric Field Distributions in Laser Drilled Voids of Polymeric Test Samples

    by Yue Xu, Kent Davey, Wenping Zhao, Robert E. Hebner, Miad Yazdani

    Future electric transportation systems are expected to employ electrical power trains with higher operating voltage and power density. Therefore, compact and reliable insulation systems are important, since they influence the system integration, thermal resistance, and parasitic inductance. In this paper, experiments and analysis show behavior which are not observed with mechanically produced holes before. A boundary element analysis of the electric field distribution around the voids reveals why these new observations are identified in voids with relatively sharp corners. The electric field computation shows conditions under which there is electric field enhancement at the void periphery. This drives the partial discharge (PD) activity and the erosion growth away from the center of the voids.


  • Open Access

    Modeling the impact of high thermal conductivity paper on the performance and life of power transformers

    by S. Bilyaz, A. Bhati, M. Hamalian, K. Maynor, T. Soori, A. Gattozzi, C. Penney, D. Weeks, Y. Xu, L. Hu, et al.


  • A Novel High Insulation 100 kW Medium Frequency Transformer

    by Zhicheng Guo, Sanjay Rajendran, Jagadeesh Tangudu, Yasmin Khakpour, Stephen Taylor, Lei Xing, Yue Xu, Xianyong Feng, Alex Q. Huang

    High voltage insulation and thermal management are the two major challenges in a high-power medium frequency transformer (MFT) design. This letter proposes novel insulation and cooling structure with potted windings in a 100 kW MFT with two FINEMET FT-3TL magnetic cores and parallel-concentric winding structure. For the first time, a three-dimensional printed bobbin with heatsink fins is demonstrated. The 100 kW MFT achieves a power density of 10.6 kW/L and a partial discharge inception voltage of 20 kV peak. The MFT is applied in a dual active bridge based medium voltage solid state transformer, achieving a peak efficiency of 98.2% at 40 kW and 97.5% at 100 kW. The MFT itself has a 99.735% efficiency with superior thermal performance at 100 kW output power.


  • A Compact High-Power Single-Turn Inductor for 6 kV SiC-based Power Electronics Building Blocks

    by He Song, Jun Wang, Yue Xu, Joshua Stewart, Slavko Mocevic, Igor Cvetkovic, Rolando Burgos, Dushan Boroyevich

    Based on our previous work, this paper presents the follow-up design and testing of a single-turn magnetic-core inductor for 6 kV power electronics building blocks (PEBBs) using 10 kV SiC MOSFET modules. The specifications of the inductor were derived from the switching-cycle control (SCC) principle. The single-turn magnetic core inductor with shielded solid insulation has been concluded to be the most suitable solution based on our prior work. The shielding layer facilitates the insulation design, but it has some side-effects such as shileding losses, shield termination and induced displacement current. Beyond our previous work, a double-layer termination structure is proposed to shrink the size of the termination structure and minimize the electric field strength in air, and quantitative study is conducted regarding the dimensions and permittivity. The displacement current is investigated and recommendations are provided. Two fabrication process methods for winding insulation are investigated and compared, and the one discussed in this paper is chosen to facilitate the mass production for modular multilevel converters (MMC) application. The proposed fabrication process gives 7.34 kV PDIV which meets the insulation requirement. The converter-level tests confirm the effectiveness of the grounding current reduction method.


  • High Power Density Medium-Voltage Converter Integration via Electric Field Management

    by Yue Xu, Joshua Stewart, He Song, Li Cheng, Igor Cvetkovic, Rolando Burgos, Dushan Boroyevich

    SiC-based converters can achieve much higher voltage rating and power density than Si- based ones. Therefore, electric field (E-field) intensity inside SiC-based converters can become significantly high and initial partial discharges, especially along the exposed metal or insulator to air interfaces. To achieve discharge free by design, E-field intensity and insulation space in air need be carefully analyzed and well managed. Due to the complicated structure of power converters, sharp edges and corners cannot be fully avoided. Thus, E-field management should be considered for such critical regions, in order to make the E-field distribution more uniform and shrink the insulation size. In this article, by using the self-made medium-voltage power electronics building block (PEBB) as an example, critical regions for insulation design are identified. Then focusing on the region between the cooling system and the heatsink, the influence on E-field distribution with different guard rings’ shape, size, and location, is demonstrated. Following the simulation analysis and design comparison, six guard rings are fabricated and experimentally verified. Therefore, a methodology about E-field management for power converters is provided in this article, including critical region analysis, design comparison, guard ring fabrication, and experimental verification.


  • Insulation Design of Wireless Auxiliary Power Supply for Medium Voltage Converters

    by Keyao Sun, Yue Xu, Jun Wang, Rolando Burgos, Dushan Boroyevich

    Auxiliary power supply (APS) that provides reliable power and voltage for gate drivers, controllers, and sensors is a critical component in medium voltage (MV) converter. Compared to being fed from the power-cell dc-link, APS fed from an external earthed system has its own benefits. However, with the power-cell number scaled up, the insulation design of the externally-fed APS becomes a significant challenge. Partial discharge (PD) can cause accumulative irreversible damages of insulation, which further lead to auxiliary power circuit fault and eventually cascaded failures of the whole converter system. Therefore, a PD-free APS system ensuring the reliability of MV converter is required. Among different technologies for building APS, wireless power transfer (WPT) becomes an attractive method because of its mechanical design flexibility and inborn insulation capability. In this paper, in order to design a PD-free WPT converter, insulation design criterion and electric field distribution under different coil geometries are analyzed, compared, and tested. Subsequently, a comprehensive insulation design including the influence of ferrite shielding layer is shown. Finally, an optimized WPT prototype with 120 W output power, 92.78% full-power efficiency, 2.76pF isolation capacitance, and 27 kV insulation capability is validated experimentally.