Manjunath Machnoor
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Manjunath Machnoor has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Gianluca Lazzi
University of Southern California
3 shared publications - Pragya Kosta
Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT, USA
2 shared publications - Constantine Sideris
Stanford University, Stanford, CA, USA
1 shared publication - Ege Iseri
Department of Biomedical Engineering and the Institute for Technology and Medical Systems, University of Southern California, USA
1 shared publication Erik Saturnino Gamez Rodriguez
1 shared publicationGianluca Lazzi
1 shared publication
Latest Publications
- 19 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (1) , 322-332
A Negative Impedance Converter Design to Enhance Capacitive Conduction Through a Neurostimulator Electrode Interface
Objective: With the growing interest in electric field-induced neuromodulation for clinical applications, optimizing circuitry and stimulation parameters is crucial for effective therapy. Studies have shown successful neuroregeneration, neuroprotection, and neuronal activation in vitro when electric fields exceed a certain threshold. However, clinical translation remains challenging, as stimulation amplitudes are often constrained by patient tolerance. Strategies that enhance charge delivery per phase within safety limits can improve the efficacy of these techniques. Approach: This paper presents a method to reduce the electrode-tissue interface time constant by incorporating a negative resistance circuit to lower the series resistance and an RC circuit to reduce the equivalent capacitance in a Thevenin model of the interface. By targeting the capacitive conduction phase with higher amplitudes, a voltage-controlled stimulator can deliver greater charge while remaining within tolerance limits. The proposed circuit models are validated in vivo by assessing the stimulation tolerance of rats at the optic nerve. Main Results: The proposed circuits connected in series with a two-electrode stimulator effectively reduced the time constant of the current waveform, shifting the magnitude response toward higher frequencies in Bode analysis. In vivo experiments confirmed that animals tolerated, on average, 20% greater charge injection within the first 200 $\mu$s of a rectangular pulse—the interval where capacitive charge transfer dominates over faradaic processes. Significance: Enhancing voltage-controlled neurostimulators with external circuits is a promising approach to overcoming amplitude limitations in clinical neurostimulation. As electrotherapy requires a minimum electric field amplitude for efficacy, increasing patient tolerance can improve treatment success rates.
- 19 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (1) , 322-332
A Negative Impedance Converter Design to Enhance Capacitive Conduction Through a Neurostimulator Electrode Interface
Objective: With the growing interest in electric field-induced neuromodulation for clinical applications, optimizing circuitry and stimulation parameters is crucial for effective therapy. Studies have shown successful neuroregeneration, neuroprotection, and neuronal activation in vitro when electric fields exceed a certain threshold. However, clinical translation remains challenging, as stimulation amplitudes are often constrained by patient tolerance. Strategies that enhance charge delivery per phase within safety limits can improve the efficacy of these techniques. Approach: This paper presents a method to reduce the electrode-tissue interface time constant by incorporating a negative resistance circuit to lower the series resistance and an RC circuit to reduce the equivalent capacitance in a Thevenin model of the interface. By targeting the capacitive conduction phase with higher amplitudes, a voltage-controlled stimulator can deliver greater charge while remaining within tolerance limits. The proposed circuit models are validated in vivo by assessing the stimulation tolerance of rats at the optic nerve. Main Results: The proposed circuits connected in series with a two-electrode stimulator effectively reduced the time constant of the current waveform, shifting the magnitude response toward higher frequencies in Bode analysis. In vivo experiments confirmed that animals tolerated, on average, 20% greater charge injection within the first 200 $\mu$s of a rectangular pulse—the interval where capacitive charge transfer dominates over faradaic processes. Significance: Enhancing voltage-controlled neurostimulators with external circuits is a promising approach to overcoming amplitude limitations in clinical neurostimulation. As electrotherapy requires a minimum electric field amplitude for efficacy, increasing patient tolerance can improve treatment success rates.
- 12 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 6 (4) , 574-579
Rectifier Design for Highly Loaded Inductive Wireless Power Transfer Systems for Biomedical Applications
Power transfer efficiency (PTE) and harmonics are crucial performance parameters of the resonant rectifier design for low/medium coupling inductive wireless power transfer (WPT) systems used in wireless biomedical implants. The performance of a resonant rectifier degrades under higher loading and lower coupling conditions as the voltage available to the rectifier at the output of the receiver coil becomes low. As the diode turn-on impedance increases, diodes turn on incompletely, leading to non-linearities that reduce rectifier efficiency and output voltage. This work proposes a new rectifier design to increase efficiency and reduce harmonics by decreasing the diode turn-on impedance compared to traditional rectifier designs, such as resonant Half Wave Rectifier (HWR). The proposed rectifier design offers individual paths for RF and rectification signals, which reduces the non-linear loading on the receiver coil and improves diode turn-on performance. Measurement and SPICE simulation results show efficiency enhancement of 50% and reduction of harmonics by 6 dB for the proposed rectifier compared to HWR.
- 12 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 6 (4) , 574-579
Rectifier Design for Highly Loaded Inductive Wireless Power Transfer Systems for Biomedical Applications
Power transfer efficiency (PTE) and harmonics are crucial performance parameters of the resonant rectifier design for low/medium coupling inductive wireless power transfer (WPT) systems used in wireless biomedical implants. The performance of a resonant rectifier degrades under higher loading and lower coupling conditions as the voltage available to the rectifier at the output of the receiver coil becomes low. As the diode turn-on impedance increases, diodes turn on incompletely, leading to non-linearities that reduce rectifier efficiency and output voltage. This work proposes a new rectifier design to increase efficiency and reduce harmonics by decreasing the diode turn-on impedance compared to traditional rectifier designs, such as resonant Half Wave Rectifier (HWR). The proposed rectifier design offers individual paths for RF and rectification signals, which reduces the non-linear loading on the receiver coil and improves diode turn-on performance. Measurement and SPICE simulation results show efficiency enhancement of 50% and reduction of harmonics by 6 dB for the proposed rectifier compared to HWR.
- 5 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 19 (10) , 1709-1713
Wireless Power Transfer: Types of Reflected Impedances and Maximum Power Transfer Theorem
In this work, different types of resonant reflected impedances (real, imaginary and negative) and conditions for their existence are introduced using power flow paths. The condition necessary to achieve maxima of power delivery at a high (>0.5) system efficiency is derived while maintaining a power factor of 0.85 or above. A 4-Coil WPT system operating at 4.7 MHz is implemented, to demonstrate that by controlling the different types of reflected impedances it is possible to overcome MPT induced constraints. The implemented example utilizes four non-overlapping coils of 35 mm radius; a maxima in power delivery is experimentally obtained while maintaining the efficiency and power factor above 0.5 and 0.85, respectively.
- 5 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 19 (10) , 1709-1713
Wireless Power Transfer: Types of Reflected Impedances and Maximum Power Transfer Theorem
In this work, different types of resonant reflected impedances (real, imaginary and negative) and conditions for their existence are introduced using power flow paths. The condition necessary to achieve maxima of power delivery at a high (>0.5) system efficiency is derived while maintaining a power factor of 0.85 or above. A 4-Coil WPT system operating at 4.7 MHz is implemented, to demonstrate that by controlling the different types of reflected impedances it is possible to overcome MPT induced constraints. The implemented example utilizes four non-overlapping coils of 35 mm radius; a maxima in power delivery is experimentally obtained while maintaining the efficiency and power factor above 0.5 and 0.85, respectively.
- 28 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 19 (4) , 690-694
Wireless Telemetry System With Independent Power and Data Frequency Resonance
Wireless power and data transmission systems are important components in bio-electronics. Achieving resonance at the data transmission frequency without negatively impacting the efficiency at the power transmission frequency may enhance data transmission capability. In this work, a new system referred to as Tuned Inductor Four Capacitor (TL4C) is proposed to achieve resonance at the data transmission frequency of a wireless telemetry system without significantly affecting the efficiency at the power transmit frequency; as a result, this leads to increased voltage and current gains and reduced reflections at the data transmit frequency when compared to an equivalent, traditional, two-coil system. The performance of the proposed design is demonstrated through a system implementation characterized by a transmit coil of 40 mm diameter and receive coil of 15 mm diameter, with a distance between them varied from 17 mm to 40 mm. This system is experimentally compared with the equivalent two-coil system that has the same transmit and receive coil footprint and layout but conventional transmitter matching circuitry: results show that, at the data telemetry frequency, there is no reflection, the voltage gain is 60% higher than that of the traditional two coil system, while the current gain is 250% higher.
- 28 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 19 (4) , 690-694
Wireless Telemetry System With Independent Power and Data Frequency Resonance
Wireless power and data transmission systems are important components in bio-electronics. Achieving resonance at the data transmission frequency without negatively impacting the efficiency at the power transmission frequency may enhance data transmission capability. In this work, a new system referred to as Tuned Inductor Four Capacitor (TL4C) is proposed to achieve resonance at the data transmission frequency of a wireless telemetry system without significantly affecting the efficiency at the power transmit frequency; as a result, this leads to increased voltage and current gains and reduced reflections at the data transmit frequency when compared to an equivalent, traditional, two-coil system. The performance of the proposed design is demonstrated through a system implementation characterized by a transmit coil of 40 mm diameter and receive coil of 15 mm diameter, with a distance between them varied from 17 mm to 40 mm. This system is experimentally compared with the equivalent two-coil system that has the same transmit and receive coil footprint and layout but conventional transmitter matching circuitry: results show that, at the data telemetry frequency, there is no reflection, the voltage gain is 60% higher than that of the traditional two coil system, while the current gain is 250% higher.
- 28 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 67 (8) , 5012-5024
Analysis and Design of a 3-Coil Wireless Power Transmission System for Biomedical Applications
- 28 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 67 (8) , 5012-5024
Analysis and Design of a 3-Coil Wireless Power Transmission System for Biomedical Applications