DMDaisuke Morimoto-Ishikawa

Daisuke Morimoto-Ishikawa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Daisuke Morimoto-Ishikawa has a total of 58 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Quantitative Evaluation of Noncontrast Magnetic Resonance Enterography for Active Inflammation in Crohn Disease Using Native T1 and T2 Mapping

    by Daisuke Morimoto-Ishikawa, Tomoko Hyodo, Yoriaki Komeda, Hiroyuki Rt Fukushima, Makoto Rt Itoh, Yu Ueda, Masatoshi Kudo, Shigeyoshi Saito, Kazunari Ishii

    Purpose: The aim of this study was to investigate the utility of native T1 and T2 mapping in the bowel to evaluate disease activity in Crohn disease (CD) using endoscopy as the reference standard. Methods: This was a prospective study. Magnetic resonance imaging was performed by using a 1.5-T Philips scanner. We used a modified look-locker inversion recovery and a multiecho gradient-spin-echo sequences for single breath-hold native T1 and T2 maps, respectively, for the short-axis image of the intestine, and the measurement at the most severe site was compared with partial Simple Endoscopic Score for Crohn's Disease (pSES-CD, assessed by an expert endoscopist). A pSES-CD ≥ 4 indicated active disease. Statistical analyses were performed using the Student t test, Spearman correlation, and receiver operating characteristic curve analysis. Results: A total of 27 patients (mean age ± standard deviation, 37 ± 18 years; 20 men, 7 women) were included in this study. The native T1 value of active disease was significantly higher than that of inactive disease (1170.8 ± 100.5 milliseconds vs 924.5 ± 95.3 milliseconds; P = 0.018), but the T2 value was not significantly different between active and inactive disease (76.1 ± 7.8 milliseconds vs 69.3 ± 10.9 milliseconds; P = 0.424). A good correlation was found between native T1 value and pSES-CD (ρ = 0.71; P < 0.001) but not between T2 value and pSES-CD (ρ = 0.06; P = 0.790). The area under the receiver operating characteristic curve for differentiating the disease activity was 0.96 (95% confidence interval [CI]: 0.90–1.00) for T1 values and 0.68 (95% confidence interval: 0.41–0.96) for T2 values. Conclusions: Native T1 mapping could be potentially used as a noninvasive method to differentiate disease activity in patients with CD and may be superior to T2 mapping for this purpose.


  • Open Access

    Organ-Specific Positron Emission Tomography Scanners for Breast Imaging: Comparison between the Performances of Prior and Novel Models

    by Yoko Satoh, Kohei Hanaoka, Chihiro Ikegawa, Masamichi Imai, Shota Watanabe, Daisuke Morimoto-Ishikawa, Hiroshi Onishi, Toshikazu Ito, Yoshifumi Komoike, Kazunari Ishii

    The performances of photomultiplier tube (PMT)-based dedicated breast positron emission tomography (PET) and silicon photomultiplier tube (SiPM)-based time-of-flight (TOF) PET, which is applicable not only to breast imaging but also to head imaging, were compared using a phantom study. A cylindrical phantom containing four spheres (3–10 mm in diameter) filled with 18F-FDG at two signal-to-background ratios (SBRs), 4:1 and 8:1, was scanned. The phantom images, which were reconstructed using three-dimensional list-mode dynamic row-action maximum likelihood algorithm with various β-values and post-smoothing filters, were visually and quantitatively compared. Visual evaluation showed that the 3 mm sphere was more clearly visualized with higher β and smaller post-filters, while the background was noisier; SiPM-based TOF-PET was superior to PMT-based dbPET in sharpness, smoothness, and detectability, although the background was noisier at the SBR of 8:1. Quantitative evaluation revealed that the detection index (DI) and recovery coefficient (CRC) of SiPM-based TOF-PET images were higher than those of PMT-based PET images, despite a higher background coefficient of variation (CVBG). The two organ-specific PET systems showed that a 3 mm lesion in the breast could be visualized at the center of the detector, and there was less noise in the SiPM-based TOF-PET image.


  • Open Access

    Evaluation of the Performance of a High-Resolution Time-of-Flight PET System Dedicated to the Head and Breast according to NEMA NU 2-2012 Standard

    by Daisuke Morimoto-Ishikawa, Kohei Hanaoka, Shota Watanabe, Takahiro Yamada, Yoshiyuki Yamakawa, Suzuka Minagawa, Shiho Takenouchi, Atsushi Ohtani, Tetsuro Mizuta, Hayato Kaida, et al.

    Background: This study evaluated the physical performance of a positron emission tomography (PET) system dedicated to the head and breast according to the National Electrical Manufacturers Association (NEMA) NU2-2012 standard. Methods: The spatial resolution, sensitivity, scatter fraction, count rate characteristics, corrections for count losses and randoms, and image quality of the system were determined. All measurements were performed according to the NEMA NU2-2012 acquisition protocols, but image quality was assessed using a brain-sized phantom. Furthermore, scans of the three-dimensional (3D) Hoffmann brain phantom and mini-Derenzo phantom were acquired to allow visual evaluation of the imaging performance for small structures.Results: The tangential, radial, and axial full-width at half maximum (FWHM) at a 10-mm offset in half the axial field of view were measured as 2.3, 2.5, and 2.9 mm, respectively. The average system sensitivity at the center of the field of view and at a 10-cm radial offset were 7.18 and 8.65 cps/kBq, respectively. The peak noise-equivalent counting rate was 35.2 kcps at 4.8 kBq/ml. The corresponding scatter fraction at the peak noise-equivalent counting rate was 46.8%. The peak true rate and scatter fraction at 8.6 kBq/ml were 127.8 kcps and 54.3%, respectively. The percent contrast value for a 10-mm sphere was approximately 50%. On the 3D Hoffman brain phantom image, the structures of the thin layers composing the phantom were visualized on the sagittal and coronal images. On the mini-Derenzo phantom, each of the 1.6-mm rods were clearly visualized. Conclusion: Taken together, these results indicate that the head and breast-dedicated PET system has high-resolution and is well suited for clinical PET imaging.


  • Open Access

    Metabolites Alterations and Liver Injury in Hepatic Encephalopathy Models Evaluated by Use of 7T-MRI

    by Shigeyoshi Saito, Narumi Arihara, Reika Sawaya, Daisuke Morimoto-Ishikawa, Junpei Ueda

    This study is to observe a thioacetamide (TAA) administered Hepatic encephalopathy (HE) model rats at three and ten days after TAA administration using liver MRI and brain MR Spectroscopy (MRS) by use of 7T-MRI. Forty-two Wistar rats (control group, n = 14) were intraperitoneally administered at 300 mg/kg (low-dose group, n = 14) or 400 mg/kg (high-dose group, n = 14) doses of TAA for induced of HE. At three days after TAA administration, glutamine (Gln) measured by MRS in high-dose and low-dose TAA groups showed significant increases in comparison to those of the control group (p < 0.05). Other metabolites measured by MRS showed no significant changes. Liver T1ρ and T2 relaxation times significantly increased three days after TAA injection compared to pre-injection. There was a correlation between Gln levels in the brain and the relaxation time of the liver. Furthermore, Gln levels and relaxation time changed depending on the TAA dose. The Gln concentration in the brain increased with the deterioration of liver function, as inferred from the prolonged relaxation time of the liver. The prolonged relaxation time of the liver corresponded with the level of Gln in the brain. Gln concentration for the alterations of brain metabolites and T1ρ relaxation time for the assessment of liver damage are useful markers for inter-organ association analysis in the HE model.


  • Comparison between gradient and spin-echo (GRASE) and compressed sensing sequences for single breath-hold three-dimensional magnetic resonance cholangiopancreatography in patients with T1 hyperintense bile

    by Daisuke Morimoto-Ishikawa, Tomoko Hyodo, Mamoru Takenaka, Yuko Matsukubo, Isao Numoto, Makoto Itoh, Masato Ohmi, Ken Kamata, Yu Ueda, Miyuki Wakana, et al.


  • Navigator-triggered and breath-hold 3D MRCP using compressed sensing: image quality and method selection factor assessment

    by Daisuke Morimoto, Tomoko Hyodo, Ken Kamata, Tomoya Kadoba, Makoto Itoh, Hiroyuki Fukushima, Yasutaka Chiba, Mamoru Takenaka, Tomohiro Mochizuki, Yu Ueda, et al.

    Purpose To examine whether MRCP using a combination of compressed sensing and sensitivity encoding with navigator-triggered and breath-hold techniques (NT C-SENSE and BH C-SENSE, respectively) have comparable image quality to that of navigator-triggered MRCP using only sensitivity encoding (NT SENSE) at 1.5-T. Methods Fifty-one participants were enrolled in this prospective study between July and October 2018 and underwent the three 3D MRCP sequences each. The acquisition time and relative duct-to-periductal contrast ratios (RC values) of each bile duct segment were obtained. Visualization of the bile and main pancreatic ducts, background suppression, artifacts, and overall image quality were scored on 5-point scales. Mean and median differences in RC values and qualitative scores of NT C-SENSE and BH C-SENSE relative to NT SENSE were calculated with 95% confidence intervals (CIs). Results Acquisition time of NT SENSE, NT C-SENSE, and BH C-SENSE were 348, 143 (mean for both), and 18 s (for all participants), respectively. The RC value of each bile duct segment was inferior, but the lower limits of the 95% CIs of the mean differences were ≥ − 0.10, for both NT C-SENSE and BH C-SENSE. The visualization score of the intrahepatic duct in BH C-SENSE was inferior to that in NT SENSE (lower 95% CI limit, − 1.5). In both NT C-SENSE and BH C-SENSE, the 95% CIs of the median differences in the other qualitative scores were from − 1.0 to 0.0. Conclusion NT C-SENSE and BH C-SENSE have comparable image quality to NT SENSE at 1.5-T.


  • Dual‐frequency MR elastography to differentiate between inflammation and fibrosis of the liver: Comparison with histopathology

    by Keitaro Sofue, Minori Onoda, Masakatsu Tsurusaki, Daisuke Morimoto, Norihisa Yada, Masatoshi Kudo, Takamichi Murakami

    Background Differentiation between inflammation and fibrosis is an important clinical distinction in patients with chronic liver disease, which has been difficult so far with MR elastography. Purpose To investigate whether dual‐frequency MR elastography can estimate necroinflammation of the liver and improve diagnostic performance for the staging of liver fibrosis. Study Type Retrospective. Subjects In all, 30 patients (14 males, 16 females) with chronic liver disease. Field Strength/Sequence 5T/dual‐frequency MR elastography at 60‐Hz and 80‐Hz vibration frequencies. Assessment Necroinflammation activity and fibrosis were assessed using the METAVIR scoring system. Stiffness values at 60‐Hz (G60‐Hz) and 80‐Hz (G80‐Hz) were obtained with an MR elastogram. The difference value between G80‐Hz and G60‐Hz (ΔG) was calculated. Four values (G60‐Hz, G80‐Hz, G60‐Hz – ΔG, and G80‐Hz + ΔG) were generated to estimate necroinflammation and fibrosis. Statistical Tests The ΔG were correlated with necroinflammation activity grade and fibrosis stage using Spearman's rank correlation. Diagnostic performance of the four values for necroinflammation activity grade and fibrous stage was assessed by using area under the receiver operating characteristic curve (AUC). Results The mean value of G80‐Hz (6.23 ± 3.67 kPa) was significantly higher than that of G60‐Hz (5.27 ± 3.14 kPa) (P < 0.0001). The ΔG demonstrated a strong correlation with necroinflammation grade (ρ = 0.625, P < 0.001) and no correlation with fibrosis stage (ρ = 0.306, P = 0.113). The AUC of the G80‐Hz and G80‐Hz + ΔG showed higher accuracy for necroinflammation, and optimal cutoff values yielded better discrimination of ≥A1, ≥A2, and = A3. The AUC demonstrated that all the generated values had high diagnostic performance (≥0.87 for all) for fibrosis. Data Conclusion Dual‐frequency MR elastography shows potential in estimating necroinflammation of the liver and may improve diagnostic performance for staging liver fibrosis. Level of Evidence: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019.


  • F18-FDG PET-CT analyses of small peripheral adenocarcinoma of the lung

    by Yoshiyuki Takahashi, Shodayu Takashima, Shinichiro Watanabe, Yasuhiko Tomita, Tomoaki Hakucho, Chie Miyake, Daisuke Morimoto, Takuya Hosoki, Katsuyuki Nakanishi, Masahiko Higashiyama

    Background: Radiological discrimination of histologic subtypes of small peripheral adenocarcinoma of the lung is clinically important. Although there are many articles in which CT findings were used for this purpose, there are only a few reports on the capability of FDG PET-CT findings for histologic classification of this tumor. Purpose: To investigate the correlation between visual assessment or maximum standard uptake values (SUVmax) on F18-FDG PET-CT and histology grading of small peripheral adenocarcinoma of the lung. Material and Methods: Proportions of positive PET-CT diagnoses and SUVmax were retrospectively reviewed on 96 solitary pulmonary nodules of ≤2 cm in 90 consecutive patients. Tumors were classified into four groups according to Noguchi's classification (group 1 [ n = 10], atypical adenomatous hyperplasia and type A tumors; group 2 [ n = 12], type B tumors; group 3 [ n = 42], type C tumors; group 4 [ n = 32], types D, E, and F tumors). Proportions of positive PET-CT diagnoses and mean SUVmax of lesions among four groups were compared using trend tests to examine if there is a significant linear correlation with the progression of the histology grading of tumors. Then, an optimal threshold of SUVmax was proposed to best discriminate tumors of poor (groups 3 and 4) from good (groups 1 and 2) prognosis. Results: There was a significant linear trend for both visual assessment ( P < 0.01) and SUVmax ( P < 0.01). A SUVmax of 0.42 showed the highest accuracy of 84% with 95% sensitivity and 50% specificity for predicting tumors of poor prognosis. A SUVmax of 2.05 showed 100% specificity with 49% sensitivity, and 60% accuracy. Positive visual diagnoses showed accuracy of 83% with 90% sensitivity and 59% specificity. Conclusion: Visual assessment and SUVmax on PET-CT correlated well with the histology grading of small peripheral adenocarcinoma of the lung.