Influence of Partial Arc on Electric Field Distribution of Insulator Strings for Electrified Railway Catenary
Open Access
Abstract
The occurrence of a partial arc can affect insulation properties of the insulator by different types of flashover. In order to investigate the influence of a partial arc on electric field distribution along the catenary insulator string, a three-dimensional model of the cap-pin insulator string with partial arc was established in this paper. The electric field distribution along the insulator string when the arc extended on the insulator surface and bridged sheds was investigated based on the electric field analysis using the finite element method. The results showed that the occurrence of a partial arc caused obvious distortion of the electric field, which was a two-dimensional axis symmetrical field before arcing to a three-dimensional field. In the case of arc extension, the sudden rise of field intensity was mostly at the rib and the shed edge, which had the local maximum field intensity. The rib and the shed edge played a certain hindrance role in the extension of the arc. The main reason for promoting the development of the arc can be attributed to thermal ionization. In the case of arc bridge sheds, the highest field intensity appeared at the edge of the last bridged shed. As the number of sheds arc-bridged increased, the maximum field intensity also increased. As the arc length increased, the electric field intensity of the arc head also increased, which resulted in an accelerated arc development. The main factor to promote the development of the arc can be attributed to electrical breakdown. The measures to hinder the rapid development of partial arcs were proposed.Keywords
Funding Information
- National Natural Science Foundation of China (51867013, 51767014, 51567014)
This publication has 10 references indexed in Scilit:
- Wet Snow Flashover Characteristics of 500-kV AC Insulator Strings with Different ArrangementsApplied Sciences, 2019
- Study on the flashover characteristics of bird droppings along 110kV composite insulator2018
- Ion Migration in the Process of Water Freezing under Alternating Electric Field and Its Impact on Insulator FlashoverEnergies, 2017
- Optimal design of corona ring on HV composite insulator using PSO approach with dynamic population sizeIEEE Transactions on Dielectrics and Electrical Insulation, 2016
- Flashover performance of ice-covered post insulators with booster sheds using experiments and partial arc modelingIEEE Transactions on Dielectrics and Electrical Insulation, 2016
- Investigations on AC pollution flashover performance of insulator string under different non‐uniform pollution conditionsIET Generation, Transmission & Distribution, 2016
- Electrical performance of composite insulators under icing conditionsIEEE Transactions on Dielectrics and Electrical Insulation, 2014
- Modeling flashover of AC outdoor insulators under contaminated conditions with dry band formation and arcingIEEE Transactions on Dielectrics and Electrical Insulation, 2012
- Electric field calculation for an axially-symmetric insulator with surface contaminationIEEE Transactions on Dielectrics and Electrical Insulation, 1994
- Arc propagation along an electrolyte surfaceProceedings of the Institution of Electrical Engineers, 1971