Georgii Gnedash
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Georgii Gnedash has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Raisa Navrodska
Institute of Engineering Thermophysics of the National Academy of Sciences of Ukraine
14 shared publications - Natalia Mikhailivna Fialko
Institute of Engineering Thermophysics
13 shared publications - Svitlana Shevchuk
Institute of Engineering Thermophysics of the National Academy of Sciences of Ukraine
13 shared publications - Georgii Presich
Інститут технічної теплофізики НАН України, м. Київ
4 shared publications - G. O. Sbrodova
Institute of Engineering Thermophysics of National Academy of Sciences of Ukraine
2 shared publications - Alla Stepanova
Київський національний університет імені Тараса Шевченка
1 shared publication
Latest Publications
- 27 October 2026
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 5,p. 113-121
Increasing fuel efficiency of waste incombustion boiler plants
Purpose. The goal is to increasing the thermal efficiency of a water heating boiler burning solid household waste or fuels made from it. Methodology. Known and developed by the authors, methods for thermal calculation of heat exchangers were used. Findings. The modern heat-recovery technology based on the use of a complex system has been proposed for the useful use of waste heat from combustion products of household waste incineration plants and fuels based on it. This system is designed to heat combustion air and heating network water in the corresponding modular heat exchangers-heat recovery units. Original technical solutions for these heat-recovery units have been developed with the possibility of operation on dusty gas flows. Calculation studies have been carried out on the effectiveness of the use of the specified system. The patterns of changes in the main characteristics of the heat-recovery system have been determined, namely: its heat productivity, final temperature levels of the used heat-transfer agents and the volumes of condensate formed during deep cooling of waste gases. The level of flue gas temperature reduction in the entire heat-recovery system is 126.9‒197.1 °C. Therefore, the use of the proposed heat-recovery system and the equipment used is an effective measure to significantly increase the efficiency of incineration of solid household waste and fuels based on it. Originality. First proposed, a complex heat-recovery system designed to heat combustion air and heating water has been proposed for a waste incineration boiler, and its energy efficiency has been investigated. Practical value. The obtained research results will be used to increase the efficiency of incineration of solid household waste and fuels from it in relevant installations.
- 27 October 2026
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 5,p. 113-121
Increasing fuel efficiency of waste incombustion boiler plants
Purpose. The goal is to increasing the thermal efficiency of a water heating boiler burning solid household waste or fuels made from it. Methodology. Known and developed by the authors, methods for thermal calculation of heat exchangers were used. Findings. The modern heat-recovery technology based on the use of a complex system has been proposed for the useful use of waste heat from combustion products of household waste incineration plants and fuels based on it. This system is designed to heat combustion air and heating network water in the corresponding modular heat exchangers-heat recovery units. Original technical solutions for these heat-recovery units have been developed with the possibility of operation on dusty gas flows. Calculation studies have been carried out on the effectiveness of the use of the specified system. The patterns of changes in the main characteristics of the heat-recovery system have been determined, namely: its heat productivity, final temperature levels of the used heat-transfer agents and the volumes of condensate formed during deep cooling of waste gases. The level of flue gas temperature reduction in the entire heat-recovery system is 126.9‒197.1 °C. Therefore, the use of the proposed heat-recovery system and the equipment used is an effective measure to significantly increase the efficiency of incineration of solid household waste and fuels based on it. Originality. First proposed, a complex heat-recovery system designed to heat combustion air and heating water has been proposed for a waste incineration boiler, and its energy efficiency has been investigated. Practical value. The obtained research results will be used to increase the efficiency of incineration of solid household waste and fuels from it in relevant installations.
- Open Access
- 5 February 2026
- Published by Institute of Engineering Thermophysics of NAS of Ukraine in Thermophysics and Thermal Power Engineering
- Vol. 48 (1) , 75-84
EFFICIENCY OF NEW COMPLEX HEAT-RECOVERY SYSTEMS OF HEATING BOILER UNITS
The work is devoted to research on the development and scientific and technical justification of a new heat-recovery system designed to heat return heat-network water and combustion air. At using a traditional system of similar purpose, the heating transfer agent in heat exchangers-heat recovery units is the boiler waste gases. In this case, the water-heating heat-recovery exchanger is installed first in the gas flow, and the air-heating heat-recovery exchanger is installed second. The use of such a scheme for combining heat-recovery exchangers has certain disadvantages. Thus, deep cooling of waste gases with the formation of condensate during the cold period of the heating season is implemented in an air heater, which requires expensive corrosion-resistant materials for its construction. In addition, gas-heating air heaters, as is known, are very large in size, which complicates their placement in the usually cramped conditions of boiler houses. The aim of the work is to develop small-sized and material-intensive complex heat-recovery units for gas-fired eco-efficient heating boilers and to study their efficiency. The main tasks of the work were to develop a new complex heat-recovery system for a heating boiler using a water-heating air heater, devoid of the above-mentioned disadvantages, and to study its efficiency indicators. Known methods of thermal calculation of heating installations and the results of our own research on heat exchange during deep cooling of its metal capacity and compactness under the conditions of operation of eco-efficient boilers with waste gas recirculation were used. The material capacity m and compactness v of the system and its elements were estimated as the ratio of mass or volume to the amount of recovered power of waste gases of boiler installations. The results of the research of the main thermal indicators of the developed system are presented. The patterns of changes in the studied indicators during the heating period are established. The results obtained are compared with those corresponding to the traditional complex heat-recovery system equipped with a gas-heating air heater. It is shown that the use of the proposed system ensures: reliable operation of the air supply channels of the boiler plant due to heating of the combustion air in the water-heating heater of air to 32 ÷ 53 °С, which ensures the absence of condensate formation in these ducts, the resulting increase in the efficiency of the boiler plant of 1.5 ÷ 4.8 % due to the complex use of the recovered heat for heating the heating network water and combustion air, a decrease in the relative metal content of heat exchangers of heat-recovery unit and an increase in their compactness due to the developed heat-exchange surface, which is composed of a bundle of finned bimetallic pipes. In particular, the value of m of the water-heating air heater is 1,9 – 3,2 times smaller than the gas-heating analogue, which ensures a reduction in the total relative metal capacity of the proposed heat-recovery system by 1.4 ÷ 1.7 times, depending on the boiler operating mode and the proportion of waste gas recirculation. Accordingly, the value of the compactness index v is 2.0 ÷ 2.8 times lower for the air heater and 1.6 ÷ 1.9 times lower for the system as a whole.
- 5 February 2026
- Published by Institute of Engineering Thermophysics of NAS of Ukraine in Thermophysics and Thermal Power Engineering
- Vol. 48 (1) , 75-84
Open AccessEFFICIENCY OF NEW COMPLEX HEAT-RECOVERY SYSTEMS OF HEATING BOILER UNITS
The work is devoted to research on the development and scientific and technical justification of a new heat-recovery system designed to heat return heat-network water and combustion air. At using a traditional system of similar purpose, the heating transfer agent in heat exchangers-heat recovery units is the boiler waste gases. In this case, the water-heating heat-recovery exchanger is installed first in the gas flow, and the air-heating heat-recovery exchanger is installed second. The use of such a scheme for combining heat-recovery exchangers has certain disadvantages. Thus, deep cooling of waste gases with the formation of condensate during the cold period of the heating season is implemented in an air heater, which requires expensive corrosion-resistant materials for its construction. In addition, gas-heating air heaters, as is known, are very large in size, which complicates their placement in the usually cramped conditions of boiler houses. The aim of the work is to develop small-sized and material-intensive complex heat-recovery units for gas-fired eco-efficient heating boilers and to study their efficiency. The main tasks of the work were to develop a new complex heat-recovery system for a heating boiler using a water-heating air heater, devoid of the above-mentioned disadvantages, and to study its efficiency indicators. Known methods of thermal calculation of heating installations and the results of our own research on heat exchange during deep cooling of its metal capacity and compactness under the conditions of operation of eco-efficient boilers with waste gas recirculation were used. The material capacity m and compactness v of the system and its elements were estimated as the ratio of mass or volume to the amount of recovered power of waste gases of boiler installations. The results of the research of the main thermal indicators of the developed system are presented. The patterns of changes in the studied indicators during the heating period are established. The results obtained are compared with those corresponding to the traditional complex heat-recovery system equipped with a gas-heating air heater. It is shown that the use of the proposed system ensures: reliable operation of the air supply channels of the boiler plant due to heating of the combustion air in the water-heating heater of air to 32 ÷ 53 °С, which ensures the absence of condensate formation in these ducts, the resulting increase in the efficiency of the boiler plant of 1.5 ÷ 4.8 % due to the complex use of the recovered heat for heating the heating network water and combustion air, a decrease in the relative metal content of heat exchangers of heat-recovery unit and an increase in their compactness due to the developed heat-exchange surface, which is composed of a bundle of finned bimetallic pipes. In particular, the value of m of the water-heating air heater is 1,9 – 3,2 times smaller than the gas-heating analogue, which ensures a reduction in the total relative metal capacity of the proposed heat-recovery system by 1.4 ÷ 1.7 times, depending on the boiler operating mode and the proportion of waste gas recirculation. Accordingly, the value of the compactness index v is 2.0 ÷ 2.8 times lower for the air heater and 1.6 ÷ 1.9 times lower for the system as a whole.
- 3 July 2025
- Published by Springer Nature
- p. 291-309
Increasing the Efficiency and Reliability of Heating Boiler Plants
- 3 July 2025
- Published by Springer Nature
- p. 291-309
Increasing the Efficiency and Reliability of Heating Boiler Plants
- 25 June 2025
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 3,p. 139-146
New complex heat-recovery systems of environmentally efficient boiler installations
Purpose. To establish the effectiveness of the proposed new technical solution of a small-sized and low-metal combined heat-recovery units for gas-consuming environmentally efficient heating boilers. Methodology. Known methods of thermal calculation of boiler plants and experimental research data obtained by the authors were used. Findings. A schematic circuit of a boiler plant with gas recirculation and a new complex heat-recovery system designed for heating such heat-transfer agents as heat network water and combustion air is proposed for the beneficial use of flue gas waste heat. Calculation studies on the main indicators of the thermal efficiency of the specified system and the heat-humidity condition in the air ducts of the boiler plant in different modes of its operation were performed. It is shown that the use of the proposed system ensures an increase in the efficiency of the boiler and the absence of condensation in the specified ducts. The indicators of the relative metal content of the considered heat-recovery exchangers were also obtained. A comparison of the calculated indicators with the corresponding indicators for the known heat-recovery system with heating of the specified heat-transfer agents was performed. The research results show that the new system with a water-heating air heater is characterized by a significantly lower relative metal capacity of this system equipped with a gas-heating air heater. Due to the use of a developed heating surface in it, the proposed water-heating air heater is low in metal consumption and highly compact, which is essential in its design and manufacture, as well as placement in the compressed conditions of boiler houses. Originality. For the first time, the effectiveness of a new complex heat-recovery system for heating boiler installations of increased environmental efficiency was proposed and investigated. Practical value. The obtained research results will be used to improve the environmental and thermal characteristics of boiler plants.
- 25 June 2025
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 3,p. 139-146
New complex heat-recovery systems of environmentally efficient boiler installations
Purpose. To establish the effectiveness of the proposed new technical solution of a small-sized and low-metal combined heat-recovery units for gas-consuming environmentally efficient heating boilers. Methodology. Known methods of thermal calculation of boiler plants and experimental research data obtained by the authors were used. Findings. A schematic circuit of a boiler plant with gas recirculation and a new complex heat-recovery system designed for heating such heat-transfer agents as heat network water and combustion air is proposed for the beneficial use of flue gas waste heat. Calculation studies on the main indicators of the thermal efficiency of the specified system and the heat-humidity condition in the air ducts of the boiler plant in different modes of its operation were performed. It is shown that the use of the proposed system ensures an increase in the efficiency of the boiler and the absence of condensation in the specified ducts. The indicators of the relative metal content of the considered heat-recovery exchangers were also obtained. A comparison of the calculated indicators with the corresponding indicators for the known heat-recovery system with heating of the specified heat-transfer agents was performed. The research results show that the new system with a water-heating air heater is characterized by a significantly lower relative metal capacity of this system equipped with a gas-heating air heater. Due to the use of a developed heating surface in it, the proposed water-heating air heater is low in metal consumption and highly compact, which is essential in its design and manufacture, as well as placement in the compressed conditions of boiler houses. Originality. For the first time, the effectiveness of a new complex heat-recovery system for heating boiler installations of increased environmental efficiency was proposed and investigated. Practical value. The obtained research results will be used to improve the environmental and thermal characteristics of boiler plants.
- 9 August 2023
- Published by Springer Nature
- p. 425-435
Anticorrosive Protection of Gas Exhaust Ducts of Boiler Plants with Heat-Recovery Systems
- 9 August 2023
- Published by Springer Nature
- p. 425-435
Anticorrosive Protection of Gas Exhaust Ducts of Boiler Plants with Heat-Recovery Systems
- 1 January 2022
- Published by Limited Liability Company Publishing Service Internauka (Publications) in International scientific journal "Internauka"
- No. 7(126)
PECULIARITYS OF THE USE OF FLUE GAS RECIRCULATION FOR BOILERS OF SMALL AND MEDIUM CAPACITY
The problems of using the method of flue gas recirculation into the combustion air for small-capacity boilers that are not equipped with air- heaters are described. An analysis of the thermal-humidity state of the gas-air mixture in different modes of a water-heating boiler with a heat output of 2 MW was carried out. The reasons for limiting the application of this method are determined and ways to solve problems are indicated.
- 1 January 2022
- Published by Limited Liability Company Publishing Service Internauka (Publications) in International scientific journal "Internauka"
- No. 7(126)
PECULIARITYS OF THE USE OF FLUE GAS RECIRCULATION FOR BOILERS OF SMALL AND MEDIUM CAPACITY
The problems of using the method of flue gas recirculation into the combustion air for small-capacity boilers that are not equipped with air- heaters are described. An analysis of the thermal-humidity state of the gas-air mixture in different modes of a water-heating boiler with a heat output of 2 MW was carried out. The reasons for limiting the application of this method are determined and ways to solve problems are indicated.
- 1 October 2021
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Municipal economy of cities
- Vol. 4 (164) , 24-30
USE AND DISPOSAL OF ACIDIC WATER CONDENSATE FROM GAS-FIRED BOILER UNITS
During operation in boiler units of modern condensing boilers or modernization of old-style boilers, water condensate is formed due to heat-recovery equipment in the mode of cooling exhaust-gases below the dew point of water vapor. At natural gas is burned in equipment, the range of values of the pH value of the condensate is within the range of 3 ÷ 6. In this connection, the problem arises of the useful use of this condensate or its safe drainage into the sewer network. At useful use, the resulting condensate can be used for the needs of the boiler units (for washing boilers, in chemical water-purification systems) or outside the boiler house (for laundries, greenhouses, swimming pools, etc.). In the case of condensate drainage into the city sewer network, as a rule, its preliminary decarbonization is required. This is a necessary environmental measure and operational standard to protect the sewer network and related equipment, including treatment facilities, from premature wear. Among the directions of condensate decarbonization known in Ukraine, the most common are: - decarbonization by degassing by the contact method, which consists in removing CO2 from the heated solution by blowing air in the nozzle layer (ceramic or plastic), through which condensate flows. Degassing occurs due to the instability of the H2CO3 compound, which, when heated, easily decomposes into H2O and CO2; - chemical decarbonization, by combining carbon dioxide in an insoluble compound with various reagents, which are added to the container using a dispenser; - decarbonization by passing the condensate through a granular filter containing calcium carbonate, such as marble chips or lime. Removal of carbonic acid from condensate during filtration in a layer of marble chips is seen as the simplest method of decarbonization of water condensate from those considered. On the basis of this method of decarbonization, the authors propose a technical solution for the developed neutralizer with a description of its design and operating principle. The paper presents the results of calculated studies of the volumes of formed condensate and an example of its safe use in the case of modernization of a gas-fired water-heating boiler with a nominal thermal power of 1 MW by a heat-recovery system with simple or complex use of heat. It is shown that when using modern heat-recovery technologies in gas-fired boiler houses, there are different circuit and technical solutions for possible useful use or safe evacuation of acidic condensate formed during the implementation of these technologies. In cases where it is advisable to neutralize this condensate, there are effective methods for its decarbonization and appropriate equipment.
- 1 October 2021
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Municipal economy of cities
- Vol. 4 (164) , 24-30
USE AND DISPOSAL OF ACIDIC WATER CONDENSATE FROM GAS-FIRED BOILER UNITS
During operation in boiler units of modern condensing boilers or modernization of old-style boilers, water condensate is formed due to heat-recovery equipment in the mode of cooling exhaust-gases below the dew point of water vapor. At natural gas is burned in equipment, the range of values of the pH value of the condensate is within the range of 3 ÷ 6. In this connection, the problem arises of the useful use of this condensate or its safe drainage into the sewer network. At useful use, the resulting condensate can be used for the needs of the boiler units (for washing boilers, in chemical water-purification systems) or outside the boiler house (for laundries, greenhouses, swimming pools, etc.). In the case of condensate drainage into the city sewer network, as a rule, its preliminary decarbonization is required. This is a necessary environmental measure and operational standard to protect the sewer network and related equipment, including treatment facilities, from premature wear. Among the directions of condensate decarbonization known in Ukraine, the most common are: - decarbonization by degassing by the contact method, which consists in removing CO2 from the heated solution by blowing air in the nozzle layer (ceramic or plastic), through which condensate flows. Degassing occurs due to the instability of the H2CO3 compound, which, when heated, easily decomposes into H2O and CO2; - chemical decarbonization, by combining carbon dioxide in an insoluble compound with various reagents, which are added to the container using a dispenser; - decarbonization by passing the condensate through a granular filter containing calcium carbonate, such as marble chips or lime. Removal of carbonic acid from condensate during filtration in a layer of marble chips is seen as the simplest method of decarbonization of water condensate from those considered. On the basis of this method of decarbonization, the authors propose a technical solution for the developed neutralizer with a description of its design and operating principle. The paper presents the results of calculated studies of the volumes of formed condensate and an example of its safe use in the case of modernization of a gas-fired water-heating boiler with a nominal thermal power of 1 MW by a heat-recovery system with simple or complex use of heat. It is shown that when using modern heat-recovery technologies in gas-fired boiler houses, there are different circuit and technical solutions for possible useful use or safe evacuation of acidic condensate formed during the implementation of these technologies. In cases where it is advisable to neutralize this condensate, there are effective methods for its decarbonization and appropriate equipment.
- 1 January 2020
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Science and innovation
- Vol. 16 (3) , 43-49
Study of Heat Recovery Systems for Heating and Moisturing Combustion Air of Boiler Units
- 1 January 2020
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Science and innovation
- Vol. 16 (3) , 43-49
Study of Heat Recovery Systems for Heating and Moisturing Combustion Air of Boiler Units
- 1 January 2020
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Nauka ta innovacii
- Vol. 16 (3) , 47-53
Study of Heat Recovery Systems for Heating and Moisturing Combustion Air of Boiler Units
- 1 January 2020
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Nauka ta innovacii
- Vol. 16 (3) , 47-53
Study of Heat Recovery Systems for Heating and Moisturing Combustion Air of Boiler Units
- 1 January 2020
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 2,p. 96-100
The environmental reliability of gas-fired boiler units by applying modern heat-recovery technologies
- 1 January 2020
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 2,p. 96-100
The environmental reliability of gas-fired boiler units by applying modern heat-recovery technologies