Ping Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ping Xu has a total of 99 co-authors. Here are the top co-authors by number of shared publications:
- Han-Ning Dai
Hefei National Research Center for Physical Sciences at the Microscale and School of Physical Sciences, University of Science and Technology of China 1 , Hefei 230026
9 shared publications - Xian-Qing Zhu
Hefei National Research Center for Physical Sciences at the Microscale and School of Physical Sciences, University of Science and Technology of China 1 , Hefei 230026
7 shared publications Xing-Yang Cui
University of Science and Technology of China
7 shared publications- Xiao Jiang
Hefei National Research Center for Physical Sciences at the Microscale and School of Physical Sciences, University of Science and Technology of China 1 , Hefei 230026
6 shared publications - Sheng-Kai Liao
University of Science and Technology of China
5 shared publications - De-Quan Kong
Hefei National Research Center for Physical Sciences at the Microscale and School of Physical Sciences, University of Science and Technology of China 1 , Hefei 230026
4 shared publications
Latest Publications
- 20 January 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (2) , 2632-2641
Characterization of the phase noise in a cavity-enhanced frequency doubler
In optical atomic clocks, the low phase noise of the frequency conversion is essential to maintain the high frequency stability and phase coherence of clock lasers. Higher power of interrogation lasers is required for future optical clocks. In this work, we present a cavity-enhanced frequency doubler based on second harmonic generation with an intra-cavity PPLN crystal. The frequency doubler is highly efficient in obtaining the strontium atomic clock laser from the fundamental laser at 1397 nm. We measure the excess phase noise introduced by the enhancement cavity. The cavity-enhanced frequency doubler introduces excess phase noise with a power spectral density that is nearly an order of magnitude lower than that of state-of-the-art interrogation lasers for offset frequencies between 0.001 Hz and 1 Hz. The modified Allan deviation of fractional frequency instability is 5.3×10 −18 at a 1-second averaging time under a homemade housing. It indicates that the doubler can be used to improve the short-term stability of strontium optical clocks with the best up-to-date ultra-stable lasers. Meanwhile, its high efficiency can match increasing interrogation laser power for further applications.
- 20 January 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (2) , 2632-2641
Characterization of the phase noise in a cavity-enhanced frequency doubler
In optical atomic clocks, the low phase noise of the frequency conversion is essential to maintain the high frequency stability and phase coherence of clock lasers. Higher power of interrogation lasers is required for future optical clocks. In this work, we present a cavity-enhanced frequency doubler based on second harmonic generation with an intra-cavity PPLN crystal. The frequency doubler is highly efficient in obtaining the strontium atomic clock laser from the fundamental laser at 1397 nm. We measure the excess phase noise introduced by the enhancement cavity. The cavity-enhanced frequency doubler introduces excess phase noise with a power spectral density that is nearly an order of magnitude lower than that of state-of-the-art interrogation lasers for offset frequencies between 0.001 Hz and 1 Hz. The modified Allan deviation of fractional frequency instability is 5.3×10 −18 at a 1-second averaging time under a homemade housing. It indicates that the doubler can be used to improve the short-term stability of strontium optical clocks with the best up-to-date ultra-stable lasers. Meanwhile, its high efficiency can match increasing interrogation laser power for further applications.
- 12 January 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (3) , 729-737
Modeling, analysis, and loop optimization of the Pound–Drever–Hall loop for ultra-stable lasers
State-of-the-art ultra-stable lasers have achieved a fractional frequency stability at the 10 −17 level. Further advancement to the 10 −18 level requires frequency stabilization servo controllers with stronger noise suppression capabilities over a broader frequency band. For external-cavity semiconductor lasers, the prevailing stabilization approach utilizes a combination of current frequency modulation and PZT frequency modulation. In this study, we employed a dedicated loop analyzer and an IQ demodulation frequency measurement method to perform detailed measurements of the transfer functions of individual stages and the closed-loop system of this dual feedback loop, with particular focus on its performance limitations in the frequency range within 10 kHz. By optimizing the feedback path, we improved the laser noise suppression at 1 kHz by three orders of magnitude, thereby reducing the contribution of residual laser frequency noise below 10 kHz to the fractional frequency stability at one second to 4.4×10 −19 . The proposed method not only provides significant value for achieving ultra-stable lasers at the 10 −18 level but is also applicable to newer types of semiconductor lasers that rely solely on current frequency modulation.
- 12 January 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (3) , 729-737
Modeling, analysis, and loop optimization of the Pound–Drever–Hall loop for ultra-stable lasers
State-of-the-art ultra-stable lasers have achieved a fractional frequency stability at the 10 −17 level. Further advancement to the 10 −18 level requires frequency stabilization servo controllers with stronger noise suppression capabilities over a broader frequency band. For external-cavity semiconductor lasers, the prevailing stabilization approach utilizes a combination of current frequency modulation and PZT frequency modulation. In this study, we employed a dedicated loop analyzer and an IQ demodulation frequency measurement method to perform detailed measurements of the transfer functions of individual stages and the closed-loop system of this dual feedback loop, with particular focus on its performance limitations in the frequency range within 10 kHz. By optimizing the feedback path, we improved the laser noise suppression at 1 kHz by three orders of magnitude, thereby reducing the contribution of residual laser frequency noise below 10 kHz to the fractional frequency stability at one second to 4.4×10 −19 . The proposed method not only provides significant value for achieving ultra-stable lasers at the 10 −18 level but is also applicable to newer types of semiconductor lasers that rely solely on current frequency modulation.
- 23 December 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (26) , 263402
Zero-Dead-Time Strontium Lattice Clock with a Stability at 10 − 19 Level
Optical atomic clocks play a crucial role in fundamental physics, relativistic geodesy, and the future redefinition of the Systeme International second. Standard operation relies on cyclic interrogation sequences, which alternate between atomic interrogation and dead time used for state preparation and readout. This approach introduces the Dick effect, where laser frequency noise aliases onto the atomic transition frequency. Although reducing laser noise improves clock stability, the Dick effect remains a key limitation. In this Letter, we demonstrate a zero-dead-time optical clock based on two interleaved ensembles of cold ^{87}Sr atoms. Our system significantly suppresses this noise and achieves a fractional frequency instability at the 10^{-19} level between 10 000 and 20 000 s over repeated measurements, with a best value of 2.9×10^{-19} at τ=20000 s. The estimated long-term stability based on the combined data of these measurements reaches 2.5×10^{-19} at 1 day. These results represent a more than ninefold improvement over a conventional single-ensemble clock, highlighting its potential for next-generation timekeeping applications.
- 23 December 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (26) , 263402
Zero-Dead-Time Strontium Lattice Clock with a Stability at 10 − 19 Level
Optical atomic clocks play a crucial role in fundamental physics, relativistic geodesy, and the future redefinition of the Systeme International second. Standard operation relies on cyclic interrogation sequences, which alternate between atomic interrogation and dead time used for state preparation and readout. This approach introduces the Dick effect, where laser frequency noise aliases onto the atomic transition frequency. Although reducing laser noise improves clock stability, the Dick effect remains a key limitation. In this Letter, we demonstrate a zero-dead-time optical clock based on two interleaved ensembles of cold ^{87}Sr atoms. Our system significantly suppresses this noise and achieves a fractional frequency instability at the 10^{-19} level between 10 000 and 20 000 s over repeated measurements, with a best value of 2.9×10^{-19} at τ=20000 s. The estimated long-term stability based on the combined data of these measurements reaches 2.5×10^{-19} at 1 day. These results represent a more than ninefold improvement over a conventional single-ensemble clock, highlighting its potential for next-generation timekeeping applications.
- 21 August 2025
- Published by Optica Publishing Group in Optica
- Vol. 12 (9) , 1342
Transportable single-crystal silicon ultra-stable cavity toward space applications
Ultra-stable lasers with extremely low-frequency noise are essential for space-based precision metrology. Transportable single-crystal silicon optical reference cavities offer lower thermal noise floors in compact volumes, making them ideal candidates for ultra-stable lasers deployed in space. However, achieving low vibration sensitivity in transportable designs remains challenging due to the anisotropic mechanical properties of silicon. In this work, we present a finite element method (FEM) optimized design for transportable single-crystal silicon cavities, featuring a 112.5 mm long spacer supported by an Invar six-point mounting frame, and a predicted thermal noise floor of 8.9×10−17. The assembly successfully withstood in-vehicle transportation and cryogenic thermal cycling tests. Moreover, we have established an ultra-stable laser system based on the cavity operating at 124 K, experimentally measured its total vibration sensitivity of 4.9(1)×10−10/g, and estimated the fractional frequency instability of 4×10−16 for averaging times ranging from 0.5 to 100 s. These results demonstrate that our cavity design takes the first step in the way for future ultra-stable lasers for space-based precision metrology and fundamental physics experiments.
- 21 August 2025
- Published by Optica Publishing Group in Optica
- Vol. 12 (9) , 1342
Transportable single-crystal silicon ultra-stable cavity toward space applications
Ultra-stable lasers with extremely low-frequency noise are essential for space-based precision metrology. Transportable single-crystal silicon optical reference cavities offer lower thermal noise floors in compact volumes, making them ideal candidates for ultra-stable lasers deployed in space. However, achieving low vibration sensitivity in transportable designs remains challenging due to the anisotropic mechanical properties of silicon. In this work, we present a finite element method (FEM) optimized design for transportable single-crystal silicon cavities, featuring a 112.5 mm long spacer supported by an Invar six-point mounting frame, and a predicted thermal noise floor of 8.9×10−17. The assembly successfully withstood in-vehicle transportation and cryogenic thermal cycling tests. Moreover, we have established an ultra-stable laser system based on the cavity operating at 124 K, experimentally measured its total vibration sensitivity of 4.9(1)×10−10/g, and estimated the fractional frequency instability of 4×10−16 for averaging times ranging from 0.5 to 100 s. These results demonstrate that our cavity design takes the first step in the way for future ultra-stable lasers for space-based precision metrology and fundamental physics experiments.
- 6 May 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (10) , 20419-20432
Automatic coupling of high-finesse Fabry-Pérot cavities with a mode convergence algorithm
The high-finesse Fabry-Pérot cavity is the most critical component of an ultra-stable laser. The coupling efficiency of the intra-cavity beam directly influences the frequency stability of ultra-stable lasers. For transportable or space-borne ultra-stable lasers, an automatic coupling procedure is typically required to address the reduction in coupling efficiency caused by environmental changes. We propose an automatic coupling method based on coupling efficiency feedback, which can achieve a fundamental mode coupling efficiency of 94% within a cavity displacement of 1.6 mm. Compared to conventional image recognition-based methods, our approach eliminates the need for bulky and expensive charge-coupled devices and complex image recognition algorithms. Most importantly, the maximum coupling range and coupling efficiency are no longer limited by the algorithm but are determined by hardware performance. This makes our automatic coupling method highly suitable for transportable and space-borne ultra-stable lasers.
- 6 May 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (10) , 20419-20432
Automatic coupling of high-finesse Fabry-Pérot cavities with a mode convergence algorithm
The high-finesse Fabry-Pérot cavity is the most critical component of an ultra-stable laser. The coupling efficiency of the intra-cavity beam directly influences the frequency stability of ultra-stable lasers. For transportable or space-borne ultra-stable lasers, an automatic coupling procedure is typically required to address the reduction in coupling efficiency caused by environmental changes. We propose an automatic coupling method based on coupling efficiency feedback, which can achieve a fundamental mode coupling efficiency of 94% within a cavity displacement of 1.6 mm. Compared to conventional image recognition-based methods, our approach eliminates the need for bulky and expensive charge-coupled devices and complex image recognition algorithms. Most importantly, the maximum coupling range and coupling efficiency are no longer limited by the algorithm but are determined by hardware performance. This makes our automatic coupling method highly suitable for transportable and space-borne ultra-stable lasers.
- 1 May 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (5)
An ultra-low noise and high-gain servo controller for ultra-stable laser systems
State-of-the-art ultra-stable laser systems exhibit fractional frequency stability on the order of 10−17. The imminent challenge lies in advancing this stability to the 10−18 range, thereby approaching the fundamental limit imposed by thermal noise. To achieve such a milestone, it is necessary that all technical noise sources, particularly electrical noise, be suppressed well below the level of thermal noise. As an initial stride toward 10−18 stability, we have improved an ultra-stable laser system through the redesign of its frequency stabilization feedback electronics, introducing an innovative servo controller architecture. This innovative servo controller incorporates a pre-amp stage comprising 16 parallel operational amplifiers, which feeds into a high-gain stage constituted by four cascaded integrators. This design yields an impressive input noise floor of 1.4 nV/Hz at 1 Hz and delivers a substantial servo gain of 230 dB at 1 Hz. Consequently, the upgraded ultra-stable laser system exhibits a residual in-loop error noise that contributes a mere fractional frequency stability of 4.7 × 10−20, signifying an improvement of two orders of magnitude. This significant advancement not only paves the way for addressing other technical noise challenges but also holds immense appeal for applications demanding utmost precision, including ultra-stable laser systems, gravitational wave detectors, and optical clocks.
- 1 May 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (5)
An ultra-low noise and high-gain servo controller for ultra-stable laser systems
State-of-the-art ultra-stable laser systems exhibit fractional frequency stability on the order of 10−17. The imminent challenge lies in advancing this stability to the 10−18 range, thereby approaching the fundamental limit imposed by thermal noise. To achieve such a milestone, it is necessary that all technical noise sources, particularly electrical noise, be suppressed well below the level of thermal noise. As an initial stride toward 10−18 stability, we have improved an ultra-stable laser system through the redesign of its frequency stabilization feedback electronics, introducing an innovative servo controller architecture. This innovative servo controller incorporates a pre-amp stage comprising 16 parallel operational amplifiers, which feeds into a high-gain stage constituted by four cascaded integrators. This design yields an impressive input noise floor of 1.4 nV/Hz at 1 Hz and delivers a substantial servo gain of 230 dB at 1 Hz. Consequently, the upgraded ultra-stable laser system exhibits a residual in-loop error noise that contributes a mere fractional frequency stability of 4.7 × 10−20, signifying an improvement of two orders of magnitude. This significant advancement not only paves the way for addressing other technical noise challenges but also holds immense appeal for applications demanding utmost precision, including ultra-stable laser systems, gravitational wave detectors, and optical clocks.
- 1 May 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (5)
Digital controlled analog servo with auto-lock for atomic, molecular, and optical experiments
High-performance servo systems play a crucial role in Pound–Drever–Hall (PDH) locking for ultra-stable lasers. Meanwhile, the timing sequence of cold atom experiments demands greater functionality and flexibility. To address this, we have developed a digital control high-performance analog servo based on field programmable gate arrays (FPGA), which combines the low noise and high bandwidth characteristics of traditional analog servo systems with the advanced capabilities of FPGAs, featuring an input noise of 4.9 μV. The FPGA-implemented automatic locking feature enables the PDH control loop to maintain its lock for prolonged periods in unattended environments. In addition, the dynamic hold functionality permits real-time synchronization with the timing of atomic experiments. We also conduct a detailed analysis of the digital noise introduced by the FPGA within the analog channel and propose a method to mitigate its impact by disabling the FPGA clock.
- 1 May 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (5)
Digital controlled analog servo with auto-lock for atomic, molecular, and optical experiments
High-performance servo systems play a crucial role in Pound–Drever–Hall (PDH) locking for ultra-stable lasers. Meanwhile, the timing sequence of cold atom experiments demands greater functionality and flexibility. To address this, we have developed a digital control high-performance analog servo based on field programmable gate arrays (FPGA), which combines the low noise and high bandwidth characteristics of traditional analog servo systems with the advanced capabilities of FPGAs, featuring an input noise of 4.9 μV. The FPGA-implemented automatic locking feature enables the PDH control loop to maintain its lock for prolonged periods in unattended environments. In addition, the dynamic hold functionality permits real-time synchronization with the timing of atomic experiments. We also conduct a detailed analysis of the digital noise introduced by the FPGA within the analog channel and propose a method to mitigate its impact by disabling the FPGA clock.
- 1 February 2025
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 64 (02) , 024101-16
Study on machine learning–assisted optimal thermal design of ultra-stable laser cavity
The ultra-stable laser is a key component of the optical frequency standard system, where one of the primary limitations on its secondary stability index arises from thermal noise. This makes it essential to maintain the laser cavity within an extremely stable thermal environment. We develop and validate experimentally a thermal model for a typical Fabry–Pérot cavity for accuracy. To improve the thermal stability of the design, a machine learning–assisted optimization design method is proposed, which includes a deep neural network surrogate model, sensitivity analysis, and multi-objective optimization based on the Pareto front. The primary optimization targets are minimizing temperature fluctuations and system weight. A case study demonstrates the efficacy of this approach, showing that the thermal response time constant increased from 97 h before optimization to 190 h after optimization, with only a minimal weight cost. Furthermore, under an external temperature fluctuation of 1 mK, the silicon crystal’s temperature fluctuation is reduced to 0.46 μK—an improvement over the 6μK fluctuation reported in previous studies. We provide crucial guidance for the thermal design of ultra-stable laser cavities, enhancing their accuracy and performance in optical systems.
- 1 February 2025
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 64 (02) , 024101-16
Study on machine learning–assisted optimal thermal design of ultra-stable laser cavity
The ultra-stable laser is a key component of the optical frequency standard system, where one of the primary limitations on its secondary stability index arises from thermal noise. This makes it essential to maintain the laser cavity within an extremely stable thermal environment. We develop and validate experimentally a thermal model for a typical Fabry–Pérot cavity for accuracy. To improve the thermal stability of the design, a machine learning–assisted optimization design method is proposed, which includes a deep neural network surrogate model, sensitivity analysis, and multi-objective optimization based on the Pareto front. The primary optimization targets are minimizing temperature fluctuations and system weight. A case study demonstrates the efficacy of this approach, showing that the thermal response time constant increased from 97 h before optimization to 190 h after optimization, with only a minimal weight cost. Furthermore, under an external temperature fluctuation of 1 mK, the silicon crystal’s temperature fluctuation is reduced to 0.46 μK—an improvement over the 6μK fluctuation reported in previous studies. We provide crucial guidance for the thermal design of ultra-stable laser cavities, enhancing their accuracy and performance in optical systems.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
An ultrastable 1397-nm laser stabilized by a crystalline-coated room-temperature cavity
State-of-the-art optical cavities are pivotal in pushing the envelope of laser frequency stability below 10−16. This is often achieved by extending the cavity length or cooling the system to cryogenic temperatures to reduce the thermal noise floor. In our study, we present a 30-cm-long cavity that operates at room temperature and is outfitted with crystalline coatings. The system has a predicted ultralow thermal noise floor of 4.4 × 10−17, comparable to what is observed in cryogenic silicon cavities. A 1397-nm laser is stabilized in this advanced cavity, and the stable frequency is then transferred to the clock transition in strontium optical lattice clocks via a frequency-doubling process. We have meticulously minimized and assessed the technical noise contributions through comparisons with an ultrastable reference laser that is locked to a commercially available 30-cm cavity. The frequency instability of the system is rigorously evaluated using a three-cornered-hat method. The results demonstrate that the laser frequency instability remains below 2 × 10−16 for averaging times ranging from 1 to 50 s. These findings underscore the significant potential of room-temperature cavities with crystalline coatings in high-precision metrology and pave the way for further improvements in optical lattice clocks.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
An ultrastable 1397-nm laser stabilized by a crystalline-coated room-temperature cavity
State-of-the-art optical cavities are pivotal in pushing the envelope of laser frequency stability below 10−16. This is often achieved by extending the cavity length or cooling the system to cryogenic temperatures to reduce the thermal noise floor. In our study, we present a 30-cm-long cavity that operates at room temperature and is outfitted with crystalline coatings. The system has a predicted ultralow thermal noise floor of 4.4 × 10−17, comparable to what is observed in cryogenic silicon cavities. A 1397-nm laser is stabilized in this advanced cavity, and the stable frequency is then transferred to the clock transition in strontium optical lattice clocks via a frequency-doubling process. We have meticulously minimized and assessed the technical noise contributions through comparisons with an ultrastable reference laser that is locked to a commercially available 30-cm cavity. The frequency instability of the system is rigorously evaluated using a three-cornered-hat method. The results demonstrate that the laser frequency instability remains below 2 × 10−16 for averaging times ranging from 1 to 50 s. These findings underscore the significant potential of room-temperature cavities with crystalline coatings in high-precision metrology and pave the way for further improvements in optical lattice clocks.
- Open Access
- 1 April 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (4)
Ultrahigh-reflective optical thin films prepared by reactive magnetron sputtering with RF-induced substrate bias
Optical thin films with high-reflectivity (HR) are essential for applications in quantum precision measurements. In this work, we propose a coating technique based on reactive magnetron sputtering with RF-induced substrate bias to fabricate HR-optical thin films. First, atomically flat SiO2 and Ta2O5 layers have been demonstrated due to the assistance of radio-frequency plasma during the coating process. Second, a distributed Bragg reflector (DBR) mirror with an HR of ∼99.999 328% centered at 1397 nm has been realized. The DBR structure is air-H{LH}19-substrate, in which the L and H denote a single layer of SiO2 with a thickness of 237.8 nm and a single layer of Ta2O5 with a thickness of 171.6 nm, respectively. This novel coating method would facilitate the development of HR reflectors and promote their wide applications in precision measurements.
- 1 April 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (4)
Open AccessUltrahigh-reflective optical thin films prepared by reactive magnetron sputtering with RF-induced substrate bias
Optical thin films with high-reflectivity (HR) are essential for applications in quantum precision measurements. In this work, we propose a coating technique based on reactive magnetron sputtering with RF-induced substrate bias to fabricate HR-optical thin films. First, atomically flat SiO2 and Ta2O5 layers have been demonstrated due to the assistance of radio-frequency plasma during the coating process. Second, a distributed Bragg reflector (DBR) mirror with an HR of ∼99.999 328% centered at 1397 nm has been realized. The DBR structure is air-H{LH}19-substrate, in which the L and H denote a single layer of SiO2 with a thickness of 237.8 nm and a single layer of Ta2O5 with a thickness of 171.6 nm, respectively. This novel coating method would facilitate the development of HR reflectors and promote their wide applications in precision measurements.