XZXian-Qing Zhu

Xian-Qing Zhu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xian-Qing Zhu has a total of 61 co-authors. Here are the top co-authors by number of shared publications:

  • Han-Ning Dai

    Hefei National Research Center for Physical Sciences at the Microscale and School of Physical Sciences, University of Science and Technology of China 1 , Hefei 230026

    8 shared publications
  • Ping Xu

    University of Science and Technology of China

    7 shared publications
  • Xiao Jiang

    Hefei National Research Center for Physical Sciences at the Microscale and School of Physical Sciences, University of Science and Technology of China 1 , Hefei 230026

    6 shared publications
  • De-Quan Kong

    Hefei National Research Center for Physical Sciences at the Microscale and School of Physical Sciences, University of Science and Technology of China 1 , Hefei 230026

    5 shared publications
  • Xing-Yang Cui

    5 shared publications
  • Yu-Ao Chen

    Hefei National Research Center for Physical Sciences at the Microscale and School of Physical Sciences, University of Science and Technology of China 1 , Hefei 230026

    4 shared publications

Latest Publications

  • Top Cited Papers
    Open Access

    Improved systematic evaluation of a strontium optical clock with uncertainty below 1 × 10 − 18

    by Zhi-Peng Jia, Jie Li, De-Quan Kong, Xiang Zhang, Hai-Wei Yu, Xiao-Yong Liu, Yu-Chen Zhang, Yuan-Bo Wang, Xian-Qing Zhu, Jia-Hao Zhang, et al.

    We report a systematic uncertainty of 9.2 × 10 − 19 for the Sr1 optical lattice clock at the University of Science and Technology of China (USTC), achieving accuracy at the level required for the roadmap of the redefinition of the SI second. A finite-element model with in situ -validated, spatially-resolved chamber emissivity reduced blackbody radiation (BBR) shift uncertainty to 6.3 × 10 − 19 . Concurrently, the externally mounted lattice cavity, by providing a larger beam waist, reduced the atomic density and thereby suppressed the density shift. Enhanced lattice depth modulation consolidated lattice light shift uncertainty to 6.3 × 10 − 19 by enabling simultaneous determination of key polarizabilities and magic wavelength. Magnetic shifts were resolved below 10 −18 via precision characterization of the second-order Zeeman coefficient. Supported by a clock laser stabilized on an ultralow-expansion glass cavity with crystalline-coated mirrors and refined temperature control suppressing BBR fluctuations, the clock also achieves a frequency stability better than 1 × 10 − 18 at 30 000 s averaging time. These developments collectively establish a new benchmark in USTC Sr1 clock performance and pave the way for high-accuracy applications in metrology and fundamental physics.


  • Modeling, analysis, and loop optimization of the Pound–Drever–Hall loop for ultra-stable lasers

    by Wenchao Ji, Yi Hu, Qian Wei, Xian-Qing Zhu, De-Quan Kong, Xing-Yang Cui, Ping Xu, Han-Ning Dai, Shengkai Liao, Yu-Ao Chen, et al.

    State-of-the-art ultra-stable lasers have achieved a fractional frequency stability at the 10 −17 level. Further advancement to the 10 −18 level requires frequency stabilization servo controllers with stronger noise suppression capabilities over a broader frequency band. For external-cavity semiconductor lasers, the prevailing stabilization approach utilizes a combination of current frequency modulation and PZT frequency modulation. In this study, we employed a dedicated loop analyzer and an IQ demodulation frequency measurement method to perform detailed measurements of the transfer functions of individual stages and the closed-loop system of this dual feedback loop, with particular focus on its performance limitations in the frequency range within 10 kHz. By optimizing the feedback path, we improved the laser noise suppression at 1 kHz by three orders of magnitude, thereby reducing the contribution of residual laser frequency noise below 10 kHz to the fractional frequency stability at one second to 4.4×10 −19 . The proposed method not only provides significant value for achieving ultra-stable lasers at the 10 −18 level but is also applicable to newer types of semiconductor lasers that rely solely on current frequency modulation.

  • Zero-Dead-Time Strontium Lattice Clock with a Stability at 10 − 19 Level

    by Xiao-Yong Liu, Peng Liu, Jie Li, Yu-Chen Zhang, Yuan-Bo Wang, Zhi-Peng Jia, Xiang Zhang, Xian-Qing Zhu, De-Quan Kong, Wen-Lan Song, et al.

    Optical atomic clocks play a crucial role in fundamental physics, relativistic geodesy, and the future redefinition of the Systeme International second. Standard operation relies on cyclic interrogation sequences, which alternate between atomic interrogation and dead time used for state preparation and readout. This approach introduces the Dick effect, where laser frequency noise aliases onto the atomic transition frequency. Although reducing laser noise improves clock stability, the Dick effect remains a key limitation. In this Letter, we demonstrate a zero-dead-time optical clock based on two interleaved ensembles of cold ^{87}Sr atoms. Our system significantly suppresses this noise and achieves a fractional frequency instability at the 10^{-19} level between 10 000 and 20 000 s over repeated measurements, with a best value of 2.9×10^{-19} at τ=20000 s. The estimated long-term stability based on the combined data of these measurements reaches 2.5×10^{-19} at 1 day. These results represent a more than ninefold improvement over a conventional single-ensemble clock, highlighting its potential for next-generation timekeeping applications.


  • Transportable single-crystal silicon ultra-stable cavity toward space applications

    by Xian-Qing Zhu, Xiao-Min Zhai, Yong Xie, Yuan Miao, Hai-Wei Yu, De-Quan Kong, Wen-Lan Song, Yi-Wen Zhang, Yi Hu, Xing-Yang Cui, et al.

    Ultra-stable lasers with extremely low-frequency noise are essential for space-based precision metrology. Transportable single-crystal silicon optical reference cavities offer lower thermal noise floors in compact volumes, making them ideal candidates for ultra-stable lasers deployed in space. However, achieving low vibration sensitivity in transportable designs remains challenging due to the anisotropic mechanical properties of silicon. In this work, we present a finite element method (FEM) optimized design for transportable single-crystal silicon cavities, featuring a 112.5 mm long spacer supported by an Invar six-point mounting frame, and a predicted thermal noise floor of 8.9×10−17. The assembly successfully withstood in-vehicle transportation and cryogenic thermal cycling tests. Moreover, we have established an ultra-stable laser system based on the cavity operating at 124 K, experimentally measured its total vibration sensitivity of 4.9(1)×10−10/g, and estimated the fractional frequency instability of 4×10−16 for averaging times ranging from 0.5 to 100 s. These results demonstrate that our cavity design takes the first step in the way for future ultra-stable lasers for space-based precision metrology and fundamental physics experiments.


  • An ultra-low noise and high-gain servo controller for ultra-stable laser systems

    by Wen-Chao Ji, Xian-Qing Zhu, Yi Hu, De-Quan Kong, Zhi-Peng Jia, Xiang-Pei Liu, Xing-Yang Cui, Ping Xu, Han-Ning Dai, Sheng-Kai Liao, et al.

    State-of-the-art ultra-stable laser systems exhibit fractional frequency stability on the order of 10−17. The imminent challenge lies in advancing this stability to the 10−18 range, thereby approaching the fundamental limit imposed by thermal noise. To achieve such a milestone, it is necessary that all technical noise sources, particularly electrical noise, be suppressed well below the level of thermal noise. As an initial stride toward 10−18 stability, we have improved an ultra-stable laser system through the redesign of its frequency stabilization feedback electronics, introducing an innovative servo controller architecture. This innovative servo controller incorporates a pre-amp stage comprising 16 parallel operational amplifiers, which feeds into a high-gain stage constituted by four cascaded integrators. This design yields an impressive input noise floor of 1.4 nV/Hz at 1 Hz and delivers a substantial servo gain of 230 dB at 1 Hz. Consequently, the upgraded ultra-stable laser system exhibits a residual in-loop error noise that contributes a mere fractional frequency stability of 4.7 × 10−20, signifying an improvement of two orders of magnitude. This significant advancement not only paves the way for addressing other technical noise challenges but also holds immense appeal for applications demanding utmost precision, including ultra-stable laser systems, gravitational wave detectors, and optical clocks.


  • Digital controlled analog servo with auto-lock for atomic, molecular, and optical experiments

    by Xinyun Huang, Yi Hu, Wenchao Ji, Zhipeng Jia, Xiang Zhang, Dequan Kong, Xianqing Zhu, Ping Xu, Hanning Dai, Xiao Jiang

    High-performance servo systems play a crucial role in Pound–Drever–Hall (PDH) locking for ultra-stable lasers. Meanwhile, the timing sequence of cold atom experiments demands greater functionality and flexibility. To address this, we have developed a digital control high-performance analog servo based on field programmable gate arrays (FPGA), which combines the low noise and high bandwidth characteristics of traditional analog servo systems with the advanced capabilities of FPGAs, featuring an input noise of 4.9 μV. The FPGA-implemented automatic locking feature enables the PDH control loop to maintain its lock for prolonged periods in unattended environments. In addition, the dynamic hold functionality permits real-time synchronization with the timing of atomic experiments. We also conduct a detailed analysis of the digital noise introduced by the FPGA within the analog channel and propose a method to mitigate its impact by disabling the FPGA clock.

  • An ultrastable 1397-nm laser stabilized by a crystalline-coated room-temperature cavity

    by Xian-Qing Zhu, Xing-Yang Cui, De-Quan Kong, Hai-Wei Yu, Xiao-Min Zhai, Ming-Yang Zheng, Xiu-Ping Xie, Qiang Zhang, Xiao Jiang, Xi-Bo Zhang, et al.

    State-of-the-art optical cavities are pivotal in pushing the envelope of laser frequency stability below 10−16. This is often achieved by extending the cavity length or cooling the system to cryogenic temperatures to reduce the thermal noise floor. In our study, we present a 30-cm-long cavity that operates at room temperature and is outfitted with crystalline coatings. The system has a predicted ultralow thermal noise floor of 4.4 × 10−17, comparable to what is observed in cryogenic silicon cavities. A 1397-nm laser is stabilized in this advanced cavity, and the stable frequency is then transferred to the clock transition in strontium optical lattice clocks via a frequency-doubling process. We have meticulously minimized and assessed the technical noise contributions through comparisons with an ultrastable reference laser that is locked to a commercially available 30-cm cavity. The frequency instability of the system is rigorously evaluated using a three-cornered-hat method. The results demonstrate that the laser frequency instability remains below 2 × 10−16 for averaging times ranging from 1 to 50 s. These findings underscore the significant potential of room-temperature cavities with crystalline coatings in high-precision metrology and pave the way for further improvements in optical lattice clocks.


  • Open Access

    Ultrahigh-reflective optical thin films prepared by reactive magnetron sputtering with RF-induced substrate bias

    by Tung-Hsun Chung, Xiao-Lu Zou, Qi-Hang Zhang, Meng Wang, Xian-Qing Zhu, Ming-Xuan Zhang, Qian-Cheng Lin, Rong Liao, Xing-Yang Cui, Jun Zhang, et al.

    Optical thin films with high-reflectivity (HR) are essential for applications in quantum precision measurements. In this work, we propose a coating technique based on reactive magnetron sputtering with RF-induced substrate bias to fabricate HR-optical thin films. First, atomically flat SiO2 and Ta2O5 layers have been demonstrated due to the assistance of radio-frequency plasma during the coating process. Second, a distributed Bragg reflector (DBR) mirror with an HR of ∼99.999 328% centered at 1397 nm has been realized. The DBR structure is air-H{LH}19-substrate, in which the L and H denote a single layer of SiO2 with a thickness of 237.8 nm and a single layer of Ta2O5 with a thickness of 171.6 nm, respectively. This novel coating method would facilitate the development of HR reflectors and promote their wide applications in precision measurements.