DKDe-Quan Kong

De-Quan Kong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


De-Quan Kong has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A 1.4 GHz radio frequency source with low phase noise and fast modulation for cold atom experiments

    by Mingyi Zhu, Peijun Feng, Xinyun Huang, Dequan Kong, Xinwei Jiang, Dandan Qin, Yuhong Lin, Tan Rao, Xiao Jiang

    We present a radio frequency source based on the AD9914 direct digital synthesizer chip, with a frequency range up to 1.4 GHz. The phase noise at an output frequency of 1 GHz is lower than −110 dBc/Hz at a 10 kHz offset. Through an optimized design of a field-programmable gate array, we have achieved the theoretical maximum modulation rate of AD9914 and developed multiple functional modules for cold atom experiments to implement modulation of frequency, phase, and amplitude. The modulation update rate reaches 146 MHz. The phase modulation response latency is 158 ns, and the amplitude modulation response latency is 95.1 ns. We have applied the RF source to a sideband Pound–Drever–Hall locking experiment and achieved frequency stabilization, demonstrating its suitability for cold atom experiments that require precise and complex laser control.

  • Top Cited Papers
    Open Access

    Improved systematic evaluation of a strontium optical clock with uncertainty below 1 × 10 − 18

    by Zhi-Peng Jia, Jie Li, De-Quan Kong, Xiang Zhang, Hai-Wei Yu, Xiao-Yong Liu, Yu-Chen Zhang, Yuan-Bo Wang, Xian-Qing Zhu, Jia-Hao Zhang, et al.

    We report a systematic uncertainty of 9.2 × 10 − 19 for the Sr1 optical lattice clock at the University of Science and Technology of China (USTC), achieving accuracy at the level required for the roadmap of the redefinition of the SI second. A finite-element model with in situ -validated, spatially-resolved chamber emissivity reduced blackbody radiation (BBR) shift uncertainty to 6.3 × 10 − 19 . Concurrently, the externally mounted lattice cavity, by providing a larger beam waist, reduced the atomic density and thereby suppressed the density shift. Enhanced lattice depth modulation consolidated lattice light shift uncertainty to 6.3 × 10 − 19 by enabling simultaneous determination of key polarizabilities and magic wavelength. Magnetic shifts were resolved below 10 −18 via precision characterization of the second-order Zeeman coefficient. Supported by a clock laser stabilized on an ultralow-expansion glass cavity with crystalline-coated mirrors and refined temperature control suppressing BBR fluctuations, the clock also achieves a frequency stability better than 1 × 10 − 18 at 30 000 s averaging time. These developments collectively establish a new benchmark in USTC Sr1 clock performance and pave the way for high-accuracy applications in metrology and fundamental physics.


  • Zero-Dead-Time Strontium Lattice Clock with a Stability at 10 − 19 Level

    by Xiao-Yong Liu, Peng Liu, Jie Li, Yu-Chen Zhang, Yuan-Bo Wang, Zhi-Peng Jia, Xiang Zhang, Xian-Qing Zhu, De-Quan Kong, Wen-Lan Song, et al.

    Optical atomic clocks play a crucial role in fundamental physics, relativistic geodesy, and the future redefinition of the Systeme International second. Standard operation relies on cyclic interrogation sequences, which alternate between atomic interrogation and dead time used for state preparation and readout. This approach introduces the Dick effect, where laser frequency noise aliases onto the atomic transition frequency. Although reducing laser noise improves clock stability, the Dick effect remains a key limitation. In this Letter, we demonstrate a zero-dead-time optical clock based on two interleaved ensembles of cold ^{87}Sr atoms. Our system significantly suppresses this noise and achieves a fractional frequency instability at the 10^{-19} level between 10 000 and 20 000 s over repeated measurements, with a best value of 2.9×10^{-19} at τ=20000 s. The estimated long-term stability based on the combined data of these measurements reaches 2.5×10^{-19} at 1 day. These results represent a more than ninefold improvement over a conventional single-ensemble clock, highlighting its potential for next-generation timekeeping applications.


  • An ultra-low noise and high-gain servo controller for ultra-stable laser systems

    by Wen-Chao Ji, Xian-Qing Zhu, Yi Hu, De-Quan Kong, Zhi-Peng Jia, Xiang-Pei Liu, Xing-Yang Cui, Ping Xu, Han-Ning Dai, Sheng-Kai Liao, et al.

    State-of-the-art ultra-stable laser systems exhibit fractional frequency stability on the order of 10−17. The imminent challenge lies in advancing this stability to the 10−18 range, thereby approaching the fundamental limit imposed by thermal noise. To achieve such a milestone, it is necessary that all technical noise sources, particularly electrical noise, be suppressed well below the level of thermal noise. As an initial stride toward 10−18 stability, we have improved an ultra-stable laser system through the redesign of its frequency stabilization feedback electronics, introducing an innovative servo controller architecture. This innovative servo controller incorporates a pre-amp stage comprising 16 parallel operational amplifiers, which feeds into a high-gain stage constituted by four cascaded integrators. This design yields an impressive input noise floor of 1.4 nV/Hz at 1 Hz and delivers a substantial servo gain of 230 dB at 1 Hz. Consequently, the upgraded ultra-stable laser system exhibits a residual in-loop error noise that contributes a mere fractional frequency stability of 4.7 × 10−20, signifying an improvement of two orders of magnitude. This significant advancement not only paves the way for addressing other technical noise challenges but also holds immense appeal for applications demanding utmost precision, including ultra-stable laser systems, gravitational wave detectors, and optical clocks.


  • Digital controlled analog servo with auto-lock for atomic, molecular, and optical experiments

    by Xinyun Huang, Yi Hu, Wenchao Ji, Zhipeng Jia, Xiang Zhang, Dequan Kong, Xianqing Zhu, Ping Xu, Hanning Dai, Xiao Jiang

    High-performance servo systems play a crucial role in Pound–Drever–Hall (PDH) locking for ultra-stable lasers. Meanwhile, the timing sequence of cold atom experiments demands greater functionality and flexibility. To address this, we have developed a digital control high-performance analog servo based on field programmable gate arrays (FPGA), which combines the low noise and high bandwidth characteristics of traditional analog servo systems with the advanced capabilities of FPGAs, featuring an input noise of 4.9 μV. The FPGA-implemented automatic locking feature enables the PDH control loop to maintain its lock for prolonged periods in unattended environments. In addition, the dynamic hold functionality permits real-time synchronization with the timing of atomic experiments. We also conduct a detailed analysis of the digital noise introduced by the FPGA within the analog channel and propose a method to mitigate its impact by disabling the FPGA clock.

  • An ultrastable 1397-nm laser stabilized by a crystalline-coated room-temperature cavity

    by Xian-Qing Zhu, Xing-Yang Cui, De-Quan Kong, Hai-Wei Yu, Xiao-Min Zhai, Ming-Yang Zheng, Xiu-Ping Xie, Qiang Zhang, Xiao Jiang, Xi-Bo Zhang, et al.

    State-of-the-art optical cavities are pivotal in pushing the envelope of laser frequency stability below 10−16. This is often achieved by extending the cavity length or cooling the system to cryogenic temperatures to reduce the thermal noise floor. In our study, we present a 30-cm-long cavity that operates at room temperature and is outfitted with crystalline coatings. The system has a predicted ultralow thermal noise floor of 4.4 × 10−17, comparable to what is observed in cryogenic silicon cavities. A 1397-nm laser is stabilized in this advanced cavity, and the stable frequency is then transferred to the clock transition in strontium optical lattice clocks via a frequency-doubling process. We have meticulously minimized and assessed the technical noise contributions through comparisons with an ultrastable reference laser that is locked to a commercially available 30-cm cavity. The frequency instability of the system is rigorously evaluated using a three-cornered-hat method. The results demonstrate that the laser frequency instability remains below 2 × 10−16 for averaging times ranging from 1 to 50 s. These findings underscore the significant potential of room-temperature cavities with crystalline coatings in high-precision metrology and pave the way for further improvements in optical lattice clocks.


  • An integrated high-flux cold atomic beam source for strontium

    by Jie Li, Zhi-Peng Jia, Peng Liu, Xiao-Yong Liu, De-Zhong Wang, De-Quan Kong, Su-Peng Li, Xing-Yang Cui, Han-Ning Dai, Yu-Ao Chen, et al.

    We present the design, construction, and characterization of an integrated cold atomic beam source for strontium (Sr), which is based on a compact Zeeman slower for slowing the thermal atomic beam and an atomic deflector for selecting the cold flux. By adopting arrays of permanent magnets to produce the magnetic fields of the slower and the deflector, we effectively reduce the system size and power compared to traditional systems with magnetic coils. After the slower cooling, one can employ additional transverse cooling in the radial direction and improve the atom collimation. The atomic deflectors employ two stages of two-dimensional magnetic-optical trapping (MOT) to deflect the cold flux, whose atomic speed is lower than 50 m/s, by 20° from the thermal atomic beam. We characterize the cold atomic beam flux of the source by measuring the loading rate of a three-dimensional MOT. The loading rates reach up to 109 atoms/s. The setup is compact, highly tunable, lightweight, and requires low electrical power, which addresses the challenge of reducing the complexity of building optical atomic clocks and quantum simulation devices based on Sr.