MSMehrgan Shahryari

Mehrgan Shahryari

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mehrgan Shahryari has a total of 96 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Stiffness and Tissue Viscosity in a Cerebral Neoplasm Measured by Preoperative Multifrequency Magnetic Resonance Elastography (MRE) Guide the Differential Diagnosis of Brain Tumors by Ruling Out Glioma

    by Mehrgan Shahryari, Boshra Shams, Helge Herthum, Pablo Gottheil, Jeremias Heider, Josef Käs, Eberhard Siebert, Thomas Picht, Ingolf Sack

    Here, we report the case of a 65‐year‐old man who presented to the emergency department with paresthesia, psychomotor retardation, and dysarthria. Contrast‐enhanced brain MRI revealed a solitary, contrast‐enhancing mass in the right head of the caudate nucleus with extensive perifocal edema, raising a primary differential diagnosis of glioblastoma versus metastasis, among other possibilities. Prior to surgical removal of the suspected glioblastoma, the patient underwent additional diffusion tensor imaging and research MRI, including multifrequency magnetic resonance elastography (MRE) to generate mechanical property maps of stiffness and tissue viscosity and to potentially differentiate between glioma, brain metastases, and benign masses based on tissue biomechanical properties. MRE revealed abnormally high values of stiffness and viscosity—a mechanical signature known to be associated with brain metastases or meningioma, but not glioblastoma, which typically exhibits soft tissue properties with reduced viscous dissipation. Histopathologic evaluation confirmed MRE by revealing a distant metastasis of squamous cell carcinoma, the primary tumor of which was detected by PET‐CT within the right hilus of the lung. This case demonstrates the diagnostic value of the biomechanical properties of brain tumors and raises the prospect of applying MRE as an easy‐to‐use MRI contrast that can rule out glioma when the suspicious lesion exhibits stiff‐viscous material properties.


  • Open Access

    Quantitative Analysis of Gadolinium Deposits in Liver Tissue of Patients After Single or Multiple Gadolinium-based Contrast Agent Application

    by Christian Bayerl, Mehrgan Shahryari, Rolf Reiter, Vanessa Proß, Kai Lehmann, Anja A. Kühl, Dorit Becker, Andreas Schulz, Carmen Infante-Duarte, Matthias Taupitz, et al.

    Objectives: Gadolinium-based contrast agents (GBCAs) are widely used in magnetic resonance imaging. Concerns exist regarding gadolinium deposition and its potential histopathologic tissue alterations, especially after repeated administrations of linear, less stable GBCAs. This study aimed to quantify gadolinium mass fractions in liver specimens of subjects exposed to GBCAs in correlation with histopathologic features. Materials and Methods: In this Institutional Review Board–approved study, mass fractions of gadolinium in human liver specimens ω(Gd) from 25 subjects who underwent liver tumor resection surgery and had received GBCA (1 to 9 times over 4 y), were quantitatively analyzed using inductively coupled plasma–mass spectrometry (ICP-MS). Histomorphology was assessed based on the nonalcoholic fatty liver disease activity score (NAS). Linear regression analyses were performed with ω(Gd), time and dosage metrics, and histopathologic parameters. Results: The median interval between last GBCA administration and surgery (T) was 14 days (range: 1 to 69 d). Gadolinium was detected in all liver samples (ω(Gd), median: 0.348 µg/g; range: 0.120 to 0.874 µg/g). No significant correlation was found between ω(Gd) and histologic scores, including inflammation and fibrosis. A strong negative correlation was found between ω(Gd) and ln(T) ( P < 0.001). A positive correlation existed between ω(Gd) and the number ( P = 0.010) but not the cumulative dose of previous GBCA administrations ( P = 0.205). Conclusions: Our results suggest that after intravenous administration of GBCA, a small fraction of gadolinium is retained in the liver over a time period of at least several weeks. A relationship was observed between Gadolinium retention and the number of GBCA administrations, but not with the cumulative dose and the degree of fatty liver disease.


  • Open Access

    Liver Viscosity Decreases Before the Onset of Fibrosis in Metabolic Dysfunction-Associated Steatohepatitis (MASH)

    by Yasmine Safraou, Kristin Susan Spirgath, Biru Huang, Christian Bayerl, Karolina Krehl, Anja A. Kühl, Tom Meyer, Mehrgan Shahryari, Pedro Dantas de Moraes, Jakob Jordan, et al.

    Background and Aim: Metabolic dysfunction-associated steatohepatitis (MASH) is an increasingly prevalent condition worldwide, associated with biomechanical liver changes and detectable by magnetic resonance elastography (MRE). This study explored the pathophysiological features and their biomechanical manifestations at different stages of MASH in a mouse dietary model. Methods: Using MRE on a clinical 3 Tesla MRI scanner, we measured liver stiffness, viscosity, fat fraction and water diffusion in 45 male mice. These values were correlated with histopathology and proteomics analyses to further characterize the liver microstructural and metabolic changes during MASH progression. Results: We found in a high-fat, low amino-acid model that early MASH was marked by fat accumulation and increasing inflammatory activity, while later stages showed a reduction in fat despite persistent inflammation. These changes in microstructure were associated with biomechanical adaptations, including a progressive decrease in hepatic viscosity and the water diffusion. Notably, viscosity was inversely correlated with lobular inflammation, cell adhesion, antioxidant activity, and metabolic adaptations such as enhanced ketone body synthesis. These findings, which precede the onset of fibrosis and tissue stiffening, show that tissue viscosity is highly sensitive to early microstructural and metabolic alterations in MASH. Conclusion: Steatosis and inflammation significantly alter liver biophysical properties, particularly viscosity, in a mouse dietary model of MASH, even in the absence of fibrosis. These findings suggest that viscosity is a potential early and clinically translatable biomarker for the development and progression of MASH.


  • Open Access

    Time‐resolved mapping of myocardial stiffness using 2D multifrequency spiral MR elastography with and without external vibration

    by Matthias S. Anders, Carsten Warmuth, Tom Meyer, Helge Herthum, Mehrgan Shahryari, Jakob Schattenfroh, Corona Metz, Jan Bieling, Josef Pfeuffer, Simon Veldhoen, et al.

    Purpose: There is a clinical need for stiffness mapping of the heart; however, current cardiac magnetic resonance elastography (cMRE) has limited spatiotemporal resolution. Therefore, we developed 2D spiral multifrequency MRE of the human heart and conducted a study to analyze the consistency and reproducibility of motion‐encoding and stiffness mapping with and without external vibration.Methods: Eleven healthy volunteers were studied using single‐slice gradient‐echo spiral cMRE with cardiac triggering and encoding of harmonic shear wave fields at 70, 80, and 90 Hz frequency generated by either external drivers or endogenous heart motion. Tissue displacement was monitored synchronized to the cardiac cycle, and frequency‐resolved shear wave speed (SWS) maps were reconstructed as a proxy for left ventricular (LV) stiffness variations. After several days, all subjects underwent repeat scanning for reproducibility analysis based on intraclass correlation coefficients (ICCs).Results: cMRE with external vibration showed LV SWS to be highest in end‐systole (ES) (2.17 ± 0.23 m/s), followed by diastole (DIA) (1.94 ± 0.15 m/s) and isovolumetric contraction (IVC) (1.78 ± 0.18 m/s). ICCs decreased with distance from the R‐wave from excellent (0.93) in IVC to moderate (0.68) in ES. Without external vibration, sufficient LV harmonic displacement amplitudes permitted SWS reconstruction, resulting in similar SWS, but lower ICC values than with external vibration in IVC and ES.Conclusions: Multifrequency cMRE offers high spatiotemporal resolution and reproducibility with external vibration. In addition, the technique allows the encoding of endogenous shear waves during cardiac phases with pronounced wall motion.


  • Open Access

    Intervertebral disc degeneration of the lumbar spine assessed in vivo with 3T magnetic resonance tomoelastography

    by Rolf Reiter, Pinkas Mürdel, Florian N Loch, Mehrgan Shahryari, Rebecca Strehle, Christian Bayerl, Jürgen Braun, Ingolf Sack, Patrick Asbach, David Kaufmann

    Introduction: Assessment of intervertebral disc (IVD) degeneration on conventional magnetic resonance imaging (MRI) is limited by large inter-reader variability and lack of stratification in clinical trials and their assessment of treatment responses. Therefore, we aimed to introduce and diagnostically validate multifrequency magnetic resonance elastography (MRE) with tomoelastography processing for the assessment of lumbar IVD degeneration in healthy volunteers and patients with low back pain. Methods: In this prospective single-center study, 60 participants (30 volunteers without low back pain and 30 patients with low back pain, 41 ± 17 years, body mass index 23.9 ± 3.7 kg/m2, 25 women) underwent multifrequency MRE using vibration frequencies from 40 to 70 Hz using a custom-built MRE setup in a 3T MRI scanner (Magnetom Skyra, software version XA30, Siemens Healthineers, Erlangen, Germany). Maps of shear wave speed (SWS in m/s) and loss angle (φ in rad), representing stiffness and viscous properties, respectively, were generated using tomoelastography data processing. The Pfirrmann score was used as reference standard to assess lumbar IVD degeneration on sagittal T2-weighted images. Inter-reader agreement (3 readers) and repeatability were assessed using the intraclass correlation coefficient (ICC). Results: Area under the receiver operating characteristic curve (AUC) analysis showed good diagnostic performance for detecting IVD degeneration (Pfirrmann score I/II/III/IV/V with n = 7/18/9/18/9, respectively) based on SWS (AUC: ≥II: 0.83, ≥III: 0.91, ≥IV: 0.96, V: 0.97) and φ (AUC: ≥II: 0.88, ≥III: 0.93, ≥IV: 0.98, V: 0.95). Good and excellent inter-reader agreements were found for Pfirrmann score (ICC = 0.87), SWS (ICC = 0.87), and φ (ICC = 0.92), respectively. Good repeatability was demonstrated for SWS (ICC = 0.88) and φ (ICC = 0.88). Discussion: Multifrequency MRE with tomoelastography processing allows effective IVD assessment and shows promise as a quantitative clinical imaging modality for assessing IVD degeneration.


  • Open Access

    Rapid MR elastography of the liver for subsecond stiffness sampling

    by Matthias Anders, Tom Meyer, Carsten Warmuth, Josef Pfeuffer, Heiko Tzschaetzsch, Helge Herthum, Mehrgan Shahryari, Katja Degenhardt, Oliver Wieben, Sebastian Schmitter, et al.

    Purpose: Depicting the stiffness of biological soft tissues, MR elastography (MRE) has a wide range of diagnostic applications. The purpose of this study was to improve the temporal resolution of 2D hepatic MRE in order to provide more rapid feedback on the quality of the wavefield and ensure better temporal sampling of respiration‐induced stiffness changes.Methods: We developed a rapid MRE sequence that uses 2D segmented gradient‐echo spiral readout to encode 40 Hz harmonic vibrations and generate stiffness maps within 625 ms. We demonstrate the use of this technique as a rapid test for shear wave amplitudes and overall MRE image quality and as a method for monitoring respiration‐induced stiffness changes in the liver in comparison to 3D MRE and ultrasound‐based time‐harmonic elastography.Results: Subsecond MRE allowed monitoring of increasing shear wave amplitudes in the liver with increasing levels of external stimulation within a single breath‐hold. Furthermore, the technique detected respiration‐induced changes in liver stiffness with peak values (1.83 ± 0.22 m/s) at end‐inspiration, followed by softer values during forced abdominal pressure (1.60 ± 0.22 m/s) and end‐expiration (1.49 ± 0.22 m/s). The effects of inspiration and expiration were confirmed by time‐harmonic elastography.Conclusion: Our results suggest that subsecond MRE of the liver is useful for checking MRE driver settings and monitoring breathing‐induced changes in liver stiffness in near real time.


  • Open Access

    Changes in Tissue Fluidity Predict Tumor Aggressiveness In Vivo

    by Frank Sauer, Steffen Grosser, Mehrgan Shahryari, Alexander Hayn, Jing Guo, Jürgen Braun, Susanne Briest, Benjamin Wolf, Bahriye Aktas, Lars‐Christian Horn, et al.

    Cancer progression is caused by genetic changes and associated with various alterations in cell properties, which also affect a tumor's mechanical state. While an increasedstiffnesshas been well known for long for solid tumors, it has limited prognostic power. It is hypothesized that cancer progression is accompanied by tissuefluidization, where portions of the tissue can change position across different length scales. Supported by tabletop magnetic resonance elastography (MRE) on stroma mimicking collagen gels and microscopic analysis of live cells inside patient derived tumor explants, an overview is provided of how cancer associated mechanisms, including cellular unjamming, proliferation, microenvironment composition, and remodeling can alter a tissue'sfluidityandstiffness. In vivo, state‐of‐the‐art multifrequency MRE can distinguish tumors from their surrounding host tissue by their rheological fingerprints. Most importantly, a meta‐analysis on the currently available clinical studies is conducted and universal trends are identified. The results and conclusions are condensed into a gedankenexperiment about how a tumor can grow and eventually metastasize into its environment from a physics perspective to deduce corresponding mechanical properties. Based onstiffness, fluidity,spatial heterogeneity, andtextureof thetumor fronta roadmap for a prognosis of a tumor's aggressiveness and metastatic potential is presented.


  • Open Access

    Supplementary Data from Tomoelastography Distinguishes Noninvasively between Benign and Malignant Liver Lesions

    by Mehrgan Shahryari, Heiko Tzschätzsch, Jing Guo, Stephan R. Marticorena Garcia, Georg Böning, Uli Fehrenbach, Lisa Stencel, Patrick Asbach, Bernd Hamm, Joseph A. Käs, et al.

    More tumor cases and details of patient inclusion, tomoelastography setup, mechanical parameters, and ROC analysis.

  • Open Access

    Data from Tomoelastography Distinguishes Noninvasively between Benign and Malignant Liver Lesions

    by Mehrgan Shahryari, Heiko Tzschätzsch, Jing Guo, Stephan R. Marticorena Garcia, Georg Böning, Uli Fehrenbach, Lisa Stencel, Patrick Asbach, Bernd Hamm, Joseph A. Käs, et al.

    Patients with increased liver stiffness have a higher risk of developing cancer, however, the role of fluid–solid tissue interactions and their contribution to liver tumor malignancy remains elusive. Tomoelastography is a novel imaging method for mapping quantitatively the solid–fluid tissue properties of soft tissues in vivo. It provides high resolution and thus has clear clinical applications. In this work we used tomoelastography in 77 participants, with a total of 141 focal liver lesions of different etiologies, to investigate the contributions of tissue stiffness and fluidity to the malignancy of liver tumors. Shear-wave speed (c) as surrogate for tissue stiffness and phase-angle (ϕ) of the complex shear modulus reflecting tissue fluidity were abnormally high in malignant tumors and allowed them to be distinguished from nontumorous liver tissue with high accuracy [c: AUC = 0.88 with 95% confidence interval (CI) = 0.83–0.94; ϕ: AUC = 0.95, 95% CI = 0.92–0.98]. Benign focal nodular hyperplasia and hepatocellular adenoma could be distinguished from malignant lesions on the basis of tumor stiffness (AUC = 0.85, 95% CI = 0.72–0.98; sensitivity = 94%, 95% CI = 89–100; and specificity = 85%, 95% CI = 62–100), tumor fluidity (AUC = 0.86, 95% CI = 0.77–0.96; sensitivity = 83%, 95% CI = 72–93; and specificity = 92%, 95% CI = 77–100) and liver stiffness (AUC = 0.84, 95% CI = 0.74–0.94; sensitivity = 72%, 95% CI = 59–83; and specificity = 88%, 95% CI = 69–100), but not on the basis of liver fluidity. Together, hepatic malignancies are characterized by stiff, yet fluid tissue properties, whereas surrounding nontumorous tissue is dominated by solid properties. Tomoelastography can inform noninvasively on the malignancy of suspicious liver lesions by differentiating between benign and malignant lesions with high sensitivity based on stiffness and with high specificity based on fluidity.Significance:Solid–fluid tissue properties measured by tomoelastography can distinguish malignant from benign masses with high accuracy and provide quantitative noninvasive imaging biomarkers for liver tumors.

  • Open Access

    Data from Tomoelastography Distinguishes Noninvasively between Benign and Malignant Liver Lesions

    by Mehrgan Shahryari, Heiko Tzschätzsch, Jing Guo, Stephan R. Marticorena Garcia, Georg Böning, Uli Fehrenbach, Lisa Stencel, Patrick Asbach, Bernd Hamm, Joseph A. Käs, et al.

    Patients with increased liver stiffness have a higher risk of developing cancer, however, the role of fluid–solid tissue interactions and their contribution to liver tumor malignancy remains elusive. Tomoelastography is a novel imaging method for mapping quantitatively the solid–fluid tissue properties of soft tissues in vivo. It provides high resolution and thus has clear clinical applications. In this work we used tomoelastography in 77 participants, with a total of 141 focal liver lesions of different etiologies, to investigate the contributions of tissue stiffness and fluidity to the malignancy of liver tumors. Shear-wave speed (c) as surrogate for tissue stiffness and phase-angle (ϕ) of the complex shear modulus reflecting tissue fluidity were abnormally high in malignant tumors and allowed them to be distinguished from nontumorous liver tissue with high accuracy [c: AUC = 0.88 with 95% confidence interval (CI) = 0.83–0.94; ϕ: AUC = 0.95, 95% CI = 0.92–0.98]. Benign focal nodular hyperplasia and hepatocellular adenoma could be distinguished from malignant lesions on the basis of tumor stiffness (AUC = 0.85, 95% CI = 0.72–0.98; sensitivity = 94%, 95% CI = 89–100; and specificity = 85%, 95% CI = 62–100), tumor fluidity (AUC = 0.86, 95% CI = 0.77–0.96; sensitivity = 83%, 95% CI = 72–93; and specificity = 92%, 95% CI = 77–100) and liver stiffness (AUC = 0.84, 95% CI = 0.74–0.94; sensitivity = 72%, 95% CI = 59–83; and specificity = 88%, 95% CI = 69–100), but not on the basis of liver fluidity. Together, hepatic malignancies are characterized by stiff, yet fluid tissue properties, whereas surrounding nontumorous tissue is dominated by solid properties. Tomoelastography can inform noninvasively on the malignancy of suspicious liver lesions by differentiating between benign and malignant lesions with high sensitivity based on stiffness and with high specificity based on fluidity.Significance:Solid–fluid tissue properties measured by tomoelastography can distinguish malignant from benign masses with high accuracy and provide quantitative noninvasive imaging biomarkers for liver tumors.