Helge Herthum
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Helge Herthum has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
- Ingolf Sack
Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany
10 shared publications - Jürgen Braun
Institute of Medical Informatics, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
8 shared publications - Mehrgan Shahryari
Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
6 shared publications - Heiko Tzschätzsch
Institute of Medical Informatics, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität Zu Berlin, Berlin, Germany
4 shared publications - Tom Meyer
Department of Radiology, Charite-Universitatsmedizin Berlin, Berlin, Germany
4 shared publications - Carsten Warmuth
Department of Radiology Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt‐Universität zu Berlin Berlin Germany
3 shared publications
Latest Publications
- Open Access
- 5 October 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (11) , e70405
MRpro: Open Framework for Model‐Based, Learned, and Quantitative MR Imaging—Application to Low‐Field MRI
MRpro is an open‐source framework for MR image reconstruction and quantitative parameter estimation, with particular relevance to low‐field MRI. Built on PyTorch, it supports modern deep‐learning reconstructions and standardized data exchange through ISMRMRD for raw k‐space data and DICOM and NIfTI for reconstructed images and parameter maps. This facilitates integration into existing pipelines and the use of data from different devices. MRpro provides unified data structures for the consistent manipulation of MR datasets and associated metadata, together with a library of composable operators, proximable functionals, and optimization algorithms. The operator library includes a unified Fourier operator for all common trajectories and operators specifically developed for low‐field applications, such as a B‐correction operator. Together, these components underpin ready‐to‐use implementations of key reconstruction algorithms. For deep learning, MRpro includes data‐consistency layers, differentiable optimization layers, state‐of‐the‐art backbone networks, and access to public datasets to facilitate reproducibility. Automated quality control supports collaborative development. We demonstrate MRpro for automatic reconstruction, iterative SENSE, deep‐learning‐based reconstruction, and quantitative parameter estimation. For selected Cartesian and non‐Cartesian tasks, iterative SENSE reconstructions from MRpro differed from those obtained with BART, SigPy, and MRIReco by less than 3% relative RMSE. Further applications use public and simulated datasets and measured low‐field data acquired at 0.3 T, 0.6 T, and 47 mT. MRpro provides a reproducible and maintainable foundation for future MR imaging research.
- 5 October 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (11) , e70405
Open AccessMRpro: Open Framework for Model‐Based, Learned, and Quantitative MR Imaging—Application to Low‐Field MRI
MRpro is an open‐source framework for MR image reconstruction and quantitative parameter estimation, with particular relevance to low‐field MRI. Built on PyTorch, it supports modern deep‐learning reconstructions and standardized data exchange through ISMRMRD for raw k‐space data and DICOM and NIfTI for reconstructed images and parameter maps. This facilitates integration into existing pipelines and the use of data from different devices. MRpro provides unified data structures for the consistent manipulation of MR datasets and associated metadata, together with a library of composable operators, proximable functionals, and optimization algorithms. The operator library includes a unified Fourier operator for all common trajectories and operators specifically developed for low‐field applications, such as a B‐correction operator. Together, these components underpin ready‐to‐use implementations of key reconstruction algorithms. For deep learning, MRpro includes data‐consistency layers, differentiable optimization layers, state‐of‐the‐art backbone networks, and access to public datasets to facilitate reproducibility. Automated quality control supports collaborative development. We demonstrate MRpro for automatic reconstruction, iterative SENSE, deep‐learning‐based reconstruction, and quantitative parameter estimation. For selected Cartesian and non‐Cartesian tasks, iterative SENSE reconstructions from MRpro differed from those obtained with BART, SigPy, and MRIReco by less than 3% relative RMSE. Further applications use public and simulated datasets and measured low‐field data acquired at 0.3 T, 0.6 T, and 47 mT. MRpro provides a reproducible and maintainable foundation for future MR imaging research.
- Open Access
- 5 February 2026
- Published by Elsevier in Acta Biomaterialia
- Vol. 213, 508-520
In vivo wideband MR elastography for assessing age-related viscoelasticity changes of the human brain
- 5 February 2026
- Published by Elsevier in Acta Biomaterialia
- Vol. 213, 508-520
Open AccessIn vivo wideband MR elastography for assessing age-related viscoelasticity changes of the human brain
- Open Access
- 28 July 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (6) , 2421-2434
Time‐resolved mapping of myocardial stiffness using 2D multifrequency spiral MR elastography with and without external vibration
Purpose: There is a clinical need for stiffness mapping of the heart; however, current cardiac magnetic resonance elastography (cMRE) has limited spatiotemporal resolution. Therefore, we developed 2D spiral multifrequency MRE of the human heart and conducted a study to analyze the consistency and reproducibility of motion‐encoding and stiffness mapping with and without external vibration.Methods: Eleven healthy volunteers were studied using single‐slice gradient‐echo spiral cMRE with cardiac triggering and encoding of harmonic shear wave fields at 70, 80, and 90 Hz frequency generated by either external drivers or endogenous heart motion. Tissue displacement was monitored synchronized to the cardiac cycle, and frequency‐resolved shear wave speed (SWS) maps were reconstructed as a proxy for left ventricular (LV) stiffness variations. After several days, all subjects underwent repeat scanning for reproducibility analysis based on intraclass correlation coefficients (ICCs).Results: cMRE with external vibration showed LV SWS to be highest in end‐systole (ES) (2.17 ± 0.23 m/s), followed by diastole (DIA) (1.94 ± 0.15 m/s) and isovolumetric contraction (IVC) (1.78 ± 0.18 m/s). ICCs decreased with distance from the R‐wave from excellent (0.93) in IVC to moderate (0.68) in ES. Without external vibration, sufficient LV harmonic displacement amplitudes permitted SWS reconstruction, resulting in similar SWS, but lower ICC values than with external vibration in IVC and ES.Conclusions: Multifrequency cMRE offers high spatiotemporal resolution and reproducibility with external vibration. In addition, the technique allows the encoding of endogenous shear waves during cardiac phases with pronounced wall motion.
- 28 July 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (6) , 2421-2434
Open AccessTime‐resolved mapping of myocardial stiffness using 2D multifrequency spiral MR elastography with and without external vibration
Purpose: There is a clinical need for stiffness mapping of the heart; however, current cardiac magnetic resonance elastography (cMRE) has limited spatiotemporal resolution. Therefore, we developed 2D spiral multifrequency MRE of the human heart and conducted a study to analyze the consistency and reproducibility of motion‐encoding and stiffness mapping with and without external vibration.Methods: Eleven healthy volunteers were studied using single‐slice gradient‐echo spiral cMRE with cardiac triggering and encoding of harmonic shear wave fields at 70, 80, and 90 Hz frequency generated by either external drivers or endogenous heart motion. Tissue displacement was monitored synchronized to the cardiac cycle, and frequency‐resolved shear wave speed (SWS) maps were reconstructed as a proxy for left ventricular (LV) stiffness variations. After several days, all subjects underwent repeat scanning for reproducibility analysis based on intraclass correlation coefficients (ICCs).Results: cMRE with external vibration showed LV SWS to be highest in end‐systole (ES) (2.17 ± 0.23 m/s), followed by diastole (DIA) (1.94 ± 0.15 m/s) and isovolumetric contraction (IVC) (1.78 ± 0.18 m/s). ICCs decreased with distance from the R‐wave from excellent (0.93) in IVC to moderate (0.68) in ES. Without external vibration, sufficient LV harmonic displacement amplitudes permitted SWS reconstruction, resulting in similar SWS, but lower ICC values than with external vibration in IVC and ES.Conclusions: Multifrequency cMRE offers high spatiotemporal resolution and reproducibility with external vibration. In addition, the technique allows the encoding of endogenous shear waves during cardiac phases with pronounced wall motion.
- Open Access
- 18 February 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (1) , 145-157
Tensor denoising of quantitative multi‐parameter mapping
Purpose: Quantitative multi‐parameter mapping (MPM) provides maps of physical quantities representing physiologically meaningful tissue characteristics, which allows to investigate microstructure‐function relationships reflecting normal or pathologic processes in the brain. However, the achievable spatial resolution and stability of MPM for basic research or clinical applications is severely constrained by SNR limits of the MR acquisition process, resulting in relatively long acquisition times. To increase SNR, we denoise MPM acquisitions using principal component analysis along tensors exploiting the Marchenko‐Pastur law (tMPPCA).Methods: tMPPCA denoising was applied to three sets of MPM raw data before the quantification of maps of proton density, magnetization transfer saturation, R1, and R2*. The regional SNR gain for high‐resolution MPM was investigated as well as reproducibility gains for clinically optimized protocols with moderate and high acceleration factors at different image resolutions.Results: Substantial noise reduction in raw data was achieved, resulting in reduced noise for quantitative mapping up to sixfold without introducing bias of mean values (below 1%). Scan–rescan fluctuations were reduced up to threefold. Denoising allowed to decrease the voxel volume fourfold at the same scan time or reduce the scan time twofold at same voxel volume without loss of sensitivity.Conclusions: tMPPCA denoising can (a) improve of fine spatial and temporal patterns, (b) considerably reduce scan time for clinical applications, or (c) increase resolution to potentially push cutting‐edge MPM protocols from the upper to the lower limit of the mesoscopic scale.
- 18 February 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (1) , 145-157
Open AccessTensor denoising of quantitative multi‐parameter mapping
Purpose: Quantitative multi‐parameter mapping (MPM) provides maps of physical quantities representing physiologically meaningful tissue characteristics, which allows to investigate microstructure‐function relationships reflecting normal or pathologic processes in the brain. However, the achievable spatial resolution and stability of MPM for basic research or clinical applications is severely constrained by SNR limits of the MR acquisition process, resulting in relatively long acquisition times. To increase SNR, we denoise MPM acquisitions using principal component analysis along tensors exploiting the Marchenko‐Pastur law (tMPPCA).Methods: tMPPCA denoising was applied to three sets of MPM raw data before the quantification of maps of proton density, magnetization transfer saturation, R1, and R2*. The regional SNR gain for high‐resolution MPM was investigated as well as reproducibility gains for clinically optimized protocols with moderate and high acceleration factors at different image resolutions.Results: Substantial noise reduction in raw data was achieved, resulting in reduced noise for quantitative mapping up to sixfold without introducing bias of mean values (below 1%). Scan–rescan fluctuations were reduced up to threefold. Denoising allowed to decrease the voxel volume fourfold at the same scan time or reduce the scan time twofold at same voxel volume without loss of sensitivity.Conclusions: tMPPCA denoising can (a) improve of fine spatial and temporal patterns, (b) considerably reduce scan time for clinical applications, or (c) increase resolution to potentially push cutting‐edge MPM protocols from the upper to the lower limit of the mesoscopic scale.
- Open Access
- 14 September 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (1) , 312-324
Rapid MR elastography of the liver for subsecond stiffness sampling
Purpose: Depicting the stiffness of biological soft tissues, MR elastography (MRE) has a wide range of diagnostic applications. The purpose of this study was to improve the temporal resolution of 2D hepatic MRE in order to provide more rapid feedback on the quality of the wavefield and ensure better temporal sampling of respiration‐induced stiffness changes.Methods: We developed a rapid MRE sequence that uses 2D segmented gradient‐echo spiral readout to encode 40 Hz harmonic vibrations and generate stiffness maps within 625 ms. We demonstrate the use of this technique as a rapid test for shear wave amplitudes and overall MRE image quality and as a method for monitoring respiration‐induced stiffness changes in the liver in comparison to 3D MRE and ultrasound‐based time‐harmonic elastography.Results: Subsecond MRE allowed monitoring of increasing shear wave amplitudes in the liver with increasing levels of external stimulation within a single breath‐hold. Furthermore, the technique detected respiration‐induced changes in liver stiffness with peak values (1.83 ± 0.22 m/s) at end‐inspiration, followed by softer values during forced abdominal pressure (1.60 ± 0.22 m/s) and end‐expiration (1.49 ± 0.22 m/s). The effects of inspiration and expiration were confirmed by time‐harmonic elastography.Conclusion: Our results suggest that subsecond MRE of the liver is useful for checking MRE driver settings and monitoring breathing‐induced changes in liver stiffness in near real time.
- 14 September 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (1) , 312-324
Open AccessRapid MR elastography of the liver for subsecond stiffness sampling
Purpose: Depicting the stiffness of biological soft tissues, MR elastography (MRE) has a wide range of diagnostic applications. The purpose of this study was to improve the temporal resolution of 2D hepatic MRE in order to provide more rapid feedback on the quality of the wavefield and ensure better temporal sampling of respiration‐induced stiffness changes.Methods: We developed a rapid MRE sequence that uses 2D segmented gradient‐echo spiral readout to encode 40 Hz harmonic vibrations and generate stiffness maps within 625 ms. We demonstrate the use of this technique as a rapid test for shear wave amplitudes and overall MRE image quality and as a method for monitoring respiration‐induced stiffness changes in the liver in comparison to 3D MRE and ultrasound‐based time‐harmonic elastography.Results: Subsecond MRE allowed monitoring of increasing shear wave amplitudes in the liver with increasing levels of external stimulation within a single breath‐hold. Furthermore, the technique detected respiration‐induced changes in liver stiffness with peak values (1.83 ± 0.22 m/s) at end‐inspiration, followed by softer values during forced abdominal pressure (1.60 ± 0.22 m/s) and end‐expiration (1.49 ± 0.22 m/s). The effects of inspiration and expiration were confirmed by time‐harmonic elastography.Conclusion: Our results suggest that subsecond MRE of the liver is useful for checking MRE driver settings and monitoring breathing‐induced changes in liver stiffness in near real time.
- Open Access
- 8 December 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 138, 105613
Mechanical behavior of the hippocampus and corpus callosum: An attempt to reconcile ex vivo with in vivo and micro with macro properties
- 8 December 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 138, 105613
Open AccessMechanical behavior of the hippocampus and corpus callosum: An attempt to reconcile ex vivo with in vivo and micro with macro properties
- Open Access
- 12 June 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (4) , 1840-1850
Comparison of inversion methods inMRelastography: An open‐access pipeline for processing multifrequency shear‐wave data and demonstration in a phantom, human kidneys, and brain
Purpose: Magnetic resonance elastography (MRE) maps the viscoelastic properties of soft tissues for diagnostic purposes. However, different MRE inversion methods yield different results, which hinder comparison of values, standardization, and establishment of quantitative MRE markers. Here, we introduce an expandable, open‐access, webserver‐based platform that offers multiple inversion techniques for multifrequency, 3D MRE data.Methods: The platform comprises a data repository and standard MRE inversion methods including local frequency estimation (LFE), direct‐inversion based multifrequency dual elasto‐visco (MDEV) inversion, and wavenumber‐based (k‐) MDEV. The use of the platform is demonstrated in phantom data and in vivo multifrequency MRE data of the kidneys and brains of healthy volunteers.Results: Detailed maps of stiffness were generated by all inversion methods showing similar detail of anatomy. Specifically, the inner renal cortex had higher shear wave speed (SWS) than renal medulla and outer cortex without lateral differences.k‐MDEV yielded higher SWS values than MDEV or LFE (full kidney/braink‐MDEV: 2.71 ± 0.19/1.45 ± 0.14 m/s, MDEV: 2.14 ± 0.16/0.99 ± 0.11 m/s, LFE: 2.12 ± 0.15/0.89 ± 0.06 m/s).Conclusion: The freely accessible platform supports the comparison of MRE results obtained with different inversion methods, filter thresholds, or excitation frequencies, promoting reproducibility in MRE across community‐developed methods.
- 12 June 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (4) , 1840-1850
Open AccessComparison of inversion methods inMRelastography: An open‐access pipeline for processing multifrequency shear‐wave data and demonstration in a phantom, human kidneys, and brain
Purpose: Magnetic resonance elastography (MRE) maps the viscoelastic properties of soft tissues for diagnostic purposes. However, different MRE inversion methods yield different results, which hinder comparison of values, standardization, and establishment of quantitative MRE markers. Here, we introduce an expandable, open‐access, webserver‐based platform that offers multiple inversion techniques for multifrequency, 3D MRE data.Methods: The platform comprises a data repository and standard MRE inversion methods including local frequency estimation (LFE), direct‐inversion based multifrequency dual elasto‐visco (MDEV) inversion, and wavenumber‐based (k‐) MDEV. The use of the platform is demonstrated in phantom data and in vivo multifrequency MRE data of the kidneys and brains of healthy volunteers.Results: Detailed maps of stiffness were generated by all inversion methods showing similar detail of anatomy. Specifically, the inner renal cortex had higher shear wave speed (SWS) than renal medulla and outer cortex without lateral differences.k‐MDEV yielded higher SWS values than MDEV or LFE (full kidney/braink‐MDEV: 2.71 ± 0.19/1.45 ± 0.14 m/s, MDEV: 2.14 ± 0.16/0.99 ± 0.11 m/s, LFE: 2.12 ± 0.15/0.89 ± 0.06 m/s).Conclusion: The freely accessible platform supports the comparison of MRE results obtained with different inversion methods, filter thresholds, or excitation frequencies, promoting reproducibility in MRE across community‐developed methods.
- Open Access
- 14 March 2022
- Published by Elsevier in Medical Image Analysis
- Vol. 78, 102416
Multiple motion encoding in phase-contrast MRI: A general theory and application to elastography imaging
- 14 March 2022
- Published by Elsevier in Medical Image Analysis
- Vol. 78, 102416
Open AccessMultiple motion encoding in phase-contrast MRI: A general theory and application to elastography imaging
- 1 January 2022
- Published by Elsevier in Acta Biomaterialia
- Vol. 138, 410-421
In vivo stiffness of multiple sclerosis lesions is similar to that of normal-appearing white matter
- 1 January 2022
- Published by Elsevier in Acta Biomaterialia
- Vol. 138, 410-421
In vivo stiffness of multiple sclerosis lesions is similar to that of normal-appearing white matter
- Open Access
- 9 November 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (3) , 1435-1445
Microscopic multifrequency MR elastography for mapping viscoelasticity in zebrafish
Purpose: The zebrafish (Danio rerio) has become an important animal model in a wide range of biomedical research disciplines. Growing awareness of the role of biomechanical properties in tumor progression and neuronal development has led to an increasing interest in the noninvasive mapping of the viscoelastic properties of zebrafish by elastography methods applicable to bulky and nontranslucent tissues.Methods: Microscopic multifrequency MR elastography is introduced for mapping shear wave speed (SWS) and loss angle (φ) as markers of stiffness and viscosity of muscle, brain, and neuroblastoma tumors in postmortem zebrafish with 60 µm in‐plane resolution. Experiments were performed in a 7 Tesla MR scanner at 1, 1.2, and 1.4 kHz driving frequencies.Results: Detailed zebrafish viscoelasticity maps revealed that the midbrain region (SWS = 3.1 ± 0.7 m/s,φ = 1.2 ± 0.3 radian [rad]) was stiffer and less viscous than telencephalon (SWS = 2.6 ± 0. 5 m/s,φ = 1.4 ± 0.2 rad) and optic tectum (SWS = 2.6 ± 0.5 m/s,φ = 1.3 ± 0.4 rad), whereas the cerebellum (SWS = 2.9 ± 0.6 m/s,φ = 0.9 ± 0.4 rad) was stiffer but less viscous than both (allp < .05). Overall, brain tissue (SWS = 2.9 ± 0.4 m/s,φ = 1.2 ± 0.2 rad) had similar stiffness but lower viscosity values than muscle tissue (SWS = 2.9 ± 0.5 m/s,φ = 1.4 ± 0.2 rad), whereas neuroblastoma (SWS = 2.4 ± 0.3 m/s,φ = 0.7 ± 0.1 rad, allp < .05) was the softest and least viscous tissue.Conclusion: Microscopic multifrequency MR elastography‐generated maps of zebrafish show many details of viscoelasticity and resolve tissue regions, of great interest in neuromechanical and oncological research and for which our study provides first reference values.
- 9 November 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (3) , 1435-1445
Open AccessMicroscopic multifrequency MR elastography for mapping viscoelasticity in zebrafish
Purpose: The zebrafish (Danio rerio) has become an important animal model in a wide range of biomedical research disciplines. Growing awareness of the role of biomechanical properties in tumor progression and neuronal development has led to an increasing interest in the noninvasive mapping of the viscoelastic properties of zebrafish by elastography methods applicable to bulky and nontranslucent tissues.Methods: Microscopic multifrequency MR elastography is introduced for mapping shear wave speed (SWS) and loss angle (φ) as markers of stiffness and viscosity of muscle, brain, and neuroblastoma tumors in postmortem zebrafish with 60 µm in‐plane resolution. Experiments were performed in a 7 Tesla MR scanner at 1, 1.2, and 1.4 kHz driving frequencies.Results: Detailed zebrafish viscoelasticity maps revealed that the midbrain region (SWS = 3.1 ± 0.7 m/s,φ = 1.2 ± 0.3 radian [rad]) was stiffer and less viscous than telencephalon (SWS = 2.6 ± 0. 5 m/s,φ = 1.4 ± 0.2 rad) and optic tectum (SWS = 2.6 ± 0.5 m/s,φ = 1.3 ± 0.4 rad), whereas the cerebellum (SWS = 2.9 ± 0.6 m/s,φ = 0.9 ± 0.4 rad) was stiffer but less viscous than both (allp < .05). Overall, brain tissue (SWS = 2.9 ± 0.4 m/s,φ = 1.2 ± 0.2 rad) had similar stiffness but lower viscosity values than muscle tissue (SWS = 2.9 ± 0.5 m/s,φ = 1.4 ± 0.2 rad), whereas neuroblastoma (SWS = 2.4 ± 0.3 m/s,φ = 0.7 ± 0.1 rad, allp < .05) was the softest and least viscous tissue.Conclusion: Microscopic multifrequency MR elastography‐generated maps of zebrafish show many details of viscoelasticity and resolve tissue regions, of great interest in neuromechanical and oncological research and for which our study provides first reference values.