SCSeyong Choi

Seyong Choi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Seyong Choi has a total of 86 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Development of 2 km-Class Carbon-Doped MgB 2 Wire With Uniform Critical Current Property

    by Dong Gun Lee, Jun Hyuk Choi, Minoru Maeda, Seyong Choi, Jung Ho Kim

    Kilometer-scale carbon-doped MgB2 superconducting wires were fabricated using a three-dimensional vibrating powder-filling powder-in-tube process and systematically evaluated for uniformity and performance. The optimized process enabled fabrication of a 2.1 km-long 18 filament conductor with a critical current density (Jc) of 1.13 × 105 A/cm² at 20 K and 2 T, showing only ∼2% variation along its length. Carbon substitution enhanced high-field performance primarily through impurity scattering, while the n-value demonstrated a strong proportionality with Jc across all measured conditions. This correlation establishes the n-value as not only a research parameter but also a practical quality-control metric for industrial wire production. The combined achievements of process innovation and transport uniformity highlight the feasibility of MgB2 conductors for MRI magnets, high-field research magnets, and superconducting power transmission.

  • Core Technologies in HTS Coils for Particle-Therapy Accelerators: PRPD-Based Defect Diagnostics and Fast-Ramping Field Response

    by Jaesang Kim, Minkyung Jeong, Yechan Kim, Bonhyuk Ku, Junyol Sohn, Seungcheol Lee, Garam Hahn, Seyong Choi, Seungyong Hahn, Hyoungku Kang

    This paper proposes a non-destructive quality control method for High-Temperature Superconducting (HTS) coils based on Phase-Resolved Partial Discharge (PRPD) analysis. To ensure the safety of expensive REBCO tapes during high-voltage testing, stainless-steel (SS304) tapes with identical geometric dimensions ($0.32\rm{ mm}$ thickness, $4\rm{ mm}$ width) were utilized as electromagnetic surrogates. We investigated the PRPD signatures of various winding defects, such as protrusions and layer shifts, in pancake coil configurations. The results demonstrate that each defect type produces distinct “Phase-locked clusters,” providing a reliable diagnostic fingerprint for early-stage failure detection. Furthermore, this study evaluates the insulation performance of polytetrafluoroethylene (PTFE) spray coating as a method for achieving tailored insulation levels. Experimental results, including charging delay and field decay analysis, confirm that PTFE-coated coils exhibit dielectric stability comparable to conventional Kapton-insulated coils while offering superior flexibility in controlling the insulation grade. Given that medical particle accelerators operate under high-speed ramping ($L di/dt$), the localized field enhancement identified by PRPD serves as a critical early warning system to prevent quenches caused by mechanical stress or transient voltages. This study establishes a baseline for extending PRPD-based diagnostics to complex 3D HTS magnet systems, ensuring initial quality and long-term operational reliability.

  • Design, Construction, and Operational Testing of Dry-Wound Conduction-Cooled React-and-Wind MgB$_{2}$ Magnet

    by Wonseok Jang, Jaemin Kim, Geonyoung Kim, Chaemin Im, Seyong Choi, Jung Ho Kim, Jun Hyuk Choi, Dong Gun Lee, Seungyong Hahn, Sangjin Lee

    This study details the design, construction, and operational testing of a dry-wound conduction-cooled react-and-wind MgB$_{2}$ magnet. A turn-coloring method was employed for the precise dry winding of round wire, ensuring the winding was completed as per design specifications. Mechanically and thermally stable copper ring-shaped current lead structures with solder-filled helical grooved path were developed for the reacted wire. Following the cryogen-free cooling setup, the magnet was charged, resulting in a quench event at a current lower than the designed operating level. Analysis suggests that an unexpected heat source within the coil winding, combined with the absence of a pre-load structure that resulted in insufficient conduction cooling paths, led to localized heat accumulation and a subsequent quench. These findings highlight the need for improvements in magnet design and manufacturing, particularly in incorporating a coil pre-load structure to enhance thermal management and ensure the long-term reliability of conduction-cooled MgB$_{2}$ magnets.


  • Perspective on Kilometer-Scale MgB2 Superconducting Wires With 127 Filaments

    by Dong Gun Lee, Jun Hyuk Choi, Minoru Maeda, Seyong Choi, Jung Ho Kim

    Since 2015, we have successfully developed magnesium diboride (MgB2) wire at the 3 km-scale and achieved a high critical current density (Jc) of 3.5 × 105 A/mm2 at 4.2 K and 3 T for various applications. To ensure mechanical strength and performance stability, it is necessary to design MgB2 wire with a large number of internal filaments. In this study, we conducted a comparative analysis of the number/size of filaments and electrical properties of 19 (18 + 1Cu)-, 37 (30 + 7Cu)-, 61 (54 + 7Cu)-, 91 (72 + 19Cu and 78 + 13Cu)-, and 127 (114 + 13Cu)-filament MgB2 wires. Increasing the number of filaments had a minor effect on the fill factor and did not significantly enhance the Jc. However, it was observed that the deformation of the internal filaments became more inhomogeneous. The mean filament size of the 19-filament architecture was approximately 80 µm, while that of the 127-filament architecture showed a significant reduction, effectively reaching less than 33 µm. The microstructure and characterization of the produced wires are discussed in detail.


  • Open Access

    Evaluation of in-plane and out-of-plane crystallinities with residual amorphous phases for MgB2 superconductor

    by Minoru Maeda, Jun Hyuk Choi, Dong Gun Lee, Akiyoshi Matsumoto, Gen Nishijima, Zhenan Jiang, Nicholas M. Strickland, Jung Ho Kim, Seyong Choi


  • Conceptual Design of 1-T/360-mm Dry Wound Conduction Cooled MgB$_{2}$ Magnet for Long Term Operation

    by Wonseok Jang, Jaemin Kim, Geonyoung Kim, Hyunsoo Park, Seyong Choi, Jung Ho Kim, Jun Hyuk Choi, Dong Gun Lee, Seungyong Hahn, Sangjin Lee

    Conceptual design of a conduction-cooled MgB $_{2}$ magnet with an inner diameter of 360 mm and a center magnetic field of 1 T is presented. The magnet is designed as part of the magnet development activities to carry out the feasibility study and further, to demonstrate the applicability of the MgB $_{2}$ magnet in wide industrial applications which can be supported by the long-term operational data showing the robustness of the magnet. To achieve the goal of long-term robust magnet operation, mechanical design considering the react-and-wind conductor and design aspects of magnet stability and protection are considered. Due to the dry wound winding configuration, a detect-and-activate-heater technique is applied to the magnet as an active magnet protection.


  • A Study on the Improvement of the Superconducting Magnet System for the 28 GHz SC-ECRIS at KBSI

    by Jonggi Hong, Seong Jun Kim, Jung-Woo Ok, Taekyu Lee, Jang-Hee Yoon, Seyong Choi, Bonghyun Cho, Minwoo Kim, Jin Yong Park, Jiho Lee

    The Busan Ion Beam Accelerator (BIBA) is a compact linear accelerator facility utilizing the 28 GHz Superconducting Electron Cyclotron Resonance Ion Source (SC-ECRIS) at the Korea Basic Science Institute (KBSI). The primary objective of the BIBA is to produce fast neutrons tailored for high-resolution radiography technology and application. A recent development of a new ion implantation system employs the multi-charged ion beams, produced by 28 GHz SC-ECRIS. The 28 GHz SC-ECRIS generates a high magnetic field for strong plasma confinement. For the reliable operation of superconducting magnets, it is essential to analyze their electromagnetic characteristics to minimize the forces inducing coil motion and strain during excitation. In this paper, we have employed the inner yoke of the superconducting magnets to enhance the operational stability. The effect of the inner yoke has been analyzed by both a three-dimensional static finite element method simulation and magnetic field measurements in the plasma chamber. The research presents an analysis of the magnetic field and the electromagnetic force of the superconducting magnets under various conditions of the inner yokes. As a result, the magnetic field measurements were found to be in good agreement with the simulated results.


  • Design and Performance Analysis of Gradient Coil for High-Field HTS REBCO MRI Magnet

    by Hyunsoo Park, Geonyoung Kim, Kibum Choi, Jeonghwan Park, Jaemin Kim, Seyong Choi, Kideok Sim, Seungyong Hahn

    In this study, we designed gradient coils for a 6 T high-temperature superconducting (HTS) MRI magnet and analyzed their effects on the main magnet which was fabricated using rare-earth barium copper oxide (REBCO) conductor. First, we designed a total of 6 coils, which composed the X, Y, and Z gradient and shield coils. To ensure the performance of gradient system, we designed the gradient coil that satisfies the essential requirements such as linearity and uniformity. Second, we analyzed the effects of the gradient coil operations on the main magnet. Although the gradient shield coils prevented the main HTS magnet from experiencing magnetic field changes, the unshielded magnetic field leakage could generate screening currents in the REBCO conductor which could affect the performance of the main magnet. We simulated and analyzed the electromagnetic behaviors of the HTS REBCO magnet affected by the high-frequency varying field caused by the gradient coil operation.


  • Electrical Breakdown Characteristics in High-Vacuum Conditions for the Design of Superconducting Coils

    by Junyoung Park, Woocheol Shin, Minkyung Jeong, Bonhyuk Ku, Hobin Lee, Jeonghwan Park, Garam Hahn, Seyong Choi, Seungyong Hahn, Hyoungku Kang

    In recent years, the utilization of high-temperature superconductors (HTS) in medical devices, such as magnetic resonance imaging (MRI) and particle accelerators for cancer treatment, has seen significant growth. This study focuses on the electrical insulation design of fast-ramping HTS saddle magnets, pivotal in reducing the volume and consequent operational costs of particle accelerators. Generally, these HTS magnets are operated under high-vacuum conditions to deter external heat intrusion and optimize thermal efficiency. However, their intricate geometries can inadvertently result in areas of localized vacuum degradation, undermining their electrical insulation capabilities, especially in environments with pressures less than 0.001 Pa. Further, this research delves into the influence of vacuum degree and insulator surface roughness on the electrical breakdown properties. The focus is primarily on the distinctions between sparkover and flashover. Due to their fast-ramping nature, HTS magnets undergo substantial current changes in short durations, leading to the induction of potentially dangerous voltages that might trigger electrical breakdown at sensitive junctures. In light of these challenges, we embarked on a series of experiments to understand electrical breakdown phenomena under diverse vacuum scenarios. These experiments, supplemented with finite element method (FEM) analysis, paved the way for the derivation of empirical formula. These formulas intend to guide the design of HTS magnets, ensuring their electrical insulation remains robust across a range of vacuum conditions.

  • A Case Study of Advanced Ramp-Up Profile for HTS Magnet-Based Carbon Therapy Synchrotron

    by Woojin Song, Jeonghwan Park, Geonyoung Kim, Hyunsoo Park, Sehyun Kim, Taekyun Ha, Seungyong Hahn, Seyong Choi, Hyoungku Kang, Gunsu Yun, et al.

    In heavy ion medical synchrotrons, it is crucial to rapidly accelerate ions to reduce beam loss caused by interactions with residual gas and to shorten treatment duration. Superconducting technology can reduce machine size by generating high magnetic fields, but it is difficult to apply in realization because of the heat generation due to ac loss. As a potential solution to these problems, synchrotrons based on high-temperature superconductors (HTS) can offer advantages in stable accelerator operation due to their intrinsic high stability margin, despite the ac loss induced heating. Our study focuses on optimizing the ramp-up operation method of a heavy ion synchrotron (with medical applications) using HTS. We initially simulate ac losses based on the ramp-up profile in a conceptual magnet model of a medical application that utilizes HTS wire characteristics. Simultaneously, we employed a virtual beam to calculate how the beam-gas interaction affects emittance. Based on the results of these two calculations, we propose a current ramp-up profile that minimizes beam loss due to multiple scattering and maximum instantaneous heat load due to ac loss in synchrotrons using high-temperature superconducting magnets.