Jelena Kljakić
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jelena Kljakić has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Darija Gajić
Faculty of Architecture, Civil Engineering and Geodesy, University of Banja Luka, 78000 Banja Luka, Bosnia and Herzegovina
3 shared publications - Biljana Antunović
Faculty of Architecture, Civil Engineering and Geodesy, University of Banja Luka, 78000 Banja Luka, Bosnia and Herzegovina
2 shared publications - Ljubiša Preradović
Faculty of Architecture, Civil Engineering and Geodesy, University of Banja Luka, 78000 Banja Luka, Bosnia and Herzegovina
2 shared publications - Milan Pupčević
Faculty of Mechanical Engineering, University of Banja Luka, 78000 Banja Luka, Bosnia and Herzegovina
2 shared publications - Milovan Kotur
Faculty of Mechanical Engineering, University of Banja Luka, Bosnia and Herzegovina
2 shared publications - Saša Čvoro
Faculty of Architecture, Civil Engineering and Geodesy, University of Banja Luka, 78000 Banja Luka, Bosnia and Herzegovina
2 shared publications
Latest Publications
- Open Access
Analysis of Indoor Air Quality and Occupant Perception Under Different Mechanical Ventilation Operational Modes in a University Amphitheater
This paper presents an analysis of indoor air quality (IAQ) and occupant perception under different mechanical ventilation operational modes in a university amphitheater. Indoor environmental parameters, including air temperature, relative humidity, indoor air velocity, and CO2 concentration, were measured in accordance with ISO 7726. Ventilation performance and outdoor air supply requirements were evaluated according to BAS EN 16798-1 and ASHRAE 62.1, while thermal comfort interpretation followed ISO 7730. In parallel, a questionnaire survey was conducted to assess occupants’ perceptions of indoor air quality and its influence on concentration under different ventilation operating conditions. The results showed that CO2 concentrations occasionally exceeded 1000 ppm during extended occupancy periods but remained below 800 ppm for more than 60% of the measurement time. According to BAS EN 16798-1, the indoor environment was predominantly classified as Category I based on the indoor–outdoor CO2 concentration difference. Survey responses indicated that most students perceived the indoor air as clean, while 67% reported that IAQ influenced their ability to concentrate. The findings highlight the importance of occupancy-related ventilation control strategies in large educational spaces and demonstrate the potential for balancing indoor air quality and energy efficiency through appropriate ventilation system operation. The presented methodology may support future development of data-driven approaches for optimizing mechanical ventilation performance in university buildings.
Open AccessAnalysis of Indoor Air Quality and Occupant Perception Under Different Mechanical Ventilation Operational Modes in a University Amphitheater
This paper presents an analysis of indoor air quality (IAQ) and occupant perception under different mechanical ventilation operational modes in a university amphitheater. Indoor environmental parameters, including air temperature, relative humidity, indoor air velocity, and CO2 concentration, were measured in accordance with ISO 7726. Ventilation performance and outdoor air supply requirements were evaluated according to BAS EN 16798-1 and ASHRAE 62.1, while thermal comfort interpretation followed ISO 7730. In parallel, a questionnaire survey was conducted to assess occupants’ perceptions of indoor air quality and its influence on concentration under different ventilation operating conditions. The results showed that CO2 concentrations occasionally exceeded 1000 ppm during extended occupancy periods but remained below 800 ppm for more than 60% of the measurement time. According to BAS EN 16798-1, the indoor environment was predominantly classified as Category I based on the indoor–outdoor CO2 concentration difference. Survey responses indicated that most students perceived the indoor air as clean, while 67% reported that IAQ influenced their ability to concentrate. The findings highlight the importance of occupancy-related ventilation control strategies in large educational spaces and demonstrate the potential for balancing indoor air quality and energy efficiency through appropriate ventilation system operation. The presented methodology may support future development of data-driven approaches for optimizing mechanical ventilation performance in university buildings.
- Open Access
- 1 June 2026
- Published by University of Banja Luka, Faculty of Architecture, Civil Engineering and Geodesy
- Vol. 17 (1) , 38-47
ASSESSMENT OF DAYLIGHT AVAILABILITY IN AN EDUCATIONAL BUILDING
This study analyses daylight availability in a faculty lecture classroom using illuminance measurements and a survey of students. The results of the measurements conducted in mid-February showed that the recommended horizontal illuminance level (300 lx) was achieved at 50% of the measurement points around midday (12:00 h and 14:00 h), while only 0–15% of the area met this requirement at 8:00 h and 16:00 h. The minimum illuminance level (100 lx) was satisfied at all measurement points around midday but decreased to 25–45% in the early morning and late afternoon. Survey results indicated that 76.7% of students reported the need for artificial lighting during the winter period. Since natural daylight is sufficient during certain periods of the day, optimisation of the lighting system and the integration of controlled sensors for supplementary lighting are recommended.
- 1 June 2026
- Published by University of Banja Luka, Faculty of Architecture, Civil Engineering and Geodesy
- Vol. 17 (1) , 38-47
Open AccessASSESSMENT OF DAYLIGHT AVAILABILITY IN AN EDUCATIONAL BUILDING
This study analyses daylight availability in a faculty lecture classroom using illuminance measurements and a survey of students. The results of the measurements conducted in mid-February showed that the recommended horizontal illuminance level (300 lx) was achieved at 50% of the measurement points around midday (12:00 h and 14:00 h), while only 0–15% of the area met this requirement at 8:00 h and 16:00 h. The minimum illuminance level (100 lx) was satisfied at all measurement points around midday but decreased to 25–45% in the early morning and late afternoon. Survey results indicated that 76.7% of students reported the need for artificial lighting during the winter period. Since natural daylight is sufficient during certain periods of the day, optimisation of the lighting system and the integration of controlled sensors for supplementary lighting are recommended.
- Open Access
- 1 January 2025
- Published by Scientific-Professional Society for Disaster Risk Management
- p. 66-74
Analysis of Air Comfort of Students in Lecture Rooms in University Buildings from the 1960s and 2020s
- 1 January 2025
- Published by Scientific-Professional Society for Disaster Risk Management
- p. 66-74
Open AccessAnalysis of Air Comfort of Students in Lecture Rooms in University Buildings from the 1960s and 2020s