MWManfred Wanner

Manfred Wanner

*This is an algorithmically generated author record based on publicly available information.

Manfred Wanner has a total of 58 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Improvement of the Quench Detection System for the PF Coils of JT-60SA

    by Shogo Sonoda, Haruyuki Murakami, Katsutomi Usui, Shoichi Hatakeyama, Kazuya Hamada, Sam Davis, Manfred Wanner, Valerio Tomarchio, Louis Zani, Guy Phillips, et al.

    The JT-60SA superconducting coil system comprises 6 Equilibrium Field coils, 4 Central Solenoid modules, and 18 Toroidal Field coils. Detecting a quench correctly in superconducting coils is essential to avoid damage of the coil. During the last integrated commissioning test, spike-shaped voltage fluctuations were observed on the EF and CS quench detection (QD) voltages. The voltage fluctuations occurred when the currents in the EF and CS coils rapidly changed. Following a circuit analysis of the EF coils, it was found that the spike voltage originated at the input of the QD differential amplifier from a slight mismatch of the time constants of the resistance-capacitance (RC) noise filter circuit. The RC filter circuit had to be adjusted precisely to achieve the same time constant between the winding and the pickup coil. The reduction of spike noise was experimentally confirmed by adjusting the variable capacitor or resistor in the filter circuit.

  • Development of the Protection System for JT-60SA Superconducting Magnet Against Vacuum Degradation

    by K. Fukui, V. Tomarchio, A. Jokinen, S. Davis, E. Di Pietro, G. Phillips, M. Wanner, Y. Shibama, K. Hamada

    The JT-60SA project succeeded in commissioning test toward the first plasma in 2023 under a framework: the Satellite Tokamak Programme of the Broader Approach Agreement between EU and Japan (H. Shirai et al., 2016). JT-60SA is a tokamak type magnetic confinement device with a superconducting magnet system (Y. Koide et al., 2015) developed and operated at the Quantum Science and Technology institute (QST) in Japan. The magnet system consists of 18 Toroidal Field coils, 6 Equilibrium Field coils, and 4 modules of Central Solenoids, and all the coils are superconducting magnets. In the first commissioning, during 2020 - 2021, JT-60SA has experienced a discharge incident at the EF1 magnet (H. Shirai et al., 2024). As a conclusion of the investigation of the incident, it turned out that the insulation resistance of the magnet system was insufficient. Although the insulation was partly reinforced, the voltage holding under accidentally arising Paschen conditions was not improved enough for the recent operation (OP-1, 2023) (K. Hamada et al., 2024). To prevent the magnet system from discharging during vacuum degradation, a vacuum monitoring system must be prepared to detect vacuum degradation and ramp down the magnet current immediately in case of unexpected vacuum degradation. In this article, the development of the vacuum monitoring system, operational results, and the future plan of the system will be described.


  • Extended Analysis of TF02 Feeder Performance and Risks During Operation in JT-60SA Tokamak

    by L. Zani, R. Babouche, P. Barabaschi, F. Cau, S. Davis, E. Di Pietro, H. Hurzlmeier, J. Lorenzo, A. Louzguiti, M. Lungu, et al.

    The upgrade to JT-60SA tokamak (R = 3 m, a = 1.2 m) was conducted within a Europe-Japan collaboration agreement featuring the implementation of superconducting magnets. In 2021, the magnet system commissioning was initiated, undergoing cool-down and energization of the 18 Nb-Ti Toroidal Field (TF) coils (400 tonnes) up to full nominal current. TF energization was smoothly processed but it was observed during current load a higher outlet temperature increase of TF02 coil versus others, indicating a higher resistance in this coil circuit and therefore a possible risk in future operation. The present paper analyses the different risk factors that can impact the TF operation safety margins and their quantitative contribution. To this end on the one hand ad-hoc thermal & thermo-hydraulic models were developed by CEA and F4E to represent the TF02 whole circuit including feeder zone where high resistance is suspected to be located. The outcomes of those models on chosen TF and PF current scenarios including transient loads and their impact on temperature margin in risky zones such as terminal joint (TJ) are presented. On the another hand a 3D electrical circuit of TJ was modelled using TF cables tomography, giving a realistic quantitative insight into local current distribution, therefore on current sharing temperature. The analyses outcomes synthesis is depicted under strategic considerations and tentatively contributes to establishing guidelines for future operation scenarios in which magnets will undergo demanding conditions.


  • Lessons Learned From EF1 Electrical Short Incident During JT-60SA Integrated Commissioning Test

    by Kazuya Hamada, Haruyuki Murakami, Katsuhiko Tsuchiya, Katsumi Kawano, Kazuma Fukui, Yoshihiro Onishi, Mio Nakamoto, Hideki Kajitani, Atsushi Kojima, Akihiro Terakado, et al.

    The superconducting tokamak fusion test device, JT-60SA, was constructed as the Satellite Tokamak project in the Broader Approach Program between Japan and EU. During the JT-60SA integrated commissioning tests of the Nb-Ti equilibrium magnetic field coil EF1 high voltage (∼5 kV) test, the EF1 power supply current surged suddenly and was stopped by the overcurrent interlock of the power supply. At the same time, the vacuum in the cryostat deteriorated, and the pressure in the magnet cooling loops increased. After the system warmed up, visual inspection revealed that discharges occurred between ground and both positive and negative terminal joints of EF1. Several holes, melted by the electrical short and identified as the source of the helium leak into the cryostat, were found in the cylindrical metal part of the joint. The data recorded at the time of the event were analyzed with a conclusion that the discharge first occurred between the positive terminal joint and its support bracket at ground potential and immediately afterward between the neighboring negative terminal joint and its support bracket. These two arcs created a short-circuited loop through which the coil discharged for about 1.4 s. The energy during the short circuit is estimated to be about 60 kJ.


  • AC Losses in JT-60SA TF Magnet During Commissioning: Experimental Analysis and Modeling

    by A. Louzguiti, S. Davis, K. Fukui, K. Hamada, C. Hoa, B. Lacroix, Q. Le Coz, F. Michel, H. Murakami, S. Nicollet, et al.

    During the integrated commissioning of JT-60SA tokamak, the Toroidal Field (TF) magnet has experienced fast current discharges which have induced AC losses in its winding packs (WP) and in its casings. Using the thermo-hydraulic sensors network installed at the inlet and outlet of the TF coils, we have performed enthalpy balances to estimate the transient heat loads generated by AC losses. In parallel, we have modeled the hysteresis and coupling losses produced in the WP and the eddy currents losses produced in the casings by such events. We then assess and discuss the consistency between these experimental and first theoretical analyses from the energy balance point of view.


  • Pressure Drop Measurement of the JT-60SA Superconducting Magnets

    by K. Fukui, K. Hamada, K. Natsume, H. Murakami, K. Tsuchiya, K. Kawano, K. Otsu, T. Abe, M. Wanner, V. Tomarchio, et al.

    The full-supercond ucting tokamak JT-60 Super Advanced (JT-60SA) has been constructed under the JA-EU Broader Approach agreement (Fukui et al. , 2019). The construction was completed in March 2020 followed by the first cool down operation. The magnet system used in JT-60SA consists of 18 toroidal field (TF) coils, 6 equilibrium field (EF) coils and 4 modules of central solenoid (CS) (Fukui et al. , 2020). All magnets are cooled by a forced flow of helium (Hoa et al. , 2012). During cool down uniform magnet temperatures are necessary. However, helium flow is difficult to be distributed accurately for each magnet, because the flow characteristics of each magnet are different. The objective of this work is to investigate the flow characteristics of all magnets in preparation for the next cool down operation.


  • Open Access

    Transformation of electrical energy into hydrogen and its storage

    by Manfred Wanner

    The German national hydrogen strategy strongly supports the development of technologies to produce, store and distribute green hydrogen in large quantities to reduce greenhouse gas emissions. In the public debate, it is often argued that the economic success of green hydrogen depends primarily on improved efficiencies, and reduced plant costs over large volumes and higher capacities. However, an economy based on the large-scale use of green hydrogen must also take into account the thermodynamic and technical limitations of the processes and components. This study therefore aims to assess the main technical challenges of the German approach to the large-scale use green hydrogen as a future energy carrier.


  • Open Access

    Cryogenic system for the JT-60SA superconducting tokamak Thermal analysis during coil energization test

    by Hamada Kazuya, Fukui Kazuma, Kawano Katsumi, Natsume Kyohei, Onishi Yoshihiro, Ohtsu Kiichi, Michel Frederic, Hoa Christine, Wanner Manfred

    The JT-60SA cryogenic system with a refrigeration capacity of 9.5 kW at 4.5 K consists of Refrigerator Cold Box (RCB) and Auxiliary Cold Box(ACB). The RCB provides cold helium to the ACB, high-temperature superconductor current leads, and an 80 K thermal shield. The ACB supplies supercritical helium at 4.4 K / 0.5 MPa by cold helium circulation pumps to a superconducting magnet system through the heat exchangers in a liquid helium tank. In a tokamak type fusion device, superconducting coils, CS and EF, are operated as dynamically controlling their transport currents to sustain plasma operation. Hence the heat load variations caused by AC losses could disturb the operation of the cryogenic system. The JT-60SA cryogenic system has an active control mechanism to mitigate a substantial dynamic of heat load for the stable operation of the warm helium compressors and turbines. During the commissioning of the cryogenic system, the active control mechanism demonstrated a stable operation of the cryogenic system. A cool-down operation of the cryogenic system started in October 2020. This paper reports the specifications of the cryogenic system, a result from a control test for variable heat load, and thermal analysis result at toroidal field coil operation.


  • Space qualification of the ISO cryogenic rupture discs

    by E. Ettlinger, H. Rüdiger, M. Wanner