Valerio Tomarchio
Valerio Tomarchio has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Kazuya Hamada
National Institutes for Quantum Science and Technology, Naka, Japan
5 shared publications - Manfred Wanner
Fusion for Energy, Garching, Germany
5 shared publications - Sam Davis
Fusion for Energy, Garching, Germany
5 shared publications - Enrico di Pietro
Fusion for Energy, Torres Diagonal Litoral Edificio, Barcelona, Spain
3 shared publications - Haruyuki Murakami
National Institutes for Quantum Science and Technology, Naka, Japan
3 shared publications - Kazuma Fukui
National Institutes for Quantum and Radiological Science and Technology, Naka, Japan
3 shared publications
Latest Publications
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-4
Improvement of the Quench Detection System for the PF Coils of JT-60SA
The JT-60SA superconducting coil system comprises 6 Equilibrium Field coils, 4 Central Solenoid modules, and 18 Toroidal Field coils. Detecting a quench correctly in superconducting coils is essential to avoid damage of the coil. During the last integrated commissioning test, spike-shaped voltage fluctuations were observed on the EF and CS quench detection (QD) voltages. The voltage fluctuations occurred when the currents in the EF and CS coils rapidly changed. Following a circuit analysis of the EF coils, it was found that the spike voltage originated at the input of the QD differential amplifier from a slight mismatch of the time constants of the resistance-capacitance (RC) noise filter circuit. The RC filter circuit had to be adjusted precisely to achieve the same time constant between the winding and the pickup coil. The reduction of spike noise was experimentally confirmed by adjusting the variable capacitor or resistor in the filter circuit.
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-4
Improvement of the Quench Detection System for the PF Coils of JT-60SA
The JT-60SA superconducting coil system comprises 6 Equilibrium Field coils, 4 Central Solenoid modules, and 18 Toroidal Field coils. Detecting a quench correctly in superconducting coils is essential to avoid damage of the coil. During the last integrated commissioning test, spike-shaped voltage fluctuations were observed on the EF and CS quench detection (QD) voltages. The voltage fluctuations occurred when the currents in the EF and CS coils rapidly changed. Following a circuit analysis of the EF coils, it was found that the spike voltage originated at the input of the QD differential amplifier from a slight mismatch of the time constants of the resistance-capacitance (RC) noise filter circuit. The RC filter circuit had to be adjusted precisely to achieve the same time constant between the winding and the pickup coil. The reduction of spike noise was experimentally confirmed by adjusting the variable capacitor or resistor in the filter circuit.
- 23 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-7
Magnet Commissioning on the World's Biggest Operating Tokamak JT-60SA
JT-60SA is the world's biggest operating tokamak (R = 3, a = 1.2) having achieved a plasma volume of 160m3 in 2023. As the first of a new generation of large fusion experimental machines, its commissioning represents a unique opportunity to gain invaluable operational experience. The magnets form the backbone of any tokamak, and the superconducting magnet systems of JT-60SA play a critical role in allowing long pulse operation, essential for studying plasma behaviour in conditions relevant to reactor operation. The novel design of the NbTi Toroidal Field (TF) magnet, providing the main confinement field for the plasma, allows its 18 coils (each 7.5 m high) to expand radially when energized within their Outer Intercoil Structures, which in turn provide lateral support. The 100-tonne Nb3Sn Central Solenoid (CS) is key to driving current in the plasma while the six NbTi Equilibrium Field (EF) coils, up to 12m in diameter, shape and control it. The TF magnet was successfully operated at its full 2.25 T on-axis field in 2021, and in October 2023 all the magnets could be operated together to produce the first tokamak plasma. While individual components - such as a coils, power supplies or cryoplants - can be thoroughly tested in isolation, many critical aspects of their interaction can only be assessed during integrated commissioning, where all systems are operated together. This paper provides an overview of the magnet system integrated commissioning process and highlights key lessons learned, particularly regarding insulation integrity, Paschen testing, applied voltages, power circuit design, and quench detection.
- 23 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-7
Magnet Commissioning on the World's Biggest Operating Tokamak JT-60SA
JT-60SA is the world's biggest operating tokamak (R = 3, a = 1.2) having achieved a plasma volume of 160m3 in 2023. As the first of a new generation of large fusion experimental machines, its commissioning represents a unique opportunity to gain invaluable operational experience. The magnets form the backbone of any tokamak, and the superconducting magnet systems of JT-60SA play a critical role in allowing long pulse operation, essential for studying plasma behaviour in conditions relevant to reactor operation. The novel design of the NbTi Toroidal Field (TF) magnet, providing the main confinement field for the plasma, allows its 18 coils (each 7.5 m high) to expand radially when energized within their Outer Intercoil Structures, which in turn provide lateral support. The 100-tonne Nb3Sn Central Solenoid (CS) is key to driving current in the plasma while the six NbTi Equilibrium Field (EF) coils, up to 12m in diameter, shape and control it. The TF magnet was successfully operated at its full 2.25 T on-axis field in 2021, and in October 2023 all the magnets could be operated together to produce the first tokamak plasma. While individual components - such as a coils, power supplies or cryoplants - can be thoroughly tested in isolation, many critical aspects of their interaction can only be assessed during integrated commissioning, where all systems are operated together. This paper provides an overview of the magnet system integrated commissioning process and highlights key lessons learned, particularly regarding insulation integrity, Paschen testing, applied voltages, power circuit design, and quench detection.
- 11 April 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 216
Thermal structural analyses during cool down of the ITER toroidal field coil in the magnet cold test bench
- 11 April 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 216
Thermal structural analyses during cool down of the ITER toroidal field coil in the magnet cold test bench
- 13 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Development of the Protection System for JT-60SA Superconducting Magnet Against Vacuum Degradation
The JT-60SA project succeeded in commissioning test toward the first plasma in 2023 under a framework: the Satellite Tokamak Programme of the Broader Approach Agreement between EU and Japan (H. Shirai et al., 2016). JT-60SA is a tokamak type magnetic confinement device with a superconducting magnet system (Y. Koide et al., 2015) developed and operated at the Quantum Science and Technology institute (QST) in Japan. The magnet system consists of 18 Toroidal Field coils, 6 Equilibrium Field coils, and 4 modules of Central Solenoids, and all the coils are superconducting magnets. In the first commissioning, during 2020 - 2021, JT-60SA has experienced a discharge incident at the EF1 magnet (H. Shirai et al., 2024). As a conclusion of the investigation of the incident, it turned out that the insulation resistance of the magnet system was insufficient. Although the insulation was partly reinforced, the voltage holding under accidentally arising Paschen conditions was not improved enough for the recent operation (OP-1, 2023) (K. Hamada et al., 2024). To prevent the magnet system from discharging during vacuum degradation, a vacuum monitoring system must be prepared to detect vacuum degradation and ramp down the magnet current immediately in case of unexpected vacuum degradation. In this article, the development of the vacuum monitoring system, operational results, and the future plan of the system will be described.
- 13 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Development of the Protection System for JT-60SA Superconducting Magnet Against Vacuum Degradation
The JT-60SA project succeeded in commissioning test toward the first plasma in 2023 under a framework: the Satellite Tokamak Programme of the Broader Approach Agreement between EU and Japan (H. Shirai et al., 2016). JT-60SA is a tokamak type magnetic confinement device with a superconducting magnet system (Y. Koide et al., 2015) developed and operated at the Quantum Science and Technology institute (QST) in Japan. The magnet system consists of 18 Toroidal Field coils, 6 Equilibrium Field coils, and 4 modules of Central Solenoids, and all the coils are superconducting magnets. In the first commissioning, during 2020 - 2021, JT-60SA has experienced a discharge incident at the EF1 magnet (H. Shirai et al., 2024). As a conclusion of the investigation of the incident, it turned out that the insulation resistance of the magnet system was insufficient. Although the insulation was partly reinforced, the voltage holding under accidentally arising Paschen conditions was not improved enough for the recent operation (OP-1, 2023) (K. Hamada et al., 2024). To prevent the magnet system from discharging during vacuum degradation, a vacuum monitoring system must be prepared to detect vacuum degradation and ramp down the magnet current immediately in case of unexpected vacuum degradation. In this article, the development of the vacuum monitoring system, operational results, and the future plan of the system will be described.
- 12 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Extended Analysis of TF02 Feeder Performance and Risks During Operation in JT-60SA Tokamak
The upgrade to JT-60SA tokamak (R = 3 m, a = 1.2 m) was conducted within a Europe-Japan collaboration agreement featuring the implementation of superconducting magnets. In 2021, the magnet system commissioning was initiated, undergoing cool-down and energization of the 18 Nb-Ti Toroidal Field (TF) coils (400 tonnes) up to full nominal current. TF energization was smoothly processed but it was observed during current load a higher outlet temperature increase of TF02 coil versus others, indicating a higher resistance in this coil circuit and therefore a possible risk in future operation. The present paper analyses the different risk factors that can impact the TF operation safety margins and their quantitative contribution. To this end on the one hand ad-hoc thermal & thermo-hydraulic models were developed by CEA and F4E to represent the TF02 whole circuit including feeder zone where high resistance is suspected to be located. The outcomes of those models on chosen TF and PF current scenarios including transient loads and their impact on temperature margin in risky zones such as terminal joint (TJ) are presented. On the another hand a 3D electrical circuit of TJ was modelled using TF cables tomography, giving a realistic quantitative insight into local current distribution, therefore on current sharing temperature. The analyses outcomes synthesis is depicted under strategic considerations and tentatively contributes to establishing guidelines for future operation scenarios in which magnets will undergo demanding conditions.
- 12 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Extended Analysis of TF02 Feeder Performance and Risks During Operation in JT-60SA Tokamak
The upgrade to JT-60SA tokamak (R = 3 m, a = 1.2 m) was conducted within a Europe-Japan collaboration agreement featuring the implementation of superconducting magnets. In 2021, the magnet system commissioning was initiated, undergoing cool-down and energization of the 18 Nb-Ti Toroidal Field (TF) coils (400 tonnes) up to full nominal current. TF energization was smoothly processed but it was observed during current load a higher outlet temperature increase of TF02 coil versus others, indicating a higher resistance in this coil circuit and therefore a possible risk in future operation. The present paper analyses the different risk factors that can impact the TF operation safety margins and their quantitative contribution. To this end on the one hand ad-hoc thermal & thermo-hydraulic models were developed by CEA and F4E to represent the TF02 whole circuit including feeder zone where high resistance is suspected to be located. The outcomes of those models on chosen TF and PF current scenarios including transient loads and their impact on temperature margin in risky zones such as terminal joint (TJ) are presented. On the another hand a 3D electrical circuit of TJ was modelled using TF cables tomography, giving a realistic quantitative insight into local current distribution, therefore on current sharing temperature. The analyses outcomes synthesis is depicted under strategic considerations and tentatively contributes to establishing guidelines for future operation scenarios in which magnets will undergo demanding conditions.
- 27 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Lessons Learned From EF1 Electrical Short Incident During JT-60SA Integrated Commissioning Test
The superconducting tokamak fusion test device, JT-60SA, was constructed as the Satellite Tokamak project in the Broader Approach Program between Japan and EU. During the JT-60SA integrated commissioning tests of the Nb-Ti equilibrium magnetic field coil EF1 high voltage (∼5 kV) test, the EF1 power supply current surged suddenly and was stopped by the overcurrent interlock of the power supply. At the same time, the vacuum in the cryostat deteriorated, and the pressure in the magnet cooling loops increased. After the system warmed up, visual inspection revealed that discharges occurred between ground and both positive and negative terminal joints of EF1. Several holes, melted by the electrical short and identified as the source of the helium leak into the cryostat, were found in the cylindrical metal part of the joint. The data recorded at the time of the event were analyzed with a conclusion that the discharge first occurred between the positive terminal joint and its support bracket at ground potential and immediately afterward between the neighboring negative terminal joint and its support bracket. These two arcs created a short-circuited loop through which the coil discharged for about 1.4 s. The energy during the short circuit is estimated to be about 60 kJ.
- 27 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Lessons Learned From EF1 Electrical Short Incident During JT-60SA Integrated Commissioning Test
The superconducting tokamak fusion test device, JT-60SA, was constructed as the Satellite Tokamak project in the Broader Approach Program between Japan and EU. During the JT-60SA integrated commissioning tests of the Nb-Ti equilibrium magnetic field coil EF1 high voltage (∼5 kV) test, the EF1 power supply current surged suddenly and was stopped by the overcurrent interlock of the power supply. At the same time, the vacuum in the cryostat deteriorated, and the pressure in the magnet cooling loops increased. After the system warmed up, visual inspection revealed that discharges occurred between ground and both positive and negative terminal joints of EF1. Several holes, melted by the electrical short and identified as the source of the helium leak into the cryostat, were found in the cylindrical metal part of the joint. The data recorded at the time of the event were analyzed with a conclusion that the discharge first occurred between the positive terminal joint and its support bracket at ground potential and immediately afterward between the neighboring negative terminal joint and its support bracket. These two arcs created a short-circuited loop through which the coil discharged for about 1.4 s. The energy during the short circuit is estimated to be about 60 kJ.
- 23 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
Pressure Drop Measurement of the JT-60SA Superconducting Magnets
The full-supercond ucting tokamak JT-60 Super Advanced (JT-60SA) has been constructed under the JA-EU Broader Approach agreement (Fukui et al. , 2019). The construction was completed in March 2020 followed by the first cool down operation. The magnet system used in JT-60SA consists of 18 toroidal field (TF) coils, 6 equilibrium field (EF) coils and 4 modules of central solenoid (CS) (Fukui et al. , 2020). All magnets are cooled by a forced flow of helium (Hoa et al. , 2012). During cool down uniform magnet temperatures are necessary. However, helium flow is difficult to be distributed accurately for each magnet, because the flow characteristics of each magnet are different. The objective of this work is to investigate the flow characteristics of all magnets in preparation for the next cool down operation.
- 23 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
Pressure Drop Measurement of the JT-60SA Superconducting Magnets
The full-supercond ucting tokamak JT-60 Super Advanced (JT-60SA) has been constructed under the JA-EU Broader Approach agreement (Fukui et al. , 2019). The construction was completed in March 2020 followed by the first cool down operation. The magnet system used in JT-60SA consists of 18 toroidal field (TF) coils, 6 equilibrium field (EF) coils and 4 modules of central solenoid (CS) (Fukui et al. , 2020). All magnets are cooled by a forced flow of helium (Hoa et al. , 2012). During cool down uniform magnet temperatures are necessary. However, helium flow is difficult to be distributed accurately for each magnet, because the flow characteristics of each magnet are different. The objective of this work is to investigate the flow characteristics of all magnets in preparation for the next cool down operation.
- 6 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 27 (5) , 1-8
Broadband Electromagnetic Modeling of the Superconducting Toroidal Field Magnets of JT-60SA: Transient Simulation and Fault Detectability
The superconducting Toroidal Field (TF) magnets of JT-60SA are designed to conduct a 25.7 kA current to generate a steady magnetic field for plasma confinement. In case of loss of their superconductive status, a Fast Discharge of the current is operated and the TF magnets are subjected to electromagnetic transient phenomena in a range of frequencies up to several tens of kHz. The TF coils show an involved frequency dependent behavior as a consequence of eddy currents induced in the casing, stray capacitances as well as electrical skin-effect in the jacket enclosing the strands, therefore electrical models derived considering the coil characteristics at a single frequency may not be suitable to perform reliable analyses of the Fast Discharge event. A broadband electromagnetic model was generated and validated against experimental data. Such a model can reproduce with sufficient accuracy the behavior of the TF magnets in the frequency range of interest. This model was employed to simulate the transient of the voltage distribution inside the coils during a Fast Discharge and to evaluate the maximum voltage difference between adjacent turns. The model was also employed to make predictions about the detectability of internal short-circuit in a coil by means of impedance spectrum measurements. It was possible to conclude that the highest sensitivity to short circuits can be achieved looking for impedance variations in proximity of the anti-resonant frequency.
- 6 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 27 (5) , 1-8
Broadband Electromagnetic Modeling of the Superconducting Toroidal Field Magnets of JT-60SA: Transient Simulation and Fault Detectability
The superconducting Toroidal Field (TF) magnets of JT-60SA are designed to conduct a 25.7 kA current to generate a steady magnetic field for plasma confinement. In case of loss of their superconductive status, a Fast Discharge of the current is operated and the TF magnets are subjected to electromagnetic transient phenomena in a range of frequencies up to several tens of kHz. The TF coils show an involved frequency dependent behavior as a consequence of eddy currents induced in the casing, stray capacitances as well as electrical skin-effect in the jacket enclosing the strands, therefore electrical models derived considering the coil characteristics at a single frequency may not be suitable to perform reliable analyses of the Fast Discharge event. A broadband electromagnetic model was generated and validated against experimental data. Such a model can reproduce with sufficient accuracy the behavior of the TF magnets in the frequency range of interest. This model was employed to simulate the transient of the voltage distribution inside the coils during a Fast Discharge and to evaluate the maximum voltage difference between adjacent turns. The model was also employed to make predictions about the detectability of internal short-circuit in a coil by means of impedance spectrum measurements. It was possible to conclude that the highest sensitivity to short circuits can be achieved looking for impedance variations in proximity of the anti-resonant frequency.