Ali Moussavi Zarandi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ali Moussavi Zarandi has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Ali Taheri
Nuclear Science and Technology Research Institute, Tehran, Iran
1 shared publication F. Payervand
Nuclear science and Technology Research Institute (NSTRI), Radiation application research school, Tehran, Iran
1 shared publicationMahdi Kafaee
Amirkabir University of Technology
1 shared publication- Mahdi Kafaee
Faculty of Electrical Engineering, Shahrood University of Technology, Shahrood, Iran
1 shared publication - Mostafa Hassanzadeh
Nuclear Science & Technology Research Institute, AEOI, Tehran, Iran
1 shared publication R. Noushinmehr
Nuclear Engineering and Physics Faculty, Amirkabir University of Technology, Tehran, Iran
1 shared publication
Latest Publications
- Open Access
- 15 September 2018
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 51 (1) , 293-302
Simulation and design of individual neutron dosimeter and optimization of energy response using an array of semiconductor sensors
- 15 September 2018
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 51 (1) , 293-302
Open AccessSimulation and design of individual neutron dosimeter and optimization of energy response using an array of semiconductor sensors
- 19 April 2016
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 68 (8) , 960-964
Baseline restoration and pile-up correction based on bipolar cusp-like shaping for high-resolution radiation spectroscopy
- 19 April 2016
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 68 (8) , 960-964
Baseline restoration and pile-up correction based on bipolar cusp-like shaping for high-resolution radiation spectroscopy
- 3 March 2016
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 171 (3-4) , 271-278
Neural-based pile-up correction and ballistic deficit correction of X-ray semiconductor detectors using the Monte Carlo simulation and the Ramo theorem
Pile-up distortion is a common problem in many nuclear radiation detection systems, especially in high count rates. It can be solved by hardware-based pile-up rejections, but there is no complete pile-up elimination in this way. Additionally, the methods can lead to poor quantitative results. Generally, time characteristics of semiconductor detector pulses are different from Scintillator detector pulses due to ballistic deficit. Hence, pulse processing-based pile-up correction in the detectors should consider this specification. In this paper, the artificial neural network pile-up correction method is applied for silicon detector piled-up pulses. For this purpose, the interaction of photons with a silicon detector is simulated by the MCNP4c code and the pulse current is calculated by Ramo's theorem. In this approach, we use a sub-Nyquist frequency sampling. The results show that the proposed method is reliable for pile-up correction and ballistic deficit in semiconductor detectors. The technique is remarkable for commercial considerations and high-speed, real-time calculations.
- 3 March 2016
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 171 (3-4) , 271-278
Neural-based pile-up correction and ballistic deficit correction of X-ray semiconductor detectors using the Monte Carlo simulation and the Ramo theorem
Pile-up distortion is a common problem in many nuclear radiation detection systems, especially in high count rates. It can be solved by hardware-based pile-up rejections, but there is no complete pile-up elimination in this way. Additionally, the methods can lead to poor quantitative results. Generally, time characteristics of semiconductor detector pulses are different from Scintillator detector pulses due to ballistic deficit. Hence, pulse processing-based pile-up correction in the detectors should consider this specification. In this paper, the artificial neural network pile-up correction method is applied for silicon detector piled-up pulses. For this purpose, the interaction of photons with a silicon detector is simulated by the MCNP4c code and the pulse current is calculated by Ramo's theorem. In this approach, we use a sub-Nyquist frequency sampling. The results show that the proposed method is reliable for pile-up correction and ballistic deficit in semiconductor detectors. The technique is remarkable for commercial considerations and high-speed, real-time calculations.
- 1 December 2008
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 66 (12) , 1830-1833
Determination of D2O by photoneutron activation techniques
- 1 December 2008
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 66 (12) , 1830-1833
Determination of D2O by photoneutron activation techniques
- 1 February 2008
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 66 (2) , 158-161
Determination of beryllium by use of photonuclear activation techniques
- 1 February 2008
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 66 (2) , 158-161
Determination of beryllium by use of photonuclear activation techniques