Hongyun Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hongyun Wang has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Cheng Bi
School of Intelligent Manufacture, Taizhou University, Taizhou, China
8 shared publications- Cheng Bi
School of Intelligent Manufacture, Taizhou University, Taizhou 318000, China
5 shared publications Axiang Ji
School of Intelligent Manufacture, Taizhou University, Taizhou, China
4 shared publicationsChunfu Gao
College of Mechanical Engineering, Zhejiang Normal University, Jinhua, China
2 shared publicationsErda Bi
HD Ningbo School, Ningbo, China
2 shared publicationsFenfen Zhou
School of Intelligent Manufacture, Taizhou University, Taizhou, China
2 shared publications
Latest Publications
- Open Access
Roller-Type Ultrasonic-Assisted Magnetorheological Finishing for Medical Ti-6Al-4V Miniature Screws: Mechanism, Device Design, and Process Optimization
Ti-6Al-4V miniature screws are widely used in medical implants, where surface quality strongly affects biocompatibility and service life. However, their threaded geometry, small radius of curvature, and poor machinability make high-quality finishing difficult. To address this challenge, a roller-type ultrasonic-assisted magnetorheological finishing (R-UMRF) process was proposed for Ti-6Al-4V miniature screws (M2.5 × 4 mm). A three-pole magnetic field generator was designed and optimized by finite element analysis to establish a stable finishing zone and a weak-field renewal zone for flexible-brush regeneration. Guided by the process mechanism, single-factor experiments were first performed to evaluate the effects of finishing time, spindle speed, roller speed, ultrasonic amplitude, and applied current on surface roughness (Ra). A four-factor, three-level orthogonal experiment was then conducted to optimize Ra and the change rate of surface roughness (ΔRa). The applied current showed the strongest effect on finishing performance, followed by roller speed; however, excessive current or ultrasonic amplitude deteriorated the surface because of over-aggressive abrasive action. The optimal parameters were a spindle speed of 260 r/min, a roller speed of 140 r/min, an ultrasonic amplitude of 10 μm, and an applied current of 4 A. Under these conditions, Ra decreased from 1.208 μm to 0.081 μm after 120 min, corresponding to a reduction of 93.29%. These results demonstrate that R-UMRF is an effective low-damage finishing method for Ti-6Al-4V miniature screws with complex threaded surfaces.
Open AccessRoller-Type Ultrasonic-Assisted Magnetorheological Finishing for Medical Ti-6Al-4V Miniature Screws: Mechanism, Device Design, and Process Optimization
Ti-6Al-4V miniature screws are widely used in medical implants, where surface quality strongly affects biocompatibility and service life. However, their threaded geometry, small radius of curvature, and poor machinability make high-quality finishing difficult. To address this challenge, a roller-type ultrasonic-assisted magnetorheological finishing (R-UMRF) process was proposed for Ti-6Al-4V miniature screws (M2.5 × 4 mm). A three-pole magnetic field generator was designed and optimized by finite element analysis to establish a stable finishing zone and a weak-field renewal zone for flexible-brush regeneration. Guided by the process mechanism, single-factor experiments were first performed to evaluate the effects of finishing time, spindle speed, roller speed, ultrasonic amplitude, and applied current on surface roughness (Ra). A four-factor, three-level orthogonal experiment was then conducted to optimize Ra and the change rate of surface roughness (ΔRa). The applied current showed the strongest effect on finishing performance, followed by roller speed; however, excessive current or ultrasonic amplitude deteriorated the surface because of over-aggressive abrasive action. The optimal parameters were a spindle speed of 260 r/min, a roller speed of 140 r/min, an ultrasonic amplitude of 10 μm, and an applied current of 4 A. Under these conditions, Ra decreased from 1.208 μm to 0.081 μm after 120 min, corresponding to a reduction of 93.29%. These results demonstrate that R-UMRF is an effective low-damage finishing method for Ti-6Al-4V miniature screws with complex threaded surfaces.
- Open Access
- 23 April 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-13
Improvement of roughness in ultrasonic assisted magnetorheological finishing of small titanium alloy nuts by orthogonal test method
Titanium alloy with high corrosion resistance, high strength-to-density ratio, and excellent biocompatibility has a wide range of applications in the field of biomedical implants. Polishing experiments of titanium alloy with a small size and complex shapes were investigated using an ultrasonic assisted magnetorheological finishing (UMRF) device excited by a three-pole magnetic field generator. The models of the normal force and the shear force were first proposed based on the Preston equation to analyze the mechanism of material removal in the UMRF process. Subsequently, the single-factor experiments using titanium alloy nuts (M3) and the MR polishing fluid with silicon carbide abrasives were carried out. Furthermore, to improve the surface roughness and the change rate of surface roughness of nuts, orthogonal tests with a standard L9(34) orthogonal array were designed and performed based on the optimized process parameters obtained from the single-factor experiment. The results indicated the effect on surface roughness and change rate of surface roughness as applied current > roller speed > ultrasonic amplitude > spindle speed and applied current > roller speed > spindle speed > ultrasonic amplitude, respectively. Moreover, the surface roughness was improved from an initial 1.247 μm to a final 0.104 μm after the polishing for 80 min under these optimal process parameters.
- 23 April 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-13
Open AccessImprovement of roughness in ultrasonic assisted magnetorheological finishing of small titanium alloy nuts by orthogonal test method
Titanium alloy with high corrosion resistance, high strength-to-density ratio, and excellent biocompatibility has a wide range of applications in the field of biomedical implants. Polishing experiments of titanium alloy with a small size and complex shapes were investigated using an ultrasonic assisted magnetorheological finishing (UMRF) device excited by a three-pole magnetic field generator. The models of the normal force and the shear force were first proposed based on the Preston equation to analyze the mechanism of material removal in the UMRF process. Subsequently, the single-factor experiments using titanium alloy nuts (M3) and the MR polishing fluid with silicon carbide abrasives were carried out. Furthermore, to improve the surface roughness and the change rate of surface roughness of nuts, orthogonal tests with a standard L9(34) orthogonal array were designed and performed based on the optimized process parameters obtained from the single-factor experiment. The results indicated the effect on surface roughness and change rate of surface roughness as applied current > roller speed > ultrasonic amplitude > spindle speed and applied current > roller speed > spindle speed > ultrasonic amplitude, respectively. Moreover, the surface roughness was improved from an initial 1.247 μm to a final 0.104 μm after the polishing for 80 min under these optimal process parameters.
- Open Access
- 7 January 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-12
Magnetic circuit design for the performance experiment of shear yield stress enhanced by compression of magnetorheological fluids
The shear yield stress is an important parameter for the industrial application of magnetorheological (MR) fluids. A test equipment was designed and built to perform investigations on the behaviours of compression and shear after squeeze of MR fluids. Mathematical expression of magnetic flux density was further established. Furthermore, the magnetic field distribution of the test device based on two-coil mode and single-coil mode was simulated and compared using finite element analysis(ANSYS/Multiphysics). An experimental test system was fabricated and modified based on the final conditions and simulation results. The compression and shear after squeeze performances of MR fluids were tested. The results showed that a smaller initial gap distance or a larger compressive strain corresponds to a larger compressive stress under the same external magnetic field strength. The shear yield stress after the squeeze of MR fluids increases quickly with the increasing compression stress and the increasing magnetic flux density. This test equipment was thought to be suitable for studying the compression and shear after squeeze performances of MR fluids.
- 7 January 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-12
Open AccessMagnetic circuit design for the performance experiment of shear yield stress enhanced by compression of magnetorheological fluids
The shear yield stress is an important parameter for the industrial application of magnetorheological (MR) fluids. A test equipment was designed and built to perform investigations on the behaviours of compression and shear after squeeze of MR fluids. Mathematical expression of magnetic flux density was further established. Furthermore, the magnetic field distribution of the test device based on two-coil mode and single-coil mode was simulated and compared using finite element analysis(ANSYS/Multiphysics). An experimental test system was fabricated and modified based on the final conditions and simulation results. The compression and shear after squeeze performances of MR fluids were tested. The results showed that a smaller initial gap distance or a larger compressive strain corresponds to a larger compressive stress under the same external magnetic field strength. The shear yield stress after the squeeze of MR fluids increases quickly with the increasing compression stress and the increasing magnetic flux density. This test equipment was thought to be suitable for studying the compression and shear after squeeze performances of MR fluids.
- 11 July 2023
- Published by Elsevier in Materials Today Communications
- Vol. 36
Normalized structure parameter of magnetorheological fluids under unidirectional monotonous squeeze
- 11 July 2023
- Published by Elsevier in Materials Today Communications
- Vol. 36
Normalized structure parameter of magnetorheological fluids under unidirectional monotonous squeeze
- 2 June 2023
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 34 (19) , 2307-2318
An experimental study on mechanical properties of a magnetorheological fluid under slow compression
Mechanical properties of magnetorheological (MR) fluids have been investigated in slow compression under different magnetic fields. The compressive stress of the MR fluid has been deduced by assuming that it was a continuous shear flow in Bingham model and has been calculated. The compressive stress has also measured in different magnetic fields and initial gap distances. The compressive stress of the MR fluid in a high magnetic flux density and/or a small initial gap distance was much higher than that predicted by the traditional continuous media theory. Compressive experimental results were also compared with the continuous media theory by a normalized logarithmic form. The achieved experimental result seems to deviate from the prediction by the continuous media theory at a high magnetic flux density and a small initial gap distance. The MR fluid had a high compressive modulus when the compressive strain was lower than 0.042. The compressive modulus had an exponential relationship with the compressive strain higher than 0.042. Frictions between particles, which contribute to the high structure factor, were thought to play an important role in the large deviations in squeeze mode.
- 2 June 2023
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 34 (19) , 2307-2318
An experimental study on mechanical properties of a magnetorheological fluid under slow compression
Mechanical properties of magnetorheological (MR) fluids have been investigated in slow compression under different magnetic fields. The compressive stress of the MR fluid has been deduced by assuming that it was a continuous shear flow in Bingham model and has been calculated. The compressive stress has also measured in different magnetic fields and initial gap distances. The compressive stress of the MR fluid in a high magnetic flux density and/or a small initial gap distance was much higher than that predicted by the traditional continuous media theory. Compressive experimental results were also compared with the continuous media theory by a normalized logarithmic form. The achieved experimental result seems to deviate from the prediction by the continuous media theory at a high magnetic flux density and a small initial gap distance. The MR fluid had a high compressive modulus when the compressive strain was lower than 0.042. The compressive modulus had an exponential relationship with the compressive strain higher than 0.042. Frictions between particles, which contribute to the high structure factor, were thought to play an important role in the large deviations in squeeze mode.
- Open Access
Squeeze Behaviors of Magnetorheological Fluids under Different Compressive Speeds
The compression tests under the unidirection for magnetorheological (MR) fluids have been studied at different compressive speeds. The results indicated that curves of compressive stress under different compression speeds at the applied magnetic field of 0.15 T overlapped well and were shown to be an exponent of about 1 of the initial gap distance in the elastic deformation region and accorded well with the description of continuous media theory. The difference in compressive stress curves increases significantly with an increasing magnetic field. At this time, the continuous media theory description could not be accounted for the effect of compressive speed on the compression of MR fluid, which seems to deviate from the Deborah number prediction under the lower compressive speeds. An explanation based on the two-phase flow due to aggregations of particle chains resulting in much longer relaxation times at a lower compressive speed was proposed to explain this deviation. The results have guiding significance for the theoretical design and process parameter optimization for the squeeze-assisted MR devices such as MR dampers and MR clutches based on the compressive resistance.
Open AccessSqueeze Behaviors of Magnetorheological Fluids under Different Compressive Speeds
The compression tests under the unidirection for magnetorheological (MR) fluids have been studied at different compressive speeds. The results indicated that curves of compressive stress under different compression speeds at the applied magnetic field of 0.15 T overlapped well and were shown to be an exponent of about 1 of the initial gap distance in the elastic deformation region and accorded well with the description of continuous media theory. The difference in compressive stress curves increases significantly with an increasing magnetic field. At this time, the continuous media theory description could not be accounted for the effect of compressive speed on the compression of MR fluid, which seems to deviate from the Deborah number prediction under the lower compressive speeds. An explanation based on the two-phase flow due to aggregations of particle chains resulting in much longer relaxation times at a lower compressive speed was proposed to explain this deviation. The results have guiding significance for the theoretical design and process parameter optimization for the squeeze-assisted MR devices such as MR dampers and MR clutches based on the compressive resistance.
- Open Access
A Comparative Analysis of Measured and Calculated Compressive Stresses of Magnetorheological Fluids under Unidirectional Compression and Constant Area
Unidirectional compressive properties of magnetorheological (MR) fluids have been investigated under slow compression and constant area with different magnetic fields and different initial gap distances. Experimental tests of unidirectional compression were firstly carried out by using a commercial plate–plate rheometer. The theoretical model based on the continuous squeeze flow theory was developed to calculate the compressive stress. The comparisons between the measured and calculated compressive stresses of MR fluids were made. It showed that the compression resistance of the MR fluid in the magnetic field was much higher than that predicted by the theory. With the increasing magnetic flux density, the deviation between measured and calculated curves accelerated. Characteristics of the compressive stress variation with the reduction in gap distance have been analyzed. The structure strengthening effect induced by the chain structure aggregation in squeeze mode has been used to explain this deviation.
Open AccessA Comparative Analysis of Measured and Calculated Compressive Stresses of Magnetorheological Fluids under Unidirectional Compression and Constant Area
Unidirectional compressive properties of magnetorheological (MR) fluids have been investigated under slow compression and constant area with different magnetic fields and different initial gap distances. Experimental tests of unidirectional compression were firstly carried out by using a commercial plate–plate rheometer. The theoretical model based on the continuous squeeze flow theory was developed to calculate the compressive stress. The comparisons between the measured and calculated compressive stresses of MR fluids were made. It showed that the compression resistance of the MR fluid in the magnetic field was much higher than that predicted by the theory. With the increasing magnetic flux density, the deviation between measured and calculated curves accelerated. Characteristics of the compressive stress variation with the reduction in gap distance have been analyzed. The structure strengthening effect induced by the chain structure aggregation in squeeze mode has been used to explain this deviation.
- Open Access
- 9 June 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-12
Transient behavior of compressed magnetorheological brake excited by step currents
Transient behavior of a magnetorheological brake excited by step currents under compression-shear mode has been experimentally studied. The results show that the amplitude of the applied current had little effect on the rising time of transient torque, while the rising time was significantly affected by the rotational speed, the compressive speed and the compressive strain position. The falling time of transient torque was independent of the amplitude of the applied current, the compressive speed and the compressive strain position, and it was affected by the rotational speed. The falling time of the transient torque was much shorter than the rising time by a step current. The transient process of MR brake applied as a step current was different from a stable process pre-applied at constant current in different particle chain structure forming processes. In addition, the compressive processes applied in one step current and randomly on/off current were compared and experimentally verified: the particle chains in two processes both experienced the same evolutionary of transient torque. The results achieved in this study should be properly considered in the design and control of magnetorheological brake under compression-shear mode.
- 9 June 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-12
Open AccessTransient behavior of compressed magnetorheological brake excited by step currents
Transient behavior of a magnetorheological brake excited by step currents under compression-shear mode has been experimentally studied. The results show that the amplitude of the applied current had little effect on the rising time of transient torque, while the rising time was significantly affected by the rotational speed, the compressive speed and the compressive strain position. The falling time of transient torque was independent of the amplitude of the applied current, the compressive speed and the compressive strain position, and it was affected by the rotational speed. The falling time of the transient torque was much shorter than the rising time by a step current. The transient process of MR brake applied as a step current was different from a stable process pre-applied at constant current in different particle chain structure forming processes. In addition, the compressive processes applied in one step current and randomly on/off current were compared and experimentally verified: the particle chains in two processes both experienced the same evolutionary of transient torque. The results achieved in this study should be properly considered in the design and control of magnetorheological brake under compression-shear mode.
- Open Access
- 26 April 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-10
Compressions of magnetorheological fluids under instantaneous magnetic field and constant area
Compressions of magnetorheological (MR) fluids have been carried out under instantaneous magnetic fields. The yield strength of the MR fluid in compressive mode has been derived by assuming that it was a transformed shear flow in Bi-visous model. The compressive stresses have experimentally studied under different magnetic fields, different initial gap distances and different compressive velocities. The nominal yield shear stresses of the compressed MR fluid under different influential factors have been calculated. The compressive stress increased in a power law as the applied magnetic field increased, while it decreased as the initial gap distance and the compressive velocity increased. With the increase of magnetic field, the difference between the nominal yield shear stress curves increased, and the exponents of the power law increased with the increase of the magnetic field strengths. A larger initial gap distance and a lower compressive velocity resulted in a higher nominal yield shear stress under the same instantaneous magnetic field. The achieved results of the nominal yield shear stress with magnetic field seemed to deviate from the prediction of dipole model, and the chain structure aggregation effect, the sealing effect and the friction effect by compression should be considered.
- 26 April 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-10
Open AccessCompressions of magnetorheological fluids under instantaneous magnetic field and constant area
Compressions of magnetorheological (MR) fluids have been carried out under instantaneous magnetic fields. The yield strength of the MR fluid in compressive mode has been derived by assuming that it was a transformed shear flow in Bi-visous model. The compressive stresses have experimentally studied under different magnetic fields, different initial gap distances and different compressive velocities. The nominal yield shear stresses of the compressed MR fluid under different influential factors have been calculated. The compressive stress increased in a power law as the applied magnetic field increased, while it decreased as the initial gap distance and the compressive velocity increased. With the increase of magnetic field, the difference between the nominal yield shear stress curves increased, and the exponents of the power law increased with the increase of the magnetic field strengths. A larger initial gap distance and a lower compressive velocity resulted in a higher nominal yield shear stress under the same instantaneous magnetic field. The achieved results of the nominal yield shear stress with magnetic field seemed to deviate from the prediction of dipole model, and the chain structure aggregation effect, the sealing effect and the friction effect by compression should be considered.