Oktay Elkoca
Research Subjects
Oktay Elkoca has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
A. Binnaz Hazar Yoruç
Yildiz Technical University
3 shared publicationsAysu Karakas
Yildiz Technical University
3 shared publications- Bülent Ekmekci
Mechanical Engineering Department, Zonguldak Bulent Ecevit University, Zonguldak, Turkey
3 shared publications - Nuri Şen
Düzce University
3 shared publications Abdulkadir Erden
Manufacturing Engineering Department , Atilim University , Turkey
2 shared publicationsAhmet Koyun
2 shared publications
Latest Publications
- Open Access
- 25 June 2025
- Published by Polish Academy of Sciences Chancellery in Archives of Metallurgy and Materials
- p. 651-661
Investigation of the Flow Behaviour of Martensitic Steel at Elevated Temperatures Via Uniaxial Tensile Tests
In recent years, advanced high strength steels have been the main choice of automobile manufacturers due to their excellent strengths and decent formability. In this study, the forming behaviour of a martensitic steel (MART 1200) at elevated temperatures, where higher formability and an acceptable strength can be achieved, has been investigated. For this purpose, tensile test experiments have been conducted at room temperature, 175°C, 275°C, 375°C and 475°C in two different strain rates (0.005 s–1, 0.05 s–1). The flow behaviour, elongation capacity, strain rate sensitivity, strain hardening and strain hardening rate of MART1200 have been investigated and fracture surfaces and microstructures have been examined by scanning electron microscope. It has been shown that the strain rate sensitivity of MART1200 increases significantly after 275°C and, for the higher strain rate, a significant improvement up to 80% in the elongation capacity has been achieved in return for a 19% strength reduction at 375°C.
- 25 June 2025
- Published by Polish Academy of Sciences Chancellery in Archives of Metallurgy and Materials
- p. 651-661
Open AccessInvestigation of the Flow Behaviour of Martensitic Steel at Elevated Temperatures Via Uniaxial Tensile Tests
In recent years, advanced high strength steels have been the main choice of automobile manufacturers due to their excellent strengths and decent formability. In this study, the forming behaviour of a martensitic steel (MART 1200) at elevated temperatures, where higher formability and an acceptable strength can be achieved, has been investigated. For this purpose, tensile test experiments have been conducted at room temperature, 175°C, 275°C, 375°C and 475°C in two different strain rates (0.005 s–1, 0.05 s–1). The flow behaviour, elongation capacity, strain rate sensitivity, strain hardening and strain hardening rate of MART1200 have been investigated and fracture surfaces and microstructures have been examined by scanning electron microscope. It has been shown that the strain rate sensitivity of MART1200 increases significantly after 275°C and, for the higher strain rate, a significant improvement up to 80% in the elongation capacity has been achieved in return for a 19% strength reduction at 375°C.
- Open Access
- 29 December 2023
- Published by Duzce Universitesi Bilim ve Teknoloji Dergisi in Düzce Üniversitesi Bilim ve Teknoloji Dergisi
- Vol. 11 (5) , 2309-2320
Determination of Modified Mohr-Coulomb Damage Model Parameters for DH780 Steel in Finite Element Analysis
In sheet metal forming processes, tearing problems might be occasionally encountered due to many reasons such as incorrect forming parameters. The trial and error methods that are used to solve such problems, on many occasions, are time-consuming and inefficient in terms of finding the correct forming parameters or die design for the forming process. The finite element analysis method, on the other hand, can be used as a tool that is both time and cost-saving. However, in order to effectively exploit the use of finite element analysis in sheet metal forming operations, the material that is used to be formed needs to be well characterized in terms of its hardening behaviour and failure criteria. In this study, a TRIP-aided DP steel (DH780) has been tensile tested in three different deformation conditions (uniaxial, plane stress and shear) and the parameters of its hardening model (Hollomon) and failure criteria (Modified Mohr-Coulomb) have been determined. According to the simulation results, obtained hardening parameters are able to describe the flow behaviour of the steel and the used failure criterion is able to predict the experimental failure correctly in each deformation condition.
- 29 December 2023
- Published by Duzce Universitesi Bilim ve Teknoloji Dergisi in Düzce Üniversitesi Bilim ve Teknoloji Dergisi
- Vol. 11 (5) , 2309-2320
Open AccessDetermination of Modified Mohr-Coulomb Damage Model Parameters for DH780 Steel in Finite Element Analysis
In sheet metal forming processes, tearing problems might be occasionally encountered due to many reasons such as incorrect forming parameters. The trial and error methods that are used to solve such problems, on many occasions, are time-consuming and inefficient in terms of finding the correct forming parameters or die design for the forming process. The finite element analysis method, on the other hand, can be used as a tool that is both time and cost-saving. However, in order to effectively exploit the use of finite element analysis in sheet metal forming operations, the material that is used to be formed needs to be well characterized in terms of its hardening behaviour and failure criteria. In this study, a TRIP-aided DP steel (DH780) has been tensile tested in three different deformation conditions (uniaxial, plane stress and shear) and the parameters of its hardening model (Hollomon) and failure criteria (Modified Mohr-Coulomb) have been determined. According to the simulation results, obtained hardening parameters are able to describe the flow behaviour of the steel and the used failure criterion is able to predict the experimental failure correctly in each deformation condition.
- 6 September 2021
- Published by Polish Academy of Sciences Chancellery in Archives of Metallurgy and Materials
- Vol. 66 (3) , 847-851
A study on the Surface Roughness of Galvannealed Low Carbon Al-Killed and Ti-Nb Stabilized Interstitial Free Steels
In this study, the surface roughness of galvannealed low carbon Al-killed and Ti-Nb stabilized interstitial free steels was investigated using the industrial galvannealing process parameters. The iron content of the coatings was also analysed to establish a relationship with the surface roughness and coating composition. The surface roughness displayed an exponential behaviour with increasing of annealing time at each annealing temperature in both steel coatings, which was in an increasing order in the galvannealed low carbon Al-killed steel coating, whereas it was a reverse order in the galvannealed Ti-Nb stabilized interstitial free steel coating. The craters were observed on the galvannealed coatings resulting in high surface roughness. Increasing the iron content of the coatings leads to a reduction in the surface roughness with δ1k phase.
- 6 September 2021
- Published by Polish Academy of Sciences Chancellery in Archives of Metallurgy and Materials
- Vol. 66 (3) , 847-851
A study on the Surface Roughness of Galvannealed Low Carbon Al-Killed and Ti-Nb Stabilized Interstitial Free Steels
In this study, the surface roughness of galvannealed low carbon Al-killed and Ti-Nb stabilized interstitial free steels was investigated using the industrial galvannealing process parameters. The iron content of the coatings was also analysed to establish a relationship with the surface roughness and coating composition. The surface roughness displayed an exponential behaviour with increasing of annealing time at each annealing temperature in both steel coatings, which was in an increasing order in the galvannealed low carbon Al-killed steel coating, whereas it was a reverse order in the galvannealed Ti-Nb stabilized interstitial free steel coating. The craters were observed on the galvannealed coatings resulting in high surface roughness. Increasing the iron content of the coatings leads to a reduction in the surface roughness with δ1k phase.
- 3 November 2019
- Published by SAGE Publications in Ironmaking & Steelmaking: Processes, Products and Applications
- Vol. 46 (10) , 944-952
Mechanical properties of ultra-high-strength steels at elevated temperatures
This paper presents an experimental study on the mechanical properties of ultra-high-strength steels at elevated temperatures. Tensile tests were carried out at 300–600°C on Docol 1200M and Docol 1400M steel samples. The results indicate that as the temperature increases Young’s Modulus, yield strength (YS) and ultimate tensile strength (UTS) display a decrease. YS/UTS ratios at 300°C are lower than those at room temperature, they make peaks at 400 and 500°C for Docol 1400M and Docol 1200M, respectively, and then decrease again beyond those temperatures. While total elongation continuously increases, uniform elongation slightly decreases with increasing temperature. Present carbides in tempered matrix continue to grow and new carbides are observed at the grain boundaries. Considering all roll forming parameters, 300°C seems the most convenient temperature for warm forming. In this sense, the warm roll forming has a potential for forming complex-shaped parts by reconciling strength with formability.
- 3 November 2019
- Published by SAGE Publications in Ironmaking & Steelmaking: Processes, Products and Applications
- Vol. 46 (10) , 944-952
Mechanical properties of ultra-high-strength steels at elevated temperatures
This paper presents an experimental study on the mechanical properties of ultra-high-strength steels at elevated temperatures. Tensile tests were carried out at 300–600°C on Docol 1200M and Docol 1400M steel samples. The results indicate that as the temperature increases Young’s Modulus, yield strength (YS) and ultimate tensile strength (UTS) display a decrease. YS/UTS ratios at 300°C are lower than those at room temperature, they make peaks at 400 and 500°C for Docol 1400M and Docol 1200M, respectively, and then decrease again beyond those temperatures. While total elongation continuously increases, uniform elongation slightly decreases with increasing temperature. Present carbides in tempered matrix continue to grow and new carbides are observed at the grain boundaries. Considering all roll forming parameters, 300°C seems the most convenient temperature for warm forming. In this sense, the warm roll forming has a potential for forming complex-shaped parts by reconciling strength with formability.
- 4 February 2014
- Published by Emerald Publishing in Industrial Lubrication and Tribology
- Vol. 66 (1) , 106-110
Wear behaviour of Ti6Al4V alloy blasted with zirconia/hydroxyapatite powders
Purpose: – The purpose of this paper is to investigate the effect of blasting treatment with zirconia/hydroxyapatite powders on the surface roughness, in vitro bioactivity and wear behavior of Ti6Al4V alloy (Grade V). Design/methodology/approach: – Ti6Al4V specimens were sandblasted with ZrO2 and HA [Ca10(PO4)6(OH)2] powders in a commercial blasting cabinet. Surface analysis was performed evaluating eroded surfaces by scanning electron microscopy. Roughness surface analysis of the samples was performed with a surface roughness tester and in vitro bioactivity of titanium surfaces was examined in the simulated body fluid (SBF) solution before and after blasting. Wear resistance is evaluated by the weight loss during the test. Findings: – The highest value of surface roughness is obtained with a mixture of 25 percent ZrO2+75 percent HA (Z25). Z25 exhibited also lower weight loss than Ti6Al4V and other treated samples. These results indicate that surface treatment with 25 percent ZrO2+75 percent HA provides the highest amount of HA adhesion on the surface of Ti6Al4V implant. Finally, the sample surfaces were contacted with SBF solutions for seven days, and Ca/P accumulation was identified on the blasted surfaces. ZrO2/HA blasting method can be used to improve the wear characteristics and the biocompatibility of the implant materials. Originality/value: – The paper provides information about the effect of ZrO2/HA blasting treatment on the surface properties, in vitro bioactivity and wear behavior of Ti6Al4V implant materials.
- 4 February 2014
- Published by Emerald Publishing in Industrial Lubrication and Tribology
- Vol. 66 (1) , 106-110
Wear behaviour of Ti6Al4V alloy blasted with zirconia/hydroxyapatite powders
Purpose: – The purpose of this paper is to investigate the effect of blasting treatment with zirconia/hydroxyapatite powders on the surface roughness, in vitro bioactivity and wear behavior of Ti6Al4V alloy (Grade V). Design/methodology/approach: – Ti6Al4V specimens were sandblasted with ZrO2 and HA [Ca10(PO4)6(OH)2] powders in a commercial blasting cabinet. Surface analysis was performed evaluating eroded surfaces by scanning electron microscopy. Roughness surface analysis of the samples was performed with a surface roughness tester and in vitro bioactivity of titanium surfaces was examined in the simulated body fluid (SBF) solution before and after blasting. Wear resistance is evaluated by the weight loss during the test. Findings: – The highest value of surface roughness is obtained with a mixture of 25 percent ZrO2+75 percent HA (Z25). Z25 exhibited also lower weight loss than Ti6Al4V and other treated samples. These results indicate that surface treatment with 25 percent ZrO2+75 percent HA provides the highest amount of HA adhesion on the surface of Ti6Al4V implant. Finally, the sample surfaces were contacted with SBF solutions for seven days, and Ca/P accumulation was identified on the blasted surfaces. ZrO2/HA blasting method can be used to improve the wear characteristics and the biocompatibility of the implant materials. Originality/value: – The paper provides information about the effect of ZrO2/HA blasting treatment on the surface properties, in vitro bioactivity and wear behavior of Ti6Al4V implant materials.
- 24 January 2012
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 445, 691-696
Yttria-Doped Zirconia-Hydroxyapatite Composite Coating on Cp-Ti Implants by Biomimetic Method
Titanium (Ti) and Ti-alloys are often used in dental and orthopedic applications because of their good mechanical properties and biocompatibility. The advantages of Ti and Ti-alloys are its superior corrosion resistance, high fatigue strength and low elastic modulus which reduce stress shielding. Morover biocompatibility of them can be improved coating with bioceramics such as hydroxyapatite (HA) or other ceramic composites. The hydroxyapatite [Ca10(PO4)6(OH)2, H is frequently used as a coating material on the surfaces of Ti-based medical implants to improve the bone fixation and thus the lifetime of the implant is increased. However, the main weakness of HA lies on its poor mechanical strength that makes it unsuitable for load-bearing applications. An attractive way to produce the tougher HA is to use composite powders such as Yttria-Doped Zirconia-Hydroxyapatite (YSZ-HA) consisting of 8 mol% yttria-stabilized tetragonal zirconia (YSZ) so that the apatite phase increases the biocompatibility and zirconia (ZrO2) phase improves the strength. Y2O3 addition into zirconia can stabilize the tetragonal phase at room temperature (YSZ) and the tetragonal phase plays a major role to increase the fracture toughness. In the present study yttria-dopped zirconia powders by using ZrO(NO3)2.xH2O and Y(NO3)3.6H2O were produced to synthesize HA-YSZ composites. In accordance with this purpose, at the first step, Ca (NO3)2.4H2O, (NH4)2HPO4 and YSZ powders were dissolved in simulated body fluids (SBF) to obtain sol. The gelatin solutions with different concentration were added into sol to provide the gelation. Then the surfaces of Ti implants were soaked in this solution. The coating rate of Ti samples was arranged as 14 cm/s and coated implants were sintered at 900°C. Structural analysis of coated powders was obtained by using XRD. Morphological examinations and coating thickness were investigated by SEM. After the sol-gel solution was dried at 80°C, dried-powder was sintered at 900°C. Sintered powders were analyzed by FT-IR to determine any gelatin residue.
- 24 January 2012
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 445, 691-696
Yttria-Doped Zirconia-Hydroxyapatite Composite Coating on Cp-Ti Implants by Biomimetic Method
Titanium (Ti) and Ti-alloys are often used in dental and orthopedic applications because of their good mechanical properties and biocompatibility. The advantages of Ti and Ti-alloys are its superior corrosion resistance, high fatigue strength and low elastic modulus which reduce stress shielding. Morover biocompatibility of them can be improved coating with bioceramics such as hydroxyapatite (HA) or other ceramic composites. The hydroxyapatite [Ca10(PO4)6(OH)2, H is frequently used as a coating material on the surfaces of Ti-based medical implants to improve the bone fixation and thus the lifetime of the implant is increased. However, the main weakness of HA lies on its poor mechanical strength that makes it unsuitable for load-bearing applications. An attractive way to produce the tougher HA is to use composite powders such as Yttria-Doped Zirconia-Hydroxyapatite (YSZ-HA) consisting of 8 mol% yttria-stabilized tetragonal zirconia (YSZ) so that the apatite phase increases the biocompatibility and zirconia (ZrO2) phase improves the strength. Y2O3 addition into zirconia can stabilize the tetragonal phase at room temperature (YSZ) and the tetragonal phase plays a major role to increase the fracture toughness. In the present study yttria-dopped zirconia powders by using ZrO(NO3)2.xH2O and Y(NO3)3.6H2O were produced to synthesize HA-YSZ composites. In accordance with this purpose, at the first step, Ca (NO3)2.4H2O, (NH4)2HPO4 and YSZ powders were dissolved in simulated body fluids (SBF) to obtain sol. The gelatin solutions with different concentration were added into sol to provide the gelation. Then the surfaces of Ti implants were soaked in this solution. The coating rate of Ti samples was arranged as 14 cm/s and coated implants were sintered at 900°C. Structural analysis of coated powders was obtained by using XRD. Morphological examinations and coating thickness were investigated by SEM. After the sol-gel solution was dried at 80°C, dried-powder was sintered at 900°C. Sintered powders were analyzed by FT-IR to determine any gelatin residue.
- 24 January 2012
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 445, 685-690
Zirconia-Hydroxyapatite Composite Coating on Cp-Ti Implants by Biomimetic Method
Hydroxyapatite (HA) is the major component of the natural hard tissues such as teeth and bone. It has been studied extensively as a candidate biomaterial for its use in prosthetic applications. However, the main weakness of this material lies in its poor mechanical strength which makes it unsuitable for load-bearing applications. On the other hand zirconia (ZrO2) powder has been widely studied because of its high strength and fracture toughness and good biocompatibility. Therefore, the addition of zirconia phase into HA will improve the mechanical properties and biocompatibility of HA ceramics. The present study focused on coating of HA-ZrO2 on commercially pure titanium (cp-Ti) using novel biomimetic sol-gel method. The HA-ZrO2 coatings produced with BSG method were exhibited highly crystalline and pure structure. The coating thickness of the samples was not significantly influenced by the change in gelatin concentration and volume. It was concluded that the suggested coating method is a useful method to produce a biomimetic coating layer on the cp-Ti sample surfaces.
- 24 January 2012
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 445, 685-690
Zirconia-Hydroxyapatite Composite Coating on Cp-Ti Implants by Biomimetic Method
Hydroxyapatite (HA) is the major component of the natural hard tissues such as teeth and bone. It has been studied extensively as a candidate biomaterial for its use in prosthetic applications. However, the main weakness of this material lies in its poor mechanical strength which makes it unsuitable for load-bearing applications. On the other hand zirconia (ZrO2) powder has been widely studied because of its high strength and fracture toughness and good biocompatibility. Therefore, the addition of zirconia phase into HA will improve the mechanical properties and biocompatibility of HA ceramics. The present study focused on coating of HA-ZrO2 on commercially pure titanium (cp-Ti) using novel biomimetic sol-gel method. The HA-ZrO2 coatings produced with BSG method were exhibited highly crystalline and pure structure. The coating thickness of the samples was not significantly influenced by the change in gelatin concentration and volume. It was concluded that the suggested coating method is a useful method to produce a biomimetic coating layer on the cp-Ti sample surfaces.
- 24 January 2012
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 445, 679-684
Hydroxyapatite Coating on Cp-Ti Implants by Biomimetic Method
Hydroxyapatite (HA) is the main inorganic component in the human hard tissues, such as bones and teeth. The use of HA in load-bearing orthopedic applications has been extensively studied to achieve a biocompatible coating layer on implant metals. Commercial pure titanium (cp-Ti) is the most commonly used metallic material in the manufacture of orthopedic implants. Uncoated metal surfaces generally show numerous toxic effects to the surrounding tissues. However, coating of the metallic surfaces before implantation may prevent the interference of implant surfaces in biological media and also could accelerate the new bone formation. The present study focused on the coating of HA on cp-Ti implants, using novel biomimetic sol-gel method. The surfaces of cp-titanium substrates were coated with novel biomimetic sol gel (BSG) method under biological conditions (37°C and pH= 7.4). A bone-like apatite with a nanosized and pure HA structure was formed on the substrates under atmospheric pressure. The pre-coating results indicate that the novel biomimetic sol gel method is definitely a promising coating route in case that optimum coating parameters are established in detail.
- 24 January 2012
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 445, 679-684
Hydroxyapatite Coating on Cp-Ti Implants by Biomimetic Method
Hydroxyapatite (HA) is the main inorganic component in the human hard tissues, such as bones and teeth. The use of HA in load-bearing orthopedic applications has been extensively studied to achieve a biocompatible coating layer on implant metals. Commercial pure titanium (cp-Ti) is the most commonly used metallic material in the manufacture of orthopedic implants. Uncoated metal surfaces generally show numerous toxic effects to the surrounding tissues. However, coating of the metallic surfaces before implantation may prevent the interference of implant surfaces in biological media and also could accelerate the new bone formation. The present study focused on the coating of HA on cp-Ti implants, using novel biomimetic sol-gel method. The surfaces of cp-titanium substrates were coated with novel biomimetic sol gel (BSG) method under biological conditions (37°C and pH= 7.4). A bone-like apatite with a nanosized and pure HA structure was formed on the substrates under atmospheric pressure. The pre-coating results indicate that the novel biomimetic sol gel method is definitely a promising coating route in case that optimum coating parameters are established in detail.
- 30 June 2008
- Published by Elsevier in Engineering Failure Analysis
- Vol. 15 (4) , 295-301
Cracking during cold forming process of rear brake component
- 30 June 2008
- Published by Elsevier in Engineering Failure Analysis
- Vol. 15 (4) , 295-301
Cracking during cold forming process of rear brake component
- 1 March 2008
- Published by Elsevier in Surface and Coatings Technology
- Vol. 202 (12) , 2765-2774
A study on the characteristics of electrical discharge textured skin pass mill work roll
- 1 March 2008
- Published by Elsevier in Surface and Coatings Technology
- Vol. 202 (12) , 2765-2774
A study on the characteristics of electrical discharge textured skin pass mill work roll