RGRuochen Guo

Ruochen Guo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ruochen Guo has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Electrical Architecture of 90-Seater Electric Aircraft: A Cable Perspective

    by Ruochen Guo, Jianning Dong, Rob E. Wolleswinkel, Reynard de Vries, Mohamad Ghaffarian Niasar

    Optimized power system architectures and lighter weight are enabling considerations for the successful development of all-electric aircraft (AEA). In this article, a cross-redundant connection architecture and weight reduction solutions are investigated for a 90-seater full battery-electric aircraft from the perspective of high-power aviation cable. Design criteria of the power system architecture are introduced. Material selection, sizing, and weight estimation methods of cable for AEA are discussed by combining ground cable standards with aviation requirements. The influence of the conductor materials, voltage level, current, battery pack quantity, and operating temperature on cable evaluation is thoroughly discussed and analyzed. Weight comparison under two controversial voltage level options (800V and 3kV) is conducted. Comparison results show that the utilization of an aluminum conductor, PTFE insulator, and a voltage level of 3kV proves to be a preferable selection for current AEA medium and high voltage cables. Increasing the rating operation temperature to 120°C is a conservative and secure option. The layout of battery packs consistent with the quantity of distributed electric motors is preferable to achieve the lightest cabling system. This study provides a guideline for the cable sizing methods of high-power aviation cables and an optimized design solution for the power system architecture of AEA from the perspective of cable layout and weight assessment.


  • A Novel Composite Sensor for UHF Partial Discharge and Gas State Measurement in GIS

    by Huan Chen, Haotian Wang, Zhaoyu Zhang, Ruochen Guo, Xutao Han, Xuanrui Zhang, Junhao Li

    The gas state of the insulating gas significantly impacts the development and extent of the partial discharge (PD) in gas insulated switchgear (GIS). Correlating these two factors allows for a more comprehensive diagnosis of insulation defects. At present, the ultra-high frequency (UHF) method has been widely used for PD detection in GIS. However, measurements of the insulating gas’s state in the field are primarily conducted offline or at gas valves, providing ineffective data for reference. To address this challenge, this paper introduces a novel composite sensor capable of simultaneous UHF and gas state measurements. Building upon the disc-type UHF sensor structure, the composite sensor integrates a gas state sensing unit with the microelectromechanical systems (MEMS) sensor as the core. A robust shielding shell is designed through finite element simulation to ensure the safety of the sensor, with the maximum induced voltage and electric field strength on the sensing unit measuring 0.28V and 414V/m, respectively. The average UHF measurement sensitivity of the composite sensor reaches 13.3mm. In addition, the composite sensor exhibits low errors (±0.2°C, ±3kPa and ±10μL/L), high consistency and repeatability in temperature, pressure and moisture measurement. Finally, the composite sensor has demonstrated its capability to simultaneously and safely detect PD signals and the gas state within GIS.


  • Behavior Characteristics of Cellulose Particles in Insulating Oil Gaps Under a DC Electric Filed

    by Xuan Meng, Ruochen Guo, Haotian Wang, Xutao Han, Xuanrui Zhang, Junhao Li

    During the long-term operation of converter transformers, the aging and decomposition of oil-paper insulation lead to the presence of cellulose particles in transformer oil, which affects the safe operation of the equipment. The motion characteristics of cellulose particles in short oil gaps and long oil gaps under a DC electric field are studied. The forces acting on a single particle, the aggregation characteristics of multiple particles, and the conditions for particle chain breakage are calculated and analyzed. An experimental platform is constructed to validate the conclusions. The results show that cellulose particles in transformer oil are subjected to the combined action of various forces under a DC electric field. Under the influence of the dipole force, multiple cellulose particles attract each other and form particle chains along the direction of the electric field. Changes in internal forces within the particle chain can cause the chain to break. The movement of particles in oil is closely related to the adsorption time of particle chains on the electrode surface and their movement time within the oil gap, which is affected by the resistivity, particle size, charge quantity, and external electric field intensity of the particles. In the experiments, particles form cellulose bridges in short oil gaps, while in long oil gaps, they move freely in transformer oil in the form of particle chains.


  • Partial Discharge Measurement and Analysis of Transformer Under Oscillating Lightning Impulse Voltage

    by Xuanrui Zhang, Ruochen Guo, Yun Yang, Yidan Hu, Zhaoyu Zhang, Junhao Li, Xutao Han

    Oscillating lightning impulse (OLI) voltage is recommended for on-site testing due to its high generation efficiency. In this paper, partial discharge (PD) characteristics under field impulse voltage waveforms are investigated. The experiment is carried out on a scaled transformer model with a protrusion defect inside as the PD source. Both oscillating and standard lightning impulse (SLI) voltages are acquired as test waveforms. Main discharges and reverse discharges are detected simultaneously under both OLI and SLI voltage. The increasing applied voltage amplitude advances the main discharge and enlarges its amplitude, and it also prolongs the duration of the reverse discharge and increases the number. The amplitude of main discharge is related to the PD voltage, while that of reverse discharge depends on the dynamic variation of the impulse voltage. Since OLI voltage contains multiple rising edges during the oscillation period, more PDs are excited. Disruptive effect (DE) model is extended for PD analysis to show the oscillation effect on PD distribution. The OLI test with PD measurement performed on a 220 kV transformer proves that PD detection during impulse voltage withstand test reflects more detailed information that can be used for early diagnosis of power transformers.


  • A Novel Ultrasound-Vibration Composite Sensor for Defects Detection of Electrical Equipment

    by Zhaoyu Zhang, Junhao Li, Yanfeng Song, Yuan Sun, Xuanrui Zhang, Yidan Hu, Ruochen Guo, Xu Tao Han

    The faults of electrical equipment are mainly generated by electrical and mechanical defects, which are usually detected by external ultrasonic and vibration sensors respectively. To improve the accuracy and efficiency of the diagnosis, a novel ultrasound-vibration composite sensor(UVCS) which can detect ultrasound and vibration acceleration signals synchronously at the same place, is proposed and developed scientifically in this paper. The working principle of UVCS is based on the combination of the mass and the backing as well as the steel base and matching layer, and the structure is improved reasonably. Furthermore, the ultrasound and vibration signals can be separated by filtering. In addition, the test results on a 110kV GIS show the high precision and reliability of UVCS and illustrate the superiority in practical application.


  • Open Access

    Partial discharge measurement and analysis under lightning impulse superimposed DC voltage in SF6 gas

    by Haotian Wang, Cong He, Ruochen Guo, Xuan Meng, Wenze Yuan, Junhao Li

    The presence of lightning impulses (LIs) on the DC waveform can seriously influence the insulation performance of a GIL system. The waveshape can be a superposition of the DC and impulse waveform. In this study, the behaviour of partial discharge (PD) on an epoxy surface is investigated under DC and LI superimposed voltage in SF 6 . The lightning impulses with different polarities are superimposed on the epoxy surface under both positive and negative DC voltages, respectively. Positive lightning impulses are superimposed on a negative DC voltage with a 90% of the partial discharge inception voltage (PDIV) magnitude. The number and amplitude of the PDs are used to evaluate the insulation performance. The experimental results show that the LI with a different polarity applied to DC can excite the PDs on the epoxy surface. The excitation effect of positive LI superimposed on negative DC is more significant. According to the impulse amplitude and PD characteristics, the influence of superimposed LI on PD excitation can be divided into three stages. As the superimposed LI increases, the amplitude of the excited PD increases gradually, while the PD number first increases and then decreases. This study is expected to provide reference for manufacture and protection of power equipment.


  • Research on effectiveness of lightning impulses with different parameters for detecting protrusion defects in GIS

    by Liang Zhang, Cong He, Ruochen Guo, Wenze Yuan, Junhao Li

    The focus of this paper is on the effectiveness of lightning impulse (LI) with different parameters for detecting protrusion defects in gas insulated switchgear (GIS). The study examines the 50% (U 50 ) breakdown probability for typical protrusion defects on the conductor of a 363 kV class GIS. A quantitative method is developed to predict breakdown voltage, calculate minimum detectable length of defect, and express the effectiveness of the LI test. The results show that there is little difference of U 50 between aperiodic and oscillating LI. Corresponding detecting effectiveness decreases for LI with long wavefront, which is expressed quantitatively by detectable area. The critical defect length detected increases with increased wavefront. This study provides a general method to express the effectiveness of LI with different parameters for detecting protrusion defects and it support the LI test for on-site testing of GIS.


  • Characteristics of AC PDs on epoxy insulation surface excited by different impulse voltages in SF6 gas

    by Cong He, Minxia Shi, Ruochen Guo, Xuanrui Zhang, Junhao Li

    In this paper the behavior of partial discharges (PDs) on epoxy insulation under AC and impulse superimposed voltages are experimentally investigated in SF 6 gas. The lightning impulse (LI) and the switching impulse (SI) voltages with different polarity are superimposed on different phases of the AC voltage. PDs are measured by three sensors, a 50 Ω measurement impedance, an ultra-high frequency sensor and a photomultiplier tube. The max PD amplitude, PD pulse number and PD duration under AC voltage after an impulse voltage are summarized and analyzed. The effect of the impulse superposition phase, the impulse type and the impulse polarity on the characteristics of AC PDs are discussed. Results show that after a positive impulse voltage was applied on the positive semi-wave of AC voltage (0 to 180°), PDs in the negative half cycle of the AC voltage can be remarkably excited. A negative impulse voltage was applied on the negative semi-wave (180 to 360°), AC PDs can be initiated in the positive half cycle of AC voltage. PDs excited by a LI voltage is severe than excited by a SI. PDs excited by a positive impulse is intense than excited by a negative impulse.


  • Open Access

    Study on the combined characteristics of UHF and optical signals induced by partial discharge at spacer surface in GIS

    by Xutao Han, Ruochen Guo, Shuhang Shen, Junhao Li, Wei Sun

    In this study, to improve the sensitivity and accuracy of the detection of surface partial discharge (PD) in gas insulation switchgears (GISs), a combination of ultra‐high frequency (UHF) and optical methods is proposed based on an integrated sensor. The PD triggered by a fixed metal needle defect attached to the spacer is detected from PD inception to flashover in a real GIS. The characteristics of UHF and optical signals under different applied voltages are compared and analysed in terms of PD waveform, Phase Resolved Partial Discharge (PRPD) pattern, PD count and amplitude. The results show that the surface discharge process can be precisely divided into three stages according to the combined characteristics of the UHF and optical signals. The comparison of the two detection methods shows that the optical method can detect the weak avalanche PD under low voltage while UHF cannot, so it can detect more PDs than UHF method in an AC cycle. In addition, with the deterioration of solid insulation material, the amplitude of the optical signal increases significantly while the amplitude of the UHF signal only increases slightly.


  • Investigation of the Synergistic Effect of CF3I/CF4 Gas Mixture

    by Su Zhao, Ruishuang Zhong, Dengming Xiao, Yunkun Deng, Ruochen Guo, Zhiqiang Hou, Zhen Wang, Cong He, Xuanrui Zhang, Junhao Li, et al.

    In this paper, the synergistic effect of CF3I/CF4 gas mixture is calculated and experimentally studied. The results show that the critical field strength of CF3I/CF4 mixed gas calculated by Boltzmann equation increases linearly with the content of CF3I. However, under the action of power frequency voltage and lightning impulse, the mixed gas of CF3I/CF4 actually shows significant negative synergistic effect when the gas pressure is 0.1 similar to 0.3 MPa. The synergistic effect coefficient value of CF3I mixture shows a decreasing trend with the increase of pressure, and when the negative synergistic effect is most significant, the corresponding CF3I content also shows a decreasing trend.