Jiahao Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jiahao Lin has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Mou-Fa Guo
Fuzhou University
6 shared publications - Qiteng Hong
University of Strathclyde
5 shared publications - Feng Zheng
College of Electrical Engineering and Automation, Fuzhou University, Fuzhou 350108, China
2 shared publications - Ze-Yin Zheng
College of Electrical Engineering and Automation, Fuzhou University, Fuzhou, China
2 shared publications - Bin-Long Zhang
Fuzhou University
1 shared publication Changhong Deng
School of Electrical and Automation, Wuhan University, Wuhan, China
1 shared publication
Latest Publications
- 20 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-16
Single-Ended Traveling Wave Location for Single-Phase Ground Faults in Distribution Networks Based on Hough Transform
Current single-ended fault location methods for single-phase grounding faults in distribution networks are facing challenges such as difficulty in identifying reflected wavefronts, inaccurate judgment of wavefront reflection positions, and limited noise immunity, which reduce their feasibility for engineering applications. This paper proposes an efficient single-ended traveling wave location scheme aimed at enhancing the accuracy and reliability of fault location. Firstly, the improved Pettitt test is employed to accurately determine the arrival time of the fault wavefront, which avoids errors in judgment of the fault occurrence moment. Subsequently, the Pearson correlation coefficient is utilized to identify the initial wavefront and the wavefronts reflected from the fault point, reducing interference caused by other reflected wavefronts. To accurately calibrate the wavefront arrival time, the Hough transform is introduced to determine the wavefront position. Additionally, the paper discusses optimizing the arrangement of traveling wave location devices in the distribution network to improve location accuracy and reduce costs. Compared to existing methods, the proposed scheme directly analyzes the original waveform, achieving more accurate wavefront identification and better noise immunity. The effectiveness of the method is validated through software simulations and physical experiments, demonstrating that the fault location error can be controlled within 5%, even under arc grounding faults or noise interference.
- 20 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-16
Single-Ended Traveling Wave Location for Single-Phase Ground Faults in Distribution Networks Based on Hough Transform
Current single-ended fault location methods for single-phase grounding faults in distribution networks are facing challenges such as difficulty in identifying reflected wavefronts, inaccurate judgment of wavefront reflection positions, and limited noise immunity, which reduce their feasibility for engineering applications. This paper proposes an efficient single-ended traveling wave location scheme aimed at enhancing the accuracy and reliability of fault location. Firstly, the improved Pettitt test is employed to accurately determine the arrival time of the fault wavefront, which avoids errors in judgment of the fault occurrence moment. Subsequently, the Pearson correlation coefficient is utilized to identify the initial wavefront and the wavefronts reflected from the fault point, reducing interference caused by other reflected wavefronts. To accurately calibrate the wavefront arrival time, the Hough transform is introduced to determine the wavefront position. Additionally, the paper discusses optimizing the arrangement of traveling wave location devices in the distribution network to improve location accuracy and reduce costs. Compared to existing methods, the proposed scheme directly analyzes the original waveform, achieving more accurate wavefront identification and better noise immunity. The effectiveness of the method is validated through software simulations and physical experiments, demonstrating that the fault location error can be controlled within 5%, even under arc grounding faults or noise interference.
- 6 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
Synthetic Zero-Sequence Signal-Based Intelligent Location Method for Single-Phase Ground Fault in Distribution Networks
Distribution system structures are intricate and variable, with single-phase ground (SPG) fault occurring frequently. Existing section location methods for SPG faults are often influenced by manually set thresholds, resulting in low accuracy. This paper analyzes the relationship between the zero-sequence voltage and zero-sequence current synthesized from three-phase voltage and current under the condition of no zero-sequence transformer installed on the line, and proposes a SPG fault section threshold-free location method based on Swin-Transformer. Firstly, Fourier transform-based data processing methods correct phase errors caused by current transformers (CT) and eliminate the DC bias in synthesized zero-sequence currents. Secondly, the synthesized zero-sequence current waveform and the derivative of zero-sequence voltage waveform are overlaid on the same image, with the enclosed areas shaded to highlight the relationship between the two electrical quantities. Finally, the Transformer model is used to classify the differentiated images between the SPG fault section and sound section to achieve threshold-free fault location. The proposed method has been tested and validated on an industrial prototype in a 10 kV full-scale test system and deployed in actual distribution network. Experimental results demonstrate the method can accurately locate fault sections even under conditions of noise interference and inaccurate trigger timing.
- 6 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
Synthetic Zero-Sequence Signal-Based Intelligent Location Method for Single-Phase Ground Fault in Distribution Networks
Distribution system structures are intricate and variable, with single-phase ground (SPG) fault occurring frequently. Existing section location methods for SPG faults are often influenced by manually set thresholds, resulting in low accuracy. This paper analyzes the relationship between the zero-sequence voltage and zero-sequence current synthesized from three-phase voltage and current under the condition of no zero-sequence transformer installed on the line, and proposes a SPG fault section threshold-free location method based on Swin-Transformer. Firstly, Fourier transform-based data processing methods correct phase errors caused by current transformers (CT) and eliminate the DC bias in synthesized zero-sequence currents. Secondly, the synthesized zero-sequence current waveform and the derivative of zero-sequence voltage waveform are overlaid on the same image, with the enclosed areas shaded to highlight the relationship between the two electrical quantities. Finally, the Transformer model is used to classify the differentiated images between the SPG fault section and sound section to achieve threshold-free fault location. The proposed method has been tested and validated on an industrial prototype in a 10 kV full-scale test system and deployed in actual distribution network. Experimental results demonstrate the method can accurately locate fault sections even under conditions of noise interference and inaccurate trigger timing.
- 1 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
Amplitude-Phase-Characteristics-Based Fault Phase Detection Method for Grounding Fault in Distribution Network
The fault phase detection (FPD) of single-line-to-ground fault (SLGF) is important for active arc suppression device (AASD), but it is challenging when considering asymmetrical line parameters and different neutral grounding types. To improve the reliability of FPD, this paper proposes an FPD method based on the fusion of amplitude and phase angle characteristics. Firstly, when an SLGF occurs, the amplitude and phase angle characteristics of the three-phase source voltage are analyzed. Then, the phase angle of the fault phase source voltage is calculated based on the derived amplitude and phase angle characteristics, which is compared with the measured phase angle of three-phase source voltage respectively. According to the FPD criterion, the fault phase can be determined. In addition, a fault phase detection device (FPDD) featuring convenient installation has been designed. The FPD results are sent to AASD, if the fault phase voltage can be effectively suppressed, the FPD results are correct. The proposed method has been experimentally validated on 380V and 10kV experimental platforms.
- 1 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
Amplitude-Phase-Characteristics-Based Fault Phase Detection Method for Grounding Fault in Distribution Network
The fault phase detection (FPD) of single-line-to-ground fault (SLGF) is important for active arc suppression device (AASD), but it is challenging when considering asymmetrical line parameters and different neutral grounding types. To improve the reliability of FPD, this paper proposes an FPD method based on the fusion of amplitude and phase angle characteristics. Firstly, when an SLGF occurs, the amplitude and phase angle characteristics of the three-phase source voltage are analyzed. Then, the phase angle of the fault phase source voltage is calculated based on the derived amplitude and phase angle characteristics, which is compared with the measured phase angle of three-phase source voltage respectively. According to the FPD criterion, the fault phase can be determined. In addition, a fault phase detection device (FPDD) featuring convenient installation has been designed. The FPD results are sent to AASD, if the fault phase voltage can be effectively suppressed, the FPD results are correct. The proposed method has been experimentally validated on 380V and 10kV experimental platforms.
- 2 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (8) , 10067-10078
Online Split-Phase Identification of Asymmetric Parameters Between Distribution Lines and Ground for Unbalanced Voltage Compensation Based on Power Electronics
Most of the phase-to-ground parameters induced between distribution lines and ground are asymmetric, which can result in the generation of unbalanced voltage, shifting the neutral point voltage. For compensated distribution networks, the existence of an arc suppression coil can increase the influence of asymmetric parameters and exacerbate the deviation of neutral point voltage. Maintaining the balance of three-phase voltage is not only a prerequisite for the stable operation of the distribution networks, but also for improving the reliability of single-phase ground fault detection. This paper proposes a novel online split-phase identification of asymmetric parameters between distribution lines and ground for unbalanced voltage compensation based on power electronics. Firstly, an adaptive active current-type compensation method based on power electronics is proposed, it can adapt to compensate for threephase unbalanced voltage with different neutral point grounding styles. Secondly, particle swarm optimization is used to realize the online split-phase identification of the phase-to-ground parameters of the distribution power lines. The identified parameters are used to calculate the reference value of the compensation current and the asymmetry of each phase-toground parameter. Finally, the feasibility and effectiveness of the proposed method are verified by simulation and experiment.
- 2 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (8) , 10067-10078
Online Split-Phase Identification of Asymmetric Parameters Between Distribution Lines and Ground for Unbalanced Voltage Compensation Based on Power Electronics
Most of the phase-to-ground parameters induced between distribution lines and ground are asymmetric, which can result in the generation of unbalanced voltage, shifting the neutral point voltage. For compensated distribution networks, the existence of an arc suppression coil can increase the influence of asymmetric parameters and exacerbate the deviation of neutral point voltage. Maintaining the balance of three-phase voltage is not only a prerequisite for the stable operation of the distribution networks, but also for improving the reliability of single-phase ground fault detection. This paper proposes a novel online split-phase identification of asymmetric parameters between distribution lines and ground for unbalanced voltage compensation based on power electronics. Firstly, an adaptive active current-type compensation method based on power electronics is proposed, it can adapt to compensate for threephase unbalanced voltage with different neutral point grounding styles. Secondly, particle swarm optimization is used to realize the online split-phase identification of the phase-to-ground parameters of the distribution power lines. The identified parameters are used to calculate the reference value of the compensation current and the asymmetry of each phase-toground parameter. Finally, the feasibility and effectiveness of the proposed method are verified by simulation and experiment.
- Top Cited Papers
- 15 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 15 (4) , 3459-3473
An Earth Fault Diagnosis Method Based on Online Dynamically Calculated Thresholds for Resonant Ground Systems
The primary problem of distribution system protection is single-line-to-ground (SLG) fault, particularly in networks with distributed generators (DGs), where asymmetrical phase sequence components caused by SLG faults may lead to system instability. Currently, the location and suppression methods of SLG faults are based on reliable fault diagnosis. Therefore, considering the imbalance of line parameters, this paper analyzes the fault characteristics of zero-sequence voltage (ZSV), and proposes a threshold-online-calculating-based SLG fault diagnosis method, which includes fault detection, fault occurrence moment capture and fault nature estimation. Firstly, the ZSV is measured in real time by the designed feeder terminal unit (FTU), which is embedded with the proposed SLG fault diagnosis method. Secondly, the ZSV signal is decomposed by the Mallat algorithm, and the fault diagnosis thresholds are calculated through the maximum margin hyperplane, which is used for fault detection and fault nature estimation. Finally, the fault occurrence moment is captured by variational mode decomposition (VMD) and its Teager Energy Operator (TEO). The proposed SLG fault diagnosis method has been tested in simulation and physical experiments in a 10kV system, the effectiveness and feasibility have been validated.
- 15 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 15 (4) , 3459-3473
Top Cited PapersAn Earth Fault Diagnosis Method Based on Online Dynamically Calculated Thresholds for Resonant Ground Systems
The primary problem of distribution system protection is single-line-to-ground (SLG) fault, particularly in networks with distributed generators (DGs), where asymmetrical phase sequence components caused by SLG faults may lead to system instability. Currently, the location and suppression methods of SLG faults are based on reliable fault diagnosis. Therefore, considering the imbalance of line parameters, this paper analyzes the fault characteristics of zero-sequence voltage (ZSV), and proposes a threshold-online-calculating-based SLG fault diagnosis method, which includes fault detection, fault occurrence moment capture and fault nature estimation. Firstly, the ZSV is measured in real time by the designed feeder terminal unit (FTU), which is embedded with the proposed SLG fault diagnosis method. Secondly, the ZSV signal is decomposed by the Mallat algorithm, and the fault diagnosis thresholds are calculated through the maximum margin hyperplane, which is used for fault detection and fault nature estimation. Finally, the fault occurrence moment is captured by variational mode decomposition (VMD) and its Teager Energy Operator (TEO). The proposed SLG fault diagnosis method has been tested in simulation and physical experiments in a 10kV system, the effectiveness and feasibility have been validated.
- 24 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-12
Active Location Method for Single-Line-to-Ground Fault of Flexible Grounding Distribution Networks
The single-line-to-ground (SLG) fault is the most common fault in distribution networks. The output current of Cascaded H-bridges (CHB) can be controlled flexibly to suppress SLG fault current. Therefore, a CHB-based active location method is proposed in this paper, which integrates the functions of SLG fault arc suppression, fault section location, and fault nature judgment. When an SLG fault occurs, CHB devices quickly inject full compensated current into the system neutral to suppress the fault current. Then, CHB devices are regulated to reduce the injected current, the variations of zero-sequence voltage and zero-sequence current are actively constructed. The phase characteristics between zero-sequence voltage variation and zero-sequence current variation can be used as the criteria for fault section location and fault nature judgment. In addition, the measurement device, namely the retrofitted feeder terminal unit (FTU), contains signal acquisition module and signal calculation module is designed which can collect the zero-sequence signal and calculate the phase difference. Finally, the effectiveness of these three functions and the fault-location accuracy of the proposed method have been verified through the simulation and experimental cases.
- 24 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-12
Active Location Method for Single-Line-to-Ground Fault of Flexible Grounding Distribution Networks
The single-line-to-ground (SLG) fault is the most common fault in distribution networks. The output current of Cascaded H-bridges (CHB) can be controlled flexibly to suppress SLG fault current. Therefore, a CHB-based active location method is proposed in this paper, which integrates the functions of SLG fault arc suppression, fault section location, and fault nature judgment. When an SLG fault occurs, CHB devices quickly inject full compensated current into the system neutral to suppress the fault current. Then, CHB devices are regulated to reduce the injected current, the variations of zero-sequence voltage and zero-sequence current are actively constructed. The phase characteristics between zero-sequence voltage variation and zero-sequence current variation can be used as the criteria for fault section location and fault nature judgment. In addition, the measurement device, namely the retrofitted feeder terminal unit (FTU), contains signal acquisition module and signal calculation module is designed which can collect the zero-sequence signal and calculate the phase difference. Finally, the effectiveness of these three functions and the fault-location accuracy of the proposed method have been verified through the simulation and experimental cases.
- 4 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 13 (2) , 1049-1060
A Novel Flexible Fault Current Limiter for DC Distribution Applications
As an effective carrier of new energy collection, DC power grid has characteristics of low inertia and weak damping, which makes DC fault propagate extremely fast. However, the existing protection and DC circuit breaker (DCCB) technique still could not match its fault propagation speed. Therefore, to solve this problem, a novel of flexible fault current limiter (NFFCL) is presented in this paper. Under normal operation condition, NFFCL is connected to DC line in series without negative influence. When a fault occurs to DC line, NFFCL’s rectifier circuit, according to the protection criterion, provides cascade inductor, which is connected to DC line in series, with a set-slope linear current. In this case, the voltage drop between both ends of inductor can be clamped flexibly, which can even completely isolate the fault area. A controlled voltage source (CCVS) is applied to generate inverse flux to prevent the cascading inductor from magnetic saturation. When the fault disappears, the energy of current-limit inductor can be released and transferred to AC power grid through NFFCL’s converter. Finally, simulation cases are carried out to verify the working principles and practicability of proposed NFFCL.
- 4 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 13 (2) , 1049-1060
A Novel Flexible Fault Current Limiter for DC Distribution Applications
As an effective carrier of new energy collection, DC power grid has characteristics of low inertia and weak damping, which makes DC fault propagate extremely fast. However, the existing protection and DC circuit breaker (DCCB) technique still could not match its fault propagation speed. Therefore, to solve this problem, a novel of flexible fault current limiter (NFFCL) is presented in this paper. Under normal operation condition, NFFCL is connected to DC line in series without negative influence. When a fault occurs to DC line, NFFCL’s rectifier circuit, according to the protection criterion, provides cascade inductor, which is connected to DC line in series, with a set-slope linear current. In this case, the voltage drop between both ends of inductor can be clamped flexibly, which can even completely isolate the fault area. A controlled voltage source (CCVS) is applied to generate inverse flux to prevent the cascading inductor from magnetic saturation. When the fault disappears, the energy of current-limit inductor can be released and transferred to AC power grid through NFFCL’s converter. Finally, simulation cases are carried out to verify the working principles and practicability of proposed NFFCL.
- Open Access
Generalized Proportional Model of Relay Protection Based on Adaptive Homotopy Algorithm Transient Stability
Relay protection equipment is important to ensure the safe and stable operation of power systems. The risks should be evaluated, which are caused by the failure of relay protection. At present, the fault data and the fault status monitoring information are used to evaluate the failure risks of relay protection. However, there is a lack of attention to the information value of monitoring information in the normal operation condition. In order to comprehensively improve monitoring information accuracy and reduce, a generalized proportional hazard model (GPHM) is established to fully exploit the whole monitoring condition information during the whole operation process, not just the monitoring fault condition data, with the maximum likelihood estimation (MLE) used to estimate the parameters of the GPHM. For solving the nonlinear equation in the process of parameter estimations, the adaptive homotopy algorithm is adopted, which could ensure the reversibility of the Jacobi matrix. Three testing cases have been reviewed, to demonstrate that the adaptive homotopy algorithm is better than traditional algorithms, such as the Newton homotopy algorithm, regarding the calculation speed and convergence. Therefore, GPHM could not only reflect the real time state of the equipment, but also provide a sound theoretical basis for the selection of equipment maintenance types.
Open AccessGeneralized Proportional Model of Relay Protection Based on Adaptive Homotopy Algorithm Transient Stability
Relay protection equipment is important to ensure the safe and stable operation of power systems. The risks should be evaluated, which are caused by the failure of relay protection. At present, the fault data and the fault status monitoring information are used to evaluate the failure risks of relay protection. However, there is a lack of attention to the information value of monitoring information in the normal operation condition. In order to comprehensively improve monitoring information accuracy and reduce, a generalized proportional hazard model (GPHM) is established to fully exploit the whole monitoring condition information during the whole operation process, not just the monitoring fault condition data, with the maximum likelihood estimation (MLE) used to estimate the parameters of the GPHM. For solving the nonlinear equation in the process of parameter estimations, the adaptive homotopy algorithm is adopted, which could ensure the reversibility of the Jacobi matrix. Three testing cases have been reviewed, to demonstrate that the adaptive homotopy algorithm is better than traditional algorithms, such as the Newton homotopy algorithm, regarding the calculation speed and convergence. Therefore, GPHM could not only reflect the real time state of the equipment, but also provide a sound theoretical basis for the selection of equipment maintenance types.