LQLu Qu

Lu Qu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lu Qu has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Lightning Flashover Characteristic and Effective Protection Measures of 10 kV Distribution Line Network

    by Song Zhang, Xiaobin Xiao, Lei Jia, Huaifei Chen, Lu Qu, Chakhung Yeung, Yuxuan Ding, Yaping Du

    Among various failure causes, lightning overvoltage represents the most significant threat to overhead distribution lines, which serve as critical components in power systems. This study uses the hybrid partial element equivalent circuit (PEEC) multi-conductor transmission line (MTL) method to perform overvoltage simulations and investigate lightning risk distribution along distribution lines developed from a real 10 kV distribution networks in Guizhou, China. The results of the rocket-triggered lightning observation verify the accuracy of the hybrid method for direct lightning simulation. Combining the Monte Carlo method with the electro-geometric model (EGM), the impact of differential protection configurations on annual lightning flashover rates is analyzed. The results demonstrate that lightning strikes on phase wires generate high-magnitude overvoltages but with limited spatial influence, resulting in fewer pole flashovers. Conversely, strikes on poles produce lower overvoltage peaks but affect wider areas, leading to significantly more flashovers. Using annual flashover rates as the risk evaluation metric, the line topologies into high-risk, medium-risk, and other low-risk areas are classified. Targeting an annual flashover rate below 0.4 as the design objective, the configuration schemes of the arresters are progressively optimized. This risk-based approach provides an effective reference framework for differential protection design of distribution line safeguards.


  • Open Access

    Study on the Failure Causes and Improvement Measures of Arresters in 10 kV Distribution Transformer Areas

    by Taishan Hu, Yuanzhi Wu, Zhiming Liao, Gang Liu, Shangmao Hu, Yongxia Han, Lu Qu, Licheng Li

    In recent years, arresters in 10 kV distribution transformer areas of the Guangdong power grid have exhibited a rising trend of premature failures, posing a serious threat to distribution network reliability. This paper studied the failure causes of arresters through performance tests on failed arresters and through deterioration tests on new arresters and their prorated sections under typical operating stresses. The failed arresters and their internal varistors displayed varying degrees of physical damage and pronounced degradation in electrical performance, characterized by a strong polarity effect on the DC reference voltage (U1mA), elevated DC leakage current (IL) and resistive current (iR), and excessive residual voltage (U5kV). In the lightning impulse test, varistors primarily showed pinhole-type damage and significant polarity effects on ΔU1mA. In the AC aging test, ΔU5kV increased markedly. In the water immersion test, varistors exhibited salt deposits and aluminum electrode blackening, with ΔU1mA decreasing, while IL and ΔiR increased significantly. Overall, internal moisture superimposed on other operating stresses was identified as a major internal cause of arrester failure, while pollution flashover of the housing was considered the primary external factor. Corresponding improvement measures in material optimization, testing and inspection, and operation and maintenance are proposed to enhance arrester reliability.


  • Analysis of 2 m Level Gap Flashover Characteristics Under Positive Lightning Impulse

    by Rongrong Wu, Feng Ruifa, Wei Huang, Yi Zhang, Wenping Xu, Shaomin He, Zicai Zhao, Lu Qu

  • Difference Analysis of Lightning Strike Flashover Criterion for 110 kV Insulator with Grading Ring

    by Rongrong Wu, Lu Qu, Wei Huang, Zicai Zhao, Wenping Xu, Ruifa Feng, Shaomin He, Chenhuaifei


  • Open Access

    Branching Morphology of Negative Leaders with Different Propagation Directions in Natural Lightning

    by Yang Liu, Xiankang Wang, Xiaopeng Liu, Lei Liu, Gang Liu, Mingchuan Liao, Lu Qu, Bing Luo, Hansheng Cai, Junjia He, et al.

    Comparing the branching features of negative leaders with different propagation directions could provide insight into the common tendency of development pathways and the formation pattern of branches in natural lightning. This paper reports an upward negative leader (UNL) and a downward negative leader (DNL), and their branching features are analyzed and compared. The UNL is classified into vertical (UNL-V) and horizontal (UNL-H) segments based on propagation directions at different stages. The downward negative leader (DNL) is classified into main (DNL-M) and secondary (DNL-S) channels based on whether the channel is ultimately connected to the upward connecting leader. The vital angle parameters characterizing the branching morphology are investigated. For the strong branch eventually forming a section of the main channel, its deflection angle conforms to the lognormal distribution with a mean range of 22–36°. The included angle between the branches and the deflection angle of weak branches conform to the normal distribution with means close to 40° and 60°, respectively. Moreover, the velocity for four categories of negative leaders decreases noticeably by two or more branching behaviors in a frame interval of about 80 μs. In particular, similarities in branching morphology have been found in UNL-H, UNL-V, and DNL-S, with a semblable distribution in deflection and included angles. Statistical results indicate that branches of DNL-M tend to follow the previous direction of leader development, and the branching behavior has minimal impact on its velocity.


  • Open Access

    Simulation Study on Positive Corona Discharge of Receptors on Rotating Wind Turbine Blade Tips under Thundercloud Electric Fields

    by Lu Qu, Yu Wang, Gang Liu, Minchuan Liao, Hansheng Cai, Tao Zhang, Yeqiang Deng, Xishan Wen

    Recent lightning simulation experiments have not simulated the influence of blade rotation in the long term after corona inception. This study uses a finite element method and considers the adhesion and collision processes of positive ions, aerosol ions, and neutral particles to establish a two-dimensional positive corona discharge model based on a multicomponent diffusion transport equation. The microscopic distribution of these three types of particles and the influence mechanism of charged particles’ migration under electric fields and wind were studied. The results show that ion migration is affected by both electric field and wind speed. The higher the wind speed, the larger is the deviation amplitude of charged particles along the direction of wind. With an increase in wind speed, the corona current on the receptor surface gradually increases. When the wind speed is 30 m/s, the corona current peak value increases by almost six times when compared with that when no wind is present. From this, it can be inferred that blade rotation reduces the concentration of positive ion in the receptor area, thereby facilitating electron avalanche and streamer-leader conversion.