Diego Andrés Campo-Ceballos
Diego Andrés Campo-Ceballos has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Camilo Andrés Villarraga -Solis
1 shared publication- Carlos Alberto Gaviria López
Universidad del Cauca
1 shared publication Daniel Stiven Valencia -Jiménez
1 shared publication- Edgar Mauricio Castillo-Robles
Corporación Universitaria Comfacauca
1 shared publication - Emmanuel Pacheco Rocha Lima
Universidade de Brasília
1 shared publication - Flaminio Levy Neto
Universidade de Brasília
1 shared publication
Latest Publications
- Open Access
- 1 September 2021
- Published by Fundación de Estudios Superiores Comfanorte in Mundo FESC
- Vol. 11 (S2) , 207-223
Design of a low cost podoscope prototype for diagnosing foot pathologies through image processing
El podoscopio es un sistema de alto reflejo de la huella plantar, mediante doble iluminación, tiene una amplia superficie de apoyo para los pies para favorecer un posicionamiento del paciente y permitir un mejor estudio de la patología del pie. En este artículo se presentan los resultados del diseño de un prototipo de podoscopio con el objetivo de permitir el diagnóstico de las patologías del pie por medio del procesamiento de imágenes. El diseño se realizó para un prototipo portátil de una estructura de forma cuadrada que permita sostener la persona sobre este sin ningún problema y así poder analizar las fuerzas plantares. Se utilizó un algoritmo de extracción de características y una interfaz para los usuarios. Se diagnosticó pie cavo, pie plano según el índice de Hernández Corvo.
- 1 September 2021
- Published by Fundación de Estudios Superiores Comfanorte in Mundo FESC
- Vol. 11 (S2) , 207-223
Open AccessDesign of a low cost podoscope prototype for diagnosing foot pathologies through image processing
El podoscopio es un sistema de alto reflejo de la huella plantar, mediante doble iluminación, tiene una amplia superficie de apoyo para los pies para favorecer un posicionamiento del paciente y permitir un mejor estudio de la patología del pie. En este artículo se presentan los resultados del diseño de un prototipo de podoscopio con el objetivo de permitir el diagnóstico de las patologías del pie por medio del procesamiento de imágenes. El diseño se realizó para un prototipo portátil de una estructura de forma cuadrada que permita sostener la persona sobre este sin ningún problema y así poder analizar las fuerzas plantares. Se utilizó un algoritmo de extracción de características y una interfaz para los usuarios. Se diagnosticó pie cavo, pie plano según el índice de Hernández Corvo.
- Open Access
- 22 July 2020
- Published by Universidad Distrital Francisco Jose de Caldas in Visión electrónica
- Vol. 14 (2) , 255-263
Analysis of temperature control effect in fluidized bed coffee roaster
One of the main sources of economic income in Colombia's agricultural sector is the marketing of coffee with a high contribution to the country's economy. However, trends in coffee industry 4.0 show that the coffee roasting process is where more value aggregation is presented and at the same time is one of the most complex because multiple factors are involved such as grain moisture, volume, variety and heat and mass transfer variables. The main objective of this work was to design and implement a fluidized bed system for the study of the effect of temperature control on the physical properties of roasted coffee from Cauca-Colombia. The development of the work was addressed in 4 sequential phases: CAD design, Digital manufacture, temperature control design and the systems analysis. The proposed fluid bed system features a control system for the RoR (rate of rise) that can be adjusted between 3 to 20°C/min, and provide a prediction in the events of the standard roasting profile (Turning Point, Yellow, First Crack, Development time, Second Crack, Drop).
- 22 July 2020
- Published by Universidad Distrital Francisco Jose de Caldas in Visión electrónica
- Vol. 14 (2) , 255-263
Open AccessAnalysis of temperature control effect in fluidized bed coffee roaster
One of the main sources of economic income in Colombia's agricultural sector is the marketing of coffee with a high contribution to the country's economy. However, trends in coffee industry 4.0 show that the coffee roasting process is where more value aggregation is presented and at the same time is one of the most complex because multiple factors are involved such as grain moisture, volume, variety and heat and mass transfer variables. The main objective of this work was to design and implement a fluidized bed system for the study of the effect of temperature control on the physical properties of roasted coffee from Cauca-Colombia. The development of the work was addressed in 4 sequential phases: CAD design, Digital manufacture, temperature control design and the systems analysis. The proposed fluid bed system features a control system for the RoR (rate of rise) that can be adjusted between 3 to 20°C/min, and provide a prediction in the events of the standard roasting profile (Turning Point, Yellow, First Crack, Development time, Second Crack, Drop).
- Open Access
- 1 June 2020
- Published by Insight Society in International Journal on Advanced Science, Engineering and Information Technology
- Vol. 10 (3) , 1107-1116
Analysis of Electric Power Consumption and Proposals for Energy Sustainability for the University of Unicomfacauca (Colombia)
Analysis of Electric Power Consumption and Proposals for Energy Sustainability for the University of Unicomfacauca (Colombia)
- 1 June 2020
- Published by Insight Society in International Journal on Advanced Science, Engineering and Information Technology
- Vol. 10 (3) , 1107-1116
Open AccessAnalysis of Electric Power Consumption and Proposals for Energy Sustainability for the University of Unicomfacauca (Colombia)
Analysis of Electric Power Consumption and Proposals for Energy Sustainability for the University of Unicomfacauca (Colombia)
- Open Access
- 16 December 2019
- Published by Universidad Santo Tomas in ITECKNE
- Vol. 16 (2) , 32-39
Thermomechanical response of a viscoelastic Ni-Ti – Shape Memory Alloy composite beam
This investigation is concerned with the mechanical behavior of Shape Memory Alloy Hybrid Composite Beams (SMAHC), that consist of a circular bar of NiTi alloy incorporated in a 500 mm long cylindrical pipe of polypropylene (PP), with external diameter 50 mm and nominal wall thickness 7 mm, wound with a nylon/epoxy layer. The Ni-Ti alloy was characterized using: scanning electron microscopy (SEM); X-ray diffraction (XRD) and Differential thermal analysis (DSC). The nominal chemical composition of the alloy is 50.05 %Ni / 49.95%Ti, and the softer martensite is the predominant phase at room temperature. The approximate martensite (M) to Austenitic (A) phase transformation temperatures were Mstart = 32°C, Mfinal = 46°C, Astart = 38 °C and Afinal = 60°C. For temperature TAfinal it is fully converted in the Austenitic phase; and its elasticity modulus increases by a factor up to three times. This significant change in stiffness of Ni-Ti, without changing its mass, has motivated the application of such alloy in machine vibration control. The SMAHC beams were subjected to static three-point bending tests, in the elastic regime. Experimental results showed that, in average, at 21°C, the PP pipes effective flexural elastic modulus increased 112%, from 757 MPa to 1609 MPa, when the Ni-Ti bar and the external layer of nylon/epoxy were incorporated to the PP pipe, creating a smart beam. These last results indicate that the SMAHC beam can work as an adaptative structure.
- 16 December 2019
- Published by Universidad Santo Tomas in ITECKNE
- Vol. 16 (2) , 32-39
Open AccessThermomechanical response of a viscoelastic Ni-Ti – Shape Memory Alloy composite beam
This investigation is concerned with the mechanical behavior of Shape Memory Alloy Hybrid Composite Beams (SMAHC), that consist of a circular bar of NiTi alloy incorporated in a 500 mm long cylindrical pipe of polypropylene (PP), with external diameter 50 mm and nominal wall thickness 7 mm, wound with a nylon/epoxy layer. The Ni-Ti alloy was characterized using: scanning electron microscopy (SEM); X-ray diffraction (XRD) and Differential thermal analysis (DSC). The nominal chemical composition of the alloy is 50.05 %Ni / 49.95%Ti, and the softer martensite is the predominant phase at room temperature. The approximate martensite (M) to Austenitic (A) phase transformation temperatures were Mstart = 32°C, Mfinal = 46°C, Astart = 38 °C and Afinal = 60°C. For temperature TAfinal it is fully converted in the Austenitic phase; and its elasticity modulus increases by a factor up to three times. This significant change in stiffness of Ni-Ti, without changing its mass, has motivated the application of such alloy in machine vibration control. The SMAHC beams were subjected to static three-point bending tests, in the elastic regime. Experimental results showed that, in average, at 21°C, the PP pipes effective flexural elastic modulus increased 112%, from 757 MPa to 1609 MPa, when the Ni-Ti bar and the external layer of nylon/epoxy were incorporated to the PP pipe, creating a smart beam. These last results indicate that the SMAHC beam can work as an adaptative structure.
- Open Access
- 13 August 2018
- Published by Universidad Distrital Francisco Jose de Caldas in Visión electrónica
- Vol. 1 (2) , 304-308
Automation of the mechanical tensile and three-point flexural test
This paper presents the design and implementation of Mechanical system testing for tensile and three-point flexural test for both metallic and polymeric materials. A control and monitoring system was adapted to the data, using specialized equipment for industrial automation, i.e. PLC system. Main Parameters to perform the tensile and three point flexural tests, and the functional and technical specifications according to the ASTM (American Society of Testing Materials) standards were defined. Conceptual design, mathematical calculations and CAD designs were developed using Solidworks. Graphical user interfaces (GUI) were designed to interact with the user. Human machine interface (HMI) was implemented in proprietary software and includes rules for the supervision and manipulation of core variables for the user according to the ASTM standard. The HMI was interconnected with a programmable logic controller (PLC) where the process selection rules was implemented in GRAFCET diagram, following the ASTM protocols. The system has a test capacity of 500 Kgf both for the tensile test and for the three-point flexural test, with an accuracy of ± 2%, under the ASTM E177 standard, and the HMI interface as an innovative monitoring and control system.
- 13 August 2018
- Published by Universidad Distrital Francisco Jose de Caldas in Visión electrónica
- Vol. 1 (2) , 304-308
Open AccessAutomation of the mechanical tensile and three-point flexural test
This paper presents the design and implementation of Mechanical system testing for tensile and three-point flexural test for both metallic and polymeric materials. A control and monitoring system was adapted to the data, using specialized equipment for industrial automation, i.e. PLC system. Main Parameters to perform the tensile and three point flexural tests, and the functional and technical specifications according to the ASTM (American Society of Testing Materials) standards were defined. Conceptual design, mathematical calculations and CAD designs were developed using Solidworks. Graphical user interfaces (GUI) were designed to interact with the user. Human machine interface (HMI) was implemented in proprietary software and includes rules for the supervision and manipulation of core variables for the user according to the ASTM standard. The HMI was interconnected with a programmable logic controller (PLC) where the process selection rules was implemented in GRAFCET diagram, following the ASTM protocols. The system has a test capacity of 500 Kgf both for the tensile test and for the three-point flexural test, with an accuracy of ± 2%, under the ASTM E177 standard, and the HMI interface as an innovative monitoring and control system.