  • Effects of Multi-Level Converters on Common-Mode Voltages in Induction Motor Variable Frequency Drives

    by Saleh A. Saleh, Anna Jee, Julian Meng, Nguyen Gia Minh Thao, Sergio Panetta

    Multi-level power electronic converters (ML-PECs) are a new breed of PECs that are constructed using series-connected switching elements to increase their voltage and power ratings. These PECs can offer several advantages, among which is the inherent ability to reduce harmonic distortion at low switching frequencies. Such a feature of ML-PECs can have a direct impact on common-mode voltages (CMVs) and common-mode currents (CMCs), which are experienced by variable frequency motor drives (VFDs). This paper analyzes possible effects of ML-PECs on CMVs and CMCs experienced by induction motor VFDs. The presented analysis aims to relate CMVs and CMCs with the switching frequency and number of levels over a wide range speeds and load torques. The analysis of ML-PECs effects on CMVs and CMCs is conducted using a 50$hp$ induction motor VFD, when operated by 3, 5, and 7 levels diode-clamped ML-PECs. Analysis results show that the inherent abilities of ML-PECs to reduce harmonic distortion can significantly reduce CMVs and CMCs in induction motor VFDs.


  • On the Performance of the Frequency-Selective Grounding in Induction Motor Variable Frequency Drives

    by S. A. Saleh, A. Jee, J. Meng, E. Ozkop, A. Al-Durra, B. Nahid-Mobarakeh, S. Panetta, D. Mohla

    Variable frequency drives (VFDs) are recommended to be grounded in order to support operation continuity, reduce common-mode voltages (CMVs), enhance safety, limit ground fault currents, and minimize transient over-voltages during ground faults. Various standards and industrial codes are developed to address the design and configuration of adequate grounding systems for VFDs. This paper aims to test the performance of a VFD, when featured with the frequency-selective grounding (FSG). The FSG is designed to appear as a very low ground impedance for high frequency ground voltages, and to appear as a low-resistance for low frequency ground voltages. These features of the FSG can offer significant reductions of common-mode voltages (CMVs) in VFDs, thus minimizing their adverse effects on the motor, power electronic converters, and dc-link capacitors. The ability of FSG to minimize CMVs in VFDs is experimentally tested using a 10hp, 3ϕ induction motor VFD for different operating conditions. Experimental test results detailed in this paper demonstrate the significant reductions in CMVs, along with negligible sensitivity to the control of the VFD

  • Impacts of Impedance Grounding on Variable-Frequency Electric Motor Drives

    by S. A. Saleh, A. Jee, J. Meng, E. Ozkop, S. Panetta, D. Mohla, B. Nahid-Mobarakeh

    The grounding system for a variable-frequency electric motor drive (VFD) is typically designed to enhance the continuity of operation, limit ground fault currents, limit transient over-voltages during ground faults, improve safety, and reduce or eliminate common-mode voltages (CMVs). The majority of VFDs utilize power transformers to provide isolation between the VFD and its supply, and operate as the point-of-supply to the front-ac-dc power electronic converter (PEC). Grounding system designs for VFDs have been a subject of several standards, industrial codes, and recommended practices. This paper analyzes the performance of impedance grounding systems (during steady-state and fault conditions), when utilized in VFDs. Analyzed grounding systems are the low-resistance, and high-resistance grounding systems. The performance of analyzed grounding systems is evaluated based ground currents, ground potential, and CMVs. Several experimental tests are also conducted to draw conclusions and suggest recommendations for an adequate impedance grounding for industrial VFDs.


  • Experimental Assessment of Ground Fault Protection in Frequency-Selective Grounded Systems Fed by a Single Transformer

    by S. A. Saleh, E. Ozkop, M. E. Valdes, A. Yuksel, D. Jewett, A. Al-Durra, J. Meng, S. A. R. Panetta

    This paper presents performance assessment of ground fault protection for systems supplied by a transformer, which has frequency-selective grounding. Frequency-selective grounding is a new grounding system that is designed to act as a solid-grounding for high frequency currents, and as a low resistance-grounding for low frequency currents. This grounding system is composed from a parallel $R-C$ circuit with an equivalent impedance able to affect system zero-sequence currents and ground potentials. Such effects on zero-sequence currents and ground potentials can directly impact the accuracy and response speed of ground fault protection. Effects of frequency-selective grounding on ground fault protection are experimentally assessed for different fault and non-fault events, when the transformer supplies linear and non-liner loads. Experimental results demonstrate responses of various implementations of ground fault protection to fault and non-fault events, when the protected system has frequency selective grounding. Moreover, presented results and discussions aim to demonstrate the ability of frequency-selective grounding to support the operation of ground fault protection during different loading conditions and fault events.


  • Testing Ground Fault Protection of Generating Units With Frequency-Selective Grounding

    by S. A. Saleh, Razzaqul Ahshan, Marcelo E. Valdes, Danielle Jewett, Claudio S. Mardegan, Julian Meng, Sergio A. R. Panetta

    This paper experimentally evaluates responses of ground fault protection for synchronous generators, which are grounded using frequency-selective grounding. Frequency-selective grounding is designed to provide a low ground impedance path (similar to solid grounding) for high frequency zero-sequence current components. This grounding system also provides an impedance similar to a low-resistance grounding for low frequency zero-sequence current components. The frequency-dependent equivalent impedance of frequency-selective grounding can affect ground potential and current, which are typically used as inputs for ground fault protective relays. Effects of frequency-selective grounding on ground fault protection are experimentally evaluated using a 7.5 kVA synchronous generator. Experimental tests are conducted for different implementations of ground fault protection, when responding to fault and non-fault events. Evaluation results detailed in this paper demonstrate the negligible effects of frequency-selective grounding on responses of different ground fault protective relays.


  • Ground Fault Protection of Synchronous Generators with Frequency-Selective Grounding

    by S. Saleh, D. Jewett, J. Meng, M. Valdes, R. Ahshan, S. Panetta, C. Mardegan

    This paper experimentally evaluates responses of ground fault protection for synchronous generators, which are grounded using frequency-selective grounding. Frequency-selective grounding is designed to provide a low ground impedance path (similar to solid grounding) for high frequency zero-sequence current components. This grounding system also provides an impedance similar to a low-resistance grounding for low frequency zero-sequence current components. The frequency-dependent equivalent impedance of frequency-selective grounding can affect ground potential and current, which are typically used as inputs for ground fault protective relays. Effects of frequency-selective grounding on ground fault protection are experimentally evaluated using a 7.5 kVA synchronous generator. Experimental tests are conducted for different implementations of ground fault protection, when responding to fault and non-fault events. Evaluation results detailed in this paper demonstrate the negligible effects of frequency-selective grounding on responses of different ground fault protection relays.

  • Ground Fault Protection in Frequency-Selective Grounded Systems Fed by a Single Transformer

    by S. Saleh, D. Jewett, J. Meng, M. Valdes, E. Ozkop, A. Yuksel, A. Al-Durra, S. Panetta

    This paper presents experimental results for performance tests of ground fault protection schemes applied to a frequency-selective grounded system supplied by a single transformer. Frequency selective grounding systems are designed to present low ground impedance (similar to solid grounding) to high frequency zero-sequence current components and impedance like that of a low-impedance grounded system to fundamental zero-sequence components. The variable impedance of the grounding scheme can impact the response of ground fault protection in terms of accuracy and timing. The laboratory setup includes a single 35kVa 3-phase source transformer with a 340/208-volt secondary voltage. Experimental results detailed in this paper demonstrate the response that may be expected of various types of GFP schemes under fault and non-fault events and conditions.

  • Evaluating the Impacts of Grounding Systems on Ground Currents and Transient Overvoltage

    by Saleh A. Saleh, Danielle Jewett, Ahmed Al-Durra, Saikrishna Kanukollu, Julian Luciano Cardenas, Marcelo E. Valdes, Sergio A. R. Panetta

    This article presents a performance comparison of the solid, low impedance, high impedance, frequency-selective, and isolated grounding systems. A grounding system (for any power system component) is designed as an impedance ( $\bar{Z}_{G}$ ) that connects the neutral point to the ground. The impedance $\bar{Z}_{G}$ is constructed using a combination of $R$ , $L$ , and $C$ elements. The values and combination type (series or parallel) of $R$ , $L$ , and $C$ determine the possible influence of $\bar{Z}_{G}$ on ground currents and potentials. Each grounding system is related to a system voltages level, a specific combination of $R$ , $L$ , and $C$ , and a range of $R$ , $L$ , and $C$ values. The solid, low impedance, high impedance, frequency-selective, and isolated grounding systems are designed for a $3\phi$ transformer and a $3\phi$ synchronous generator in order to compare their influences on ground currents and potentials during ground faults. The transformer and generator are tested for line-to-ground and double line-to-ground faults with all designed grounding systems. Test results show that some grounding systems can reduce ground currents only, while others can reduce ground potentials only. Such capabilities can be used to fulfill certain system and operation requirements (e.g., service continuity, ground capacity, etc.).


  • Experimental Assessment of Grounding System Impacts on Ground Currents and Transient Overvoltage

    by Saleh A. Saleh, Danielle Jewett, Ahmed Al-Durra, Saikrishna Kanukollu, Julian Cardenas-Barrera, Marcelo E. Valdes, Julian Meng, Sergio A. R. Panetta

    In this article, experimental performance assessment and comparison are presented for solid, low impedance, high impedance, frequency-selective, and isolated grounding (IG) systems. The typical design of a grounding system (for low and medium voltage generation, transmission, and distribution systems) is based on selecting an impedance ( $\bar{Z}_{G}$ ), which is used to connect the neutral point and the ground. The impedance $\bar{Z}_{G}$ is typically composed from a combination of $R$ , $L$ , and $C$ elements. The combination type (series or parallel), along with the values of $R$ , $L$ , $C$ elements, allow estimating the possible effects of $\bar{Z}_{G}$ on ground currents and potentials during ground faults. In this article, solid, low impedance, high impedance, frequency-selective, and IG systems are designed for a 35-kVA $3\phi$ transformer and a 5-kVA $3\phi$ synchronous generator, for purposes of assessing and comparing their effects on ground currents and potentials during ground faults. The laboratory transformer and generator are tested for line-to-ground and double line-to-ground faults with all designed grounding systems under different loading levels. Experimental results show that some grounding systems can effectively reduce ground currents, and other grounding systems can effectively reduce ground potentials. These capabilities and features can be used to achieve certain system and operation mandates, including ground capacity, maximum allowed overvoltage, and service continuity.


  • The Analysis, Modeling, and Capabilities of Grounding System Designs

    by S. A. Saleh, Danielle Jewett, Sergio A. R. Panetta

    The selection of a grounding configuration and design of a grounding impedance is of vital importance for the stability and functionality of power systems, including industrial and commercial power systems. These key aspects of grounding systems have been the subject of various standards, industrial codes, and recommended practices. In this article, a review, modeling, and analysis of different grounding system designs are provided. The different grounding system design discussed in this article is compared in terms of the ground potential, ground currents, and overvoltage during ground faults. The various grounding system designs are implemented for power systems components in order to assess their capabilities and performance. Several tests are conducted for ground faults, when different grounding system designs are used. Test results show that some grounding system design can limit ground currents, with minor effects on ground potentials. Other grounding system design can limit ground potentials, while fail to limit ground currents.