RKRajendra Kumar

Rajendra Kumar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rajendra Kumar has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Two-Dimensional Local Thermal Equilibrium Model for Capturing Thermocline Dynamics in Packed Bed Cryogenic Energy Recovery Systems

    by Rajendra Kumar, Pavitra Sandilya, Bharat Surya Chamarthi

    The performance of a packed-bed cryogenic energy recovery system (PB-CERS) has been studied for storing and reusing the waste cold generated during the regasification of various liquid cryogens. Various numerical approaches, such as local thermal equilibrium (LTE) and local thermal non-equilibrium (LTNE), are used to study PB-CERS. We adopted an LTE approach for our study. We validated our model at both cryogenic and non-cryogenic conditions. This study demonstrated, for the first time, the applicability of a 2D-LTE model to predicting the performance of a PB-CERS during the charging-standby-discharging operation. Using the validated model, we performed parametric analyses of charging and discharging operations at Peclet numbers of 32540 to 65080, respectively, across packed-bed aspect ratios ranging from 2.29 to 4.57. The results reveal that during the charging operation, higher Peclet numbers and longer beds are desirable; however, the pressure drop penalty also increases at higher flow rates and for longer packed beds. Further, the temperature contours of the PB-CERS show that the thermocline in the near-wall region propagates faster than that at the centre of the packed bed. Moreover, when diffusion starts to dominate as the Peclet number decreases, the packed bed is under-utilised and significant losses occur. Furthermore, the developed 2D-LTE model can predict the state of charge of the PB-CERS. Hence, the LTE modelling approach should be sufficient for the PB-CERS (quartz-air system) between 115 K and 300 K at sub-ambient pressures to predict thermocline behaviour. Thus, the proposed model can be used to design PB-CERS for sensible heat storage and can be further explored with phase-change materials.

  • Open Access

    Numerical Evaluation of Packed Bed Cryogenic Energy Recovery System Using a Two-Dimensional Local Thermal Equilibrium Model

    by Rajendra Kumar, Bharat Surya Chamarthi, Pavitra Sandilya

    A packed-bed cryogenic energy recovery system (PB-CERS) is used to recover the waste cold generated during the regasification of various cryogens and store it for later use for different refrigeration/cold applications. Such systems have been studied extensively using various numerical approaches, like local thermal equilibrium (LTE) and local thermal non-equilibrium (LTNE). For the first time, this work attempts to assess the applicability of a 2D-LTE model for predicting the performance of a PB-CERS operating cyclically in charging-standby-discharging mode. The model was validated at both cryogenic and non-cryogenic conditions. Using the validated model, we performed parametric analyses of charging and discharging operations at Peclet numbers ranging from 32540 to 78097 and from 32540 to 65080, respectively, across packed-bed aspect ratios of 2.29, 3.50, and 4.57. Further, we performed thermodynamic analysis of the energy recovery efficiency of the PB-CERS. Our study showed that the cooling rate of the PB-CERS increased, while the charging efficiency decreased from 86% to 74% as the Peclet number increased from 32540 to 65080. During the discharging operation, the duration of cold energy recovery from PB-CERS and discharge efficiency increase with increasing Peclet number. It was found that increasing the aspect ratio increased both charging and discharging efficiencies. It was also observed that a longer standby period deteriorates the discharge efficiency of the PB-CERS. In our study, the amount of cold recovered at the end of discharge decreased by 8% when a 2-hour standby period was considered. Thus, the proposed model can be used to design PB-CERS for sensible heat storage and can be further explored with phase-change materials.

  • Open Access

    Exploring the Validity of the Local Thermal Equilibrium Model in Packed Bed Cryogenic Energy Recovery Systems

    by Pavitra Sandilya, Rajendra Kumar

    Packed beds are commonly used for cold energy recovery during LNG regasification for various cold or refrigeration applications. We studied the packed-bed cryogenic energy storage system (PB-CERS) using 2D-CFD technique. We adopted and verified the LTE model’s applicability to predict CERS performance. Parametric analyses were performed for the charging operation at Peclet numbers ranging from 32540 to 78097 and for the discharging operation at Peclet numbers ranging from 32540 to 65080, with various packed bed aspect ratios. PB-CERS exhibited higher cooling and more stable outlet temperatures during charging. The thermocline thickness exhibited non-linear behaviour during charging. During the discharging operation, it was observed that the duration of cold energy recovery from PB-CERS increased with Peclet number. With an aspect ratio of 4.57, PB-CERS provided the cold energy for the longest duration during the charging operation. The thickness of the thermocline increased and then decreased over time during the charging operation for aspect ratios of 3.50 and 4.57. However, this typical behaviour was not observed in PB-CERS during discharging in the selected range of Peclet numbers. The proposed model can be used to design PB-CERS for sensible heat storage.

  • Open Access

    Numerical Simulation of Magnetic Field Effect on Cryocooler Regenerators: Temperature Distribution

    by Rajendra Kumar, Sumit Shoor

    Regenerative types of cryogenic refrigerators (or cryocoolers) employ magnetic intermetallic compounds of 3d and 4f elements to work well below 10 K. This paper presents the analysis of temperature distribution in regenerators of such cryocoolers under the influence of magnetic fields of 1 T, 3 T, and 4.3 T. Commercial code of finite element analysis (FEA) package, ANSYS (APDL) 14.5, is used to investigate the temperature distribution under above-mentioned fields. Er3Ni is selected as regenerator material and the criteria for its selection are discussed in detail. The cold end temperature is varied from 4.2 K to 10 K and hot end temperature is fixed at 20 K. The values obtained from FEA clearly show that the ineffectiveness of Er3Ni is at 8 K and 10 K at 3 T and 4.3 T.