Pavitra Sandilya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Pavitra Sandilya has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Goutam Chakraborty
6 shared publications- Baby Nitin
Systems Engineer, Airbus India Private Limited Bengaluru India
4 shared publications - Bharat Surya Chamarthi3 shared publications
Pritam Saha
Cryogenic Engineering Centre, Indian Institute of Technology Kharagpur
3 shared publications- Rajendra Kumar
School of Mechanical Engineering, Lovely Professional University, Phagwara, Punjab 144411, India
3 shared publications B Nitin
Cryogenic Engineering Centre, Indian Institute of Technology Kharagpur, India
2 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by Elsevier in SSRN Electronic Journal
A Two-Dimensional Local Thermal Equilibrium Model for Capturing Thermocline Dynamics in Packed Bed Cryogenic Energy Recovery Systems
The performance of a packed-bed cryogenic energy recovery system (PB-CERS) has been studied for storing and reusing the waste cold generated during the regasification of various liquid cryogens. Various numerical approaches, such as local thermal equilibrium (LTE) and local thermal non-equilibrium (LTNE), are used to study PB-CERS. We adopted an LTE approach for our study. We validated our model at both cryogenic and non-cryogenic conditions. This study demonstrated, for the first time, the applicability of a 2D-LTE model to predicting the performance of a PB-CERS during the charging-standby-discharging operation. Using the validated model, we performed parametric analyses of charging and discharging operations at Peclet numbers of 32540 to 65080, respectively, across packed-bed aspect ratios ranging from 2.29 to 4.57. The results reveal that during the charging operation, higher Peclet numbers and longer beds are desirable; however, the pressure drop penalty also increases at higher flow rates and for longer packed beds. Further, the temperature contours of the PB-CERS show that the thermocline in the near-wall region propagates faster than that at the centre of the packed bed. Moreover, when diffusion starts to dominate as the Peclet number decreases, the packed bed is under-utilised and significant losses occur. Furthermore, the developed 2D-LTE model can predict the state of charge of the PB-CERS. Hence, the LTE modelling approach should be sufficient for the PB-CERS (quartz-air system) between 115 K and 300 K at sub-ambient pressures to predict thermocline behaviour. Thus, the proposed model can be used to design PB-CERS for sensible heat storage and can be further explored with phase-change materials.
- 1 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Two-Dimensional Local Thermal Equilibrium Model for Capturing Thermocline Dynamics in Packed Bed Cryogenic Energy Recovery Systems
The performance of a packed-bed cryogenic energy recovery system (PB-CERS) has been studied for storing and reusing the waste cold generated during the regasification of various liquid cryogens. Various numerical approaches, such as local thermal equilibrium (LTE) and local thermal non-equilibrium (LTNE), are used to study PB-CERS. We adopted an LTE approach for our study. We validated our model at both cryogenic and non-cryogenic conditions. This study demonstrated, for the first time, the applicability of a 2D-LTE model to predicting the performance of a PB-CERS during the charging-standby-discharging operation. Using the validated model, we performed parametric analyses of charging and discharging operations at Peclet numbers of 32540 to 65080, respectively, across packed-bed aspect ratios ranging from 2.29 to 4.57. The results reveal that during the charging operation, higher Peclet numbers and longer beds are desirable; however, the pressure drop penalty also increases at higher flow rates and for longer packed beds. Further, the temperature contours of the PB-CERS show that the thermocline in the near-wall region propagates faster than that at the centre of the packed bed. Moreover, when diffusion starts to dominate as the Peclet number decreases, the packed bed is under-utilised and significant losses occur. Furthermore, the developed 2D-LTE model can predict the state of charge of the PB-CERS. Hence, the LTE modelling approach should be sufficient for the PB-CERS (quartz-air system) between 115 K and 300 K at sub-ambient pressures to predict thermocline behaviour. Thus, the proposed model can be used to design PB-CERS for sensible heat storage and can be further explored with phase-change materials.
- Open Access
- 11 August 2026
- Published by Elsevier in SSRN Electronic Journal
A Numerical Investigation on the Applicability of Various Rate Qquations to Predict Boil-Off Characteristics of Liquid Cryogens
Cryogenic tanks undergo self-pressurization because unavoidable heat ingress generates boil-off vapour at the liquid-vapour interface. The predicted pressure rise depends strongly on the phase-change closure used to estimate the interfacial mass flux. This work compares Lee, modified Hertz-Knudsen-Schrage (HKS) model, statistical rate theory (SRT), transition state theory (TST) and Bedeaux-Albano-Mazur (BAM) closures within a common one-dimensional two-fluid/VOF-based framework for liquid nitrogen boil-off. The same geometry, initial condition, boundary condition and numerical algorithm are used for all models. The results are compared against the pressure-transient data of Seo and Jeong. Lee and HKS-type closures overpredict the pressure rise because the kinetic mass flux is not sufficiently restricted by interfacial heat availability. BAM, TST and SRT give bounded pressure responses, indicating the importance of non-equilibrium interfacial resistance and heat-limited mass transfer in cryogenic boil-off prediction.
- 11 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Numerical Investigation on the Applicability of Various Rate Qquations to Predict Boil-Off Characteristics of Liquid Cryogens
Cryogenic tanks undergo self-pressurization because unavoidable heat ingress generates boil-off vapour at the liquid-vapour interface. The predicted pressure rise depends strongly on the phase-change closure used to estimate the interfacial mass flux. This work compares Lee, modified Hertz-Knudsen-Schrage (HKS) model, statistical rate theory (SRT), transition state theory (TST) and Bedeaux-Albano-Mazur (BAM) closures within a common one-dimensional two-fluid/VOF-based framework for liquid nitrogen boil-off. The same geometry, initial condition, boundary condition and numerical algorithm are used for all models. The results are compared against the pressure-transient data of Seo and Jeong. Lee and HKS-type closures overpredict the pressure rise because the kinetic mass flux is not sufficiently restricted by interfacial heat availability. BAM, TST and SRT give bounded pressure responses, indicating the importance of non-equilibrium interfacial resistance and heat-limited mass transfer in cryogenic boil-off prediction.
- 15 June 2026
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 40 (25) , 13409-13427
Unveiling Supercritical CO 2 and CH 4 Uptake Mechanisms in Natural and Acid-Treated Clays through Advanced Six-Parameter SLD Analysis
- 15 June 2026
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 40 (25) , 13409-13427
Unveiling Supercritical CO 2 and CH 4 Uptake Mechanisms in Natural and Acid-Treated Clays through Advanced Six-Parameter SLD Analysis
- 14 May 2026
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 40 (21) , 11384-11396
Parametric Investigation of Continuous Desublimation-Based Cryogenic Carbon Capture in a Cryogenically Cooled Cyclone Separator
- 14 May 2026
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 40 (21) , 11384-11396
Parametric Investigation of Continuous Desublimation-Based Cryogenic Carbon Capture in a Cryogenically Cooled Cyclone Separator
- 1 May 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (5)
Low-Reynolds-number turbulence with active vortex stretching in three-dimensional cryogenic sloshing
Two-dimensional simulations of liquid sloshing underpredict damping by two orders of magnitude. This long-standing discrepancy is traced here to the structure of the energy cascade. Using three-dimensional volume-of-fluid simulations of liquefied natural gas (LNG) sloshing (in a Basilisk framework, up to 5123 effective resolution), we show that the flow occupies a previously uncharacterized regime: an active vortex stretching (ratio 2.67) at a Taylor-scale Reynolds number Reλ∼50–80 (measured directly via multi-scale variance decomposition separating turbulent fluctuations from organized sloshing), below the inertial-range threshold. We prove that both vortex stretching and strain-rate self-amplification (SSA) are the two mechanisms driving the forward energy cascade. The mechanisms vanish identically in two dimensions, establishing a fundamental, not merely quantitative, origin for the simulation failure. Direct measurement of the SSA-to-stretching ratio (3.24±1.22, consistent with the Betchov identity and the Carbone–Bragg prediction of ∼3) confirms that cascade physics operates at these low Reynolds numbers. Second-order velocity structure functions computed from the adaptive mesh refinement data show no inertial plateau, providing direct real-space spectral evidence for the sub-inertial classification. Free-decay analysis reveals anisotropic damping spanning three orders of magnitude with irreducible three-dimensional coupling (R=0.14–0.18,dynamic forces). Under Froude scaling, boundary-layer damping vanishes at the prototype scale (ζBL∼λ−3/4) while cascade damping remains scale-independent (ζ3D∼λ0), with direct implications for full-scale LNG damping prediction.
- 1 May 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (5)
Low-Reynolds-number turbulence with active vortex stretching in three-dimensional cryogenic sloshing
Two-dimensional simulations of liquid sloshing underpredict damping by two orders of magnitude. This long-standing discrepancy is traced here to the structure of the energy cascade. Using three-dimensional volume-of-fluid simulations of liquefied natural gas (LNG) sloshing (in a Basilisk framework, up to 5123 effective resolution), we show that the flow occupies a previously uncharacterized regime: an active vortex stretching (ratio 2.67) at a Taylor-scale Reynolds number Reλ∼50–80 (measured directly via multi-scale variance decomposition separating turbulent fluctuations from organized sloshing), below the inertial-range threshold. We prove that both vortex stretching and strain-rate self-amplification (SSA) are the two mechanisms driving the forward energy cascade. The mechanisms vanish identically in two dimensions, establishing a fundamental, not merely quantitative, origin for the simulation failure. Direct measurement of the SSA-to-stretching ratio (3.24±1.22, consistent with the Betchov identity and the Carbone–Bragg prediction of ∼3) confirms that cascade physics operates at these low Reynolds numbers. Second-order velocity structure functions computed from the adaptive mesh refinement data show no inertial plateau, providing direct real-space spectral evidence for the sub-inertial classification. Free-decay analysis reveals anisotropic damping spanning three orders of magnitude with irreducible three-dimensional coupling (R=0.14–0.18,dynamic forces). Under Froude scaling, boundary-layer damping vanishes at the prototype scale (ζBL∼λ−3/4) while cascade damping remains scale-independent (ζ3D∼λ0), with direct implications for full-scale LNG damping prediction.
- Open Access
- 28 April 2026
- Published by Elsevier in SSRN Electronic Journal
Numerical Evaluation of Packed Bed Cryogenic Energy Recovery System Using a Two-Dimensional Local Thermal Equilibrium Model
A packed-bed cryogenic energy recovery system (PB-CERS) is used to recover the waste cold generated during the regasification of various cryogens and store it for later use for different refrigeration/cold applications. Such systems have been studied extensively using various numerical approaches, like local thermal equilibrium (LTE) and local thermal non-equilibrium (LTNE). For the first time, this work attempts to assess the applicability of a 2D-LTE model for predicting the performance of a PB-CERS operating cyclically in charging-standby-discharging mode. The model was validated at both cryogenic and non-cryogenic conditions. Using the validated model, we performed parametric analyses of charging and discharging operations at Peclet numbers ranging from 32540 to 78097 and from 32540 to 65080, respectively, across packed-bed aspect ratios of 2.29, 3.50, and 4.57. Further, we performed thermodynamic analysis of the energy recovery efficiency of the PB-CERS. Our study showed that the cooling rate of the PB-CERS increased, while the charging efficiency decreased from 86% to 74% as the Peclet number increased from 32540 to 65080. During the discharging operation, the duration of cold energy recovery from PB-CERS and discharge efficiency increase with increasing Peclet number. It was found that increasing the aspect ratio increased both charging and discharging efficiencies. It was also observed that a longer standby period deteriorates the discharge efficiency of the PB-CERS. In our study, the amount of cold recovered at the end of discharge decreased by 8% when a 2-hour standby period was considered. Thus, the proposed model can be used to design PB-CERS for sensible heat storage and can be further explored with phase-change materials.
- 28 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessNumerical Evaluation of Packed Bed Cryogenic Energy Recovery System Using a Two-Dimensional Local Thermal Equilibrium Model
A packed-bed cryogenic energy recovery system (PB-CERS) is used to recover the waste cold generated during the regasification of various cryogens and store it for later use for different refrigeration/cold applications. Such systems have been studied extensively using various numerical approaches, like local thermal equilibrium (LTE) and local thermal non-equilibrium (LTNE). For the first time, this work attempts to assess the applicability of a 2D-LTE model for predicting the performance of a PB-CERS operating cyclically in charging-standby-discharging mode. The model was validated at both cryogenic and non-cryogenic conditions. Using the validated model, we performed parametric analyses of charging and discharging operations at Peclet numbers ranging from 32540 to 78097 and from 32540 to 65080, respectively, across packed-bed aspect ratios of 2.29, 3.50, and 4.57. Further, we performed thermodynamic analysis of the energy recovery efficiency of the PB-CERS. Our study showed that the cooling rate of the PB-CERS increased, while the charging efficiency decreased from 86% to 74% as the Peclet number increased from 32540 to 65080. During the discharging operation, the duration of cold energy recovery from PB-CERS and discharge efficiency increase with increasing Peclet number. It was found that increasing the aspect ratio increased both charging and discharging efficiencies. It was also observed that a longer standby period deteriorates the discharge efficiency of the PB-CERS. In our study, the amount of cold recovered at the end of discharge decreased by 8% when a 2-hour standby period was considered. Thus, the proposed model can be used to design PB-CERS for sensible heat storage and can be further explored with phase-change materials.
- Open Access
- 23 February 2026
- Published by Elsevier in SSRN Electronic Journal
Exploring the Validity of the Local Thermal Equilibrium Model in Packed Bed Cryogenic Energy Recovery Systems
Packed beds are commonly used for cold energy recovery during LNG regasification for various cold or refrigeration applications. We studied the packed-bed cryogenic energy storage system (PB-CERS) using 2D-CFD technique. We adopted and verified the LTE model’s applicability to predict CERS performance. Parametric analyses were performed for the charging operation at Peclet numbers ranging from 32540 to 78097 and for the discharging operation at Peclet numbers ranging from 32540 to 65080, with various packed bed aspect ratios. PB-CERS exhibited higher cooling and more stable outlet temperatures during charging. The thermocline thickness exhibited non-linear behaviour during charging. During the discharging operation, it was observed that the duration of cold energy recovery from PB-CERS increased with Peclet number. With an aspect ratio of 4.57, PB-CERS provided the cold energy for the longest duration during the charging operation. The thickness of the thermocline increased and then decreased over time during the charging operation for aspect ratios of 3.50 and 4.57. However, this typical behaviour was not observed in PB-CERS during discharging in the selected range of Peclet numbers. The proposed model can be used to design PB-CERS for sensible heat storage.
- 23 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessExploring the Validity of the Local Thermal Equilibrium Model in Packed Bed Cryogenic Energy Recovery Systems
Packed beds are commonly used for cold energy recovery during LNG regasification for various cold or refrigeration applications. We studied the packed-bed cryogenic energy storage system (PB-CERS) using 2D-CFD technique. We adopted and verified the LTE model’s applicability to predict CERS performance. Parametric analyses were performed for the charging operation at Peclet numbers ranging from 32540 to 78097 and for the discharging operation at Peclet numbers ranging from 32540 to 65080, with various packed bed aspect ratios. PB-CERS exhibited higher cooling and more stable outlet temperatures during charging. The thermocline thickness exhibited non-linear behaviour during charging. During the discharging operation, it was observed that the duration of cold energy recovery from PB-CERS increased with Peclet number. With an aspect ratio of 4.57, PB-CERS provided the cold energy for the longest duration during the charging operation. The thickness of the thermocline increased and then decreased over time during the charging operation for aspect ratios of 3.50 and 4.57. However, this typical behaviour was not observed in PB-CERS during discharging in the selected range of Peclet numbers. The proposed model can be used to design PB-CERS for sensible heat storage.
- 3 December 2025
- Published by Elsevier in Journal of Energy Storage
- Vol. 143
A multi criteria decision analysis to select phase change material for packed bed cryogenic energy recovery systems
- 3 December 2025
- Published by Elsevier in Journal of Energy Storage
- Vol. 143
A multi criteria decision analysis to select phase change material for packed bed cryogenic energy recovery systems
- Open Access
- 11 November 2025
- Published by Association for Computing Machinery (ACM)
- p. 471-476
AI-enabled phase equilibrium prediction in cryogenic DAC for sustainable built environments
- 11 November 2025
- Published by Association for Computing Machinery (ACM)
- p. 471-476
Open AccessAI-enabled phase equilibrium prediction in cryogenic DAC for sustainable built environments
- 17 February 2023
- Published by Elsevier in International Journal of Refrigeration
- Vol. 150, 125-134
Experimental evidence of enhanced boil-off in isobaric mobile cryogenic vessels
- 17 February 2023
- Published by Elsevier in International Journal of Refrigeration
- Vol. 150, 125-134
Experimental evidence of enhanced boil-off in isobaric mobile cryogenic vessels