MNMohd Norzaidi Mat Nawi

Mohd Norzaidi Mat Nawi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mohd Norzaidi Mat Nawi has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A flexible paper based strain sensors drawn by pencil for low-cost pressure sensing applications

    by Mohd Norzaidi Mat Nawi, Jim Tze Ho Lau

    Paper-based strain sensors, offering a cost-effective and environmentally friendly solution, are in demand for pressure sensing applications. Here, we present a simple sensor design comprising a piece of paper, a graphite pencil, and a copper plate. The proposed fabrication process is simple and eco-friendly. Beyond design and fabrication, our study explores the performance of paper-based sensors in effectively measuring and monitoring pressure changes induced by varying deflection angles. Our findings show that as the deflection angle increases, the sensor exhibits a proportional increase in the relative change in resistance. Furthermore, the practical applicability of the fabricated sensor is demonstrated through real-world testing on a human finger, considering different positions. In essence, our research positions paper-based strain sensors as a promising and practical choice for affordable, eco-friendly, and responsive pressure sensing.


  • Open Access

    Development and Usability of the Specific Heat Capacity Application Kit Among Form 4 Students

    by Mohd Norzaidi Mat Nawi

    This study aims to develop an application kit for the specific heat capacity subtopic of the topic of heat and assess the degree of usefulness of the application kit for specific heat capacity among form four students in Malaysia. This development design study based on constructivism theory uses the ADDIE model. A total of 36 Form 4 students were chosen as research participants using a simple random sample procedure to assess the usability level of the application kit. The study tool utilized is a 4-point Likert scale expert validity assessment form and a research question form on the usability of the Specific Heat Capacity Application Kit. The expert approval percentage approach is used to assess expert validity. The Cronbach Alpha reliability coefficient was calculated using the Statistical Package for the Social Sciences (SPSS) software, and the data for the usability study questions were analyzed using descriptive statistical analysis to determine the mean value and standard deviation. The study's findings revealed that the expert approval value for the application kit and instrument was high, with 95.5% and 97.5%, respectively. It received a high dependability rating of 0.82 for the research instrument. The findings also revealed that the application kit is entirely usable (M = 3.84, SP = 0.36). As a result, this application kit is appropriate for use as teaching and learning material for the Form 4 subtopic of specific heat capacity. This application kit will aid in the development of a more active and two-way learning environment between the learner and the instructor, as well as improve the learner's comprehension of the Specific Heat Capacity subtopic.

  • Open Access

    The Development and Perception of Trainee Teachers towards Smartphone Based Free Fall Measurement Kit Using Arduino

    by Syahmina Mokhdzir, Mohd Norzaidi Mat Nawi

    Free fall motion is one of the topics that is always considered challenging for Physics Students. The lack of teaching aids concerning this topic is also why students are less exposed to the free fall concept. Thus, this study aims to develop a Free Fall Kit as a teaching aid for the Physics Form Four under the subtopic Free Fall Movement. This kit is developed using an Arduino microcontroller where the result of gravitational acceleration will be displayed on the smartphone through the Bluetooth module. This study also aims to test the trainee teacher’s perceptions of majoring in physics at Universiti Pendidikan Sultan Idris towards the Free Fall Kit. The validity study was conducted with three experts among the physics lecturers at the Sultan Idris University of Education. These validity data were analyzed using the Percentage of Consent. The validity value obtained showed a high value where the total percentage of validity agreement from the three experts was 98.3% for face validity and 93.3% for content validity. This study uses a descriptive method to assess the instrument reliability and respondents perceptions of the developed kits. The data obtained showed that Cronbach’s Alpha value is 0.97, while an average mean score is 3.82 and an average standard deviation value is 0.28, indicating that the level of reliability and perception is at a high level of agreement among the respondents. In conclusion, the Free Fall Kit has a good perception among trainee teachers at Universiti Pendidikan Sultan Idris and has achieved the objectives of this research. The implication is that the Free Fall Kit can be an alternative teaching aid for teachers to teach the subtopic of free fall motion to determine the value of gravitational acceleration.

  • Development and characterization of fluidic based dome-shaped pressure sensor using spiral microchannel

    by Nur Shahira Shahripul Azeman, Mohd Norzaidi Mat Nawi, Mohd Ikhwan Hadi Yaacob


  • One-Side-Electrode-Type Fluidic-Based Capacitive Pressure Sensor

    by Mohd Norzaidi Mat Nawi, Asrulnizam Abd Manaf, Mohamad Faizal Abd Rahman, Mohd Rizal Arshad, Othman Sidek

    This paper presents the development of a novel one-side-electrode-type fluidic-based capacitive pressure sensor. A pressure sensor using a one-side-electrode and an implementation of electrical double layer capacitance concept was proposed. Mechanical analysis of the membrane was carried out using the finite-element analysis in terms of deflection and Mises stress. A sensor with a circular membrane radius of 3.2 mm, membrane thickness of 0.8 mm, microchannel thickness of 0.5 mm, and microchannel width of 0.5 mm was fabricated using polydimethylsiloxane. The validation was made between the analytical and experimental results for fluid mechanisms inside the sensor. This showed that the displacement for all types of liquid, including methanol, ethanol, and silicon oil was linearly aligned. Methanol was chosen as an electrolyte due to its liquid properties, such as low surface tension and dielectric permittivity. From the experimental results, the operating frequency, response time, and sensitivity of the sensor were 1.2 kHz, 0.12 s, and 0.77 pF/kPa, respectively. The effects of vibration, temperature, and lifetime were also discussed in this paper.


  • Fabrication Techniques for PDMS Dome-Shaped Membrane Using Soft Lithography Process

    by Mohd Norzaidi Mat Nawi, Asrulnizam Abd Manaf, Mohd Rizal Arshad, Othman Sidek

    The dome-shaped membrane is very important part of the micro/nano devices. The dome-shaped with the thickness of 150 μm and a radius of 3.2 mm was fabricated using the soft lithography process. The Polydimethylsiloxane (PDMS) was selected as a material because it deformable and suitable to implement as a membrane. Soft lithography is based on pattern transfer using a mold that is patterning the substrate material. In this paper, two techniques were suggested to fabricate the dome-shaped membrane which are reflow technique and stamping technique. The comparison was made for both techniques using a Scanning Electron Microscope (SEM) and it seems the stamping technique has an advantage where the uniform thickness of the dome-shaped membrane can be achieved. The discussion on the temperature effect of a stamping technique shows that the suitable temperature to harden the PDMS is in temperature room where the bubbles can be eliminated under this temperature.

  • Characterization of Microfluidic-Based Acoustic Sensor for Immersion Application

    by Mohamad Faizal Abd Rahman, Mohd Norzaidi Mat Nawi, Asrulnizam Abd Manaf, Mohd Rizal Arshad

    This paper reported the characterization study on a new type of acoustic microsensor meant for immersion or underwater application. The new proposed device is based on microfluidic technology that is found to be able to overcome the fabrication issues associated with conventional capacitive micromachined ultrasonic transducer device. The design parameters have been explained in detail as well as their design justification. In this paper, two experiments have been setup to characterize the device performance. First, the pulse catch technique was used to investigate the device's response toward acoustic pulse or burst signal. The result shows that different number of burst cycles affects the capacitive response of the device. Providing the acoustic projector with suitable burst cycle parameter had yielded capacitive response with resolution of 1.16 pF, which is useful to be deployed in any suitable application such as for control or communication purposes. Second, the vibration effect had been studied between the ranges of 10-100 Hz of vibration. For rapid transition of the vibration frequency, the fall transition has a comparable error compared with the rise transition with an error ratio of 37:1. In terms of fluctuation behavior of the response, operating the device at static or constant frequency vibration does not have significant differences on the response, indicating its stability at single-frequency operation.


  • Microfluidic-based capacitive sensor for underwater acoustic application

    by M. F. A Rahman, M. N. M. Nawi, A. A Manaf, M. R. Arshad

    This work proposes a new concept of underwater acoustic capacitive sensor that operates based on the microfluidic mechanism. The main structures consist of a membrane, microchannel and coplanar detecting electrodes. The new sensor device is proposed to avoid the process complexity and facilities limitation during fabrication of the existing acoustic capacitive sensor meant for underwater application. The device is realised through a simple softlitography technique to produce the main detecting structure (membrane) and the detection region(microchannel). The final testing shows the ability of the device to detect an acoustic signal transmitted by an underwater projector at resonance frequency of 200 kHz. The linearity test of the coplanar electrodes configuration also yields the detection sensitivity of 0.021 pF/mm, operated at specific geometry. The result thus indicates that the proposed structure is able to become an alternative sensing device to the existing underwater acoustic sensor for low frequency underwater application.


  • An experimental study of the fluids mechanism and effects of liquid for capacitive pressure sensor

    by M N M Nawi, A A Manaf, M F A Rahman, M R Arshad, O Sidek

    This paper demonstrates the experiment for the capacitive pressure sensor for the fluid mechanism and effects of liquid to the sensor performance. The sensor using one side electrode was proposed with the implementation of electrical double layer capacitor. The sensor consisted of membrane and microchannel where it was fabricated using PDMS material. This sensor was able to measure the pressure below than 7 kPa. When the pressure was applied to the membrane, it gave deflection and the liquid inside the microchannel moved opposite the membrane. The liquid movement gives capacitance change to the sensor where it depends on the types of liquid used. The comparison was made between the experimental and analytical results for the liquid displacement inside the microchannel. In order to study the effect of liquid to the capacitance change, the methanol, ethanol and silicon oil were chosen. When related to the capacitance, the important factor for liquid is dielectric constant. It is proved that the methanol which has higher dielectric gives high performance compared to the ethanol and silicon oil. Given that the sensor sensitivity for the methanol and ethanol were 0.98 pF/kPa and 0.55 pF/kPa, respectively.