FLFengxiao Li

Fengxiao Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Fengxiao Li has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • Guowei Zhong

    Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education, and the Engineering Research Center of Industrial Computed Tomography Nondestructive Testing, Ministry of Education, Chongqing University, Chongqing, China

    2 shared publications
  • Haijun Yu

    Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing, China

    2 shared publications
  • Mingfu Zhao

    Intelligent Optical Fiber Sensing Technology Chongqing University Engineering Research Center, Chongqing University of Technology, Chongqing 400054, China

    2 shared publications
  • Rifeng Zhou

    Chongqing University

    2 shared publications
  • Biao Wei

    Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing, China

    1 shared publication
  • Bin Tang

    Intelligent optical fiber sensing technology Chongqing University Engineering Research Center, Chongqing University of Technology, Chongqing, China

    1 shared publication

Latest Publications

  • Research on the method for measuring the focal spot size of micro-focus X-ray sources using the JIMA resolution test card

    by Li Fengxiao, Wang Yixin, Xu Haodong, Zhong Guowei, Liu Chengfeng, Yang Run, Zhou Rifeng

    Background: Measuring an X-ray source's focal spot size is vital for Micro-CT resolution. Standard methods are often too complex or inaccurate. The popular JIMA resolution test card is simple to use but lacks a clear, quantitative formula to determine the actual focal spot size. Objective: This study aims to create a reliable quantitative link between JIMA resolution and focal spot size using simulations and experiments. Methods: We used Monte Carlo simulations and practical experiments to establish the relationship between JIMA resolution and focal spot size. Results: We found that the focal spot size is twice the line pair width on the JIMA card when the image contrast (MTF) is at 10%. This method is highly accurate, with a maximum measurement error of less than 8.7% compared to a high-precision technique. Conclusions: Our findings provide a simple, fast, and validated method for measuring focal spot size using the JIMA test card. This makes it a practical and reliable alternative to more complex procedures.


  • Improved Circular Edge Analysis Method for Measuring the Focus Size and Shape in High-Energy Electron Accelerator

    by Fengxiao Li, Guowei Zhong, Haijun Yu, Rifeng Zhou

    To achieve high spatial resolution of X-ray imaging, the focal spot size of high-energy non-destructive testing electron accelerators has been progressively reduced from 2 mm to below 1 mm, and in some cases, down to tens of micrometers. To measure these increasingly smaller focal spots, traditional methods such as the “Sandwich” test method and the slit translation scanning method, are no longer effective. This paper developed an improved circular edge analysis method (ICEAM) for measuring the size and shape of the focal spot of electron accelerators. The ICEAM employs the detector’s point spread function to correct the non-ideal circular aperture image caused by the X-ray scatter and the detector’s cross-talk. Then, edge spread functions of the corrected circular aperture image are used to construct a sinogram of the focal spot, which is subsequently used to reconstruct the intensity distribution image of the focal spot by using the filtered back-projection method. This approach enables precise measurement of both the shape and the size of the focal spot. Theoretical and experimental results demonstrate that ICEAM can not only conveniently and rapidly measure the shape and size of focal spots for conventional high-energy electron accelerators, with measurement errors within 5.8%, but also accurately measure the micrometer-scale focal spots for novel MeV energy electron accelerators (Rhodotron), with measurement errors within 16.2% of the theoretical value. The proposed ICEAM effectively tackles the challenges in measuring the shape and size of the microfocus for novel high-energy electron accelerators, and it is of significant importance for advancing the application of these electron accelerators in digital X-ray imaging and high-end equipment such as industrial CT.


  • Measuring Size and Stability of Focal Spot for Linear Accelerator in Industrial CT by Slit Translation Scanning Method

    by Fengxiao Li, Guowei Zhong, Haijun Yu, Kang An, Rifeng Zhou

    The size and stability of the X-ray beam focal spot in the electron linear accelerator are crucial factors affecting the spatial resolution of high-energy industrial computed tomography. The commonly used “Sandwich” test method for the X-ray beam focal spot size measurement is complex, vulnerable to human-related factors, and impossible for real-time measurement of stability. In this paper, we devise a slit translation scanning method to measure both size and stability of the X-ray beam focal spot for the electron linear accelerator. Firstly, this paper theoretically analyzed the impact of the effective slit width and sampling frequency on the measurement results. Secondly, a 9 MeV electron linear accelerator was used to measure the X-ray beam focal spot size. The measurement errors along x and y directions are smaller than 5.6% compared to the results measured by the IEC 62976-2017 standard method. Last, The stability of the X-ray beam focal spot was assessed using the slit translation scanning method with three different electron linear accelerators (9 MeV, 6 MeV, and 2 MeV). The results reveal random drift of the X-ray beam focal spot position, with a maximum drift up to 0.6 mm. The experiments demonstrate the simplicity and efficiency of the proposed slit translation scanning method which proves invaluable for the meticulous measurement of the size and stability of the X-ray beam focal spot for electron linear accelerator.


  • Open Access

    Research on Correction Method of Water Quality Ultraviolet-Visible Spectrum Data Based on Compressed Sensing

    by Fengxiao Li, Bin Tang, Mingfu Zhao, Xinyu Hu, Shenghui Shi, Mi Zhou

    The turbidity interference caused by suspended particles in water seriously affects the accuracy of ultraviolet-visible spectroscopy in detecting water quality chemical oxygen demand. Based on this, the application of ultraviolet-visible spectroscopy to detect water quality chemical oxygen demand usually requires physical and mathematical methods to correct the spectral baseline interference caused by turbidity. Because of the slow response speed and unstable compensation effect of traditional correction methods, this paper proposes to use a compressed sensing algorithm to perform baseline correction and achieve good results. In the experiment, we selected formazin turbidity solution and sodium oxalate standard solution and carried out the research on the algorithm of turbidity correction for detecting chemical oxygen demand of water quality by ultraviolet-visible spectroscopy. The experiment obtains the absorption spectra of different concentrations of formazine turbidity solutions and the same concentration of sodium oxalate with different turbidity standard solutions at 210∼845 nm and analyzes the nonlinear effect of absorbance on turbidity. This article uses standard solution experiments to explore the compressed sensing theory for turbidity correction, and through the correction of the absorption spectrum of the actual water sample, it verifies the feasibility of the compression theory for turbidity correction. The method effectively corrects the baseline shift or drift of the water quality ultraviolet-visible absorption spectrum caused by suspended particles, while retaining the absorption characteristics of the ultraviolet spectrum, and it can effectively improve the accuracy and accuracy of the ultraviolet-visible spectroscopy water quality chemical oxygen demand detection.


  • Open Access

    Fully Convolutional Pyramidal Networks for Semantic Segmentation

    by Fengxiao Li, Zourong Long, Peng He, Peng Feng, Xiaodong Guo, Xuezhi Ren, Biao Wei, Mingfu Zhao, Bin Tang

    Semantic segmentation networks focus on the scene parsing of an unrestricted open scene. The typical segmentation architectures are stacks consisting of convolutional layers, which are used to extract semantic features. The feature map dimension is sharply changed at sampling units for most of networks, which ensure effective propagation of the gradient in deep nets. In this article, we proposed a state-of-the-art network model named Fully Convolutional Pyramidal Networks (FC-PRNet), which employs pyramidal residual structure to change the feature map dimension at all convolutional layers. This design is an effective way of improving generalization ability and optimizing parameters, and FC-PRNet could achieve excellent capability of semantic extraction. We used urban scene benchmark CamVid and KITTI dataset to test our network, the experimental results show that FC-PRNet achieves better results without any pre-training or post-treatment module. Moreover, due to smart construction of pyramidal residual structures, FC-PRNet has less parameters than other existing networks trained on these datasets.