Arga Pratama Rahardian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Arga Pratama Rahardian has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Kusnanto Mukti Wibowo
Department of Medical Electronics Engineering Technology, Universitas Muhammadiyah Purwokerto, Purwokerto, Indonesia, Indonesia
2 shared publications - Supriyadi Supriyadi
Department of Master of Nursing, Faculty of Health Sciences, Universitas Muhammadiyah Purwokerto, Central Java, Indonesia, Indonesia
2 shared publications - Fani Susanto
Departement of Radiology Imaging Technology, Universitas Muhammadiyah Purwokerto, Banyumas, Indonesia, Indonesia
1 shared publication Fathur Rahman Nugraha
Departement of Radiology Imaging Technology, Universitas Muhammadiyah Purwokerto, Banyumas, Indonesia, Indonesia
1 shared publication- Hersnastiti Sedya Utami
Departement of Radiologic Imaging Technology, Universitas Muhammadiyah Purwokerto, Indonesia , Indonesia
1 shared publication Mahdelia Aqiilah Bilqiis
1 shared publication
Latest Publications
- Open Access
- 10 April 2026
- Published by Poltekkes Kemenkes Surabaya in Jurnal Teknokes
- Vol. 19 (2) , 084-092
Experimental Study on Thickness-Dependent X-ray Radiation Protection of a Flexible and Lightweight Silicone Rubber–PbO Composite Apron
The use of X-rays in medical imaging provides substantial diagnostic benefits but also poses risks associated with ionizing radiation exposure. Conventional lead-based protective aprons are effective but have major limitations, including excessive weight, rigidity, and potential toxicity. This study addresses a specific research gap by systematically evaluating the relationship between material thickness, radiation attenuation effectiveness, and the Half-Value Layer (HVL) of silicone rubber-based aprons filled with lead(II) oxide (PbO) at clinically relevant low-to-medium X-ray energies. An experimental method was employed by fabricating silicone–PbO composite apron prototypes with three thickness variations (2.5 mm, 3.0 mm, and 3.5 mm). Radiation attenuation tests were conducted at X-ray tube voltages of 60, 65, and 70 kV by measuring radiation intensity before and after transmission through the samples using a radiation detector, followed by calculating protection effectiveness and HVL values. The results demonstrate that apron thickness significantly influences radiation protection performance, with the highest attenuation of 85.11% achieved at a thickness of 3.5 mm. A moderate-to-strong positive correlation between thickness and protection effectiveness is observed at all voltage levels, with the highest coefficient of determination (R² = 0.916) at 65 kV. HVL values increase with thickness, indicating the need for thicker materials to achieve a 50% reduction in radiation intensity at higher attenuation levels. These findings highlight the novelty of quantitatively correlating thickness, attenuation effectiveness, and HVL within a single experimental framework and demonstrate that silicone rubber–PbO composite aprons have strong potential as a lightweight and flexible alternative to conventional lead aprons for clinical radiation protection at low-to-medium diagnostic X-ray energies.
- 10 April 2026
- Published by Poltekkes Kemenkes Surabaya in Jurnal Teknokes
- Vol. 19 (2) , 084-092
Open AccessExperimental Study on Thickness-Dependent X-ray Radiation Protection of a Flexible and Lightweight Silicone Rubber–PbO Composite Apron
The use of X-rays in medical imaging provides substantial diagnostic benefits but also poses risks associated with ionizing radiation exposure. Conventional lead-based protective aprons are effective but have major limitations, including excessive weight, rigidity, and potential toxicity. This study addresses a specific research gap by systematically evaluating the relationship between material thickness, radiation attenuation effectiveness, and the Half-Value Layer (HVL) of silicone rubber-based aprons filled with lead(II) oxide (PbO) at clinically relevant low-to-medium X-ray energies. An experimental method was employed by fabricating silicone–PbO composite apron prototypes with three thickness variations (2.5 mm, 3.0 mm, and 3.5 mm). Radiation attenuation tests were conducted at X-ray tube voltages of 60, 65, and 70 kV by measuring radiation intensity before and after transmission through the samples using a radiation detector, followed by calculating protection effectiveness and HVL values. The results demonstrate that apron thickness significantly influences radiation protection performance, with the highest attenuation of 85.11% achieved at a thickness of 3.5 mm. A moderate-to-strong positive correlation between thickness and protection effectiveness is observed at all voltage levels, with the highest coefficient of determination (R² = 0.916) at 65 kV. HVL values increase with thickness, indicating the need for thicker materials to achieve a 50% reduction in radiation intensity at higher attenuation levels. These findings highlight the novelty of quantitatively correlating thickness, attenuation effectiveness, and HVL within a single experimental framework and demonstrate that silicone rubber–PbO composite aprons have strong potential as a lightweight and flexible alternative to conventional lead aprons for clinical radiation protection at low-to-medium diagnostic X-ray energies.
- Open Access
- 23 December 2025
- Published by Center for Journal Management and Publication, Lambung Mangkurat University in Jurnal Fisika Flux: Jurnal Ilmiah Fisika FMIPA Universitas Lambung Mangkurat
- Vol. 23 (1) , 78
Analisis Korelasi Berat Badan dengan Size Spesific Dose Estimate dan Dosis Efektif pada CT Scan Abdomen
- 23 December 2025
- Published by Center for Journal Management and Publication, Lambung Mangkurat University in Jurnal Fisika Flux: Jurnal Ilmiah Fisika FMIPA Universitas Lambung Mangkurat
- Vol. 23 (1) , 78
Open AccessAnalisis Korelasi Berat Badan dengan Size Spesific Dose Estimate dan Dosis Efektif pada CT Scan Abdomen