Anatoly S. Kalyakin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Anatoly S. Kalyakin has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Anatolii K. Demin
Laboratory of Electrochemical Devices Based on Solid Oxide Proton Electrolytes, Institute of High Temperature Electrochemistry, Yekaterinburg, Russia
8 shared publications A. Volkov
5 shared publications- Alexander Volkov
Institute of High-Temperature ElectrochemistryUB RAS, Russian Federation
5 shared publications - Dmitry A. Medvedev
Ural Federal University, Ekaterinburg
5 shared publications - Panagiotis Tsiakaras
Laboratory of Alternative Energy Conversion Systems, Department of Mechanical Engineering, School of Engineering, University of Thessaly, Pedion Areos, 38834 Volos, Greece
5 shared publications - Elena Gorbova
Russian Academy of Sciences
4 shared publications
Latest Publications
- Open Access
- 17 June 2026
- Published by Ural Federal University in Electrochemical Materials and Technologies
- Vol. 5 (2) , 20254071
YSZ-based underfiring sensor for simultaneous measurement of residual oxygen and unburnt species in flue gases
Flue gas analysis is essential for optimizing combustion efficiency, reducing fuel costs, and ensuring safety by detecting dangerous emissions like carbon monoxide. An amperometric YSZ-based sensor for simultaneous measurement of the concentrations of residual oxygen and unburnt species (CO, H2) in flue gases has been developed. The sensor has a simple structure and is easy to fabricate, providing a cost-effective solution. It demonstrates high sensitivity, good reproducibility and acceptable response time. The use of the sensor for the in-situ real-time analysis of flue gas will facilitate the optimization of air-fuel ratios, thereby preventing fuel wastage and hazardous emissions.
- 17 June 2026
- Published by Ural Federal University in Electrochemical Materials and Technologies
- Vol. 5 (2) , 20254071
Open AccessYSZ-based underfiring sensor for simultaneous measurement of residual oxygen and unburnt species in flue gases
Flue gas analysis is essential for optimizing combustion efficiency, reducing fuel costs, and ensuring safety by detecting dangerous emissions like carbon monoxide. An amperometric YSZ-based sensor for simultaneous measurement of the concentrations of residual oxygen and unburnt species (CO, H2) in flue gases has been developed. The sensor has a simple structure and is easy to fabricate, providing a cost-effective solution. It demonstrates high sensitivity, good reproducibility and acceptable response time. The use of the sensor for the in-situ real-time analysis of flue gas will facilitate the optimization of air-fuel ratios, thereby preventing fuel wastage and hazardous emissions.
- Open Access
- 18 January 2026
- Published by Ural Federal University in Chimica Techno Acta
- Vol. 13 (1) , 9277
Electrochemical sensor for determining CO and H 2 O content during CO conversion for hydrogen production
The paper presents the results of the study on an electrochemical solid electrolyte sensor with a diffusion barrier for simultaneous measurements of carbon (II) oxide and moisture concentrations in the initial gaseous mixture for the carbon oxide conversion into hydrogen. The sensor is composed of two electrochemical cells made of commercial stabilized zirconium dioxide of the 90 mol.% ZrO2 +10 mol.% Y2O3 composition. One electrochemical cell performs carbon oxide content measurements in the initial gas mixture, and another cell determines the humidity of the same gas mixture. Both electrochemical cells operate in an amperometric mode. We obtained dependences of the limiting sensor current both on the carbon oxide and on the moisture concentrations in the gas mixture, as well as the temperature dependences of the limiting currents within the range of 650–750 оС. The sensor dynamic characteristics for the measurement of carbon oxide concentration and moisture at the temperature of 700 оС were obtained. The sensor possesses a satisfactory determination rate and high reproducibility at the operating temperature of 700 oС.
- 18 January 2026
- Published by Ural Federal University in Chimica Techno Acta
- Vol. 13 (1) , 9277
Open AccessElectrochemical sensor for determining CO and H 2 O content during CO conversion for hydrogen production
The paper presents the results of the study on an electrochemical solid electrolyte sensor with a diffusion barrier for simultaneous measurements of carbon (II) oxide and moisture concentrations in the initial gaseous mixture for the carbon oxide conversion into hydrogen. The sensor is composed of two electrochemical cells made of commercial stabilized zirconium dioxide of the 90 mol.% ZrO2 +10 mol.% Y2O3 composition. One electrochemical cell performs carbon oxide content measurements in the initial gas mixture, and another cell determines the humidity of the same gas mixture. Both electrochemical cells operate in an amperometric mode. We obtained dependences of the limiting sensor current both on the carbon oxide and on the moisture concentrations in the gas mixture, as well as the temperature dependences of the limiting currents within the range of 650–750 оС. The sensor dynamic characteristics for the measurement of carbon oxide concentration and moisture at the temperature of 700 оС were obtained. The sensor possesses a satisfactory determination rate and high reproducibility at the operating temperature of 700 oС.
- Open Access
- 12 March 2024
- Published by Ural Federal University in Electrochemical Materials and Technologies
- Vol. 3 (1) , 20243027
Stability and reproducibility of the amperometric sensors for oxygen concentration analysis in the nitrogen gas mixtures
The paper presents experimentally obtained results on the long-term stability tests of the solid electrolyte amperometric sensor output signal during the operation in the O2 + N2 gas mixtures. These data prove the stability and reproducibility of the output signal when measuring the oxygen concentration in air for 8000 hours. The output signal variation during the tests did not exceed ± 2 %. We performed four heating / cooling cycles of different durations, which did not influence either sensor integrity or operation characteristics. The structure of the solid electrolyte sensor and the solid electrolyte/electrode interfacial layer remained unchanged during the tests. Dynamic characteristics of the sensor, including the response time, were stable.
- 12 March 2024
- Published by Ural Federal University in Electrochemical Materials and Technologies
- Vol. 3 (1) , 20243027
Open AccessStability and reproducibility of the amperometric sensors for oxygen concentration analysis in the nitrogen gas mixtures
The paper presents experimentally obtained results on the long-term stability tests of the solid electrolyte amperometric sensor output signal during the operation in the O2 + N2 gas mixtures. These data prove the stability and reproducibility of the output signal when measuring the oxygen concentration in air for 8000 hours. The output signal variation during the tests did not exceed ± 2 %. We performed four heating / cooling cycles of different durations, which did not influence either sensor integrity or operation characteristics. The structure of the solid electrolyte sensor and the solid electrolyte/electrode interfacial layer remained unchanged during the tests. Dynamic characteristics of the sensor, including the response time, were stable.
- Open Access
- 12 January 2024
- Published by Ural Federal University in Electrochemical Materials and Technologies
- Vol. 3 (1) , 20243026
Stability and reproducibility of solid electrolyte amperometry sensors at the analysis of hydrogen in nitrogen-containing gas mixtures
This paper illustrates the results of long-term tests on the stability of the output signal of the solid electrolyte amperometry sensor when measuring the hydrogen concentration in the H2 + N2 gaseous mixture. The obtained experimental data verify the stability and reproducibility of the sensor output signal for hydrogen concentration measurements in the nitrogen-containing gaseous mixture during 8000 h of operation. The output signal drift, i.e., the limiting current value, was insignificant, less than ± 5 %. The sensor operation was performed at 3 temperature shifts with different time intervals; these changes did not have any impact either on the sensor integrity or on its operation. The structure of the solid electrolyte sensor, intermediate solid electrolyte / electrode layer and electrodes did not undergo any significant changes during operation. The dynamic characteristics of the sensor, the response time in particular, remained stable during the operation.
- 12 January 2024
- Published by Ural Federal University in Electrochemical Materials and Technologies
- Vol. 3 (1) , 20243026
Open AccessStability and reproducibility of solid electrolyte amperometry sensors at the analysis of hydrogen in nitrogen-containing gas mixtures
This paper illustrates the results of long-term tests on the stability of the output signal of the solid electrolyte amperometry sensor when measuring the hydrogen concentration in the H2 + N2 gaseous mixture. The obtained experimental data verify the stability and reproducibility of the sensor output signal for hydrogen concentration measurements in the nitrogen-containing gaseous mixture during 8000 h of operation. The output signal drift, i.e., the limiting current value, was insignificant, less than ± 5 %. The sensor operation was performed at 3 temperature shifts with different time intervals; these changes did not have any impact either on the sensor integrity or on its operation. The structure of the solid electrolyte sensor, intermediate solid electrolyte / electrode layer and electrodes did not undergo any significant changes during operation. The dynamic characteristics of the sensor, the response time in particular, remained stable during the operation.
- Open Access
- 3 October 2023
- Published by Ural Federal University in Electrochemical Materials and Technologies
- Vol. 2 (3) , 20232019
Sensor for operational control of oxygen and combustible gases concentration in waste gases of thermal units
A new sensor has been developed for continuous monitoring of oxygen and combustible gases content in the waste gases of thermal units. The target application of the sensor is its installation in shunt pipes of thermal units, directly into the waste gas flow. The sensor is characterized by one reference gas electrode and three measuring electrodes applied on the surface of a solid electrolyte tube made of a zirconia electrolyte (e.g., 8YSZ). The reference gas electrode and one of the measuring electrodes were made of silver, the second measuring electrode was made of platinum, the third measuring electrode was made of a mixture of zinc oxide (95 wt %) and lanthanum-strontium manganite (5 wt %). The oxygen content in the gas mixture was determined by the well-known potentiometric method in accordance with the Nernst equation, i.e. an Ag|8YSZ|Ag electrochemical cell was used. To determine the products of incomplete combustion of fuel, the method of mixed potential between Pt- and Zn-based electrodes was used; the obtained potential value was determined by the difference in the oxidation rate of carbon monoxide as the main component of unburned fuels, on different materials of measuring electrodes. The experimental results of the sensor for the determination of carbon monoxide, hydrogen, and methane in a gas mixture are presented.
- 3 October 2023
- Published by Ural Federal University in Electrochemical Materials and Technologies
- Vol. 2 (3) , 20232019
Open AccessSensor for operational control of oxygen and combustible gases concentration in waste gases of thermal units
A new sensor has been developed for continuous monitoring of oxygen and combustible gases content in the waste gases of thermal units. The target application of the sensor is its installation in shunt pipes of thermal units, directly into the waste gas flow. The sensor is characterized by one reference gas electrode and three measuring electrodes applied on the surface of a solid electrolyte tube made of a zirconia electrolyte (e.g., 8YSZ). The reference gas electrode and one of the measuring electrodes were made of silver, the second measuring electrode was made of platinum, the third measuring electrode was made of a mixture of zinc oxide (95 wt %) and lanthanum-strontium manganite (5 wt %). The oxygen content in the gas mixture was determined by the well-known potentiometric method in accordance with the Nernst equation, i.e. an Ag|8YSZ|Ag electrochemical cell was used. To determine the products of incomplete combustion of fuel, the method of mixed potential between Pt- and Zn-based electrodes was used; the obtained potential value was determined by the difference in the oxidation rate of carbon monoxide as the main component of unburned fuels, on different materials of measuring electrodes. The experimental results of the sensor for the determination of carbon monoxide, hydrogen, and methane in a gas mixture are presented.
- Open Access
- 14 February 2023
- Published by Ural Federal University in Chimica Techno Acta
- Vol. 10 (1) , 202310109
Electrochemical detection of simple alkanes by utilizing a solid-state zirconia-based gas sensor
Solid-state gas sensors composed of complex oxide electrolytes offer great potential for analyzing various atmospheres at high temperatures. While relatively simple gas mixtures (H2O+N2, O2+N2) have been successfully studied by means of ZrO2-based sensors, the precise detection of more complex compounds represents a challenging task. In this work, we present our findings regarding the analysis of lower alkanes (CH4, C2H6, and C3H8) mixed with nitrogen as an inert gas, utilizing an amperometric ZrO2-based sensor. This sensor, serving as an electrochemical cell with a diffusion barrier, was tested at 500–600 °C to measure the limiting current, which depends on the gas composition and can be further used as a basis for calibration curves. In addition, the diffusion coefficients of the specified gas mixtures were successfully found and compared with references, confirming the applicability of the fabricated sensor for studying diffusion processes in wide concentration and temperature ranges.
- 14 February 2023
- Published by Ural Federal University in Chimica Techno Acta
- Vol. 10 (1) , 202310109
Open AccessElectrochemical detection of simple alkanes by utilizing a solid-state zirconia-based gas sensor
Solid-state gas sensors composed of complex oxide electrolytes offer great potential for analyzing various atmospheres at high temperatures. While relatively simple gas mixtures (H2O+N2, O2+N2) have been successfully studied by means of ZrO2-based sensors, the precise detection of more complex compounds represents a challenging task. In this work, we present our findings regarding the analysis of lower alkanes (CH4, C2H6, and C3H8) mixed with nitrogen as an inert gas, utilizing an amperometric ZrO2-based sensor. This sensor, serving as an electrochemical cell with a diffusion barrier, was tested at 500–600 °C to measure the limiting current, which depends on the gas composition and can be further used as a basis for calibration curves. In addition, the diffusion coefficients of the specified gas mixtures were successfully found and compared with references, confirming the applicability of the fabricated sensor for studying diffusion processes in wide concentration and temperature ranges.
- 1 October 2018
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 23 (1) , 73-79
A high-temperature electrochemical sensor based on CaZr0.95Sc0.05O3–δ for humidity analysis in oxidation atmospheres
- 1 October 2018
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 23 (1) , 73-79
A high-temperature electrochemical sensor based on CaZr0.95Sc0.05O3–δ for humidity analysis in oxidation atmospheres
- 1 January 2018
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 808, 133-136
An electrochemical method for the determination of concentration and diffusion coefficient of ammonia‑nitrogen gas mixtures
- 1 January 2018
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 808, 133-136
An electrochemical method for the determination of concentration and diffusion coefficient of ammonia‑nitrogen gas mixtures
- 1 March 2017
- Published by Elsevier in Electrochemistry Communications
- Vol. 76, 55-58
Electrochemical moisture analysis by combining oxygen- and proton-conducting ceramic electrolytes
- 1 March 2017
- Published by Elsevier in Electrochemistry Communications
- Vol. 76, 55-58
Electrochemical moisture analysis by combining oxygen- and proton-conducting ceramic electrolytes
- 1 August 2016
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 231, 175-182
Combined amperometric and potentiometric hydrogen sensors based on BaCe0.7Zr0.1Y0.2O3−δ proton-conducting ceramic
- 1 August 2016
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 231, 175-182
Combined amperometric and potentiometric hydrogen sensors based on BaCe0.7Zr0.1Y0.2O3−δ proton-conducting ceramic