OSOleksandr Leonidovich Shubenko

Oleksandr Leonidovich Shubenko

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Oleksandr Leonidovich Shubenko has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Determination of the impact of optimal average operating modes of the PT-20-2.9/1.0 turbine on CHP plant performance indicators during hot water supply

    by Andrii Kostikov, Oleksandr Shubenko, Victoria Tarasova, Mykola Babak, Andrii Mazur

    The object of the study is the energy processes in a heat-generating steam turbine operating with a deteriorated condenser vacuum for hot water supply (HWS). The problem of increasing the efficiency of a heating plant was solved, in which in the warm season HWS is provided by one turbine and a peak water boiler (PWB). Results obtained: a method for determining the optimal average operating modes of the object of the study was developed, tested on the PT-20-2.9/1.0 (PT-20) turbine (Ukraine) with a capacity of 20 MW of Kharkiv CHP-3. The proposed method is based on mathematical modeling of the thermal scheme of the turbine installation and optimization of its operating parameters. The maximum electricity generation was chosen as the optimality criterion while observing the design and operating limitations of the turbine. Optimization parameters: steam flow rate into the turbine head, network water temperature after its feed, and steam pressure in the condenser. The peculiarity of the obtained calculation results is connected with the absence of regenerative heaters in PT-20 and with the necessity to solve three optimization problems by the number of characteristic periods of operation of the heating plant. When operating on HWS, the temperature and average flow rate of the return network water change significantly during the day: night +65°С, ~3000 t/h, morning and evening peak times +51°С, ~4500 t/h, day +51°С, ~3600 t/h. The best performance indicators of the Kharkiv CHP-3 were obtained in the peak mode with three-stage (condenser, network heater and PWB) heating of network water, in other modes – two-stage (PWB turned off). The worst – in the night mode. The presented results on the optimization of the PT-20 operating modes on HWS are used at the Kharkiv CHP-3. After further development, the developed method can become the basis for determining the optimal seasonal operating modes of a heating plant with several steam turbines

  • Open Access

    APPROXIMATION EQUATIONS OF STEAM STATE IN THE LOW-PRESSURE REGION FOR ANALYSIS OF WORK THE LAST STAGES STEAM TURBINE

    by Oleksandr Shubenko, Volodymyr Goloshchapov, Olga Kotulska, Tetiana Paramonova, Roman Kotulskiy

    The operating conditions of the low-pressure cylinder (LPC) of steam turbines used at thermal and nuclear power plants were analyzed. The LPC stages operate both in the region of superheated steam and in the wet steam region, where phase transition phenomena significantly influence on efficiency and blade erosion. In practical operation, the thermodynamic state of steam is usually determined by using steam tables or complex approximation functions based on tabulated data, which are not always convenient for real-time engineering calculations. Based on the classical ideal gas equation of state and using tabulated thermodynamic properties of water and steam in accordance with IAPWS formulations, approximation equations of state are developed for dry saturated, superheated, and wet steam in the low-pressure range from 3 to 100 kPa. The proposed approach introduces a variable (local) gas constant that accounts the influence of pressure, temperature, and steam quality. Regression equations are obtained for the specific volume of steam as a function of pressure, temperature, and dryness degree. The results demonstrate that, within defined regions of superheat, the thermodynamic behavior of steam approaches to an ideal gas with a practically constant gas constant. For wet steam, simple relations based on steam quality are proposed. The derived approximation equations provide sufficient accuracy for engineering applications and can be effectively used for thermal and energy analysis of LP turbine stages operating under variable load conditions.

  • Open Access

    ЗНИЖЕННЯ НАПРУГИ НА ЗУБЦЯХ ХВОСТОВОГО З’ЄДНАННЯ ЛОПАТКИ ПАРОВОЇ ТУРБІНИ ЧЕРЕЗ ЗМІНУ ФОРМИ ОПОРНИХ ПЛОЩИН

    by O. Shubenko, М. Бабак, О. Бояршинов, O. Boiarshynov

    Вступ. Хвостові з’єднання ялинкового типу довгих лопаток парових турбін, які є багатоопорними конструкціями, працюють у складних напружених умовах, що характеризуються нерівномірним розподілом загальних і місцевих напружень. Вирішення проблеми покращення геометрії хвостового з’єднання довгих робочих лопаток дозволяє збільшити запас міцності та термін служби цього відповідального елемента.Проблематика. Наразі рівномірність розподілу напружень по опорних зубцях хвостового з’єднанняпорушується вимушеним виконанням технологічного зазору у 0,02 мм, що ліквідує контакт по частині зубців, утворюючи нерівномірний розподіл навантаження в цьому вузлі.Мета. Розробка оригінальної конструкції, де за рахунок спеціальної форми опорної поверхні зубців, щозабезпечує компенсацію технологічних зазорів, можна підвищити рівномірність розподілу напруг у багатоопорних хвостових з’єднаннях ялинкового типу.Матеріали й методи. Використано методи моделювання енергетичного обладнання з використанням методів кінцевих елементів. Розглянутий алгоритм розрахунку став базою для методики конструювання високонапружених багатоопорних кріплень у потужних парових турбінах.Результати. Розроблено оригінальну конструкцію, де за рахунок спеціальної форми опорної поверхні зубців, що забезпечує компенсацію технологічних зазорів, збільшується рівномірність розподілу напруг убагатоопорних хвостових з’єднаннях робочих лопаток потужних парових турбін. Значно зменшено навантаження на верхніх зубцях, яке перенесено на нижні зубці, що раніше не були достатньо задіяні.Висновки. Запропоновано оригінальний підхід до вирішення задачі зменшення напруги у хвостовихз’єднаннях ялинкового типу потужних парових турбін за рахунок використання спеціальної (циліндричної) форми опорних поверхонь зубців, що забезпечує компенсацію технологічних зазорів. Така конструкція сприяє більш рівномірному розподілу навантажень по зубцях, збільшуючи ресурс та характеристики міцностні всієї конструкції.

  • Open Access

    ENERGY CHARACTERISTICS OF FLOW STRUCTURAL ELEMENTS AT LOW-COST OPERATING MODES OF TURBINE STAGES WITH LONG BLADES

    by O. L. Shubenko, V. M. Goloschapov, O. V. Kotulska, T. M. Paramonova, P. O. Kotulskiy

    Low-cost operating modes of turbine stages with long blades span the range from idle operation to zero mass flow of the working medium, where a purely ventilatory regime is established. At idle, the flow remains close to jet-like behavior. A reduction in steam flow within the inter-blade gap generates a rotating vortex due to increased pressure in the central part of the blade channels. The working medium is eject into the inter-blade gap with high circumferential velocity, and the trailing edges of the rotor blades near the hub redirect the flow radially into the inter-stage gap or the outlet pipe, forming a hub-region flow separation. This study aims to analyze the energy characteristics of the flow structure in turbine stages with long blades based on experimental data, evaluating the energy supplied to the rotor and the associated thermal losses across the operating range . In low-flow regimes, the energy input from external sources to the rotor blades is determined using Euler’s equation, accounting for flow division into streamlets and integrating the energy supplied to each. This approach enables a one-dimensional representation of the three-dimensional viscous flow. The most significant aspect of low-flow regimes is the energy analysis of each flow component to assess energy losses driving the rotor and thermal losses affecting the thermal state of stage elements, particularly the rotor blades. Based on comprehensive analysis of existing experimental data from powerful turbine stages, a methodology has been developed incorporating regression equations for energy characteristics of each flow structure, considering blade length and flow capacity. The influence of blade length is quantified by the relative throughput of the stage, defined by the ratio of end-face areas and the sine relationship of flow exit angles from the guide vanes and rotor blades. Irreversible (thermal) losses of mechanical energy determine the heating level of the working medium at the measurement point. These losses allow for the estimation of medium heating within each flow structure, given known inlet or outlet temperatures.

  • Open Access

    ENERGY SAVINGS WHEN INTEGRATING A STEAM-HEATED LITHIUM BROMIDE ABSORPTION HEAT PUMP INTO A STEAM TURBINE THERMAL SCHEME

    by A.о. Kostikov, O.L. Shubenko, V.O. Tarasova, N.YU. Babak, A.O. Mazur

    To utilize the heat emitted into the atmosphere by a steam turbine generator, a sufficiently effective means of energy saving is the integration into the turbine thermal scheme of an absorption lithium bromide heat pump (AHP) with steam heating. The purpose of the study is to determine the efficiency of energy saving with an integrated AHP with a capacity of 17.3 MW, which is heated by steam from the turbine production selection with different pressures, using the example of a mathematical model of the PT-60/70-130/13 thermal scheme. The power of AHP was determined during previous studies. The state of the problem of recycling the circulating water of the steam turbine condenser cooling by using heat pumps is analyzed. The influence of the steam pressure in the production selection on the performance of the integrated turbine unit in the heating season is studied. The pressure in the production selection of the steam turbine varied from 1.66 MPa to 0.693 MPa. As an energy saving measure, it is proposed to install a steam screw machine with a nominal power of 1 MW to expand the steam to the parameters required for heating the steam turbine. The calculations were performed taking into account the average monthly outdoor temperatures in Ukraine in the heating season. The thermal load of the PT-60/70-130/13 with the integrated steam turbine was provided by setting fixed steam consumption to the consumer of 15 t/h, and network water for heat supply of 1600 t/h. Depending on the steam pressure from the production selection, the power of the recycling steam screw machine varied in the range of 0.651–1 MW. Integration of AHP 17.3 MW into PT-60/70-130/13, depending on the selected steam pressure in the production selection during operation in the heating period, leads to an increase in efficiency by 3.4–3.7 %, tangible savings in conventional fuel (5.8–6.4 %), improves the environment, saves 105–107 thousand tons of technical water, reduces harmful emissions into the atmosphere: greenhouse gases by 5.9–6.4 %, and 65.9–67.1 GW of heat from circulating water in the cooling tower. The consequence of this integration, which can be considered negative, is a decrease in total “useful” electricity generation (by 2.3–3.2 %). According to preliminary estimates, the integration of AHP 17.3 MW into PT-60/70-130/13 is a promising energy saving technology for implementation. At fuel prices (natural gas) of 300 USD/t с.f., and electricity of 150 USD/MW×h it has a simple payback period of ~ 2.9 years (investments are estimated at 3150 thousand USD), if AHP 17.3 MW is heated by steam, the pressure of which is in the range of 1.0–1.2 MPa. It is in this range of pressure of steam that heats the heat pump that we recommend operation. Bibl. 27, Fig. 2, Tab. 4.


  • Open Access

    APPROXIMATE RELATIONSHIPS FOR DETERMINING THE ENTHALPIES OF WATER AND STEAM IN THE CALCULATIONS OF HEAT EXCHANGER DEVICES OF STEAM TURBINE INSTALLATIONS (PART II – DETERMINATION OF THE ENTHALPY OF WATER STEAM)

    by Олександр Леонідович Шубенко, Volodymyr Goloshchapov, Ольга Валеріївна Котульська, Тетяна Миколаївна Парамонова, Володимир Миколайович Голощапов

    The conducted studies are the II part of a complex work on creating a methodological approach for determining the enthalpy of water and water vapor in the calculations of heat exchange equipment for operational control of the operating modes of large power steam turbines, when the use of tables of thermodynamic properties of working media in the "manual" mode is not successful. The current part II of the work, in contrast to part I, where the determination of the enthalpy of water is considered, is devoted to the determination of the enthalpy of water vapor. A methodological approach of obtaining approximating equations for determining enthalpy from the values of changing steam parameters is proposed, similar to what was done for water in рart I. In order to ensure the necessary approximation accuracy, the zone of the studied characteristics is divided by pressure into two regions - the vacuum region (1 kPa ≤ Р ≤ 100 kPa) and the overpressure region (0.1 MPa ≤ Р≤ 6 MPa), which in turn is divided into 3 regions (0.1 MPa ≤ Р ≤ 1 MPa, 1 MPa ≤ Р ≤ 3 MPa, 3 MPa ≤ Р ≤ 6 MPa). Since the effect of temperature in the area of the studied parameters is more significant than pressure, there was a need to introduce a significantly larger number of intervals in terms of temperature: 4 – in the vacuum area and15 – in the overpressure area. As a result, a system of approximating equations is proposed, which is characterized by sufficient accuracy in determining the enthalpy in the entire studied range of changes in the superheated steam parameters – pressure and temperature. To demonstrate the obtained results, an example of the application of the proposed methodology to the calculation of a specific heat exchange device is made in the work. The determination of the superheated steam consumption in the conditions of the thermal scheme of the T-250/300-240 heating turbine operated at the CHP, in relation to the PVТ-8 high-pressure heater for one of the operating modes, is given. As a result, it was found that the discrepancy between the value of the consumption of heating steam, determined according to the table values, and the consumption determined according to the obtained approximating dependencies, is 2.2 %, which is quite acceptable for practical needs in the operation of steam turbine plants.

  • Optimal Thermal Output of an Absorption Heat Pump with Steam Heating Integrated in a PT-60/70-130/13 Steam Turbine

    by Anatolii Pidhornyi Institute of Power Machines and Systems of NAS of Ukraine, Oleksandr L. Shubenko, Viktoriia O. Tarasova, Mykola Yu. Babak, Oleksii Yu. Boiarshynov

    The problem of determining the optimal thermal power of the absorption bromide-lithium heat pump (AHP) with steam heating, integrated into the thermal scheme of the PT-60/70-130/13 steam turbine when operating in the mode with a slight opening of the rotary regulating diaphragm, was formulated and solved. The turbine plant released steam to consumers and provided heat according to the schedule of 150 / 70 ºС. The characteristics of AHP were modeled using approximate dependencies based on the characteristics of thermotransformer manufacturers. AHP was heated by steam from the production selection of the turbine after the steam screw machine installed for energy saving. The general optimization problem with the objective function of changing the monthly fuel consumption after the integration of AHP, based on the average monthly outdoor air temperature in the heating season in Ukraine, was divided into 6 auxiliary optimization problems. The control parameters of these problems were: thermal capacity of the AHP, steam pressure in the turbine condenser and at the inlet to the heat pump, steam pressure in the turbine headю These problems were solved by the coordinate descent method. Modes with steam consumption in the production selection of the turbine for the consumers were studied: 15, 30 and 45 t/h (with parameters: 1.296 MPa, 280 ºС) and mains water: 1600, 1650 and 1700 m3/h. Their feature is the provision of "useful" generation in volumes corresponding to the work of PT-60/70-130/13 without AHP with a closed rotary diaphragm. For all considered options of the turbine load, the optimal power of the integrated AHP is defined as 20 MW. During the heating period PT-60/70-130/13 with AHP 20 MW when operating in a mode close to the thermal load with the lower of the studied consumptions of production steam and mains water leads to savings of: fuel by ~3.5%, softened water by 8.5%, technical of water by 79.9%, as well as to a noticeable ecological effect due to the reduction of harmful emissions into the atmosphere. The preliminary payback period of AHP is close to 3 years. It is noted that the option of the integrated turbine with a partially open regulating diaphragm at the accepted prices for fuel and electricity loses in terms of economic indicators to the option with a closed diaphragm.


  • Open Access

    APPROXIMATE RELATIONSHIPS FOR DETERMINING THE ENTHALPIES OF WATER AND STEAM IN THE CALCULATIONS OF HEAT EXCHANGER DEVICES OF STEAM TURBINE INSTALLATIONS (PART I – DETERMINATION OF THE ENTHALPY OF WATER)

    by Олександр Леонідович Шубенко, Volodymyr Goloshchapov, Ольга Валеріївна Котульська, Тетяна Миколаївна Парамонова, Володимир Миколайович Голощапов

    The work is devoted to the creation of a methodological approach for determining the thermodynamic properties of water and water vapor in the calculation of heat exchange processes for those cases when it is necessary to quickly control the operating modes of steam turbines of large power of thermal and nuclear power plants, but the use of existing tables of properties of working environments in the "manual" mode is not always suppose. In the presented part of the work the determination of the enthalpy of water is considered. Based on the analysis of the operating modes of heat exchangedevices of power units thermal and nuclear power plants of different capacities, the ranges of temperature and pressure changes of the working media during their calculations were determined. They are for water: at a pressure of 1 kPa–30 MPa, at a temperature of 1–300 °С, and for steam, respectively: 1 kPa–6 MPa, 7–450 °С. The analysis of tabular values of the working medium (water) showed that in order to present the enthalpy of water in an analytical form based on approximation equations with the required accuracy, it is advisable to consider their construction in two areas of change: in the area of vacuum (Р < 0.1 MPa) and in the area of excess pressure (0.1–30 MPa), which in turn are divided into 4 ranges. When thepressure changes, this is associated with an additional effect on the temperature enthalpy value, which complicates the choice of approximate dependencies for obtaining enthalpy from the parameters of the working environment while ensuring an acceptable ratio of calculated and tabular values for solving problems. By the authors a system of regression equations was obtained, allowing to calculate the enthalpy of water in a given range of pressures and temperatures with high accuracy. To determine the area in which the measured value is located, the authors proposed the use of Antoine's formula, in which the relationship between the pressure and temperature of the medium at the boundary line of the phase transition is established. To increase its accuracy, approximation equations for temperature corrections at different pressures are proposed, which ensure that the temperature deviates from the tabulated values of thermophysical properties there are no more than ±0.04 °С.


  • Open Access

    Increase of the Efficiency of Heat Supply Units of the CHP Plants Due to the Choice of Rational Heat Release Modes

    by Oleksandr L. Shubenko, Anatolii Pidhornyi Institute of Mechanical Engineering Problems of NAS of Ukraine, Svitlana V. Alyokhina, Volodymyr M. Holoshchapov, Olha A. Babenko, Olha V. Kotulska, University of Applied Sciences Technikum Wien

  • Open Access

    REFINED PHYSICAL MODEL OF STEAM FLOW IN THE LOW-PRESSURE PART OF A HIGH-POWER TURBINE IN LOW-FLOW RATE MODES

    by O. L Shubenko, V. M. Goloschapov, O. V. Kotulska, T. M. Paramonova

    Analytical methods for calculating the performance of the turbine are operational as long as the “layered” character of the steam flow is preserved in the flow part. However, as shown by experimental studies, the character of the flow changes significantly in low-flow rate modes. In these cases, existing methods of three-dimensional calculations require reliable formation of boundary conditions. The purpose of this study is to analyze the characteristics of low-pressure cylinder (LPC) stages operating in high-power stationary steam turbines, and to form physical models of the flow of the working medium (steam) in such stages at low-flow rate modes, taking into account their location in the flow part. It is advisable to imagine the physical model of the movement of steam in the turbine, starting from the last stage of the LPC and the outlet nozzle, in which separation of flow from the hub the develops. Its formation occurs when the relative volumetric flow rate decreases, starting with = 0.8, depending on the angle b2к at the root of the working blades. A decrease in the operating mode of the LPC turbine stages is also accompanied by a decrease the flow speed in the peripheral zone and a negative angle of attack at the flow entry into the channels of the impeller. On the concave surface of the profile part of the blade, a separation area is formed, which rotates in the rim clearance in the circumferential direction. Reverse flow from the inlet part of the channels of the impeller into the rim clearance occur when the static pressure in it exceeds the full pressure of the flow coming out of the channels of the guide apparatus. Turbulization of the flow of the rotating vortex leads to large irreversible losses of the mechanical energy of the moving flow, which are converted into heat, heating the mass of the working medium of the vortex and the main flow averaged through the channels of the working blade. Thus, the analysis of the gas-dynamic structure of the flow and its thermal state made it possible to clarify the physical model of the steam flow in the LPC at low-flow rate modes.