XTXiangyu Tan

Xiangyu Tan

*This is an algorithmically generated author record based on publicly available information.

Xiangyu Tan has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Insulator-Integrated Voltage-Current Sensor Based on Electric Field Coupling and Tunneling Magnetoresistance Technology

    by Xiangyu Tan, Yuan Liu, Ningbo Sun, Wenbin Zhang

    This paper proposes an integrated sensor for voltage and current distribution network insulators, based on electric field coupling and TMR magnetic sensing, to address the issues of traditional voltage and current separation measurement, insulator safety after primary and secondary fusion, uncertainty in voltage measurement gain, and interference resistance in TMR current measurements. Through simulation and optimization, the design of the embedded voltage-sensing unit in the insulator is achieved, ensuring uniform electric field distribution, determining the transfer function, and minimizing partial discharge, thereby ensuring insulator safety and improving voltage measurement accuracy. Additionally, a self-integrating circuit design is used to widen the low-frequency dynamic range and increase the voltage division ratio. Moreover, an open-type two-stage magnetic ring current sensor based on TMR is proposed, with optimized magnetic ring dimensions to detect currents from low to medium ranges, addressing eccentricity errors and improving sensitivity, immunity to interference, and magnetic field uniformity. The experimental results show that this integrated sensor can effectively ensure measurement accuracy, stability, and dynamic range.

  • Open Access

    Design of Open-Ended Structure Wideband PCB Rogowski Coil Based on New Winding Method

    by Qinghua Tan, Wenbin Zhang, Xiangyu Tan, Le Yang, Yanan Ren, Yang Hu

    Compared with the traditional Rogowski coil, printed circuit board (PCB) Rogowski coil has the advantages of high measurement accuracy, simple manufacturing process and low cost. It has become an important device in current measurement. However, the existing PCB Rogowski coils are mostly closed, and the open-ended structure PCB Rogowski coils are susceptible to external magnetic field interference. This paper proposes an open-ended structure PCB Rogowski coil based on a new winding method, so that the two open-ended PCB Rogowski coils are evenly distributed when closed, while improving the coil’s immunity to external magnetic fields based on the winding method of equal area of the de-wired and loop. In addition, this paper uses the hybrid integration circuit and the back-end matching method to achieve the broadband measurement performance of the sensor. Finally, the experimental results show that the mutual inductance difference between the closed and open-ended structure PCB Rogowski coil is less than 0.5% under the same wiring mode. Under the equivalent current interference at 50 mm from the measured current, the maximum interference coefficient of the open-ended structure coil is 1.45%; in sine sweep and pulse current test conditions, the frequency band is 34 Hz–3.5 MHz.


  • Open Access

    Research on UAV Three-Phase Transmission Line Tracking and Localization Method Based on Electric Field Sensor Array

    by Chunguang Suo, Jiawen Zhao, Wenbin Zhang, Peng Li, Rujin Huang, Junyu Zhu, Xiangyu Tan

    The tracking and positioning of transmission lines is a key element for UAVs (Unmanned Aerial Vehicles) to achieve autonomous inspection of transmission lines. Current methods are vulnerable to weather and environmental factors, have high costs, and have difficulties in data processing. Therefore, this paper proposes a transmission line tracking and localization method based on the electric field sensor array, which calculates the current UAV’s heading angle deflection angle, the distance between the transmission line and the UAV, and the elevation angle, providing a new idea to solve the problem of UAV inspection of transmission lines. At the same time, the electric field distribution of different arrangements of three-phase transmission lines was analyzed using COMSOL to determine the flight area of the UAV. By comparing the electric field distribution of the UAV flight area and single-phase transmission lines, it was verified that the current method is also applicable in the three-phase transmission line scenario, and it was further verified that the sensor array used can sense the change of the UAV position in the flight area, indicating that the electric field sensor array can realize the transmission line tracking and localization of transmission lines. The experimental results showed that, in the three-phase transmission line scenario, when the sensor array moves along the transmission straight wire, the maximum absolute error of the heading angle deflection angle calculated according to this method was 8.2°, the maximum absolute error of the distance between the array and the transmission line was 19.3 cm, and the maximum absolute error of the elevation angle was 11.37°; the error was within a reasonable range and can be used for the UAV to realize autonomous inspection.


  • Open Access

    Research and Experiments on an External Miniaturized VFTO Measurement System

    by Lizhe Wang, Wenbin Zhang, Xiangyu Tan, Weiren Chen, Shiqi Liang, Chunguang Suo

    Disconnect switch and circuit breakers operations in gas insulated switchgear (GIS) systems may produce very fast transient overvoltage (VFTO). Detecting VFTO is the first step for researchers to reduce the damage to other equipment of the substation caused by VFTO. Most of the existing sensors used for VFTO are generally bulky, complex to install, and require modification of the GIS structure. In this paper, a miniaturized measurement system that uses capacitive voltage divider and differentiating–integrating circuit is proposed. A special sensor structure and optimized differentiating–integrating circuit components arrangement were designed to increase the bandwidth of the measurement system. The frequency-domain, time-domain and voltage divide calibration experiment was performed, and a comparison experiment with an internal VFTO sensor was conducted. The measurement system was applied in the 500 kV GIS substation, and the VFTO measurement under specific conditions was carried out. The measured time domain and frequency domain waveforms conformed to the definition of standard VFTO according to IEC 60,071. It was found that the proposed measurement system meets VFTO measurement requirements and can be applied to actual VFTO measurements.