YTYu-Jung Tsai

Yu-Jung Tsai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yu-Jung Tsai has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • POUR-Net: A Population-Prior-Aided Over-Under-Representation Network for Low-Count PET Attenuation Map Generation

    by Bo Zhou, Jun Hou, Tianqi Chen, Yinchi Zhou, Xiongchao Chen, Huidong Xie, Qiong Liu, Xueqi Guo, Menghua Xia, Yu-Jung Tsai, et al.

    Low-dose PET offers a valuable means of minimizing radiation exposure in PET imaging. However, the prevalent practice of employing additional CT scans for generating attenuation maps ( μ -map) for PET attenuation correction significantly elevates radiation doses. To address this concern and further mitigate radiation exposure in low-dose PET exams, we propose an innovative P opulation-prior-aided O ver- U nder- R epresentation N etwork (POUR-Net) that aims for high-quality attenuation map generation from low-dose PET. First, POUR-Net incorporates an O ver- U nder- R epresentation N etwork (OUR-Net) to facilitate efficient feature extraction, encompassing both low-resolution abstracted and fine-detail features, for assisting deep generation on the full-resolution level. Second, complementing OUR-Net, a population prior generation machine (PPGM) utilizing a comprehensive CT-derived μ -map dataset, provides additional prior information to aid OUR-Net generation. The integration of OUR-Net and PPGM within a cascade framework enables iterative refinement of μ -map generation, resulting in the production of high-quality μ -maps. Experimental results underscore the effectiveness of POUR-Net, showing it as a promising solution for accurate CT-free low-count PET attenuation correction, which also surpasses the performance of previous baseline methods.


  • Joint motion estimation and penalized image reconstruction algorithm with anatomical priors for gated TOF-PET/CT

    by Yu-Jung Tsai, Chi Liu

    The presence of respiratory motion not only degrades the reconstructed image but also limits the utilization of anatomical priors in emission tomography. In this study, we explore the potential application of a joint motion estimation and penalized image reconstruction algorithm using anatomical priors in gated time-of-flight positron emission tomography/computed tomography (PET/CT). The algorithm is able to warp both the activity image and the attenuation map to align them with the measured data with the facilitation of anatomical information contained in the attenuation map. Five patient datasets, three acquired in single-bed position and two acquired in whole-body continuous-bed-motion mode, are included. For each patient, the attenuation map is derived from a breath-hold CT. The Parallel Levels Sets (PLS) is chosen as a representative anatomical prior. In addition to demonstrating the reliability of the estimated motion and the benefits of incorporating anatomical prior, preliminary results also indicate that the algorithm shows the potential to reconstruct an activity image in the space corresponding to that of the attenuation map, which could be applied to address the potential misalignment issue in applications involving multiple PET acquisitions but a single CT.


  • Open Access

    MDPET: A Unified Motion Correction and Denoising Adversarial Network for Low-Dose Gated PET

    by Bo Zhou, Yu-Jung Tsai, Xiongchao Chen, James S. Duncan, Chi Liu

    In positron emission tomography (PET), gating is commonly utilized to reduce respiratory motion blurring and to facilitate motion correction methods. In application where low-dose gated PET is useful, reducing injection dose causes increased noise levels in gated images that could corrupt motion estimation and subsequent corrections, leading to inferior image quality. To address these issues, we propose MDPET, a unified motion correction and denoising adversarial network for generating motion-compensated low-noise images from low-dose gated PET data. Specifically, we proposed a Temporal Siamese Pyramid Network (TSP-Net) with basic units made up of 1.) Siamese Pyramid Network (SP-Net), and 2.) a recurrent layer for motion estimation among the gates. The denoising network is unified with our motion estimation network to simultaneously correct the motion and predict a motion-compensated denoised PET reconstruction. The experimental results on human data demonstrated that our MDPET can generate accurate motion estimation directly from low-dose gated images and produce high-quality motion-compensated low-noise reconstructions. Comparative studies with previous methods also show that our MDPET is able to generate superior motion estimation and denoising performance. Our code is available at https://github.com/bbbbbbzhou/MDPET .


  • Performance Evaluation of Amplitude and Phase Respiratory Gating Methods on Continuous-Bed-Motion Whole-Body PET Studies

    by Yu-Jung Tsai, Yihuan Lu, Jing Wu, Hui Liu, Paul Schleyer, Michael Casey, Chi Liu

    Positron emission tomography (PET) scanners with the feature of continuous-bed-motion (CBM) that allows efficient whole-body dynamic scans and customized imaging protocols have been made commercially available in recent years. As the bed motion has to be reasonably slow in order to achieve sufficient count statistics, the blurring effect induced by respiratory motion is inevitable, and adequate gating methods should be applied. The aim of this study is to identify a relatively reliable gating method for CBM whole-body scans with respect to breathing pattern variability. Two methods: 1) equal amplitude gating (EAG) and 2) phase gating (PG) initially developed for the single-bed imaging protocol are evaluated using CBM data for subjects with a regular breathing pattern, irregular breathing pattern with baseline shift, and irregular breathing pattern with prolonged end expiration. The potential influence of the scan duration on the performance of the applied gating methods is taken into account as well. Based on the results, we suggest that the PG method is relatively reliable for all studied breathing patterns, while the EAG method could introduce severe artifacts in the presence of the baseline shift.


  • Open Access

    Penalized PET/CT Reconstruction Algorithms with Automatic Realignment for Anatomical Priors

    by Yu-Jung Tsai, Alexandre Bousse, Simon Arridge, Charles W. Stearns, Brian F. Hutton, Kris Thielemans

    Two algorithms for solving misalignment issues in penalized PET/CT reconstruction using anatomical priors are proposed. Both approaches are based on a recently published joint motion estimation and image reconstruction method. The first approach deforms the anatomical image to align it with the functional one while the second approach deforms both images to align them with the measured data. Our current implementation alternates between image reconstruction and alignment estimation. To evaluate the potential of these approaches, we have chosen Parallel Level Sets (PLS) as a representative anatomical penalty, incorporating a spatially-variant penalty strength to achieve uniform local contrast. The performance was evaluated using simulated non-TOF data generated with an XCAT phantom in the thorax region. We used the attenuation image in the anatomical prior. The results demonstrated that both methods can estimate the misalignment and deform the anatomical image accordingly. However, the performance of the first approach depends highly on the workflow of the alternating process. The second approach shows a faster convergence rate to the correct alignment and is less sensitive to the workflow. Interestingly, the presence of anatomical information can improve the convergence rate of misalignment estimation for the second approach but slow it down for the first approach.

  • Penalized PET/CT Reconstruction Algorithms With Automatic Realignment for Anatomical Priors

    by Yu-Jung Tsai, Alexandre Bousse, Simon Arridge, Charles W. Stearns, Brian F. Hutton, Kris Thielemans

    Two algorithms for solving misalignment issues in penalized PET/CT reconstruction using anatomical priors are proposed. Both approaches are based on a recently published joint motion estimation and image reconstruction method. The first approach deforms the anatomical image to align it with the functional one while the second approach deforms both images to align them with the measured data. Our current implementation alternates between alignment estimation and image reconstruction. We have chosen Parallel Level Sets (PLS) as a representative anatomical penalty, incorporating a spatially-variant penalty strength. The performance was evaluated using simulated non-TOF data generated with an XCAT phantom in the thorax region. We used the attenuation map in the anatomical prior. The results demonstrated that both methods can estimate the misalignment and deform the anatomical image accordingly. However, the performance of the first approach depends highly on the workflow of the alternating process. The second approach shows a faster convergence rate to the correct alignment and is less sensitive to the workflow. The presence of anatomical information improves the convergence rate of misalignment estimation for the second approach but slow it down for the first approach. Both approaches show improved performance in misalignment estimation as the data noise level decreases.


  • Benefits of Using a Spatially-Variant Penalty Strength With Anatomical Priors in PET Reconstruction

    by Yu-Jung Tsai, Georg Schramm, Sangtae Ahn, Alexandre Bousse, Simon Arridge, Johan Nuyts, Brian F. Hutton, Charles W. Stearns, Kris Thielemans

    In this study, we explore the use of a spatiallyvariant penalty strength in penalized image reconstruction using anatomical priors to reduce the dependence of lesion contrast on surrounding activity and lesion location. This work builds on a previous method to make the local perturbation response (LPR) approximately spatially invariant. While the dependence of lesion contrast on the local properties introduced by the anatomical penalty is intentional, the method aims to reduce the influence from surroundings lying along the lines of response (LORs) but not in the penalty neighborhood structure. The method is evaluated using simulated data, assuming that the anatomical information is absent or well-aligned with the corresponding activity images. Since the Parallel Level Sets (PLS) penalty is convex and has shown promising results in the literature, it is chosen as the representative anatomical penalty and incorporated into the previously proposed preconditioned algorithm (L-BFGSB-PC) for achieving both good image quality and fast convergence rate. A 2D disc phantom with a feature at the center and a 3D XCAT thorax phantom with lesions inserted in different slices are used to study how surrounding activity and lesion location affect the visual appearance and quantitative consistency. A bias and noise analysis is also performed with the 2D disc phantom. The consistency of the algorithm convergence rate with respect to different data noise and background levels is also investigated using the XCAT phantom. Finally, an example reconstruction for a patient dataset with inserted pseudo lesions is used as a demonstration in a clinical context. We show that applying the spatially-variant penalization with PLS can reduce the dependence of the lesion contrast on the surrounding activity and lesion location. It does not affect the bias and noise trade-off curves for matched local resolution. Moreover, when using the proposed penalization, significant improvement in algorithm convergence rate and convergence consistency is observed.


  • Open Access

    Fast Quasi-Newton Algorithms for Penalized Reconstruction in Emission Tomography and Further Improvements via Preconditioning

    by Yu-Jung Tsai, Alexandre Bousse, Matthias J. Ehrhardt, Charles W. Stearns, Sangtae Ahn, Brian F. Hutton, Simon Arridge, Kris Thielemans

    This paper reports on the feasibility of using a quasi-Newton optimization algorithm, limited-memory Broyden-Fletcher-Goldfarb-Shanno with boundary constraints (L-BFGS-B), for penalized image reconstruction problems in emission tomography (ET). For further acceleration, an additional preconditioning technique based on a diagonal approximation of the Hessian was introduced. The convergence rate of L-BFGS-B and the proposed preconditioned algorithm (L-BFGS-B-PC) was evaluated with simulated data with various factors, such as the noise level, penalty type, penalty strength and background level. Data of three 18 F-FDG patient acquisitions were also reconstructed. Results showed that the proposed L-BFGS-B-PC outperforms L-BFGS-B in convergence rate for all simulated conditions and the patient data. Based on these results, L-BFGS-B-PC shows promise for clinical application.


  • Open Access

    Spatially-variant Strength for Anatomical Priors in PET Reconstruction

    by Yu-Jung Tsai, Georg Schramm, Johan Nuyts, Sangtae Ahn, Charles W. Stearns, Alexandre Bousse, Simon Arridge, Kris Thielemans

    This study explores the use of a spatially-variant penalty strength, proposed initially for quadratic penalties, in penalized image reconstruction using anatomical information. We have used the recently proposed Parallel Level Sets (PLS) anatomical prior as it has shown promising results in the literature. It was incorporated into the previously proposed preconditioned algorithm (L-BFGS-B-PC) for achieving both good image quality and fast convergence rate. A 2-dimensional (2D) disc phantom with a hot spot at the center and a 3D XCAT thorax phantom with lesions inserted in different slices are used to study how surrounding activity and lesion location affect both the visual appearance and quantitative consistency, respectively. Anatomical information is provided and assumed to be well-aligned with the corresponding activity images. For the XCAT phantom, the inserted lesions are either present or absent in the anatomical images to investigate the influence of the anatomical penalty. The reconstructed images for both phantoms with and without applying the spatially-variant penalty strength are compared. Preliminary results demonstrate that applying the spatially-variant penalization with an anatomical prior can reduce the dependence of local contrast on background activity and lesion location. Further work to explore the potential benefit in clinical imaging is warranted.