Penalized PET/CT Reconstruction Algorithms With Automatic Realignment for Anatomical Priors
- 21 September 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (3) , 362-372
Abstract
Two algorithms for solving misalignment issues in penalized PET/CT reconstruction using anatomical priors are proposed. Both approaches are based on a recently published joint motion estimation and image reconstruction method. The first approach deforms the anatomical image to align it with the functional one while the second approach deforms both images to align them with the measured data. Our current implementation alternates between alignment estimation and image reconstruction. We have chosen Parallel Level Sets (PLS) as a representative anatomical penalty, incorporating a spatially-variant penalty strength. The performance was evaluated using simulated non-TOF data generated with an XCAT phantom in the thorax region. We used the attenuation map in the anatomical prior. The results demonstrated that both methods can estimate the misalignment and deform the anatomical image accordingly. However, the performance of the first approach depends highly on the workflow of the alternating process. The second approach shows a faster convergence rate to the correct alignment and is less sensitive to the workflow. The presence of anatomical information improves the convergence rate of misalignment estimation for the second approach but slow it down for the first approach. Both approaches show improved performance in misalignment estimation as the data noise level decreases.Keywords
All Related Versions
Funding Information
- GE Healthcare
- National Institute for Health Research, University College London Hospitals Biomedical Research Centre
This publication has 42 references indexed in Scilit:
- Respiratory motion models: A reviewMedical Image Analysis, 2013
- Respiratory motion blur identification and reduction in ungated thoracic PET imagingPhysics in Medicine & Biology, 2011
- A novel method for incorporating respiratory-matched attenuation correction in the motion correction of cardiac PET–CT studiesPhysics in Medicine & Biology, 2011
- A channelized Hotelling observer study of lesion detection in SPECT MAP reconstruction using anatomical priorsPhysics in Medicine & Biology, 2007
- A motion-incorporated reconstruction method for gated PET studiesPhysics in Medicine & Biology, 2006
- Four‐dimensional (4D) PET/CT imaging of the thoraxMedical Physics, 2004
- Numerical Observer Study of MAP-OSEM Regularization Methods With Anatomical Priors for Lesion Detection in$^67$Ga ImagesIEEE Transactions on Nuclear Science, 2004
- Spatiotemporal reconstruction of list-mode PET dataIEEE Transactions on Medical Imaging, 2002
- Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinogramsIEEE Transactions on Medical Imaging, 1999
- A row-action alternative to the EM algorithm for maximizing likelihood in emission tomographyIEEE Transactions on Medical Imaging, 1996