Charles W. Stearns
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Charles W. Stearns has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Alexandre Bousse
LaTIM, Inserm UMR 1101, Universit de Bretagne Occidentale, Brest, France
3 shared publications - Kris Thielemans
University College London
3 shared publications - Simon Robert Arridge
Department of Computer Science, University College London, London, United Kingdom
3 shared publications - Yu-Jung Tsai
Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA
3 shared publications - Georg Schramm
Department of Imaging and Pathology, KU Leuven, Leuven, Belgium
2 shared publications - Johan Nuyts
Nuclear Medicine and Molecular Imaging, KU Leuven, UZ Gasthuisberg, Herestraat 49, Leuven, 3000, BELGIUM
2 shared publications
Latest Publications
- 19 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (2)
Object independent scatter sensitivities for PET, applied to scatter estimation through fast Monte Carlo simulation
Objective: Scattered coincidences are a major source of quantitative bias in positron emission tomography (PET) and must be compensated during reconstruction using an estimate of scattered coincidences per line-of-response and time-of-flight bin. Such estimates are typically obtained from simulators with simple cylindrical scanner models that omit detector physics. Incorporating detector sensitivities for scatter is challenging, as scattered coincidences have less constrained properties (e.g., incidence angles) than true coincidences. Approach: We integrated a 5D single-photon detection probability lookup table (photon energy, incidence angle, detector location) into the simulator logic. The resulting scatter sinogram is multiplied by a precomputed, LUT-specific scatter sensitivity sinogram to yield the scatter estimate. Scatter was simulated with MCGPU-PET, a fast Monte Carlo simulator with a simplified scanner model, and applied to phantom data from a simulated GE Signa PET/MR in GATE. We evaluated three scenarios: 1. Long, high-count MCGPU-PET simulations from a known activity distribution (reference). 2. Same distribution with limited simulation time and counts. 3. Same low-count data with joint estimation of activity and scatter during reconstruction. Main result: In scenario 1, scatter-compensated reconstructions achieved <1% global bias in all active regions relative to true-only reconstructions. In scenario 2, noisy scatter estimates caused strong positive bias, but Gaussian smoothing restored accuracy to scenario 1 levels. In scenario 3, joint estimation under low-count conditions maintained <1% global bias in nearly all regions. Significance: Although demonstrated with a fast Monte Carlo simulator, the proposed scatter sensitivity modeling could enhance existing single scatter simulators used clinically, which typically neglect detector physics. This proof-of-concept also supports the feasibility of scatter estimation for real scans using fast Monte Carlo simulation, offering potentially greater accuracy and robustness to acquisition noise.
- 19 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (2)
Object independent scatter sensitivities for PET, applied to scatter estimation through fast Monte Carlo simulation
Objective: Scattered coincidences are a major source of quantitative bias in positron emission tomography (PET) and must be compensated during reconstruction using an estimate of scattered coincidences per line-of-response and time-of-flight bin. Such estimates are typically obtained from simulators with simple cylindrical scanner models that omit detector physics. Incorporating detector sensitivities for scatter is challenging, as scattered coincidences have less constrained properties (e.g., incidence angles) than true coincidences. Approach: We integrated a 5D single-photon detection probability lookup table (photon energy, incidence angle, detector location) into the simulator logic. The resulting scatter sinogram is multiplied by a precomputed, LUT-specific scatter sensitivity sinogram to yield the scatter estimate. Scatter was simulated with MCGPU-PET, a fast Monte Carlo simulator with a simplified scanner model, and applied to phantom data from a simulated GE Signa PET/MR in GATE. We evaluated three scenarios: 1. Long, high-count MCGPU-PET simulations from a known activity distribution (reference). 2. Same distribution with limited simulation time and counts. 3. Same low-count data with joint estimation of activity and scatter during reconstruction. Main result: In scenario 1, scatter-compensated reconstructions achieved <1% global bias in all active regions relative to true-only reconstructions. In scenario 2, noisy scatter estimates caused strong positive bias, but Gaussian smoothing restored accuracy to scenario 1 levels. In scenario 3, joint estimation under low-count conditions maintained <1% global bias in nearly all regions. Significance: Although demonstrated with a fast Monte Carlo simulator, the proposed scatter sensitivity modeling could enhance existing single scatter simulators used clinically, which typically neglect detector physics. This proof-of-concept also supports the feasibility of scatter estimation for real scans using fast Monte Carlo simulation, offering potentially greater accuracy and robustness to acquisition noise.
- 21 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (3) , 362-372
Penalized PET/CT Reconstruction Algorithms With Automatic Realignment for Anatomical Priors
Two algorithms for solving misalignment issues in penalized PET/CT reconstruction using anatomical priors are proposed. Both approaches are based on a recently published joint motion estimation and image reconstruction method. The first approach deforms the anatomical image to align it with the functional one while the second approach deforms both images to align them with the measured data. Our current implementation alternates between alignment estimation and image reconstruction. We have chosen Parallel Level Sets (PLS) as a representative anatomical penalty, incorporating a spatially-variant penalty strength. The performance was evaluated using simulated non-TOF data generated with an XCAT phantom in the thorax region. We used the attenuation map in the anatomical prior. The results demonstrated that both methods can estimate the misalignment and deform the anatomical image accordingly. However, the performance of the first approach depends highly on the workflow of the alternating process. The second approach shows a faster convergence rate to the correct alignment and is less sensitive to the workflow. The presence of anatomical information improves the convergence rate of misalignment estimation for the second approach but slow it down for the first approach. Both approaches show improved performance in misalignment estimation as the data noise level decreases.
- 21 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (3) , 362-372
Penalized PET/CT Reconstruction Algorithms With Automatic Realignment for Anatomical Priors
Two algorithms for solving misalignment issues in penalized PET/CT reconstruction using anatomical priors are proposed. Both approaches are based on a recently published joint motion estimation and image reconstruction method. The first approach deforms the anatomical image to align it with the functional one while the second approach deforms both images to align them with the measured data. Our current implementation alternates between alignment estimation and image reconstruction. We have chosen Parallel Level Sets (PLS) as a representative anatomical penalty, incorporating a spatially-variant penalty strength. The performance was evaluated using simulated non-TOF data generated with an XCAT phantom in the thorax region. We used the attenuation map in the anatomical prior. The results demonstrated that both methods can estimate the misalignment and deform the anatomical image accordingly. However, the performance of the first approach depends highly on the workflow of the alternating process. The second approach shows a faster convergence rate to the correct alignment and is less sensitive to the workflow. The presence of anatomical information improves the convergence rate of misalignment estimation for the second approach but slow it down for the first approach. Both approaches show improved performance in misalignment estimation as the data noise level decreases.
- Open Access
- 25 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 37 (4) , 1000-1010
Fast Quasi-Newton Algorithms for Penalized Reconstruction in Emission Tomography and Further Improvements via Preconditioning
This paper reports on the feasibility of using a quasi-Newton optimization algorithm, limited-memory Broyden-Fletcher-Goldfarb-Shanno with boundary constraints (L-BFGS-B), for penalized image reconstruction problems in emission tomography (ET). For further acceleration, an additional preconditioning technique based on a diagonal approximation of the Hessian was introduced. The convergence rate of L-BFGS-B and the proposed preconditioned algorithm (L-BFGS-B-PC) was evaluated with simulated data with various factors, such as the noise level, penalty type, penalty strength and background level. Data of three 18 F-FDG patient acquisitions were also reconstructed. Results showed that the proposed L-BFGS-B-PC outperforms L-BFGS-B in convergence rate for all simulated conditions and the patient data. Based on these results, L-BFGS-B-PC shows promise for clinical application.
- 25 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 37 (4) , 1000-1010
Open AccessFast Quasi-Newton Algorithms for Penalized Reconstruction in Emission Tomography and Further Improvements via Preconditioning
This paper reports on the feasibility of using a quasi-Newton optimization algorithm, limited-memory Broyden-Fletcher-Goldfarb-Shanno with boundary constraints (L-BFGS-B), for penalized image reconstruction problems in emission tomography (ET). For further acceleration, an additional preconditioning technique based on a diagonal approximation of the Hessian was introduced. The convergence rate of L-BFGS-B and the proposed preconditioned algorithm (L-BFGS-B-PC) was evaluated with simulated data with various factors, such as the noise level, penalty type, penalty strength and background level. Data of three 18 F-FDG patient acquisitions were also reconstructed. Results showed that the proposed L-BFGS-B-PC outperforms L-BFGS-B in convergence rate for all simulated conditions and the patient data. Based on these results, L-BFGS-B-PC shows promise for clinical application.
- Open Access
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Spatially-variant Strength for Anatomical Priors in PET Reconstruction
This study explores the use of a spatially-variant penalty strength, proposed initially for quadratic penalties, in penalized image reconstruction using anatomical information. We have used the recently proposed Parallel Level Sets (PLS) anatomical prior as it has shown promising results in the literature. It was incorporated into the previously proposed preconditioned algorithm (L-BFGS-B-PC) for achieving both good image quality and fast convergence rate. A 2-dimensional (2D) disc phantom with a hot spot at the center and a 3D XCAT thorax phantom with lesions inserted in different slices are used to study how surrounding activity and lesion location affect both the visual appearance and quantitative consistency, respectively. Anatomical information is provided and assumed to be well-aligned with the corresponding activity images. For the XCAT phantom, the inserted lesions are either present or absent in the anatomical images to investigate the influence of the anatomical penalty. The reconstructed images for both phantoms with and without applying the spatially-variant penalty strength are compared. Preliminary results demonstrate that applying the spatially-variant penalization with an anatomical prior can reduce the dependence of local contrast on background activity and lesion location. Further work to explore the potential benefit in clinical imaging is warranted.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Open AccessSpatially-variant Strength for Anatomical Priors in PET Reconstruction
This study explores the use of a spatially-variant penalty strength, proposed initially for quadratic penalties, in penalized image reconstruction using anatomical information. We have used the recently proposed Parallel Level Sets (PLS) anatomical prior as it has shown promising results in the literature. It was incorporated into the previously proposed preconditioned algorithm (L-BFGS-B-PC) for achieving both good image quality and fast convergence rate. A 2-dimensional (2D) disc phantom with a hot spot at the center and a 3D XCAT thorax phantom with lesions inserted in different slices are used to study how surrounding activity and lesion location affect both the visual appearance and quantitative consistency, respectively. Anatomical information is provided and assumed to be well-aligned with the corresponding activity images. For the XCAT phantom, the inserted lesions are either present or absent in the anatomical images to investigate the influence of the anatomical penalty. The reconstructed images for both phantoms with and without applying the spatially-variant penalty strength are compared. Preliminary results demonstrate that applying the spatially-variant penalization with an anatomical prior can reduce the dependence of local contrast on background activity and lesion location. Further work to explore the potential benefit in clinical imaging is warranted.
- 1 August 1995
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 42 (4) , 1075-1079
NECR analysis of 3D brain PET scanner designs
A dedicated 3D brain PET scanner has several advantages, most notably increased sensitivity, over a whole body scanner for neurological studies. However, brain scanners have higher scatter fractions, random count-rates and deadtime for the same activity concentration. We have used noise effective count-rate (NECR) analysis to compare brain scanners of 53, 60, and 66 cm diameter with the GE ADVANCE whole body scanner (93 cm diameter). Monte Carlo simulations of a brain-sized phantom (16 cm diameter, 13 cm length) in the ADVANCE geometry were used to develop a model for NECR performance, which was reconciled to results from a decay series measurement. The model was then used to predict the performance of the brain scanner designs. The brain scanners have noise effective sensitivities (the slope of the NECR curve at zero activity) as much as 40% higher than the body scanner. However, their NECR advantage diminishes quickly as the activity concentration increases. The brain scanners' NECR equals the body scanner with about 0.7-0.8 mCi in the phantom; the body scanner has superior NECR performance at higher activity levels. An imaging center concentrating on only very low activity imaging tasks would find the efficiency advantage of a smaller detector diameter valuable, while a center performing higher activity studies such as bolus water injections or 5 mCi FDG injections might prefer the count rate performance of a whole body scanner.<>
- 1 August 1995
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 42 (4) , 1075-1079
NECR analysis of 3D brain PET scanner designs
A dedicated 3D brain PET scanner has several advantages, most notably increased sensitivity, over a whole body scanner for neurological studies. However, brain scanners have higher scatter fractions, random count-rates and deadtime for the same activity concentration. We have used noise effective count-rate (NECR) analysis to compare brain scanners of 53, 60, and 66 cm diameter with the GE ADVANCE whole body scanner (93 cm diameter). Monte Carlo simulations of a brain-sized phantom (16 cm diameter, 13 cm length) in the ADVANCE geometry were used to develop a model for NECR performance, which was reconciled to results from a decay series measurement. The model was then used to predict the performance of the brain scanner designs. The brain scanners have noise effective sensitivities (the slope of the NECR curve at zero activity) as much as 40% higher than the body scanner. However, their NECR advantage diminishes quickly as the activity concentration increases. The brain scanners' NECR equals the body scanner with about 0.7-0.8 mCi in the phantom; the body scanner has superior NECR performance at higher activity levels. An imaging center concentrating on only very low activity imaging tasks would find the efficiency advantage of a smaller detector diameter valuable, while a center performing higher activity studies such as bolus water injections or 5 mCi FDG injections might prefer the count rate performance of a whole body scanner.<>