Andi Taufan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andi Taufan has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Nasruddin Nasruddin
Department of Mechanical Engineering, Faculty of Engineering, Universitas Indonesia, Depok, Indonesia
4 shared publications A. Manga
Magister Program in Mechanical Engineering Department, Universitas Indonesia, Depok, Indonesia
2 shared publications- Hom Bahadur Rijal
Graduate school of environmental and information studies, Tokyo City University, 3-3-1 Ushikubo-nishi, Tsuzuki-ku, Yokohama 224-8551, Japan
2 shared publications Ng Wai Tuck
Tunku Abdul Rahman University of Management and Technology
2 shared publicationsA Indriati
Research Center for Appropriate Technology, National Research and Innovation Agency, Subang, West Java, Indonesia
1 shared publicationA P Arsyad
Departement of Mechanical Engineering, Universitas Indonesia, Depok - Indonesia
1 shared publication
Latest Publications
- 16 April 2026
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 35 (9) , 1420-1442
Optimizing cooling and ventilation strategies for energy efficiency and thermal comfort in air-conditioned mosques under hot-humid climates
Air-conditioned mosques, which have large volumes and are used intermittently five times daily, face significant energy consumption challenges. This study investigated air-conditioning (AC) operation and ventilation strategies in a typical large-scale air-conditioned mosque in the hot-humid climate of Malaysia. Simulations were conducted to evaluate the impact of various AC operational scenarios and ventilation strategies on energy efficiency and thermal comfort. The findings emphasize that strategic modifications can yield significant energy savings without compromising worshipers’ comfort. A pre-cooling period of 10 min before prayers, except for dawn prayers, which require 20 min, demonstrates a 5% reduction in energy consumption. In an advanced scenario that integrates natural ventilation of lower (doors) and upper (clerestory windows) openings during dawn prayers, a 10-min pre-cooling period for other prayers, and an optimized adaptive setpoint temperature, energy savings of up to 15% can be achieved. Thermal comfort analysis shows that the mosque maintains thermal comfort during dawn prayer ventilation, with the upper opening, at an indoor temperature of 26–27°C and an air exchange rate of 3 h −1 . The results highlight the need to maintain indoor temperatures within optimal ranges to enhance occupant comfort while minimizing energy demand. This study has underscored the importance of integrating passive and active cooling strategies to improve energy efficiency in religious buildings with intermittent occupancy patterns.
- 16 April 2026
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 35 (9) , 1420-1442
Optimizing cooling and ventilation strategies for energy efficiency and thermal comfort in air-conditioned mosques under hot-humid climates
Air-conditioned mosques, which have large volumes and are used intermittently five times daily, face significant energy consumption challenges. This study investigated air-conditioning (AC) operation and ventilation strategies in a typical large-scale air-conditioned mosque in the hot-humid climate of Malaysia. Simulations were conducted to evaluate the impact of various AC operational scenarios and ventilation strategies on energy efficiency and thermal comfort. The findings emphasize that strategic modifications can yield significant energy savings without compromising worshipers’ comfort. A pre-cooling period of 10 min before prayers, except for dawn prayers, which require 20 min, demonstrates a 5% reduction in energy consumption. In an advanced scenario that integrates natural ventilation of lower (doors) and upper (clerestory windows) openings during dawn prayers, a 10-min pre-cooling period for other prayers, and an optimized adaptive setpoint temperature, energy savings of up to 15% can be achieved. Thermal comfort analysis shows that the mosque maintains thermal comfort during dawn prayer ventilation, with the upper opening, at an indoor temperature of 26–27°C and an air exchange rate of 3 h −1 . The results highlight the need to maintain indoor temperatures within optimal ranges to enhance occupant comfort while minimizing energy demand. This study has underscored the importance of integrating passive and active cooling strategies to improve energy efficiency in religious buildings with intermittent occupancy patterns.
- Open Access
- 16 October 2023
- Published by EDP Sciences in BIO Web of Conferences
- Vol. 69, 05001
Evaluation of Non-Wheat Noodle Machine Design with An Ergonomic Approach
Designing machines without involving the human factor can cause users discomfort, fatigue, and health problems. Ergonomic criteria when designing machines can increase user effectiveness. PT. Noang Prima Utama uses an extruder to produce pasta under the “LocaPasta” brand. Complaints of pain in the neck and back for 1-3 days due to standing position, bending down, and arms reaching forward for a long-time during production. The research objective was to evaluate the extruder design using the anthropometric method. Anthropometric data were tested for uniformity, data adequacy, and the determination of percentiles. Machine dimensions were compared with user anthropometer data for design improvement. When feeding materials into the hopper, the operator’s working posture needed to be more ergonomically adequate due to raised arms and pushing the material bit by bit (repetitively). The evaluation of the machine design based on anthropometric dimensions reveals several improvements. The redesigned extruder machine includes changes such as adjusting the footstep height to 27.7 cm so that the height of the setting box to 120.95 cm from the footstep (adjusting to standing shoulder height), allowing rotation of the setting box and the hopper height from the footstep is parallel to the standing elbow height which is 92.1 cm. With the implementation of the new prototype, the operator’s working posture no longer involves bending over while adjusting the machine, and the arms can comfortably rest on the hopper while feeding the material.
- 16 October 2023
- Published by EDP Sciences in BIO Web of Conferences
- Vol. 69, 05001
Open AccessEvaluation of Non-Wheat Noodle Machine Design with An Ergonomic Approach
Designing machines without involving the human factor can cause users discomfort, fatigue, and health problems. Ergonomic criteria when designing machines can increase user effectiveness. PT. Noang Prima Utama uses an extruder to produce pasta under the “LocaPasta” brand. Complaints of pain in the neck and back for 1-3 days due to standing position, bending down, and arms reaching forward for a long-time during production. The research objective was to evaluate the extruder design using the anthropometric method. Anthropometric data were tested for uniformity, data adequacy, and the determination of percentiles. Machine dimensions were compared with user anthropometer data for design improvement. When feeding materials into the hopper, the operator’s working posture needed to be more ergonomically adequate due to raised arms and pushing the material bit by bit (repetitively). The evaluation of the machine design based on anthropometric dimensions reveals several improvements. The redesigned extruder machine includes changes such as adjusting the footstep height to 27.7 cm so that the height of the setting box to 120.95 cm from the footstep (adjusting to standing shoulder height), allowing rotation of the setting box and the hopper height from the footstep is parallel to the standing elbow height which is 92.1 cm. With the implementation of the new prototype, the operator’s working posture no longer involves bending over while adjusting the machine, and the arms can comfortably rest on the hopper while feeding the material.
- 30 June 2023
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 183
Energy-efficient retrofitting strategies in mosque buildings: A review
- 30 June 2023
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 183
Energy-efficient retrofitting strategies in mosque buildings: A review
- 1 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 92-95
Performance Prediction of Adsorption Self-Cooling Mobile Container
Solar thermal cooling technology utilization such as adsorption cooling system has attracted researchers as an alternative to conventional vapor compression system. The adsorption cooling system can utilize low-grade heat as its power source. This paper presents a numerical simulation of a new conceptual design of adsorption self-cooling mobile container to predict its adsorption performance. The container was mathematically modeled to calculate and simulate cooling power, COP, SCP, and the lowest temperature that could be obtained. The design consists of four main components namely the adsorption chamber, valve system, refrigerant chamber, and cabin chamber. Comparison between silica gel-water and zeolite-water had been investigated. The results show that evaporator temperature profile of the system with zeolite-water is better than the other working pair. Minimum value of the evaporator temperature is 18.14°C with zeolite-water as the working pair. The average cooling power, COP, and SCP during adsorption process are 1.48 J, 0.014, 0.984 W/kg, respectively.
- 1 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 92-95
Performance Prediction of Adsorption Self-Cooling Mobile Container
Solar thermal cooling technology utilization such as adsorption cooling system has attracted researchers as an alternative to conventional vapor compression system. The adsorption cooling system can utilize low-grade heat as its power source. This paper presents a numerical simulation of a new conceptual design of adsorption self-cooling mobile container to predict its adsorption performance. The container was mathematically modeled to calculate and simulate cooling power, COP, SCP, and the lowest temperature that could be obtained. The design consists of four main components namely the adsorption chamber, valve system, refrigerant chamber, and cabin chamber. Comparison between silica gel-water and zeolite-water had been investigated. The results show that evaporator temperature profile of the system with zeolite-water is better than the other working pair. Minimum value of the evaporator temperature is 18.14°C with zeolite-water as the working pair. The average cooling power, COP, and SCP during adsorption process are 1.48 J, 0.014, 0.984 W/kg, respectively.
- 16 August 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2001 (1) , 020012
Experimental performance of adsorption chiller with fin and tube heat exchanger
Adsorption chiller is one of the solution related to environmental issues caused by conventional cooling system. This paper presents an experimental performance of adsorption chiller with fin and tube heat exchanger in Mechanical Engineering, Universitas Indonesia. The chiller design configuration is composed of two sorption chambers, each has compact fin tube heat exchangers as adsorber, condenser, and evaporator. The chiller is tested under typical condition for hot water inlet/cooling water inlet/chilled water outlet temperatures are 64.4/31/8.9°C, respectively. Heat and mass recovery was adopted in experiment to increase the cooling power. The cooling time was varied to obtain the heat recovery optimum time related to the performance. Average value of COP and cooling power were obtained 0.77 and 3.2 kW, respectively, at adsorption/mass recovery/heat recovery time 600/40/20.
- 16 August 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2001 (1) , 020012
Experimental performance of adsorption chiller with fin and tube heat exchanger
Adsorption chiller is one of the solution related to environmental issues caused by conventional cooling system. This paper presents an experimental performance of adsorption chiller with fin and tube heat exchanger in Mechanical Engineering, Universitas Indonesia. The chiller design configuration is composed of two sorption chambers, each has compact fin tube heat exchangers as adsorber, condenser, and evaporator. The chiller is tested under typical condition for hot water inlet/cooling water inlet/chilled water outlet temperatures are 64.4/31/8.9°C, respectively. Heat and mass recovery was adopted in experiment to increase the cooling power. The cooling time was varied to obtain the heat recovery optimum time related to the performance. Average value of COP and cooling power were obtained 0.77 and 3.2 kW, respectively, at adsorption/mass recovery/heat recovery time 600/40/20.
- Open Access
- 24 January 2018
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 105 (1) , 012003
Performance prediction of vaccine carrier using adsorption process and 13x/cacl2composite zeolite as adsorbent
Vaccine is one of the biggest problem that happen in Indonesia. Almost 75% vaccine is frozen on shipment process from Province to healthcare in district. Vaccine usually is transferred using a vaccine box whose the temperature has to be maintained at 2-8°C. The newest technology of vaccine box uses adsorption cooling and solar energy to keep the cold chain. This technology is separated into 3 modules which are cooling module (contain zeolite and water), vaccine box, and solar heater. The cooling module using adsorption as the cooling process, where the adsorption makes a pressure drop and causes the decrease of the temperature. The decrease temperature will be used as source of the cooling in the vaccine box. After the zeolite in cooling module reach the saturation because of adsorption process, it has to be heated up using solar cooker as the media. The solar cooker collects the energy from the sun using the principle of greenhouse effect. This study aimed to analyze if the design of vaccine box using adsorption cooling system and 13x/cacl2 composite zeolite as the adsorbent is suitable or not for holding the optimum temperature for vaccines. From simulation using MATLAB, an integrated technical computing including computation, visualization, and programming, the vaccine box could reach temperature 5°C and can be maintained for 12 hours with COP is 0.146. For the desorption process, it needs heat 150 KW and 23 minutes to complete the process.
- 24 January 2018
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 105 (1) , 012003
Open AccessPerformance prediction of vaccine carrier using adsorption process and 13x/cacl2composite zeolite as adsorbent
Vaccine is one of the biggest problem that happen in Indonesia. Almost 75% vaccine is frozen on shipment process from Province to healthcare in district. Vaccine usually is transferred using a vaccine box whose the temperature has to be maintained at 2-8°C. The newest technology of vaccine box uses adsorption cooling and solar energy to keep the cold chain. This technology is separated into 3 modules which are cooling module (contain zeolite and water), vaccine box, and solar heater. The cooling module using adsorption as the cooling process, where the adsorption makes a pressure drop and causes the decrease of the temperature. The decrease temperature will be used as source of the cooling in the vaccine box. After the zeolite in cooling module reach the saturation because of adsorption process, it has to be heated up using solar cooker as the media. The solar cooker collects the energy from the sun using the principle of greenhouse effect. This study aimed to analyze if the design of vaccine box using adsorption cooling system and 13x/cacl2 composite zeolite as the adsorbent is suitable or not for holding the optimum temperature for vaccines. From simulation using MATLAB, an integrated technical computing including computation, visualization, and programming, the vaccine box could reach temperature 5°C and can be maintained for 12 hours with COP is 0.146. For the desorption process, it needs heat 150 KW and 23 minutes to complete the process.
- 1 January 2017
- Published by AIP Publishing
Simulation of adsorber tube diameter’s effect on new design silica gel-water adsorption chiller
A new design of silica gel-water adsorption chiller is proposed. The design configuration is composed of two sorption chambers with compact fin tube heat exchangers as adsorber, condenser, and evaporator. Heat and mass recovery were adopted in order to increase the cooling capacity. Numerical modelling and calculation were used to show the performance of the chiller with different adsorber tube diameter. Under typical condition for hot water inlet/cooling water inlet/chilled water outlet temperatures are 90/30/7°C, respectively, the simulation results showed the best average value of COP, SCP, and cooling power are 0.19, 15.88 W/kg and 279.89 W using 3/8 inch tube.
- 1 January 2017
- Published by AIP Publishing
Simulation of adsorber tube diameter’s effect on new design silica gel-water adsorption chiller
A new design of silica gel-water adsorption chiller is proposed. The design configuration is composed of two sorption chambers with compact fin tube heat exchangers as adsorber, condenser, and evaporator. Heat and mass recovery were adopted in order to increase the cooling capacity. Numerical modelling and calculation were used to show the performance of the chiller with different adsorber tube diameter. Under typical condition for hot water inlet/cooling water inlet/chilled water outlet temperatures are 90/30/7°C, respectively, the simulation results showed the best average value of COP, SCP, and cooling power are 0.19, 15.88 W/kg and 279.89 W using 3/8 inch tube.
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1826, 020013
Design and performance prediction of solar adsorption cooling for mobile vaccine refrigerator
Adsorption cooling is a process that uses a drop-in pressure caused by the adsorption of adsorbate by adsorbent. Adsorption process creates a pressure drop which can bring down the temperature to the intended condition. This approach can be used in vaccine transportation as the vaccines need to be stored at low temperatures (2°C to 8°C for preserving vaccines). The pressure decrease can be obtained by adsorption water in zeolites and can also produce the temperature drop in the main chamber. The adsorption process of water will decrease until reaching saturation condition. Heat is needed to keep the system continuous as it starts a desorption process. From the simulation using MATLAB, it is found that the mobile vaccine refrigerator can reach the temperature of 2°C in 180 seconds with the amount of cooling power generated is up to 1530 W. The insulation can hold the allowable temperature range inside the vaccine cabin for 15.6795 hours.
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1826, 020013
Design and performance prediction of solar adsorption cooling for mobile vaccine refrigerator
Adsorption cooling is a process that uses a drop-in pressure caused by the adsorption of adsorbate by adsorbent. Adsorption process creates a pressure drop which can bring down the temperature to the intended condition. This approach can be used in vaccine transportation as the vaccines need to be stored at low temperatures (2°C to 8°C for preserving vaccines). The pressure decrease can be obtained by adsorption water in zeolites and can also produce the temperature drop in the main chamber. The adsorption process of water will decrease until reaching saturation condition. Heat is needed to keep the system continuous as it starts a desorption process. From the simulation using MATLAB, it is found that the mobile vaccine refrigerator can reach the temperature of 2°C in 180 seconds with the amount of cooling power generated is up to 1530 W. The insulation can hold the allowable temperature range inside the vaccine cabin for 15.6795 hours.