SWSamantha Walker

Samantha Walker

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Samantha Walker has a total of 206 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • CCAT: Mod-Cam Cryogenic Performance and Its Impact on 280-GHz KID Array Noise

    by Lawrence T. Lin, Eve M. Vavagiakis, Jason E. Austermann, James R. Burgoyne, Scott Chapman, Steve K. Choi, Abigail T. Crites, Cody J. Duell, Rodrigo G. Freundt, Eliza Gazda, et al.


  • CCAT: Design, Implementation, and Testing of a System to Read Out Over 10 000 280 GHz KIDs Using RFSoC Electronics

    by Darshan A. Patel, Yuhan Wang, Cody J. Duell, Jason E. Austermann, James Beall, James R. Burgoyne, Scott Chapman, Steve K. Choi, Rodrigo G. Freundt, Eliza Gazda, et al.


  • CCAT: Optical Responsivity, Noise, and Readout Optimization of KIDs for Prime-Cam

    by Eliza Gazda, Quintin Meyers, Steve K. Choi, James R. Burgoyne, Scott Chapman, Cody J. Duell, Anthony I. Huber, Inchara Jagadeesh, David Faulkner Katz, Ben Keller, et al.


  • CCAT: Flexible Stripline Circuits for Large-Format Kinetic Inductance Detector (KID) Array Readout

    by Ben Keller, Rodrigo Freundt, James R. Burgoyne, Scott Chapman, Steve Choi, Cody J. Duell, Christopher Groppi, Caleb Humphreys, Lawrence T. Lin, Alicia Middleton, et al.

    The CCAT Observatory’s primary science instrument, Prime-Cam, is nearing readiness for deployment to the Fred Young Submillimeter Telescope in the Atacama Desert in northern Chile. When fully deployed, Prime-Cam will field approximately 100 000 kinetic inductance detectors (KIDs) across seven instrument modules making both broadband and polarimetric measurements. Meanwhile, in-lab characterization of the first CCAT instrument module, a 280-GHz broadband camera fielding over 10 000 KIDs, is currently underway in the test bed instrument Mod-Cam. Both Mod-Cam and Prime-Cam will employ 46-cm-long low-thermal-conductivity flexible circuits (“stripline”) between 4 and 300 K to connect large-format arrays of multiplexed KIDs in each instrument module to readout electronics. The 280-GHz camera currently installed in Mod-Cam uses six of these striplines to read out its over 10 000 detectors. We have examined the thermal and electrical performance of the stripline installed in Mod-Cam in an effort to better optimize the readout chain for deployment in Prime-Cam. We begin by characterizing the oxygen-free high thermal conductivity (OFHC) copper in the stripline traces, allowing for the estimation of thermal loading through these flexible circuits in their configurations in both Mod-Cam and Prime-Cam. We then directly measure the thermal conductivity of the stripline, finding it is best described by $kA\,=\,22\pm \text{6}\,T^{0.84\pm 0.09}\,\mathrm{\mu W{\cdot } m{\cdot } K^{-1}}$ for temperature ranges of $6\,\mathrm{K} < T < 20\,\mathrm{K}$ and $kA\,=\,0.6\pm \text{0.3}\,T^{-0.4\pm 0.1}\,\mathrm{mW{\cdot } m{\cdot }K^{-1}}$ for ranges from $20\,\mathrm{K}< T < 80\,\mathrm{K}$. Following our thermal characterizations, we report on the transmission and crosstalk properties of the Mod-Cam readout chain, isolating elevated crosstalk to SMP-SMA transition printed circuit boards that interface with the stripline. This finding validates the stripline circuit as a viable high-density cabling option for large-format array readout.


  • Open Access

    CCAT: Magnetic Sensitivity Measurements of Kinetic Inductance Detectors

    by Benjamin J. Vaughan, Yuhan Wang, Cody J. Duell, Jason Austermann, James R. Burgoyne, Scott Chapman, Steve K. Choi, Abigail T. Crites, Eliza Gazda, Ben Keller, et al.

    The CCAT Observatory is a ground-based submillimeter to millimeter experiment located on Cerro Chajnantor in the Atacama Desert, at an altitude of 5,600 meters. CCAT features the 6-meter Fred Young Submillimeter Telescope (FYST), which will cover frequency bands from 210 GHz to 850 GHz using its first-generation science instrument, Prime-Cam. The detectors used in Prime-Cam are feedhorn-coupled, lumped-element superconducting microwave kinetic inductance detectors (KIDs). The telescope will perform wide-area surveys at speeds on the order of degrees per second. During telescope operation, the KIDs are exposed to changes in the magnetic field caused by the telescope's movement through Earth's magnetic field and internal sources within the telescope. We present and compare measurements of the magnetic sensitivity of three different CCAT KID designs at 100 mK. The measurements are conducted in a dilution refrigerator (DR) with a set of room temperature Helmholtz coils positioned around the DR. We discuss the implications of these results for CCAT field operations.


  • Direct Imaging of Transition-Edge Sensors With Scanning SQUID Microscopy

    by Samantha Walker, Austin Kaczmarek, Jason Austermann, Douglas Bennett, Shannon M. Duff, Johannes Hubmayr, Ben Keller, Kelsey Morgan, Colin C. Murphy, Daniel Swetz, et al.

    Significant advancements have been made in understanding the physics of transition-edge sensors (TESs) over the past decade. However, key questions remain, particularly a detailed understanding of the current-dependent resistance of these detectors when biased within their superconducting transition. We use scanning superconducting quantum interference device (SQUID) microscopy (SSM) to image the local diamagnetic response of aluminum-manganese alloy (Al-Mn) transition-edge sensors (TESs) near their critical temperature of approximately 175 mK. By doing so, we gain insights into how the device dimensions influence TES transition width, which in turn affects device operation and informs optimal device design. Our images reveal that the Al-Mn thin film near the niobium (Nb) leads exhibits an excess diamagnetic response at temperatures several milli-Kelvin (mK) higher than the bulk of the film farther from the contacts. A possible origin of this behavior is a longitudinal proximity effect between the Nb and Al-Mn where the TES acts as a weak link between superconducting leads. We discuss how this effect shapes the temperature dependence of the resistance as the spacing between the leads decreases. This work demonstrates that magnetic imaging with SSM is a powerful tool for local characterization of superconducting detectors.


  • CCAT: LED Mapping and Characterization of the 280 GHz TiN KID Array

    by Alicia Middleton, Steve K. Choi, Samantha Walker, Jason Austermann, James R. Burgoyne, Victoria Butler, Scott C. Chapman, Abigail T. Crites, Cody J. Duell, Rodrigo G. Freundt, et al.

    Prime-Cam, one of the primary instruments for the Fred Young Submillimeter Telescope (FYST) developed by the CCAT Collaboration, will house up to seven instrument modules, with the first operating at 280 GHz. Each module will include three arrays of superconducting microwave kinetic inductance detectors (KIDs). The first KID array fabricated for the 280 GHz module uses titanium-nitride (TiN) as the superconducting material and has 3,456 individual detectors, while the other two arrays use aluminum. This paper presents the design and laboratory characterization of the 280 GHz TiN array, which is cooled below its critical temperature to $\sim$ 0.1K and read out over six RF feedlines. LED mapping, a technique for matching the measured resonant frequency of a detector to its physical position, was performed on the array so that the results can be used to lithographically trim the KID capacitors and increase the yield of the array by reducing frequency collisions. We present the methods and results of LED mapping the 280 GHz TiN KID array before deployment on FYST.


  • A method for optimal tuning of microwave kinetic inductance detector arrays under dynamic loading conditions

    by Samantha Walker

    Microwave kinetic inductance detectors (MKIDs) are increasingly used in ground-based (sub)millimeter-wave astronomy experiments. Two existing challenges to operating detector arrays remain in selecting excitation tones for each MKID where there are hundreds of resonators on the same feedline or network and that will yield the best combination of linearity and sensitivity. This is further complicated when operating arrays at ground-based telescopes, where variations in background loading from the atmosphere can induce significant shifts in MKID resonant frequencies and affect quality factors. We describe a quantitative method for optimal tuning of MKID arrays under dynamic loading conditions. We apply this new readout tuning technique to the 1.1 mm MKID array of the TolTEC camera at the Large Millimeter Telescope, where we incrementally change the readout power applied to investigate its effect. We perform in lab optical characterization of a CCAT Observatory MKID array to investigate optimal tuning under different loading conditions.


  • Open Access

    The Simons Observatory: Galactic Science Goals and Forecasts

    by Brandon S. Hensley, Susan E. Clark, Valentina Fanfani, Nicoletta Krachmalnicoff, Giulio Fabbian, Davide Poletti, Giuseppe Puglisi, Gabriele Coppi, Jacob Nibauer, Roman Gerasimov, et al.

    Observing in six frequency bands from 27 to 280 GHz over a large sky area, the Simons Observatory (SO) is poised to address many questions in Galactic astrophysics in addition to its principal cosmological goals. In this work, we provide quantitative forecasts on astrophysical parameters of interest for a range of Galactic science cases. We find that SO can: constrain the frequency spectrum of polarized dust emission at a level of Δβ d ≲ 0.01 and thus test models of dust composition that predict that β d in polarization differs from that measured in total intensity; measure the correlation coefficient between polarized dust and synchrotron emission with a factor of two greater precision than current constraints; exclude the nonexistence of exo-Oort clouds at roughly 2.9σ if the true fraction is similar to the detection rate of giant planets; map more than 850 molecular clouds with at least 50 independent polarization measurements at 1 pc resolution; detect or place upper limits on the polarization fractions of CO(2–1) emission and anomalous microwave emission at the 0.1% level in select regions; and measure the correlation coefficient between optical starlight polarization and microwave polarized dust emission in 1° patches for all lines of sight with N H ≳ 2 × 1020 cm−2. The goals and forecasts outlined here provide a roadmap for other microwave polarization experiments to expand their scientific scope via Milky Way astrophysics. 37 37 A supplement describing author contributions to this paper can be found at https://simonsobservatory.org/wp-content/uploads/2022/02/SO_GS_Contributions.pdf.


  • Open Access

    Erratum: “The Simons Observatory Large Aperture Telescope Receiver” (2021, ApJS, 256, 23)

    by Ningfeng Zhu, Tanay Bhandarkar, Gabriele Coppi, Anna M. Kofman, John L. Orlowski-Scherer, Zhilei Xu, Shunsuke Adachi, Peter Ade, Simone Aiola, Jason Austermann, et al.